Loading…
Loading…
Tender Value
₹1.3 Cr
EMD Value
₹2.5 L
Closing Date
1 Jun 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less; Where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The contractor should have a valid Electrical contractor license issued by Govt. and submit along with tender documents. The OEM or his authorized dealer will be exempted from license. If tenderer fails to submit a valid electrical contractor license then offer from the tenderer will be summarily rejected
Any electrical work related to LT/HT installation.
"(a)The tenderer must have successfullycompleted/substentially completed any of thefollowing during last 07 (seven) years, endinglast day of month previous to the one in whichtender is invited: (i)Three similar works eachcosting not less than the amount equal to 30% ofadvertised value of the tender, or (ii) Two similarworks each costing not less than the amountequal to 40% of advertised value of the tender, or(iii) One similar work each costing not less thanthe amount equal to@10<37@ of advertised value ofthe tender. (b) (i) In case of composite works(e.g. works involving more than one distinctcomponent, such as Civil Engineering works, S&Tworks, Electrical works, OHE works etc. and inthe case of major bridges - substructure,superstructure etc.), tenderer must havesuccessfully completed/substantially completedany of the following during last 07 (seven) years,ending last day of month previous to the one inwhich tender is invited: Three similar works eachcosting not less than the amount equal to 30% ofadvertised value of each component of tender, orTwo similar works , each costing not less than theamount equal to 40% of advertised value of eachcomponent of tender, ora One similar work, eachcosting not less than the amount equal to 60% ofadvertised value of each component of tender.Note: Separate completed works of minimumrequired values for each component can also beconsidered for fulfillment of technical eligibilitycriteria. (b) (ii) In such cases, what constitutes acomponent in a composite work shall be clearlypre-defined with estimated tender cost of it, aspart of the tender documents without anyambiguity. Any work or set of works shall beconsidered to be a separate component, onlywhen cost of the component is more than Rs. 2crore each. The tenderer shall submit thecompletion certificate as per proforma given inannexure-IV-A or IV-B or IV-C as applicable or inthe format containing all information as requiredas per the Annex. IVA or IV-B or IV-C. Note :-Criteria for the completed work/Substantiallycompleted has been given in the Generalinstructions in the tender document. "s
73 conditions · 12 needing a document upload
Mandatory in case Bid Security amount is prescribed in clause no. 5.1.2 of General Instructions of Standard Tender Document (Version 11.4) for IREPS - The Bid Security shall be deposited in cash through e-payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure-XXXII and shall be valid for a period of 90 days beyond the bid validity period.
In case the tenderer is (i) Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' - shall be exempted from payment of Bid Security deposit and shall submit certified copy of the registration/ Valid document issued by DIPP (mandatory if applicable).
In case the tenderer is (iii) Labour Cooperative Societies - shall deposit only 50% of the Earnest Money / Bid Security Deposit and shall submit certified copy of the registration/ Valid document issued by the relevant Ministry/ Labour commission (mandatory if applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
In case the tenderer is (i) Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' - shall be exempted from payment of Bid Security deposit and shall submit certified copy of the registration/ Valid document issued by DIPP (mandatory if applicable).
In case the tenderer is (iii) Labour Cooperative Societies - shall deposit only 50% of the Earnest Money / Bid Security Deposit and shall submit certified copy of the registration/ Valid document issued by the relevant Ministry/ Labour commission (mandatory if applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The Minimum Increment as mentioed in the Clause no. 26.1 (b), Annexure C, Para 2 of the "GENERAL INSTRUCTIONS" of Tender Document will be as per railway board guidelines or as approved by Tender accepting authority . (Applicable to the works and service tenders of value more than Rs.50 crore.)
I/We have read the various conditions to tender attached here to and agree to abide by the said conditions. I/We also agree to keep this tender open for acceptance for a period as mentioned in NIT header from the date fixed for opening the same and in default thereof, I/We will be liable for forfeiture of my/our "Bid security". I/We offer to do the work for North Western Railway, at the rates quoted in the attached schedule and hereby bind myself/ourselves to complete the work in all respects within time period as mentioned in the NIT Header from the date of issue of letter of acceptance of the tender.
I/We also hereby agree to abide by the General Conditions of Contract-2022 corrected up- to- date and to carry out the work according to the Special Conditions of Contract and Indian Railways Unified Standard Specifications (Materials and Works) 2021 as corrected up-to-date, Unified Standard Schedule of Rates of North-Western Railway - 2021 as corrected up-to-date & CPWD DSR-2021 and Specification 2019 (for the present contract)
Electrical work, utility shifting & power line track crossing etc. work at new line of marwar junction by pass & Ramdevra - Pokhran station over jodhpur division.
ELCJU-G-MJ-RDRAPOK2526-5R
ELCJU-G-MJ-RDRAPOK2526-5R
Open
Works - General
12 Months
Jodhpur, Rajasthan
₹0
₹2.5 L
1 Jun 2026
4 May 2026
18 May 2026
172 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,26,81,809.11 | ||
| — | 17.00 | — | — | ||
| To draw the site plan of HT/LT track crossing on tracing paper of 85/90 GSM showing details of crossings, DP/Tower., RCC /CI / HDPE pipe, cable with depth and bank height and other details & Certificates etc. as per railway requirement and same is to be got signed by Railway & related state electricity authorities before execution of work, each tracing is to be supplied with 12 copies of ammonia print. As per specification. | — | — | — | 42,832.52 | |
| — | 17.00 | — | — | ||
| To get printed the agreement on Rs.500/- Non-Judicial stamp paper as per standardized proforma of railway track crossing regulation 1987 in Hindi & English (6 copies of each) with proper drawing etc. As per specification | — | — | — | 34,708.73 | |
| — | 17.00 | — | — | ||
| Preparation of paper by printed the way leave agreement on Rs.500/- Non-Judicial Stamp paper for getting EIG sanction as per standardized proforma of railway for each crossing before execution of work. As per specification. | — | — | — | 10,421.85 | |
| — | 12.00 | — | — | ||
| Inspection, testing and examination fees of upto 11KV line, busbar and cables per circuit for energisation permission. As per specification. | — | — | — | 2,619.84 | |
| — | 5.00 | — | — | ||
| Inspection, testing and examination fees of exceeding 11 KV & up to 33 KV line, busbar and cables per circuit for energisation permission. As per specification. | — | — | — | 6,556 | |
| — | 4200.00 | — | — | ||
| Supply and laying of HDPE pipe conforming to IS 4984:1995, 160 mm dia, under road / ground/floor/railway track or as per site requirement in already excavated trench. As per specification. | — | — | — | 18,18,810 | |
| — | 34.00 | — | — | ||
| Supply & erection of 12.8Mtr. Long lattice tower made of 65 x 65 x 5mm MS angle with 50 x 6mm MS flat for bracing including excavation of pit 1.50 x 1.50 x 2.10M in ground. As per specification. | — | — | — | 14,17,822.44 | |
| — | 68.00 | — | — | ||
| Fabrication, supply & installation of cable route marker for HT/LT underground cable as per Drg.No. EL/ CEE /2016 /03. As per specification. | — | — | — | 11,227.48 | |
| — | 34.00 | — | — | ||
| To make termination point on existing Rail/ PCC/ 'H' Pole/ Tower etc. As per specification. | — | — | — | 22,535.2 | |
| — | 5.00 | — | — | ||
| Supply, fixing & commissioning of 09 mtrs. long PCC pole for LT/11 KV for making cut point at 90 degree or realigning existing line. As per specification. | — | — | — | 16,578.95 | |
| — | 20.00 | — | — | ||
| Dismantling & deposited released material of existing HT/LT overhead crossing/span complete in all respect & connecting HT/LT XLPE cable to the system. As per specification. | — | — | — | 10,603.4 | |
| — | 70.00 | — | — | ||
| Supply, installation and erection of stay rod complete As per specification. | — | — | — | 43,165.5 | |
| — | 234.00 | — | — | ||
| Supply, erection, testing and commissioning of 11/33 KV Disc/Pin insulator on SP /DP / Tower. As per specification. | — | — | — | 86,828.04 | |
| — | 40.00 | — | — | ||
| Supply and fixing of 50 mm internal dia "B" class G.I. pipe as per IS-1239 for cable laying with pole/ wall / under road /floor etc. As per specification. | — | — | — | 9,223.2 | |
| — | 144.00 | — | — | ||
| Supply & fixing of GI pipe having internal dia 100mm medium duty. As per specification. | — | — | — | 72,216 | |
| — | 60.00 | — | — | ||
| Supply & fixing of GI pipe having internal dia 150mm medium duty. As per specification. | — | — | — | 37,017 | |
| — | 48.00 | — | — | ||
| Supply, erection, testing & commissioning of outdoor type cable end boxes suitable for 11 KV 'E' 3 core 185 Sq.mm XLPE. As per specification. | — | — | — | 4,47,272.64 | |
| — | 4.00 | — | — | ||
| SITC of heat shrinkable type Straight through joint for 11 KV 'E' 3 core HT XLPE 185 Sq. mm Cable as per specification. | — | — | — | 45,120.48 | |
| — | 20.00 | — | — | ||
| Supply, erection, testing & commissioning of outdoor type cable end boxes suitable for 33 KV 'E' 3 core 300 Sq.mm XLPE. As per specification. | — | — | — | 2,71,162 | |
| — | 2.00 | — | — | ||
| SITC of heat shrinkable type Straight through joint for 33 KV 'E' 3 core HT XLPE 300 Sqmm Cable. | — | — | — | 43,339.08 | |
| — | 4250.00 | — | — | ||
| "Excavation & refilling of trench size 0.5m wide x 1.2 m deep as per specification. Trench work may be on kuchha/pucca land and all type of soil as per site requirement and without protective layer of bricks. Surface of trench shall be made good in all respect and upto satisfaction of site engineer." | — | — | — | 5,39,580 | |
| — | 12000.00 | — | — | ||
| Laying, testing, commissioning & transportation of LT cable in Air/ Pole /Pipe /wall/cable tray etc. with complete lugs/ glands and transportation of cable etc. Note- Cable will be supplied by Rly. from main depot. As per specification. | — | — | — | 2,45,040 | |
| — | 4500.00 | — | — | ||
| Laying, testing, commissioning & transportation of 11/33KV HT cable in Air/ Pole/ Pipe/ Trench etc. Note- Cable will be supplied by Rly. from main depot. As per specification. | — | — | — | 3,84,390 | |
| — | 300.00 | — | — | ||
| Digging and filling of trench size 0.5 x 1.2 mtr in hard rock ( where blasting is prohobited) for laying of pipe etc. for UG cable | — | — | — | 1,14,393 | |
| — | 100.00 | — | — | ||
| "Supply of material and providing of earth electrode for earthing by using medium grade, 50 mm GI pipe electrode 3mtr. long, 7/4mm dia galvanized steel stranded wire including connections from earth pipe to pole. As per specification " | — | — | — | 1,21,291 | |
| — | 6.00 | — | — | ||
| SITC of LT cable heat shrinkable type Straight through joint kit for 4 core LT XLPE Cable. | — | — | — | 14,602.08 | |
| — | 80.00 | — | — | ||
| Supply and fixing of MS Channel 100x50x6 mm for termination with clamps, nuts, bolts and washers etc. including primer coat of red oxide and two coats of aluminium paints. As per specification. | — | — | — | 5,083.2 | |
| — | 2.00 | — | — | ||
| Supply of material , fabrication, errectionof H pole ( double pole ) with I section MS beam ISHB size 150 x 150 mm of length 10 meter with required foundation & paintimh etc. As per drawing Dy. CEE / C / JP for 11 Kv / 33 KV system as per specification. | — | — | — | 49,774.34 | |
| — | 30.00 | — | — | ||
| Measurement of HT / EHT lines as per spec. | — | — | — | 61,179 | |
| — | 400.00 | — | — | ||
| Drilling of horizontal bore below Rly track by pushing method for laying of HDPE/SPUN/DWC pipe of various sizes up to 450 mm dia. As per specification. | — | — | — | 10,68,468 | |
| — | 40.00 | — | — | ||
| Dismantling of existing LT poles with fitting / oh wire | — | — | — | 20,302 | |
| — | 5.00 | — | — | ||
| Dismantling / shifting of existing lattice LED light tower / High mast | — | — | — | 1,35,995.1 | |
| — | 2.00 | — | — | ||
| Dismantling of .44 / 11 / 33 KV transformer from DP / FP / other location including shifting & reinstallation | — | — | — | 29,921.14 | |
| — | 400.00 | — | — | ||
| Recessed/Surface conduit wiring system-Supply of material and wiring of LP/TP/FP/Exhaust fan/ Bell point with single core multistrend copper conductor size 1.5 Sq.mm in PVC conduit pipe with 5/6 Amp modular type switch / ceiling rose/batten holder etc.. As per specification . | — | — | — | 1,37,936 | |
| — | 150.00 | — | — | ||
| Supply and installation of 5/6Amp plug modular 5 pin 230 V. socket including modular switch & with modular board & wiring with 2.5 sq. mm PVC CU cable as per specification | — | — | — | 34,576.5 | |
| — | 110.00 | — | — | ||
| Supply and intallation of , 15/16Amp. Plug, modular 5 pin 230 V including modular switch & with modular board & wiring with 4.0 Sq. mm PVC CU cab;e as per specification | — | — | — | 29,240.2 | |
| — | 60.00 | — | — | ||
| Supply & fixing 2 module modular switch board plate for fixing of modular switches - plug with sheet metal box of good quality concealed fixing of MS / PVC as per site Engineer. | — | — | — | 6,766.2 | |
| — | 80.00 | — | — | ||
| Supply & fixing 4 module modular switch board plate for fixing of modular switches - plug with sheet metal box of good quality concealed fixing of MS / PVC as per site Engineer. | — | — | — | 13,237.6 | |
| — | 120.00 | — | — | ||
| Supply & fixing 6 module modular switch board plate for fixing of modular switches - plug with sheet metal box of good quality concealed fixing of MS / PVC as per site Engineer. | — | — | — | 23,413.2 | |
| — | 60.00 | — | — | ||
| Supply & fixing 8 module modular switch board plate for fixing of modular switches - plug with sheet metal box of good quality concealed fixing of MS / PVC as per site Engineer. | — | — | — | 16,867.2 | |
| — | 60.00 | — | — | ||
| Supply & fixing 12 module modular switch board plate for fixing of modular switches - plug with sheet metal box of good quality concealed fixing of MS / PVC as per site Engineer. | — | — | — | 18,885.6 | |
| — | 1200.00 | — | — | ||
| Supply, laying, connection and commission of sub-main 2x2.5 Sqmm with PVC insulated single core copper conductor cable and same size PVC insulated copper conductor for earthing wire in 19/20 mm ISI PVC conduit in recessed/ on surface as per site requirement etc. of various size cable as below. As per specification | — | — | — | 72,756 | |
| — | 1100.00 | — | — | ||
| Supply, laying, connection and commission of sub-main 2x4 Sqmm with PVC insulated single core copper conductor cable and same size PVC insulated copper conductor for earthing wire in 19/20 mm ISI PVC conduit in recessed/ on surface as per site requirement etc. of various size cable as below. As per specification | — | — | — | 1,14,719 | |
| — | 600.00 | — | — | ||
| Supply, laying, connection and commission of sub-main 2x6.0 Sqmm with PVC insulated single core copper conductor cable and same size PVC insulated copper conductor for earthing wire in 19/20 mm ISI PVC conduit in recessed/ on surface as per site requirement etc. of various size cable as below. As per specification | — | — | — | 68,832 | |
| — | 300.00 | — | — | ||
| Supply, laying, connection and commission of sub-main 2x 10 Sqmm with PVC insulated single core copper conductor cable and same size PVC insulated copper conductor for earthing wire in 19/20 mm ISI PVC conduit in recessed/ on surface as per site requirement etc. of various size cable as below. As per specification | — | — | — | 77,130 | |
| — | 60.00 | — | — | ||
| Installation /shifting testing and connection of ceiling fans (Fans will be supplied by Railway). As per specification | — | — | — | 4,298.4 | |
| — | 60.00 | — | — | ||
| Supply & Fixing ceiling of fan regulator electronic type 5 step As per specification. | — | — | — | 20,433.6 | |
| — | 25.00 | — | — | ||
| Supply, fixing & commissioning of 300 mm sweep exhaust fan with louver shuter. As per specification. | — | — | — | 34,201.75 | |
| — | 15.00 | — | — | ||
| SFT&C of SPN Distribution Board double door 8 way (8+2 modules), netural and earth link with one no. DP MCB 40A Amp., one no. DP RCCB 40 Amp., 30 mA as incoming and 6 Nos outgoing SP MCB 6/10/16/20/25/32 Amp. 'C' Series, Breaking capacity not less than 10kA. MCB, RCCB & DB should be same make & as per specification. | — | — | — | 92,161.95 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of MCB distribution box TPN double door and suitable IP protection with incoming 01 No.63A, 100mA sensitivity, 4-pole RCCB and outgoing 18 nos. MCB 6-32A single pole. As per specification. | — | — | — | 9,850.42 | |
| — | 70.00 | — | — | ||
| Fixing, testing & commissioning of LED street light complete (Fitting supplied by Rly. & transported by Contractor). As per Specification. | — | — | — | 7,051.8 | |
| — | 70.00 | — | — | ||
| Supply, fabrication, erection, testing and commissioning of G.I. octagonal pole 5 meters long single arm suitable for street light fixture including digging of pit, making foundation and muffing with cement, concrete concrete 1 : 3 : 6. As per Specification. | — | — | — | 6,94,164.1 | |
| — | 100.00 | — | — | ||
| Fixing, testing & commissioning o f LED tube light fitting as per spec. ( Complete fitting will be supplied by Rly. & transported by the contractor). As per Specification. | — | — | — | 7,181 | |
| — | 2500.00 | — | — | ||
| Supply and laying of HDPE pipe conforming to IS 4984:1995, 50 mm dia wall thickness 3 mm under the road/PF/ in groung or as per site requirement. As per specification. | — | — | — | 2,57,275 | |
| — | 4.00 | — | — | ||
| Feeder Pillar :Supply,install, testing and commissiong of of out door feeder pillar junction box with aluminium bus bar 30 mm x 10 mm & out going feeder 63A, 4 P MCB( 2 Nos.)& 32 A 2 pole C curve MCB ( 04 Nos. ) as per specification | — | — | — | 69,137.48 | |
| — | 8000.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec. ( trench work may be on kuchha / pucca land and all type of soil as per site requirement and without protective layer of brick ) as per specification | — | — | — | 3,58,560 | |
| — | 80.00 | — | — | ||
| Supply and fixing metal clad plug socket 20A single phase with 32A MCB including fixing and sheet metal enclosure box with one 20A plug top (Ray roll type) to be supplied with board. As per specification | — | — | — | 67,723.2 | |
| — | 12.00 | — | — | ||
| SITC of single phase electronic meter 0-20 Amp.As per specification | — | — | — | 13,194.36 | |
| — | 12.00 | — | — | ||
| SITC of meter box for single phase meter PVC/M.S. with two no. single pole MCB. As per specification | — | — | — | 7,534.68 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of VTPN DB 4 way having incoming 01 No. 125 Amp 4 Pole MCCB 36KA and outgoing 04 Nos. TP MCB 40/63 Amp 'C' Curve 10KA as required make from reference list. As per specification. | — | — | — | 40,553.62 | |
| — | 4.00 | — | — | ||
| Supply installation Testing & Commissioning of 4 pole MCCB 125 Amp. 36 KA in double door enclosure. | — | — | — | 30,941.24 | |
| — | 3.00 | — | — | ||
| SITC of 2.0 HP/1.5KW mono-block submerssible pump, as per specification. | — | — | — | 44,911.83 | |
| — | 4.00 | — | — | ||
| Supply, erection, testing and commissioning of 16 M high mast shaft totally hot dip galvanized and suitable for wind velocity as per IS 875 part-3. The mast shaft shall be in two finished section it shall also included all accessories for 16M high mast | — | — | — | 8,76,520.48 | |
| — | 4.00 | — | — | ||
| Design and casting of suitable foundation with M-20 concrete for the 16mtr high mast having the safe soil bearing capacity at site as 10T/sqmtr at 2 meter depth including supply of foundation bolts manufactured from special steel along with nuts, washers and anchor plates and templates and as per specification enclosed. | — | — | — | 87,622.84 | |
| — | 32.00 | — | — | ||
| Supply and fixing of 150/160 W or above LED Floodlight comprising Die cast aluminium housing with toughened glass complete with Electronic driver, Luminaries has the System lumen efficacy of 100 lumen/Watt as per spec | — | — | — | 6,52,632.32 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing, commissioning of LED Aviation light luminaries Model no. BGAV 302 LED of Bajaj or similar | — | — | — | 31,519.36 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing and commissioning of control panel housing suitable timer control circuit for automatic ON & OFF of the 25/16 mtr. mast lights at a pre-set time and as per specification enclosed. | — | — | — | 47,781.76 | |
| — | 10.00 | — | — | ||
| Solar Based Street Light Power output of PV Module 75 Wp, Battery capacity 12.8 V as per specification | — | — | — | 2,40,897 | |
| — | 20.00 | — | — | ||
| — | — | — | 1,32,122.2 | ||
| Design,Manufacturer,Supply, LED based station Name | : - of specification | — | locations given size of | ||
| — | 6.00 | — | — | ||
| Temporary lighting arrangement of gumties, yard/points at the time of complete NI work As per specification. | — | — | — | 1,23,797.88 | |
| — | 10.00 | — | — | ||
| Supply, fixing and commissioning of street light fitting accessories i.e. GI pipe of suitable boar/size as per fitting, clamps, nuts, bolts, cable/wire etc. As per specification. | — | — | — | 1,527.7 | |
| — | 20.00 | — | — | ||
| Supply & fixing of backelite sheet 6 mm thick with suitable reg bolt, fastners & proper fixing in all respect | — | — | — | 2,688.4 | |
| — | 5.00 | — | — | ||
| Supply & fixing of mobile / laptop / computer point consisting of 4 Nos. 5/6 Amp. Switch socket | — | — | — | 1,931.1 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of load bank/LT panel board with 1x100 Amp MCCB in the incoming and 4x63 Amp MCCB in the outgoing. As per specification. | — | — | — | 73,083.04 | |
| — | 18.00 | — | — | ||
| Supply & installation of Air cooled VRF Hi-wall type indoor unit 1.5/2.0itycontrol complete with indoor &outdoor units, as per detailgiven in specifications andhaving following items :Refrigerant to be used shall beR-410 a. modular type topdischarge outdoor unitequipped with highly efficientmulti scroll/twin rotarycompressors with fullyinverter, with multi invertertype compressor & suitable for320 V-460V 50Hz. condensingunit to constitute required HPsystem (outdoor unitconfiguration/capacity will betaken as per railwayrequirement) circuit to reducethe redundancy ofcompressor, special heatexchanger, low noisecondenser fan with DCvariable speed motor, autoaddress setting , auto check function for connection error,with sandwich type vibrationisolator rubber pads, autoaddress setting and capacityas mentioned below, outdoorunit (nominal capacitydelivered at 430 C ) as perspecification (cooling & heating operations) As per specification (1 HP= 1 Nos.) | — | — | — | 4,16,073.24 | |
| — | 6.00 | — | — | ||
| Supply & installation of Air cooled VRF Hi-wall type indoor unit 1.5/2.0 TR As per specification | — | — | — | 1,70,517.24 | |
| — | 3.00 | — | — | ||
| SITC of cordless remote controller As per specification | — | — | — | 2,781.57 | |
| — | 12.00 | — | — | ||
| SITC of copper distribution joint kit As per specification | — | — | — | 61,855.32 | |
| — | 30.00 | — | — | ||
| SITC of control cabling: Supply & installation of control & transmission wiring between indoor & outdoor unit As per specification | — | — | — | 4,404.3 | |
| — | 30.00 | — | — | ||
| SITC of Refrigerant piping: Supply & installation of copper refrigerant piping of required sizes with nitrile insulation As per specification | — | — | — | 37,782 | |
| — | 45.00 | — | — | ||
| Drain piping ; SITC of rigid PVC piping complete with fitting, supports & duly insulated nitrile rubber insulation 32 mm dia As per specification | — | — | — | 9,539.1 | |
| — | 30.00 | — | — | ||
| Drain piping ; SITC of rigid PVC piping complete with fitting, supports & duly insulated nitrile rubber insulation 25 mm dia As per specification | — | — | — | 5,681.7 | |
| — | 2.00 | — | — | ||
| Supply of gas charging refrigerant R- 410 a as per OEM design parameter ( each cylinder gas 45 Kg) & testing As per specification | — | — | — | 64,397.04 | |
| — | 3.00 | — | — | ||
| SITC of MS stands As per specification | — | — | — | 11,373.69 | |
| — | 1.00 | — | — | ||
| SFTC of micro processor based energy efficient sequence AC controller for controlling simultaneous running of 3 Nos. AC's which work on 230 V , 50 Hz AC supply | — | — | — | 11,666.69 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCAdvanceCorrectionSlipNo11.pdf GCC ADVANCE CORRECTION SILIP 11
ATTACHMENT
STDPOKRADA114.pdf
ATTACHMENT
SOR.pdf
ATTACHMENT
TECHNICALSPECIFICATION.pdf
ATTACHMENT
SPECIALCONDITION.pdf
ATTACHMENT
GCC-2022ACS1to101.pdf
ATTACHMENT
GCCApril-2022_1.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .