| 1 | L1₹35.3 LAccepted-AOC NO 2 GF AKSHAYRAJ APARTMENT JUBILEE CIRCLE BHUJ 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹36.9 L+₹1.7 L (4.75%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹38.8 L+₹3.5 L (10.0%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance L3 | |
| 4 | L4₹39.3 L+₹4.1 L (11.5%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L4 | Rejected-Finance L4 | |
| 5 | L5₹39.9 L+₹4.6 L (13.1%)Rejected-Finance 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | rajengineers L2 | MONA GENERATOR SEVICES PVT. LTD. L8 | Sukhi Electricals L6 | M/s SK Traders L4 | jagdish machinery stores L3 | S t modi L9 | fakhrie apostrical L7 | M/s. Ambabhai K patel L1 | MADHAV ENTERPRISE L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings;mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with all accessories complete all as specified as directed by Engineer in Charge comprising the following:- | 8 | EACH | 64,000 ₹5,12,000 | 72,097 ₹5,76,776 | 65,000 ₹5,20,000 | 60,500 ₹4,84,000 | 63,000 ₹5,04,000 | 80,175 ₹6,41,400 | 75,680 ₹6,05,440 | 67,500 ₹5,40,000 | 59,500 ₹4,76,000 Lowest |
| 1.01(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 300 Amps for phases and 150 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iii) Panel board internal wiring with suitable rated PVC insulated copper conductors. (iv) MCCB 160 Amps,415V, 4 Pole, 25 KA - 01 No (In coming) (v) MCCB 63 Amps, 415V, 4 pole, 16 KA - 04 Nos (Out going) | ||||||||||||
| 2.00 | Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with all accessories complete all as specified as directed by Engineer in Charge comprising the following:- | 3 | EACH | 1,06,000 ₹3,18,000 | 1,12,471 ₹3,37,413 | 1,35,000 ₹4,05,000 | 1,03,000 ₹3,09,000 | 1,20,000 ₹3,60,000 | 1,24,500 ₹3,73,500 | 1,24,000 ₹3,72,000 | 90,000 ₹2,70,000 Lowest | 1,12,500 ₹3,37,500 |
| 2.01(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iii) Panel board internal wiring with suitable rated PVC insulated copper conductors. (iv) MCCB 315 Amps,415V, 4 Pole, 35 KA - 01 No (In coming) (v) MCCB 100 Amps, 415V, 4 pole, 25 KA - 06Nos (Out going) | ||||||||||||
| 3.00 | Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings;mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with all accessories complete all as specified as directed by Engineer in Charge comprising the following:- | 8 | EACH | 59,000 ₹4,72,000 | 66,821 ₹5,34,568 | 60,000 ₹4,80,000 | 50,900 ₹4,07,200 | 54,000 ₹4,32,000 | 69,850 ₹5,58,800 | 69,825 ₹5,58,600 | 42,000 ₹3,36,000 Lowest | 50,500 ₹4,04,000 |
| 3.01(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 250 Amps for phases and 125 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iii) Panel board internal wiring with suitable rated PVC insulated copper conductors. (iv) MCCB 125 Amps,415V, 4 Pole, 25 KA - 01 No (In coming) (v) MCCB 63 Amps, 415V, 4 pole, 25 KA - 03Nos (Out going) | ||||||||||||
| 4.00 | Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings;mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with complete all as specified as directed by Engineer in Charge comprising the following:- | 6 | EACH | 66,000 ₹3,96,000 | 73,256 ₹4,39,536 | 75,000 ₹4,50,000 | 85,000 ₹5,10,000 | 67,500 ₹4,05,000 | 79,950 ₹4,79,700 | 80,500 ₹4,83,000 | 60,000 ₹3,60,000 Lowest | 85,000 ₹5,10,000 |
| 4.01(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iii) Panel board internal wiring with suitable rated PVC insulated copper conductors. (iv) MCCB 250 Amps,415V, 4 Pole, 25 KA - 01 No (In coming) (v) MCCB 100 Amps, 415V, 4 pole, 25 KA - 03Nos (Out going) | ||||||||||||
| 5.00 | Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings;mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with complete all as specified as directed by Engineer in Charge comprising the following:- | 2 | EACH | 1,45,000 ₹2,90,000 | 1,50,440 ₹3,00,880 | 1,35,000 ₹2,70,000 | 1,20,000 ₹2,40,000 | 1,32,000 ₹2,64,000 | 1,78,349 ₹3,56,698 | 1,69,850 ₹3,39,700 | 95,000 ₹1,90,000 Lowest | 1,20,000 ₹2,40,000 |
| 5.01(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iii) Panel board internal wiring with suitable rated PVC insulated copper conductors. (iv) MCCB 315 Amps,415V, 4 Pole, 35 KA - 01 No (In coming) (v) MCCB 63 Amps, 415V, 4 pole, 25 KA - 10Nos (Out going) | ||||||||||||
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
8 Nov 2025, 6:00 pmClosed
Lt Col Sumukh Swaroop
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
REPAIR/ REPLACEMENT OF LT PANELS WITH ALLIED WORKS AT VARIOUS LOCATIONS UNDER GE (AF) JAMNAGAR NO 1
2025_MES_736057_1
8372/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
JAMNAGAR
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No 1
₹88,000
Yes
13 Dec 2025
18 Oct 2025
10 Nov 2025
18 Oct 2025
8 Nov 2025
1 Nov 2025
Amount
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings;mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with all accessories complete all as specified as directed by Engineer in Charge comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 300 Amps for phases and 150 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iii) Panel board internal wiring with suitable rated PVC insulated copper conductors. (iv) MCCB 160 Amps,415V, 4 Pole, 25 KA - 01 No (In coming) (v) MCCB 63 Amps, 415V, 4 pole, 16 KA - 04 Nos (Out going)
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with all accessories complete all as specified as directed by Engineer in Charge comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iii) Panel board internal wiring with suitable rated PVC insulated copper conductors. (iv) MCCB 315 Amps,415V, 4 Pole, 35 KA - 01 No (In coming) (v) MCCB 100 Amps, 415V, 4 pole, 25 KA - 06Nos (Out going)
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings;mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with all accessories complete all as specified as directed by Engineer in Charge comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 250 Amps for phases and 125 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iii) Panel board internal wiring with suitable rated PVC insulated copper conductors. (iv) MCCB 125 Amps,415V, 4 Pole, 25 KA - 01 No (In coming) (v) MCCB 63 Amps, 415V, 4 pole, 25 KA - 03Nos (Out going)
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings;mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with complete all as specified as directed by Engineer in Charge comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iii) Panel board internal wiring with suitable rated PVC insulated copper conductors. (iv) MCCB 250 Amps,415V, 4 Pole, 25 KA - 01 No (In coming) (v) MCCB 100 Amps, 415V, 4 pole, 25 KA - 03Nos (Out going)
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings;mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with complete all as specified as directed by Engineer in Charge comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iii) Panel board internal wiring with suitable rated PVC insulated copper conductors. (iv) MCCB 315 Amps,415V, 4 Pole, 35 KA - 01 No (In coming) (v) MCCB 63 Amps, 415V, 4 pole, 25 KA - 10Nos (Out going)
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings;mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with complete all as specified as directed by Engineer in Charge comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 500 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment.(ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) 400 Amps,415V, 4 Pole, 35 KA - 01 No (In coming) (vi) MCCB 200 Amps, 415V, 4 pole, 35 KA - 2Nos (Out going) (vii) MCCB 100 Amps, 415V, 4 pole, 25 KA - 2Nos (Out going)
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings;mounted on angle iron frame 50x50x6mm and having height not less than 60 cm above foundation of PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board with complete all as specified as directed by Engineer in Charge comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment.(ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) MCCB 250 Amps,415V, 4 Pole, 35 KA - 01 No (In coming) (vi) MCCB 63 Amps, 415V, 4 pole, 25 KA - 8Nos (Out going) Note for sl item no 1 to 7 : Quoted rate inclusive of excavation of existing incomming and outgoing cable upto 5m for taking down and reconnecting LT Cable of any size in LT panel including replaceing of Cable lugs , glands etc complete all as specified and directed by Engineer in charge
Supply and fixing in replacement of Onload changeover switch 400 A 4 pole with encosure ,extended handle complete all as specified as directed by Engineer in Charge
Supply and fixing in replacement of MCCB 100 A 16 KA 415 V 4 Pole Fixed thermal and fixed magnetic setting complete all as specified as directed by Engineer in Charge
Supply and fixing in replacement of MCCB 125 A 16 KA 415 V 4 Pole Fixed thermal and fixed magnetic setting complete all as specified as directed by Engineer in Charge
Supply and fixing in replacement of MCCB 160 A 16 KA 415 V 4 Pole Fixed thermal and fixed magnetic setting complete all as specified as directed by Engineer in Charge
Supply and fixing in replacement of MCCB 200 A 35 KA 415 V 4 Pole Fixed thermal and fixed magnetic setting complete all as specified as directed by Engineer in Charge
Supply and fixing in replacement of MCCB 250 A 35 KA 415 V 4 Pole Fixed thermal and fixed magnetic setting complete all as specified as directed by Engineer in Charge
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified as directed by Engineer in Charge.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified as directed by Engineer in Charge.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified as directed by Engineer in Charge.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified as directed by Engineer in Charge. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying un-reinforced precast concrete cable cover, classLV, Type 1, flat, size 250 mm x 150mm x 40mm complete all as specified as directed by Engineer in Charge
S&F Tubes 80 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified as directed by Engineer in Charge
M & L Hard core, broken to gauge n exc 63 mm complete all as specified as directed by Engineer in Charge
M & L Cement concrete in foundations, filling and mass concrete Type C2 1:2:4 (40mm grade aggregate ) complete all as specified as directed by Engineer in Charge
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core complete all as specified as directed by Engineer in Charge
Material and labour in replacement for provision of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised mild steel strip 32 x 6 mm by means of bolts, nuts, check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation, earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion all as specified as directed by Engineer in Charge. Make Tirumalla or equivalent as approved by GE. Note : (i)Earth result after installation completely should be less than 3 Ohm (ii)Quoted rates shall be deemed to include for earth strip with protection pipe of 7.5 M length. (iii) Black soil to be arranged by the conrteractor for mixing charcol,Crystal salt,Magnesium sulphate & Vegitable oil and also for filling balance portion of pit in layer is deemed to be included in quoted rate (iv) Tools and plants to be required for making depth upto 4 Mtr is to be arranged by the contractor,charges for the same is included in the quoted rate
rajengineers (BID ID -3468408)
jagdish machinery stores (BID ID -3470355)
M/s SK Traders (BID ID -3470180)
MADHAV ENTERPRISE (BID ID -3475040)
Sukhi Electricals (BID ID -3470055)
fakhrie apostrical (BID ID -3474936)
MONA GENERATOR SEVICES PVT. LTD. (BID ID -3469930)
S t modi (BID ID -3474009)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
PS.pdf
Tender Documents • 0.90 MB
BOQ_824189.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .