Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-Finance HATIBANDHA RAGHUNATHGANJ | DINAJPUR DAKSHIN | WEST BENGAL | 733101 | ₹2.5 Cr | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹2.5 Cr+₹2.0 L (0.81%)Rejected-Finance VILL P O NIMTITA DIST MURSHIDABAD PIN 742224 | NIMTITA | MURSHIDABAD | WEST BENGAL | 742224 | ₹2.5 Cr+₹2.0 L (0.81%) | L2 | Rejected-Finance Higher bid value |
| 3 | L3₹2.6 Cr+₹4.1 L (1.62%)Rejected-Finance 56 6BAKSARA ROAD PO BAKSARA HOWRAH HOWRAH 711110 WEST BENGAL INDIA | HOWRAH | HOWRAH | WEST BENGAL | 711110 | ₹2.6 Cr+₹4.1 L (1.62%) | L3 | Rejected-Finance Higher bid value |
| 4 | Rejected-Technical | - | - | Rejected-Technical TECHNICALY NOT QUALIFIED |
| Sl No | Description | Qty | Unit | M/S ROY TRADING CO. L3 | SATELLITE CONSTRUCTION L1 | BIJAY CHOWDHURY L2 |
|---|---|---|---|---|---|---|
| 1.00Providing House Service connection from the existing CI/DI/UPVC/HDPE/GI/AC distribution pipeline by supply,fitting & fixing of 10 mm NB Brass Ferrule conforming to lS 2692:1989 with latest amendments on the said pipeline with supply, fitting & flxing of all other accessories like saddle piece of required size to fit the existing distribution pipeline, specials, nut & bolts, rubber sheet, washers etc and supply & laying of 20mm OD HDPE (PE100, PN16) pipe with all necessary specials 1.0 metre below (approx.) the ground connecting the ferrule/flow control valve including cutting trenches in all sorts of soil as well dismantling of any hard crust layer/concrete/masonry etc.(average 0.15 cum for each 1205 nos. & Avg. 0.30 cum. for each 2812 nos. of connections respectively.) and filling up trenches as per direction of the Engineer-in-charge and upto a point just inside the premises of the household or as directed by ElC. Supply and installation of a 15mm dia. alloy iron Bib Cock (tested to 21 Kg/cm2) above 1.0 Mtr. from ground, an alloy Stop Cock of 15 mm dia. with brass spindle (tested to 21 Kg/cm2) to be fitted in a position as directed by E.l.C. G.l pipe of TATA make (medium duly) of 2 metre length with all necessary specials to continue from the end of the HDPE pipe & upto 1.0 m. above ground within the premises of household including Supply , Fitting and Fixing of Multi Jet Class- B domestic/commercial water metering system (size 15 mm) strictly conform to IS 779-1994 (with all amendements) or MID with AMR compatibility as per specification in the NIeB/NIeT with PE meter box and with NRV valve as specified as per direction of EIC along with periodcial meter reading and submission of reports as mentioned in the scope of work as well as per direction of EIC. Casing Pipe of 25mm dia (TATA MAKE GI PIPE MEDIUM DUTY) to be provided by the contractor for crossing of drain if any. All the damages made on the roads, the compound walls etc. for providing House service connection shall have to be restored by the Plain cement concrete (1:2:4) by the contractor as per direction of EIC. Any damages made on the floor / PCC / tiled / mosaic etc. shall be restored by the Contractor with Plain Cement Concrete (PCC 1:2:4) and neat cement finish as per direction of EIC. N.B.-GST will be applicable as per Govt.norms | ||||||
| 1.01 | Upto 10m length of HDPE pipe from the distribution pipe line | 938 | Nos | 77,38,500 ₹77,38,500 | 75,39,644 ₹75,39,644 Lowest | 76,44,700 ₹76,44,700 |
| 1.02 | Above 10m Upto 20m length of HDPE pipe from the distribution pipe line | 2,190 | Nos | 1,78,48,500 ₹1,78,48,500 | 1,76,40,450 ₹1,76,40,450 Lowest | 1,77,39,000 ₹1,77,39,000 |
Tender Value
Refer Docs
EMD Value
₹3 L
Closing Date
7 Mar 2025, 6:00 pmClosed
Executive Officer of Jangipur Municipality
PAKURTALA, RAGHUNATHGANJ, MURSHIDABAD
House service water Connection with saddle to 3128 nos. of Premises at different wards up to private property line with 20mm OD HDPE with necessary connection accessories including Water Meter and restoration of damages of road at ZONE-A
2025_MAD_811305_1
03/AMRUT-2.0/JM/SE(CC)/2024-25
Open Tender
CIVIL WORKS
Item Wise
180 days
ZONE-A, JANNGIPUR
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹3 L
Yes
20 Sept 2026
8 Feb 2025
10 Mar 2025
8 Feb 2025
7 Mar 2025
12 Feb 2025
Providing House Service connection from the existing CI/DI/UPVC/HDPE/GI/AC distribution pipeline by supply,fitting & fixing of 10 mm NB Brass Ferrule conforming to lS 2692:1989 with latest amendments on the said pipeline with supply, fitting & flxing of all other accessories like saddle piece of required size to fit the existing distribution pipeline, specials, nut & bolts, rubber sheet, washers etc and supply & laying of 20mm OD HDPE (PE100, PN16) pipe with all necessary specials 1.0 metre below (approx.) the ground connecting the ferrule/flow control valve including cutting trenches in all sorts of soil as well dismantling of any hard crust layer/concrete/masonry etc.(average 0.15 cum for each 1205 nos. & Avg. 0.30 cum. for each 2812 nos. of connections respectively.) and filling up trenches as per direction of the Engineer-in-charge and upto a point just inside the premises of the household or as directed by ElC. Supply and installation of a 15mm dia. alloy iron Bib Cock (tested to 21 Kg/cm2) above 1.0 Mtr. from ground, an alloy Stop Cock of 15 mm dia. with brass spindle (tested to 21 Kg/cm2) to be fitted in a position as directed by E.l.C. G.l pipe of TATA make (medium duly) of 2 metre length with all necessary specials to continue from the end of the HDPE pipe & upto 1.0 m. above ground within the premises of household including Supply , Fitting and Fixing of Multi Jet Class- B domestic/commercial water metering system (size 15 mm) strictly conform to IS 779-1994 (with all amendements) or MID with AMR compatibility as per specification in the NIeB/NIeT with PE meter box and with NRV valve as specified as per direction of EIC along with periodcial meter reading and submission of reports as mentioned in the scope of work as well as per direction of EIC. Casing Pipe of 25mm dia (TATA MAKE GI PIPE MEDIUM DUTY) to be provided by the contractor for crossing of drain if any. All the damages made on the roads, the compound walls etc. for providing House service connection shall have to be restored by the Plain cement concrete (1:2:4) by the contractor as per direction of EIC. Any damages made on the floor / PCC / tiled / mosaic etc. shall be restored by the Contractor with Plain Cement Concrete (PCC 1:2:4) and neat cement finish as per direction of EIC. N.B.-GST will be applicable as per Govt.norms
Upto 10m length of HDPE pipe from the distribution pipe line
Above 10m Upto 20m length of HDPE pipe from the distribution pipe line
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .