Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC 241 SWAMI NARAYAN NAGAR 1 OPP SWAMIVIVEKANA ASHRAM BEHIND HALAR HOUSE JAMNAGAR JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | ₹2.1 Cr | L1 | Accepted-AOC First Lowest quoted bidder |
| 2 | L2₹2.2 Cr+₹4.3 L (2.01%)Rejected-Finance 2 44 A 4 KALU SARAI HAUZ KHAS DELHI SOUTH WEST DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | ₹2.2 Cr+₹4.3 L (2.01%) | L2 | Rejected-Finance Not first lowest bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Fulfil the eligibitity criteria |
Tender Value
₹2.3 Cr
EMD Value
₹4.6 L
Closing Date
11 Sept 2023, 3:00 pmClosed
The Superintending Engineer
AB 9/303 IIT Gandhinagar
Operation and maintenance of Electrical and Mechanical installation of residential and non residential buildings of IITGN campus at Palaj, Gandhinagar.
2023_IITGN_767148_1
25/IITGN/IWD/2023-24
Open Tender
Electrical Works
Item Rate
365 days
IIT Gandhinagar
As per tender document
2 documents required · 2 mandatory
₹1,500
Payable To IIT Gandhinagar Revenue account
₹4.6 L
IIT Gandhinagar
9 Oct 2023
16 Aug 2023
12 Sept 2023
16 Aug 2023
11 Sept 2023
17 Aug 2023
17 Aug 2023 - 21 Aug 2023
21 Aug 2023
Amount
Providing manpower for day to day maintenance, upkeep, Breakdown maintenace, Preventive maintenance and attending complaints of complete internal and external electrical installations including all work assigned by Engineer-Incharge of all residential and non residential buildings within Institute campus, external lighting (All type of street, pathway and parcel area lights etc.) , panels, feeder pillar etc, on all days including Sundays and holidays etc as required in 3 shift daily, (24 X 7 and 365 Days where each shift shall be of 8 hour duration) as per Para no-1,2,17 and recovery as per para no 23, 24 under Scope of work & Schedule of maintenance. (Note : Material required for replacement of faulty fixture shall be measured and paid seprately.Cost of all tools, plants and consumables etc. required for above mentioned work is included in the scope of work.)
Providing manpower for day to day maintenance, upkeep, Breakdown maintenace, Preventive maintenance and attending complaints of complete internal and external electrical installation, solar water heater system including all work assigned by Engineer-Incharge of Guest house & Director residence on all days including Sundays and holidays etc as required in 2 shift daily, (24 X 7 and 365 Days where each shift shall be of 8 hour duration) as per Para no-1,2,17 and recovery as per para no 23, 24 under Scope of work & Schedule of maintenance. (Note : Material required for replacement of faulty fixture shall be measured and paid seprately.Cost of all tools, plants and consumables etc. required for above mentioned work is included in the scope of work.)
Comprehensive maintenance (Routine,Preventive and Breakdown maintenance) of stage lighting system comparising of electrical panel, motors and gear boxes for stage drapery, electrical panel with dimmers for stage lighting, light mixer, stage lights lamps, holder, Motorised curtain, motor,wire rope and complete assembly pulley, remote panel etc and associated wiring alongwith accessories installed in 1 no. 625 & 1 no. 325 capacity hall in block-1&2 of academic buildings as per Para no-3 and recovery as per para no 24 under Scope of work & Schedule of maintenance.
Annual comprehensive maintenance of online UPS with inverter static/manual bypass switch, connecting cables, complete as per Para no 18 of CPWD-6 of this tender document and as per Para no-4 and recovery as per para no 24 under Scope of work & Schedule of maintenance. Note 1: Battery repalcement excluded from the scope of work. Note 2: The work shall be carried out through manufacturer or his authorised agent on back to back basis only.
Single Phase input Single phase Output 2 KVA (Make : Numeric) -02 No. Location of Installation : Academic Substation-01 (Qty: 1 no.) and WTP substation (Qty: 1 no.).
Single Phase input Single phase Output 5 KVA (Make : Numeric,Uniline,IPC)-02 Nos. Location of Installation: Hostel Substation (Qty: 1 no.) and Main Infra Substation(Qty: 1 no.)
Three Phase Input Single phase Output 10 KVA (Make : Numeric) -04 Nos. Location of Installation: AB-7/109 (Qty: 2 nos.), AB-7/108 (Qty: 1 no.) and Academic Substation-02 (Qty: 1 no.)
Three Phase Input & three phase Output or Three Phase Input & Single Phase Output 15 KVA (Make : Numeric)-2Nos. Location of Installation: AB-7/108(Qty: 1 no.) and AB-4/216(Qty: 1 no.)
Three Phase Input Single phase Output 20 KVA (Make : Emerson) -01 No. Location of Installation: AB-9/Plantroom (Qty: 1 no.)
Supply, installation, testing and commissioning of following sealed Maintenance Free type Batteries suitable on buyback basis for online UPS system with Connecting cable for series connection of Batteries with Lugs, Nut bolts, washers, etc. Make : Amron (Quanta)/ Panasonic (Rebate on old battery to be taken in quotaed rate)
12 VDC,26 AH SMF battery suitable for UPS
12 VDC,42 AH SMF battery suitable for UPS
12 VDC,65 AH SMF battery suitable for UPS
Providing services for operation and day to day maintenance of all Electric Sub-station equipments including unitised/packaged Sub-Station, HT and LT panels, APFC panels, AMF Panels, 1 No. 500 KVA and 1 No. 140 KVA DG Set as per inventory attached on all days including Sundays and holidays etc as required in 3 shift daily, (24 X 7 and 365 Days where each shift shall be of 8 hour duration) as per Para no-5,17 and recovery as per para no 23,24 under Scope of work & Schedule of maintenance.
Comprehensive Maintenance of Sound Reiforcement system comprising Flying arrayble, ceilling or wall mounting speaker, Flying arrayble Sub woofer, dual/single Channel power Amplifier, Audio DSP, Mixer , Gooseneck,Dynamic Vocal/ condenser over head and instrumental/ wireless microphones of Assorted size (as per inventory) for one year including repair, replacement of parts, including upgradtion of software,supply of consumables as detailed in Annexure-IV as per Para no 15 of CPWD-6 of this tender document and as per Para no-11 and recovery as per para no 24 under Scope of work & Schedule of maintenance.
Providing services for operation and day to day maintenance of sound reinforcement system installed in class rooms, conference rooms , auditorium halls and Seminar rooms of all non- residential block & guest house comprising equipment as detailed in Annexure-IV along with stage lighing in two auditoriums,Consumable etc as per Para no-12,17 and recovery as per para no 23,24 under Scope of work & Schedule of maintenance.
Repair and Maintenance services for following height pole containing group of flood light fixtures etc at sports field as per inventory attached. Note: This item will be applicable only when work will be performed at height mentioned below.
Above 6 meter to 8 meter height pole including ladder charges etc as required.
More than 8 to 12 meter height pole including crane charges etc as required.
Supplying of following accessories and parts for replacement in existing installation as required.
6 Amp modular type one way switch (Make : MK Blenze Plus)
6A Round Pin Socket (ISI Marked) (Make : MK Blenze Plus)
6/16A Socket 2M modular type socket (Make : MK Blenze Plus)
16 Amp modular type one way switch (Make : MK Blenze Plus)
120 Watt 2 Modular type stepped fan regulator (Make : MK Blenze Plus)
6 Amp two way modular type switch (Make : MK Blenze Plus)
Bell Switch 6 AMP Bell Push Switch 1M (Make : MK Blenze Plus)
Modular base and cover plate 1 Module (Make : MK Blenze Plus)
Modular base and cover plate 2 Module (Make : MK Blenze Plus)
Modular base and cover plate 3module (Make : MK Blenze Plus)
Modular base and cover plate 4 module (Make : MK Blenze Plus)
Modular base and cover plate 6 module (Make : MK Blenze Plus)
Modular base and cover plate 8 module (Make : MK Blenze Plus)
Modular base and cover plate 9 module (Make : MK Blenze Plus)
Modular base and cover plate 12 module (Make : MK Blenze Plus)
Modular base and cover plate 18 module (Make : MK Blenze Plus)
Make my room (MMR) indicator (Make : MK Blenze Plus)
One way switch with MMR mark (Make : MK Blenze Plus)
Do not disturb (DND) indicator (Make : MK Blenze Plus)
One way switch with DND mark (Make : MK Blenze Plus)
Enegry key tag with time delay. (Make : MK Honeywell)
Ding Dong Bell (Anchor /Havell/ Philips)
RJ-45 socket I/O
RJ 45 single/double jack face plate
Painted MS, Fan Down Rod dia 15 mm Length 1.35 mtr
Ceiling Fan Capictor (2.5 mfd) (ISI Marked)-(Havells/Epcos/crompton)
Ceiling fan ball bearing (1 set =2 nos.)and nut bolt with spring washer (SKF/NBC)
70-100 Amp Terminal Block 4 ways
6-32 Amp, SPMCB ( "C" Curve, 240 Volts )
6-32 Amp, SPNMCB ( "C" Curve, 240 Volts )
6-32 Amp, TPMCB ( "C" Curve, 415 Volts )
40-63 Amp, TPMCB ( "C" Curve, 415 Volts )
6-32 Amps FP mcb( "C" Curve, 415 Volts )
40 -63Amps FP mcb( "C" Curve, 415 Volts )
100 Amp, FP MCB ("C" Curve, 415 Volts)
25 Amp, DP RCCB ( 240 Volts having sensitivity current up to 300 mA
40 Amp, DP RCCB ( 240 Volts having sensitivity current up to 300 mA
40 Amp, FP RCCB ( 415 Volts having sensitivity current up to 300 mA
63 Amp, FP RCCB ( 415 Volts having sensitivity current up to 300 mA
100 Amp, FP RCCB ( 415 Volts having sensitivity current up to 300 mA
40 Amps FP RCBO -300mA (ELMCB)( "C" Curve, 415 Volts )
63 Amps FP RCBO -300mA (ELMCB)( "C" Curve, 415 Volts )
16-25 Amps DP RCBO -300mA (ELMCB)( "C" Curve, 240 Volts )
16-100 Amps MCCB 25 KA, 3 Pole TMT Type with direct/vary/Extended depth rotary handle and trip contacts (Ics=100%Icu)
16-100 Amps MCCB 25 KA, 4 Pole TMT Type with direct/vary/Extended depth rotary handle and trip contacts (Ics=100%Icu)
250 Amps MCCB 36 KA, 4 Pole TMT Type with direct/vary/Extended depth rotary handle and ON,Off, trip contacts (Ics=100%Icu)
250 Amp MCCB 36 KA, 4 Pole Microprocessor Based with direct/vary/Extended depth rotary handle and ON,Off, trip contacts (Ics=100%Icu)
630 Amp MCCB 70 KA, 4 Pole Microprocessor Based+Earth fault release with direct/vary/Extended depth rotary handle and ON,Off, trip contacts (Ics=100%Icu)
4P,63Amp,4NO , 415 V, Modular contactor suitable for 230 Auxiliary supply (Similar to Legrand cat no. 412556)
DP sheet steel enclosure on surface/ recess (Make L&T/Legrand)
63-100 Amp MCCB 36KA, 4 Pole, TMT Type with direct/vary depth rotary handle and ON,Off, trip contacts (Ics=100%Icu) (Make:C & S )
Extended/vary depth type rotary handle for L&T, Legrand, C&S Make MCCB of range (63-250) Amp
DIN Mounting, multifunction meter, single phase 5-40 Amp suitable to install in Distribution board. (Similar to L&T cat no WD4000101OOO)
Electronic Buzzer (Make : MK Honeywell)
Supplying of following accessories/parts for replacement in existing installation as required.
PVC Exhaust Fan (150 mm sweep/ 200 mm sweep)
PVC Exhaust Fan (250 mm sweep)
T-5 lamps 28 W lamp
10 Watt 2 pin LED lamp with Inbuilt driver for Replacement of 18 watt 4 OR 2 pin PLC
70 Watt Metal Halide Lamp
70 Watt Metal Halide fixture Ballast
70 Watt Metal Halide fixture ignitor
70 Watt Metal Halide fixture capacitor
70 Watt CDMT Lamp
70 Watt CDMT fixture Ballast/circuit
400 Watt Metal Halide Lamp
400 Watt Metal Halide fixture Ballast
400 Watt Metal Halide fixture ignitor
400 Watt Metal Halide fixture capacitor
400 Watt Metal Halide Ceramic Outer Material holder
36-38 watt 2 x 2 feet LED fixture Driver
43 watt suspended LED fixture Driver
18-24 watt surface mounted LED fixture Driver/ PCB
18-24 watt downlighter recess mounted LED fixture Driver
LED Driver for 54 watt LED Street light & Post of lantern fixture.
LED Driver for 50 watt LED Street light & Post of lantern fixture.
LED Driver for 24 watt LED Street light fixture.
LED Driver/PCB for 27 watt Philips MakePost of lantern fixture (Fixture Model no LED2300/ww psu 220-240V 7043 IN)
5W wall/ceiling mounting type LED Batten 1 feet Luminaire, IP 20 ,colour temperature 2700 K having efficacy not less than 80 lm/W, CRI ≥ 80 ,THD ≤ 20%, Extruded Aluminum / Engineering plastic housing, inbuilt electronic driver 2700K (Make Wipro- D530565)
9W-10W wall / ceiling mounting type LED Batten 2 feet Luminaire, IP 20 ,colour temperature 4000/5700/6500 K having efficacy not less than 80 lm/W, CRI ≥ 80 ,THD ≤ 20%, Extruded Aluminum / Engineering plastic housing, inbuilt electronic driver (make - WIPRO - LL20-111-XXX-65NE3 - 10W / PHILIPS - BN021 LED 10S-6500 PSU GRS1 - 10W)
Surface mounted fixture with 20 Watt wall/ceiling mounting colour temperature 6500k, Polycarbonate housing body, high transitivity optically efficient diffuser for defuse lighting, in- built driver, surface mounting Clamp, LED batten of 4 feet length having lumen >2000 etc. and burning life > 25000 Hrs. suitable for continuous duty. (Similar to wipro Model No. LL20-111-XXX-65NE)
LED Lamp 18W Cool White Cleanray LED, (Similer to Wipro Pro MODEL NO LL13-181-650-G1)
Bollard made of extruded aluminium housing to redefine landscapes, IP 65,( Make: Wipro LB14-880-XXX-65-05)
Non integral inground burial light fixture 6 Watt, 3000K, outdoor type. (Make: Wipro LI20-600-030-30-XX)
Non integral inground burial light fixture 12 Watt, 3000K, outdoor type. (Make: Wipro LI20-111-030-30-XX)
Recess mounting fixture of 15 watt, having 1500 Luman, 4000-6500 K, IP 40, (Similer to wipro Make LD06X-171-XX-57-XX)
LED driver suitable for inground burial light fixture (6-12) Watt, outdoor type, (Similer to wipro driver LPV-35-24)
Surface mounted fixture with 38 Watt ceiling mounting colour temperature 6500k, IP-65 type Polycarbonate housing body, high transitivity optically efficient diffuser for defuse lighting, in- built driver, surface mounting Clamp and burning life > 25000 Hrs. suitable for continuous duty. (Similar to Philips Model No. WT550C)
36W-40W surface mounting type LED luminaire, IP 20 ,colour temperature 6500K having efficacy not less than 100 lm/W, THD ≤ 20%, CRCA/aluminium housing, suitable diffuser, inbuilt electronic driver, (Accomodation Rooms) (Make-Philips - BN100C LED 40S PSU CDL WH)
12 watt surface mounting type Spike light LED luminaire, IP 65 ,colour temperature 4000K having efficacy not less than 100 lm/W, THD ≤ 20%, CRCA/aluminium housing, suitable diffuser, inbuilt electronic driver (Make-Philips model no. 31386)
5-7 watt surface mounting type Spike LED luminaire, IP 65 ,colour temperature 4000K having efficacy not less than 100 lm/W, THD ≤ 20%, CRCA/aluminium housing, suitable diffuser, inbuilt electronic driver (Make-Philips model no. 31385)
Digital time switch single output configuration Din rail Mounted for automatic switching On & OFF (Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status.
Resincast / fibreglass insulated Current transformers of highest system voltage 415V rectangular/ ring type with class 1.0 accuracy & 5/10 VA Burden suitable for metering purpose of following ratio confirming to IS 2705:Part-I & II/IEC:185 with latest amendments etc 800 /5 Amp
Resincast / fibreglass insulated Current transformers of highest system voltage 415V rectangular/ ring type with class 1.0 accuracy & 5/10 VA Burden suitable for metering purpose of following ratio confirming to IS 2705:Part-I & II/IEC:185 with latest amendments etc 400 /5 Amp
Resincast / fibreglass insulated Current transformers of highest system voltage 415V rectangular/ ring type with class 1.0 accuracy & 5.0 VA Burden suitable for metering purpose of following ratio confirming to IS 2705:Part-I & II/IEC:185 with latest amendments etc 200 /5 Amp
Three pole , 415 V, contactor suitable for 230V Auxiliary Supply in the existing MCB DB 40A (Similar to L&T MNX 40)
240V AC Panel Mounted LED Indicator (16 mm dia to 22.5 mm dia) in Red/yellow/blue/green/amber (Make L&T/Legrand)
Panel mounting push button for starter operation (Green/Red colour).( Make L&T/Legrand)
Electronic Timers for star delta starter panel (L&T/Scheinder/ABB/Siemens)
Changover switch of LT panel for local-remote and auto-manual operation. (Make : Salzer)
3 Pin 6 Amp Plug Top (Make: Anchor/L&T/Havells)
3 Pin 16 Amp Plug Top (Make: Anchor/L&T/Havells)
9 Watt LED Bulb (B22 Base Cap, 4000K/5700K/6500K)
MV/HV Panel door lock knob type (material : alloy Steel)
Outdoor type electrical danger plate/warning signage/caution board made of aluminium body of minimum size (250 X 250)mm including all text in Hindi/English/Gujarati language as directed by Engineer In-charge
Exit LED signages hanging type suitable for 240 volt AC supply, colour Green/Red . (Equivalent to Make Bajaj, Cat no. BESL O3 LED SSD WBB)
LED flood light of 100 watt, IP 66, 6500K, (Equivalent to Make Havells, Model no JFL100W-G, Cat no LHEECNP7PB7J100 )
11KV voltage indicator suitable to install in C&S/Seimens Make compact substation of capacity (315-1000) KVA, (Similar to Make Supernova Electric part no 33108201-01)
9 Volt Duracell battery
1.5 Volt Duracell battery, AA
Supply,Installation,Testing and Commissioning of Surface mounted fixture with 10W-12W wall / ceiling mounting type LED panel type down light or decorative Luminaire with LED bulb, IP 20 ,colour temperature 4000/5700 K or panel light having efficacy not less than 80 lm/W, CRI ≥ 80 ,THD ≤ 20%, Extruded Aluminum / CRCA / Metal housing / Thermoconductive plastic housing, inbuilt electronic driver including dismantling of existing fixture etc. as required. (Similar to wipro Model No. J029-12W)
Supply,Installation,Testing and Commissioning of three Phase multifunction meter digital type accuracy Class -1.0 (96mm X 96mm) with RS-485 communication port suitable for measuring current, voltage, frequency, Power factor, watts, KWH after dismantling of Existing meter including control wiring,lugs ferruls etc. (Similar to L&T WL440011OOOO)
Detection of cable fault of 11 KV H T cable, XLPE insulated and PVC sheathed including Hipot test, fault locating kit etc complete as required.
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. a) 240 sq. mm
Supply and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulate and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
3½ X 185 sq. mm (57mm)
3½ X 240 sq. mm (62mm)
Rewinding of ceilling fans with Super enamled copper wire of Assorted makes and following sizes i/c varnishing ,overhauling, replacement of Ball bearing etc as required.
900 mm sweep
1200mm sweep
1400 mm sweep
Rewinding of metal Exhaust fans of following sizes i/c varnishing ,overhauling, replacement of ball bearing etc as required.
200/250 mm Sweep
300 mm sweep
Supply, installation, testing and commissioning of minimum 800 CFM propeller type fan of 250 mm dia with Aluminium / SS blades complete with induction motor suitable for operation on 230 V single phase 50 Hz single phase AC supply and suitable frame as per IS:2312-1967 with gravity dampers, bird screen, mounting arrangement complete as per specifications. The maximum sound level of unit shall be 45 dB(A) @ 3m from source. (Make : Kruger / Nicotra / Caryaire)
Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. (Make: Legrand)
1 output per phase and suitable for single phase supply
2 output per phase and suitable for single phase supply
Substation Equipment Preventive maintenance, Overhauling, Servicing and testing of 3P/4P Electrically Operated Draw Out type LT Air Circuit Breaker upto 1600 Amps rating (LT breaker Make: L&T, ABB, siemens) including Service Kit as per manufacturer standards (Excluding Spare but including consumables) as per Para no 16 of CPWD-6 of this tender document and as per Para no-9 under Scope of work & Schedule of maintenance. Note: The work shall be carried out through manufacturer or his authorised agent on back to back basis only.
Annual noncomprehensive maintenance of 500 kVA Genset Sudhir make, quaterly preventive maintenance service visits, including Breakdown maintenance of DG set complete as per recommendation of Manfacturer and as per Para no 17 of CPWD-6 of this tender document and as per Para no-10 and recovery as per para no 24 under Scope of work & Schedule of maintenance. Note: The work shall be carried out through manufacturer or his authorised agent on back to back basis only.
Annual noncomprehensive maintenance of 140 kVA Genset Sudhir make, quaterly preventive maintenance service visits, including Breakdown maintenance of DG set complete as per recommendation of Manfacturer and as per Para no 17 of CPWD-6 of this tender document and as per Para no-10 and recovery as per para no 24 under Scope of work & Schedule of maintenance. Note: The work shall be carried out through manufacturer or his authorised agent on back to back basis only.
Annual noncomprehensive maintenance for 10 kVA Bio gas Genset Green Power Solution make , quaterly preventive maintenance service visits, including Breakdown maintenance of DG set complete as per recommendation of Manfacturer and as per Para no 17 of CPWD-6 of this tender document and as per Para no-10 and recovery as per para no 24 under Scope of work & Schedule of maintenance. Note: The work shall be carried out through manufacturer or his authorised agent on back to back basis only.
Supply of consumable required for B check such as Element Lub Oil filter, Element oil bypass filter, Seperator fuel water, Element CRN Resistor, Valvoline Premium blue 7800 plus 1/55 Ltr., Element air cleaner, Inhibitor corrosion 10 Ltr., Radiwash 3 Ltr., etc. all material required for B check as per manufacturor recomendation of following DG Set. Note: The work shall be carried out through manufacturer or his authorised agent (Make: Sudhir DG) on back to back basis only.
500 KVA DG Set
Supply of consumable required for B check such as Cartridge lub oil filter, filter fuel, Valvoline Premium blue 7800 plus 1/20 Ltr., Belt V Ribbed, etc. all material required for B check as per manufacturor recomendation of following DG Set. Note: The work shall be carried out through manufacturer or his authorised agent (Make: Sudhir DG) on back to back basis only.
140 KVA DG set
Supply of single core 11 KV grade aluminium earthed conductor cable, standard compacted circular conductor, conductor screen with extruded semi conducting compound, XLPE ( E ) insulated, insulation screening with extruded semi conducting compound in combination with copper tape, AL round wire/flat strip armoured, and overall PVC sheathed cable conforming to IS 7098 (Part-2) with up to date amendments, having 5 meter length suitable for 315 KVA to 1000 KVA unitised substation of following size including end termination on both sides, with proper armoured earthing arrangements complete as required and directed by engineer in charge. Cable Make : KEI, Polycab, Finolex, Hevells, Avocab Cable Jointing Kits Make :- Reychem, 3M.
Single core 95 Sq. mm.
Single core 240 Sq. mm.
Filling the SF6gas for the 11kV RMU units inside the compact substation units (CSS) to the required pressure as per the manufacturer recommendation and engineer in charge direction complete as required
(315 kVA to 1000 kVA)
Preventive maintenance, Overhauling, Servicing and testing of 11KV Vacuum Circuit Breaker of C&S and Siemens Make upto 1250 Amps rating as per manufacturer standards (Excluding spares but including consumable) as per Para no 16 of CPWD-6 of this tender document and as per Para no-6 under Scope of work & Schedule of maintenance. Note: The work shall be carried out through manufacturer or his authorised agent on back to back basis only.
Preventive maintenance, Overhauling, Servicing and testing of main 11 kV C&S Make HT panel Consists of two Incomers, Six Outgoings and a Buscoulper, Tightness checking of bus bars, Cable terminations, control wiring, Insulation Resistance Testing of bus bar, interlocking including CT calibeation -24 Nos , caliberation & setting of all type protective relay-16 Nos, primary and secondary injections etc as per manufacturer standards (Excluding spares but including consumable) as per Para no 16 of CPWD-6 of this tender document and as per Para no-7 under Scope of work & Schedule of maintenance. Note: The work shall be carried out through manufacturer or his authorised agent on back to back basis only. Location of installation: Main Infra substation. VCB Maintenance not in the scope of this item.
Preventive maintenance, Overhauling, Servicing and testing of main 11 kV C&S Make HT panel Consists of two Incomers, Four Outgoings, Tightness checking of bus bars, Cable terminations, control wiring, Insulation Resistance Testing of bus bar, interlocking including CT calibeation -18 Nos , caliberation & setting of all type protective relay-18 Nos, primary and secondary injections etc as per manufacturer standards (Excluding spares but including consumable) as per Para no 16 of CPWD-6 of this tender document and as per Para no-7 under Scope of work & Schedule of maintenance. Note: The work shall be carried out through manufacturer or his authorised agent on back to back basis only. Location of installation: Sport complex VCB Maintenance not in the scope of this item.
Preventive maintenance of main 11 kV Siemens Make HT panel Consists of two Incomers, Three Outgoings, Tightness checking of bus bars, Cable terminations, control wiring, Insulation Resistance Testing of bus bar, interlocking including CT calibeation -15 Nos , caliberation and setting of all type protective relay-13 Nos, primary and secondary injections etc as per manufacturer standards (Excluding spares but including consumable) as per Para no 16 of CPWD-6 of this tender document and as per Para no-7 under Scope of work & Schedule of maintenance. Note: The work shall be carried out through manufacturer or his authorised agent on back to back basis only. Location of installation: Research Park VCB Maintenance not in the scope of this item.
Maintenance, Overhauling, Servicing and testing of C&S, Siemens Make Compact substations consisiting 11 kV RMU Unit (Two Isolators and One 11kV SF6 breaker) alongwith Dry type Transformer of rating 315 KVA to 1000 kVA including CT caliberation - 3 Nos/ Each unit , caliberation and setting of all protective relay, primary and secondary injections etc as per manufacturer standards (Excluding spares but including consumable) as per Para no 16 of CPWD-6 of this tender document and as per Para no-8 under Scope of work & Schedule of maintenance. Note: The work shall be carried out through manufacturer or his authorised agent on back to back basis only.
Preventive maintenance, Overhauling, Servicing and testing of (800-1000) KVA Transformer of Kirloskar, Voltamp Make complete with transformer testing IR/PI Test, Ratio Test,Vector Group Test, Magnetic Balance Test, OLTC /TAP, Operation Check, Magnetizing current, Winding Resistance inculding Deputation of testing team along with Required Testing Kit etc as per manufacturer standard (Excluding spares but including consumable) as per Para no-8(B) under Scope of work & Schedule of maintenance. Note: The work shall be carried out through specialized firm only.
Making under ground boring below roads, below pathway, upto 63mm dia and refilling if requred and diposal of waste, balace soil, stones etc complete as required.
Making of 65 mm dia size holes with core cutting machine in RCC/brick wall as required.
Dismantling and removing of street light pole with light fixture from exsisting RCC foundation and shifting to proper location as per instruction given by engineer incharge etc. as required.
Upto 4.0 Mtr
Above 4.0 mtr upto 6.0 mtr
Supply of additional Manpower (skilled) for 08 hrs at IITGN for maintenace work, minor work and Petty work including T&P etc as required after prior approval from Engineer-Incharge.
Comprehensive maintenance which includes routine, preventive and break down maintenance of the complete Siemens make Fire alarm system comprises of Main Panels, Addressable Smoke and heat detectors, cabling, battery for panel, all other associated electrical accessories etc. provided and installed Academic block-9 GF & FF including repair and replacement of parts, supply of consumables etc. as required. This shall also include a minimum of Quaterly preventive maintenance visits by manufacturer or his authorized personnel as per Para no 18 of CPWD-6 of this tender document and as per Para no-13 and recovery as per para no 24 under Scope of work & Schedule of maintenance. Note: The work shall be carried out through manufacturer or his authorised agent on back to back basis only.
Removing of colour wash from panel and feeder piller by scrapping and sand papering and preparing the surface smooth including all necessary repairs to scratches etc. Complete as required.
Spary Painting on panel and feeder piller with PU paint of approved brand and manufacture of required colour to give an even shade to panel Complete as required.
Minimum Two coats or upto satisfaction of Engineer In -charge
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work.
Painting of Streetlight pole following size after scrubbing the rust from pole with 2 coat of PU paint i/c sign writing pole number.Supply of all materials,labour and matching with exhisting color pole etc. as directed by the engineer in charge complete in all respect.
Size 5.6 mtr long
Size 2.7 mtr long
Size 3 mtr long
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
90 mm dia (OD-90 mm & ID-76 mm nominal)
Annual Comprehensive maintenance which includes routine, preventive and break down maintenance of the complete Split air conditioning system comprising of all indoor and outdoor units, evaporator and copper condensor coil, capacitor, refrigerant and drain piping, thermal insulation, PCB, sensors and all other associated electrical & mechanical accessories etc. provided and installed Guest House, Academic blocks, Housing blocks, Hostels including repair and replacement of parts, supply of consumables (Oil, grease, all refrigerant required for topping up, filter elements etc.) (except compressor) etc. as required. This shall also include a minimum of 4 Quaterly preventive maintenance visits per year by qualified personnels who are thoroughly familiar with the type of equipment and system provided as per Para no-14 and recovery as per para no 24 under Scope of work & Schedule of maintenance.
1.0 TR Split AC of make Samsung, Voltas,
1.5 TR Split AC of make Samsung, LG, Voltas, Hitachi, Daikin Toshiba
2.0 TR Split AC of make Samsung, LG, Voltas, Hitachi, Daikin, Panasonic, Toshiba
Supply,installation,testing & commissioning of compressor of approved make including dismantling of old one and fixing of new one for following Capacity split AC etc as required ( Make copeland emerson and equivalent)
1 TR to 1.5 TR
Annual Comprehensive maintenance which includes routine, preventive and break down maintenance of the complete Water cooler system compressor units, refrigerant, cooling tank, thermostate, sensors, internal wiring and piping, tap, water tray, drain and overflow piping, power cable, plug top and all other associated electrical & mechanical accessories etc. provided and installed Academic block,Hostels and other locations including repair and replacement of parts, supply of consumables (Oil, grease, all refrigerant required for topping up, filter, elements,taps etc.) (except compressor) etc. as required. This shall also include a minimum of 4 Quaterly preventive maintenance visits per year by qualified personnels who are thoroughly familiar with the type of equipment and system provided as per Para no-15 and recovery as per para no 24 under Scope of work & Schedule of maintenance.
(40 to150) LPH/ (80 to 150) Litre Full Stainless Steel . Make: Voltas, Bluestar
Supply,installation,testing & commissioning of compressor of approved make including dismantling of old one and fixing of new one with Refrigerent gas charging for following Capacity water cooler etc as required ( Similar to Exisitng)
Voltas 150 LPH/ 150 Litre Full Stainless Steel
Voltas 60 LPH/ 120 Litre Full Stainless Steel
Voltas/Bluestar 40 LPH/ 80 Litre Full Stainless Steel
Annual Comprehensive maintenance which includes routine, preventive and break down maintenance of the complete Oasis make Drinking Water Fountain units and booster pump set including compressor units, refrigerant and drain piping, all other associated electrical and mechanical accessories etc. provided and installed Academic block,Hostels and other locations including repair and replacement of parts, supply of consumables (Oil, grease, all refrigerant required for topping up, filter, elements,taps etc.) etc. as required. This shall also include a minimum of 4 Quaterly preventive maintenance visits per year by the manufacturer or his authorised personnel as per Para no 18 of CPWD-6 of this tender document and as per Para no-16 and recovery as per para no 24 under Scope of work & Schedule of maintenance. Note: The work shall be carried out through manufacturer or his authorised agent on back to back basis only.
Dismentling of split type AC Unit (1.0 Tr. or 2Tr.) (Indoor & Outdoor) including piping,cabling etc and shifting in store etc. as required
Installation of split type AC Unit (1.0 Tr. or 2Tr.) (Indoor/Outdoor), including 3 mtr. Fixing & Laying of Refrigerent copper pipe with Nitrile rubber insulation along with 3C X2.5 sq. mm PVC insulated, PVC sheathed, copper conductor cable i/c all fitting accessories, servicing of existing unit ,testing and commissioning and Transportation from store to site etc. as required.
Supply,installation,testing and commissioning of 5/8" & 3/8" refrigerant copper piping insulated with 6 mm thick nitrile rubber insulation, joints sealed with black tape and 4c x 2.5sq mm copper conductor pvc insulated pvc sheathed round cable fixing on the exisiting wall surface / ceiling other accessories.
Supplying & installation of rigid ISI marked 25 mm NB , PVC drain piping of minimum 4Kg/Sq. cm. of pressure rating for the ac units as per specifications including all accessories like bends, tees etc. as required.
Supplying and Charging of Refrigerant Gas after Pressure test and Vaccum test in Split AC units.
1.0 TR to 1.5 TR
Providing and fixing of rubber mat on floor, non skid type 1 meter wide and 2.5 mm thick to withstand 11KV dielectric strengh as per IS: 15652 as required including all fixing material like adhesive etc. completed in all respect.
Providing and fixing of rubber mat on floor, non skid type 1 meter wide and 2.0 mm thick to withstand 3.3KV dielectric strengh as per IS: 15652 as required including all fixing material like adhesive etc. completed in all respect.
Minor work Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Supplying and fixing following Modular base & cover plate on existing modular metal/PVC boxes etc. as required
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
RJ 45 single/double jack face plate
Supplying and fixing following Modular PVC boxes/Dado Trunking Box etc . in Surface etc.as required
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
Supplying and fixing following modular switch /socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
RJ-45 socket I/O
Supplying and fixing of following sizes of medium class, FRLS PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the exisitng surface or recessed steel/PVC conduit as required (also in existing metallic raceways)
3 x 1.5 sq.mm.
3 x 2.5 sq.mm.
3 x 4 sq.mm.
6 x 4 sq.mm.
3 x 6 sq.mm.
6 x 6 sq.mm.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit/trunking as required.
1 run of cable ( 4000 Metre for Minor work and 600 Metre for Maintenance work)
2 run of cable ( 700 Metre for Minor work and 200 Metre for Maintenance work)
3 run of cable
Supplying, installtion, testing and commissioning of UTP CAT6 RJ45 ethernet patch cord - 7 feet as per technical specification etc. as required.
Supplying, installtion, testing and commissioning of UTP CAT6 RJ45 ethernet patch cord - 3 feet as per technical specification etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying of 2'X2' Luminaire, 31W-38W recess mounting type LED luminaire, IP 20 ,colour temperature 4000/5700/6500 K having efficacy not less than 80 lm/W, CRI > 70 ,THD >10%, CRCA housing, suitable diffuser, inbuilt electronic driver, including 3 core 1.5 sq.mm FRLS PVC insulated and PVC sheathed copper conductor cable and earthing etc. upto suitable point complete as required.(Wipro CRCO10R038HP57GL1 or similar in Approved make list).
Supplying and fixing IP 65 Weather Proof 6 Module surface mounting MCB box, including transparent door and cabinet, removable chassis, din rail complete as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, DP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A, “C” curve, FP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 63 A, “C” curve, FP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with per phase isolation kit tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, IP 43, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 250 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCCBs/MCB (but without MCCBs/MCB at incomer & outgoing ) as required . (Note : Vertical type MCCB TPNDB is normally used where 3 phase outlets are required.). DB should be suitable to install MCCB at incomer and TPN/SP MCB at outgoing.
8 way Double door (4 + 24)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Triple pole
Supplying and fixing 40 to 63 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole
Four pole
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity 4 pole MCCB having adjustable thermomagnetic release with spreaders links in existing distribution board, making connections, etc. as required.
160 A,36KA,FPMCCB
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/ LED of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 16/25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40/63 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TPN sheet steel enclosure on surface/ recess along with 16/25/32 A, 415 V “C” curve TPN MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TPN sheet steel enclosure on surface/ recess along with 40/63 A, 415 V “C” curve TPN MCB complete with connections, testing and commissioning etc. as required.
Supplying of following sizes XLPE Insulated & PVC sheathed Copper conductor armoured power cable of 1.1 KV grade ISI marked conf. to IS : 7098 (Pt-1) etc. as required
4C X 16 Sqmm Copper conductor cable .
4C X 10 Sqmm Copper conductor cable .
4C X 6 Sqmm Copper conductor cable .
4C X 4 Sqmm Copper conductor cable .
3C X 6 Sqmm Copper conductor cable .
Supply and making indoor end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.
4C X 16 Sqmm Copper conductor cable .
4C X 10 Sqmm Copper conductor cable .
4C X 6 Sqmm Copper conductor cable .
4C X 4 Sqmm Copper conductor cable .
3C X 6 Sqmm Copper conductor cable .
Supplying of 3C x 2.5 sqmm copper flexible cable, heavy duty industrial cable 1100V PVC insulated & Sheathed with Bare Annealed Copper Conductor as per IS:694-1990 complete as required.
Supplying of following sizes XLPE Insulated & PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade ISI marked conf. to IS : 7098 (Pt-1) etc. as required
3.5C X 70 Sqmm Aluminium conductor cable .
3.5C X 35 Sqmm Aluminium conductor cable .
4C X 25 Sqmm Aluminium conductor cable .
4C X 16 Sqmm Aluminium conductor cable .
3C X 4 Sqmm Aluminium conductor cable .
Supply and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5C X 70 Sq. mm.
3.5C X 35 Sq. mm.
4C X 16 Sq. mm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm ms flat)
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1kV grade of following size in the existing RCC/Hume/Metal/DWC Pipe as required
Up to 35 sqmm
Above 35 sq. mm and upto 95 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray with cable tie as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying and fixing of 170 mm x 57 mm Dado cable management trunking 2 compartment with suitable joint for each compartment,internal & external corner,flat angles, flat tee,end cap & joint cover (coupler), cable retainer, separation partition as required. (Make:Honeywell)
Supplying and fixing of 100 mm x 50 mm UPVC cable management trunking with suitable joint for each compartment,internal & external angle,flat angles, flat tee, flat cross, end cap & joint cover, internal coupler, cable retainer, separation partition as required. (Make:Honeywell)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessedconduit/ submain wiring/ cable as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required.
Supplying and Fixing of Weather proof (Water tight IP-66) industrial type 32 AMP, 2P+E, 230 Volts plug and socket with DP MCB provision including interconnect etc. complete as required(Make:-Scame)
Supplying and fixing domastic standard socket 16 Amps with 16 Amps switch for industrial application IP 66 with water proof enclosure with suitable fixing arrangement as directed by Engr-in-charge
Supplying, installtion, testing and commissioning of UTP CAT6 24 ports capacity gigaspeed angular patch panel, all ports loaded with individual RJ-45 IOs. Any unused / unloaded ports should be masked with blank modules or blank IO inserts as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Layer 2 enterprise manageable networking switch,L2, 24 Port 1000base-Tx, Non-PoE, 4 SFP Ports with 3 year subscription as per technical specification etc. as required.(Make: Cisco C9200L-24T-4G-E)
Erection of 2.7 to 6 meter long MS paint of street light pole (having GI base plate of size 300mmx300mmx12mm thick, suitable for mounting of 1 no. street light fixture in cement concrete 1:3:6 (1 cement: 3 Coarse sand : 6 graded stone aggregate of 20 mm nominal size) foundation minimum size of 0.121 cum( 600 x 450 x 450 mm) including excavation and refilling etc. as required. Providing and fixing mild steel holding down Bolts with nutes and washer plates complete etc. as required. Installation,testing & commissioning of (20-70) Watt LED street light fixture, including wiring with 3X1.5 sqmm PVC insulated copper conductor wires from flush door to fixure etc. as required. Note: Pole and fixtures shall be issued free of cost to the contractor from department.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
SWASTIK ELECTROTECH PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .