| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.7 LAccepted-AOC | 1 | Accepted-AOC Agreement executed | |
| 2 | 2₹17.7 L+₹46,553.81 (2.70%)Rejected-Finance CHAKKITTAPARA KOZHIKODE DISTRICT KOYILANDI TALUK KERALA | 2 | Rejected-Finance 2nd lowest | |
| 3 | 3₹18.4 L+₹1.1 L (6.63%)Rejected-Finance | 3 | Rejected-Finance 3rd lowest | |
| 4 | 4₹20.3 L+₹3.1 L (18.2%)Rejected-Finance | 4 | Rejected-Finance 4th lowest |
Tender Value
₹18.6 L
EMD Value
₹46,579
Closing Date
14 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer
O/O the Assistant Engineer Kayakkody
Annual Plan-2022-23 KARINGAD MUNYODU DRINKING WATER PROJECT IN KAYAKKODY GP
2022_LSGD_525671_1
23/AE/LSGD/KYKD/ETENDER22
Open Tender
Civil Works - Buildings
Item Rate
Kayakody
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
Yes
₹46,579
Yes
5 Jan 2023
7 Nov 2022
16 Nov 2022
7 Nov 2022
14 Nov 2022
7 Nov 2022
Amount
WELL CONSTRUCTION
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
OD220824/2022-2023: Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.<br>All kinds of soil
OD220825/2022-2023:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.<br>All kinds of soil
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining
50.5.7:Reinforced cement concrete work in well-staining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1. 5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
PUMP HOUSE CONSTRUCTION
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
60.7.1:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
PIPE LAYING
OD230570/2022-2023:Excavating trenches of required width for pipes cables etc including excavation for sockets and dressing of sides ,ramming of bottoms ,depth up to 1.5 m ,including getting out the excavated soil . and then returning the soil as required in layers not exceeding 20 cm in depth ,including consolidating each deposited layer by ramming ,watering ,etc and disposing of surplus excavated soil as directed with in a lead of 50 m .all kinds of soil. Pipes cables etc not exceeding 80mm dia ( modified item 2.10.1.1)
OD231805/2022-2023:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement& testing of joints complete as per direction of Engineer in Charge. 75 mm dia 10 Kgf/ cm2 without trenching and refilling ( item 50.18.9.8.1 )
OD231806/2022-2023:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement,& testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2 without trenching and refilling ( item 50.18.9.8.1 )
OD231807/2022-2023:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6 Kgf/ cm2 without trenching and refilling ( MODIFIED 50.18.9.7.1,as per approved OD by EE LSGD KOZHIKODE )
OD230627/2022-2023:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2 (modified OD 50.18.9.6.1 without trenching, refilling )
OD230623/2022-2023:Providing and fixing PVC pipes including jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2 (modified OD 50.18.9.5.1 without trenching refilling, )
OD230622/2022-2023:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2 (modified OD 50.18.9.4.1 without trenching, refilling )
OD230630/2022-2023: Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2 (modified OD 50.18.9.3.2 without trenching and refilling )
OD230640/2022-2023:Providing and fixing PVC U ASTM pipe with socket and solvent cement testing of joints complete as per direction of Engineer in Charge. 65 mm dia 80 SW PVC -U ASTM pipe
OD230639/2022-2023:Providing and fixing . PVC -U ASTM pipe with socket and solvent cement, testing of joints complete as per direction of Engineer in Charge 65 mm dia 40 SW PVC -U ASTM pipe
OD231816/2022-2023:Providing street fountains with vertical posts by 75 mm PVC pipe 1.20m long fixed in concrete filled with cc 1:3:6 , 20 mm metal and erected on a cc platform for in 1:3:6 20mm metal , and connecting the taps in position including all cost conveyance etc. complete (cost of tap and connecting pipe should be paid separately)
OD230644/2022-2023:Providing and fixing PVC -U ASTM pipe with socket and solvent cement, testing of joints complete as per direction of Engineer in Charge. 40 mm dia 40 SW PVC -U ASTM pipe
18.54.1:Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not less than 88 gms
18.19.5.2:Providing and fixing gun metal non-return valve of approved quality (screwed end): 65 mm nominal boreVertical
OD230710/2022-2023:Providing and fixing PVC valve of approved quality 75 mm nominal bore (modified data of 18.17.5)
OD230709/2022-2023:Providing and fixing PVC valve of approved quality 50 mm nominal bore (modified data of 18.17.4)
ASHRAF. K.K.
sijinjith ap
RAGHUDASAN
Bidder Name
RAGHUDASAN
ASHRAF. K.K.
sijinjith ap
VIPINLALCHANDRAN
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_757572.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .