Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC | ₹45.0 L | L1 | Accepted-AOC Accepted - AOC |
| 2 | L2₹46.3 L+₹1.3 L (2.90%)Rejected-AOC H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹46.3 L+₹1.3 L (2.90%) | L2 | Rejected-AOC Rejected - AOC |
| 3 | L3₹47.2 L+₹2.2 L (4.96%)Rejected-AOC | ₹47.2 L+₹2.2 L (4.96%) | L3 | Rejected-AOC Rejected - AOC |
| 4 | L4₹48.9 L+₹3.9 L (8.73%)Rejected-AOC NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | ₹48.9 L+₹3.9 L (8.73%) | L4 | Rejected-AOC Rejected - AOC |
| 5 | L5₹49.6 L+₹4.6 L (10.2%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹49.6 L+₹4.6 L (10.2%) | L5 | Rejected-AOC Rejected - AOC |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
3 Jun 2020, 6:00 pmClosed
GE DEHRADUN
GE DEHRADUN, MALL ROAD, GARHI CANTT
Repair to lekage/ seepage, joinery, flooring, water tubing, sanitary fitting, plastering, painting, approach path, drain and internal electrification of (Region-2) Anarwala under AGE B/R-I of GE Dehradun
2020_MES_342806_1
8205/A/E8
Open Tender
Civil Works
Item Rate
120 days
GE DEHRADUN
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹99,000
Yes
9 Sept 2020
5 May 2020
5 Jun 2020
5 May 2020
3 Jun 2020
20 May 2020
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L brick work with sub class 'B' brick, oled size, straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified.
All as per Item No. 2.00 here in above but except brick complete. Note : Old serviceable brick obtained from demolition shall be reused. The rate quoted against this item is inclusive of necessary cleaning and stacking of bricks before incorporation in the work.
Taking down cement plastering of any description on brick/stone/concrete wall surfaces of any description incl racking out joints hacking for key,scrubbing down with water etc. complete all as specified and as directed.
M & L 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4, using water proofing compound surface finished even and smooth without using extra cement complete all as specified and as directed. (Note : Rendering will be done in two layer. 1st layer will be 10-12 mm thick and 2nd layer will be 3-5 mm thick. Water proofing compound will be measured and paid separately)
M & L 15 mm thick rendering in cement mortar 1:6 on brick work or concrete surface, finished even and smooth without using extra cement complete all as specified and as directed. (Note : Rendering will be done in two layer. 1st layer will be 10-12 mm thick and 2nd layer will be 3-5 mm thick.)
M & L rendering 15mm thick in patches n exc 3 Sqm in cement mortar 1:4 mixed with water proofing compound on fair faces of brick/concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and as directed.
M & L rendering 10mm thick in patches n exc 3 Sqm in cement mortar 1:3 mixed with water proofing compound on finished fair faces of concrete surfaces, chajja/ facia finished even and smooth without using extra cement complete all as specified and as directed..
Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds, chajjas and similar work exc 15 cm but n exc 30 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc.
M & L 10 mm thick rendering in cement mortar 1:3 on concrete surfaces as in ceiling, surface finished even and smooth complete all as specified and as directed.
M & L preparing new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of wall and applying interior grade wall care putty 2 to 3mm thick to make the surface smooth as specified and directed by Engr-in-Charge. Make : Berger/Asian/JK/Birla.
M&L for preparation of wall and applying exterior grade wall care putty 2 to 3mm thick to make the surface smooth as specified and directed by Engr-in-Charge. Make : Berger/Asian/JK/Birla.
M&L for preparation of old decorated surfaces of walls (plastered) by brooming down with coir wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and finally clean with sand paper all as directed by Engr-in-Charge.
M&L for complete removal of existing treatment from wall upto plaster surface by electric sand paper grinder, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper all as directed by Engr-in-charge.
M&L preparation of old decorated surfaces of ceiling (Plastered) by brooming down or sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed.
M&L one coat of white wash on already prepared surfaces of ceiling complete all as specified and directed by Egnr-in-Charge.
M&L one coat of white wash on already prepared surfaces of walls complete all as specified and directed by Egnr-in-Charge.
M&L one coat of oil bound distemper on already prepared surfaces of walls complete all as specified and directed by Engr-in-Charge
M&L one coat of cement base paint on already prepared surfaces of walls on external wall surfaces complete all as specified and directed by Egnr-in-Charge. (Work should be carried out upto triple story bldgs)
M&L two coats oil bound distemper over a coat of primer on undecorated plastered / putty / POP surfaces on walls complete all as specified and directed by Engr-in-Charge.
M&L two coats of cement base paint over a coat of primer on undecorated plastered / putty / POP surfaces on walls complete all as specified and directed by Engr-in-Charge. (Work should be carried out upto triple story bldgs)
M & L preparation of old painted surfaces of wood & wood based material of any description over 10 cm width or girth and applying one coat of PU Paint completeall as specified and as directed.
M & L preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as speciied and directed.
Cutting around the pipe 75/100mm bore waste pipe/soil pipe including taking out plant roots up to any depth in brick masonary and rejointing in pipe joint in epoxy mortar (Asian/Berger) and making good to existing surface all as directed by Engr-in-charge. (After the jointing pipe one week to be open for checking of leaking including scaffolding)
Removing / cutting trees vegetation, digging out roots from concrete or brick wall, filling holes on building (Block of 6 qtrs) wall / roof / chajja etc applying and making good with epoxy mortar (Asian/Berger) and applying surface treatment to match with existing specifications complete.
M&L non skid / mat finish ceramic colour tiles of size 300 mm x 300 mm and 6- 7 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 and including dismantling of existing floor tiling and cement mortar bedding (but not backing) and rubbish off the premises complete.
M&L non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm x6- 7 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 and including dismantling of existing tiling and cement mortar bedding (but not backing) and rubbish off the premisescomplete.
M&L non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm x6- 7 mm thick in skirting, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and including dismantling of existing tiling and cement mortar bedding (but not backing) and rubbish off the premisescomplete.
M&L glazed ceramic colour tiles size 375 mm x 250 mm x 6-7 mm thick or 450mm X 350mmX 7mm on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and including dismantling of existing wall tiling and cement mortar bedding (but not backing) and rubbish off the premises complete.
M & L PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate 25 mm thick as in leveling course to floors complete.
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching to drain, holdfast, padding to roof/chhajja, coping, bed block etc. and the like edge slightly rounded or chamfered including necessary use and waste of form work and including demolition of existing old cement concrete (un-reinforced) not exc 15 cm thick in ground floor and paving below or above ground level complete.
M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement and including demolition of existing old cement concrete plinth protection in ground floor and paving below or above ground level complete.
M & L PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling, mass concrete, sub base or leveling course of floor etc. including demolition of existing old cement concrete (un-reinforced) not exc 15 cm thick in ground floor and paving below or above ground level complete.
M&L 18 to 20 mm thick machine cut polished granite 1st quality "black" stone slab over kitchen platform and similar places over and including 15mm thick screed bed in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match with existing surface including grinding and moulding of exposed edges of granite including demolition of existing stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and as directed.
M & L for coloured prepolished rubber moulded chequred cement concrete tile 30 cm x 30 cm x 20 to 22 mm thick with 3 mm PVC spacer bar, set, jointed and pointed in neat cement slurry as in floor with grey cement and filling joints with colour pigment over and including 20 mm thick screed bed in cement mortar 1:6 including dismantling of old tiles complete.
Taking down and re-fixing the existing shutter in same opening after & including necessary easing/repair etc. exc. 1 Sqm but n. exc. 2 Sqm each complete.
Taking down shutter of any description exc. 1 Sqm but n. exc. 2 Sqm each complete.
Taking down chowkhats or frames with shutter n. exc 1.5 sqm each without taking off shutter from the frame complete.
Taking down chowkhats or frames with shutter exc. 1.5 Sqm but not exceeding 4 Sqm each without taking off shutter from the frame complete.
S & F 35mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) and as directed.
S&F Factory made solid Fibre reinforcement plastic (FRP) frame of size 90mmx63mm the rasin of chemical used in door of unsaturated polyester rasin catagory, cataylst used of methyl Ethyl Ketone peroxide (MEKP)/benzyl peroxide/acetyl aceto peroxide. Accelerator used of cobalt napthalate/cobalt octonate/N.N Dinethyl aniline. Timber suitable for manufacturing of FRP products is in accordance with IS 12896. The timber used for frames is seasoned upto the permissible moisture content as per IS-287 : 1993. Pigment compatible with unsaturated polyester resin is used to obtain the shade of finish complete all as specified and directed by the Engineer-in-Charge.
S&F Factory made solid panel Fibre reinforcement plastic (FRP) door shutter 30mm thick consisting of frame top & bottom rails as per SSR Part I, any number of panels, the rasin of chemical used in door of unsaturated polyester rasin catagory, cataylst used of methyl Ethyl Ketone peroxide (MEKP)/benzyl peroxide/acetyl aceto peroxide. Accelerator used of cobalt napthalate/cobalt octonate/N.N Dinethyl aniline. Timber suitable for manufacturing of FRP products is in accordance with IS 12896. The timber used for frames is seasoned upto the permissible moisture content as per IS-287 : 1993. Pigment compatible with unsaturated polyester resin is used to obtain the shade of finish complete all as specified and directed by the Engineer-in-Charge.
S&F Factory made solid Fibre reinforcement plastic (FRP) frame of size 75mmx50mm the rasin of chemical used in door of unsaturated polyester rasin catagory, cataylst used of methyl Ethyl Ketone peroxide (MEKP)/benzyl peroxide/acetyl aceto peroxide. Accelerator used of cobalt napthalate/cobalt octonate/N.N Dinethyl aniline. Timber suitable for manufacturing of FRP products is in accordance with IS 12896. The timber used for frames is seasoned upto the permissible moisture content as per IS-287 : 1993. Pigment compatible with unsaturated polyester resin is used to obtain the shade of finish complete all as specified and directed by the Engineer-in-Charge.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete.
M&L Rolled sections as in framing or cladding, glazing, door chowkat and the like fixed with angle cleats and connecting plates, etc and including dismantling old section either hooks and hinges or steel hanging door complete
Taking down existing projected type hings from the steel window carefully with out disturbing frame and S& fix 50 mm long mild steel box type hinge weld to steel frame and shutter with welding and making good including touch with paint and with existing surfaces including scaffolding all as directed by Engr-in-charge.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
S&F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples including wooden beading complete all as specified and as directed.
S&F in repair 4 mm thick sheet glass ordinary quality and glazing with silicon and oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane upto triple story of Bldg complete.
All as per item No 50.00 here in above but except glass complete all as specified and directed.
S&F in repair 18 mm thick FRP white board of one side prelaminated and other side plain white colour for cubboard shutter and frame complete as per specifications and as directed by the engineer - in - charge.Make:-Rajshree, Polyline, ECHON/Kumar Tech
S&F in repair 18 mm thick FRP white board to make shelves and partitions for cup boards complete as per specifications and as directed by the Engineer-in- charge. Make:-Rajshree, Polyline, ECHON/Kumar Tech
S&F Continious (Piano) hinges, mild steel, bright finish or electrogalvanised. 30 mm width of flaps (when open) complete all as specified as directed.
S&F Hasp and staple 100mm safety type, stainless steel 202 grade with hinge pin including bolt to hinge plate and fixed with screws
S&F 100 mm size stainless steel butt hinges and fixed with stainless steel screws, complete all as specified and directed by Engr-in-Charge.
S&F 200 mm long, solid in one piece stainless steel 202 grade bright finish barrel tower bolts 10mm dia shoot complete all as specified and directed by Engr-in-charge.
S&F 150 mm long, solid in one piece stainless steel 202 grade bright finish barrel tower bolts 10mm dia shoot complete all as specified and directed by Engr-in-charge.
S&F 150mm size solid in one piece stainless steel 202 grade bright finish handles, D type and fixed with stainless steel screws complete all as specified and directed by Engr-in-Charge.
S&F 125mm size solid in one piece stainless steel 202 grade bright finish handles, D type and fixed with stainless steel screws complete all as specified and directed by Engr-in-Charge.
S&F magnet catcher for cub board with brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F stainless steel sliding door bolts 204 grade, hasp and staple type with bright bolt not less than 16mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 250mm long
Taking up or down PPR water tubing and connections with all fittings for 15 mm bore tubing complete.
Taking up or down PPR water tubing and connections with all fittings for 20 mm bore tubing complete.
M&L cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10cm girth.
S&F 15mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed by Engr-in-Charge.
S&F 20mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed by Engr-in-Charge.
Supply and fixing PVC connection 15 mm dia 450 mm long with bras fly nut at both ends complete.
S&F in repair viterous china squatting pan (orissa pattern) long pan size 580x440mm white with integral footrest jointed with trap with epoxy mortar (Asian/Berger), set in cement concrete type B-1 (1:2:4) complete (excluding Trap, flushing cistern and flush pipe) complete all as specified and directed by Engr-in-charge
S&F in repair spun cast iron 600 mm long 'P' trap fixed with epoxy mortar (Asian/Berger), set in cement concrete type B-1 (1:2:4) complete complete all as specified and directed by Engr-in-charge
S & F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including bracket with 32 mm dia PVC pipe/bend 600 mm long complete. Hindware/Parryware/Jaquar.
S&F in repairs 550x400mm wash basin, vitreous china (Flat back) including fixing and pinning in ends of brackets including pop up CP brass waste coupling or requisite size and PVC waste pipe. Make : Cera/Jaquare/Parryware
S & F in repair 75 mm bore UPVC (SWR) pipe 4 kgf/cm2 single socketed in any length with rubber ring, fixed on wall complete all as specified. Make : Supreme/Finolex
S & F in repair 110 mm bore UPVC (SWR) pipe 4 kgf/cm2 single socketed in any length with rubber ring, fixed on wall complete all as specified. Make : Supreme/Finolex
S & F in repair 75 mm bore UPVC (SWR) pipe 4 kgf/cm2 single socketed in any length with rubber ring,joints laid in trenches complete Make : Supreme/Finolex
S & F in repair 110 mm bore UPVC (SWR) pipe 4 kgf/cm2 single socketed in any length with rubber ring,joints laid in trenches complete Make : Supreme/Finolex
S & F in repair UPVC (SWR) bend, 75 mm bore' complete all as specified. : Supreme/Finolex
S & F in repair UPVC (SWR) junction single, (Single T) equal or unequalnd, 75 mm bore with access door complete all as specified. : Supreme/Finolex
S & F in repair UPVC (SWR) bend, 110 mm bore' complete all as specified. : Supreme/Finolex
S & F in repair UPVC (SWR) junction single, (Single T) equal or unequalnd, 110 mm bore with access door complete all as specified. : Supreme/Finolex
S & F in repair UPVC (SWR) cowl, 75 mm bore' complete all as specified. : Supreme/Finolex
S & F in repair UPVC (SWR) cowl, 110 mm bore' complete all as specified. : Supreme/Finolex
S&F in repairs PVC tank lid/cover threaded with frame fixed with the existing water storage tank (cylindrical) for 500/1000 ltrs capacity tanks, complete all as specified and directed by Engr-in-charge
S&F in repair pillar taps, brass, chromium plated, with capston heads, fancy type screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed. Make : JAQUAR/Cat part No. KUP-35001PM/Hindware Cat Part No:F370001/Parryware Cat Pat No.T4302A2
S&F in repair brass chromium plated ovehead shower with shower arm complete all as specified and directed. Make : - Parryware Cat Part No T9985A1(Shower) & T-9999A1(Arm)/Hindware Cat Part No F160054 (Shower) & F190016(Arm)/Jaquar Cat Part No OHS 1999 (Shower) & SHA479L300 (Arm).
S & F in repair 15 mm dia bore brass chromium plated concealed stop cock, complete. Make :Jaquar/Hindware/Parryware
S&F in repair 15 mm bore Angle/ stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed. Make : - JAQUAR Cat Part No FON-40053/Hindware Cat Part No F160017/Parryware
S&F in repair 15mm bore Bib taps short body, cast copper alloy fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. Make : - JAQUAR CAT Part No ALI-85037/Hindweare CAT Part No F-370004/Parryware
Taking down and re-fixing only of bib cock/ stop cock/ angle cock/ gate valve/ shower/ concealed stop cock etc complete all as specified and directed.
Cleaning of existing PVC/RCC water storage tank with vaccum cleaner machine exc 250 to 500 ltrs capacity with D scaler (Taski) and dry with and apply on coat of anti bacterial spray (R1 Taski) as directed by Engr-in-charge. Date of cleaning to and CA No to be painted on water storage tank with stencil in black/ white synthetic enamel paint all as directed by Engr-in-Charge.
S & F rotational moulded polyethylene water storage tanks 500 Ltr triple layer white, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site, complete.
S & F rotational moulded polyethylene water storage tanks 1000 ltr triple layer white, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site, complete.
S&F in repairs 75mm dia centrifugally cast (spun) iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B 1(1:2:4)
S & F in repair 20 mm bore gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete.
S & F in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 20 mm bore size (Minimum weight 210 gms) complete.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for 60 mm thick pre polished rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment complete all as specified and as directed by the Engr-in-Charge in replacement.
Providing & fixing false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of
All as per item No 99.00 (Contd/---) …. 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, including taking down existing ceiling all complete at all heights as per direction of Engineer-in-Charge.
S&F Aluminium (Die Cast body) Door closer hydraulically regulated designation No 1 universal type suitable for door shutters up to 851 mm to 1000mm in width and of weight between 61 to 80 kg and fixed complete all as specified & directed.
Taking out existing roof treatment and M&L for water proofing treatment on roof slab including picking, sweeping clean and washing down with water to remove dust & providing water proofing treatment described as under:- (a) Surface preparation with Asian smart care mortar and GP groute mortar and treating of construction joints, filling of honey combs with polymer modified mortar (Cement: Sand : smart care multipurpose polymer of Asian Paints or equivalent product of Thermax/ Berger ) (b) Cleaning the surface and applying (Resin & Hardner) smart care Epoxy Primer 2k of Make Asian paints or equivalent product of Thermax/ Berger ) on the cleaned surface for bonding of PU magnum with the existing concrete surface.
All as per item No 101.00 (Contd/--)… (c) Supplying, providing and applying waterproofing treatment to Terrace area with Asian Paints Smart care PU magnum, single component highly elastomeric seamless cold applied modified PU coating or equivalent product of Thermax/ Berger) including all necessary surface preparation, coving using smart care multipurpose polymer, water pond test, etc. complete as per manufacture's specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1mm. The coating shall have dual combination of 250% elongation . Execution to be done with authorised applicator of the manufacturer and company back gurantee to be given by the contractor. Work will be executed in smart assurance system
Cleaning of manholes not exceeding 1.5m depth and removing the sludge and burying the waste material in borrow pits. Note:-(cost of the borrowpit shall be deemed to be included in the quoted rates of this item).
M&L for dewatering and desludging of septic septic tank/sokage well of any size and depth by manually/mechanically (solid contents if not removed by mechanically should be removed by manually) and removing the sludge out side of MOD complete all as directed at site. After complete cleaning of septic tank the manhole cover shall be re-fixed in same position with CM 1:4 and bleaching powder spread on top surface of septic tank @ 1 Kg per septic tank complete all as specified and directed at site.
Pumping out sewage water from the man holes /Septic taank/soakage well at different locations by means of sewage tanker fitted with pump (5000 Ltr capacity) and disposing out off MD land as directed by Engineer-in-charge.
Excavation in trenches in any type of soil not exceeding 1.5M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete.
Demolition and breaking drain pipe 150mm (salt glazed stoneware) set in cement mortar complete all as specified.
Supplying, laying, jointing and testing salt glazed stone ware drain pipe 150mm internal dia of length 75 cm grade ‘A’ confirming to IS–651–1980 laid in trenches and jointed in cement mortar 1:1 including cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate complete for the following dia :-
Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete.
Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete.
M&L for 60 mm thick vibromatic reinforced precast cement concrete 1:1:2 (using 20mm graded stone aggregate) with 2mm thick mild steel CR sheet around painted with 2 coats of bituminous paint , as in man hole cover slabs finish fair even and smooth without using extra cement ( Top surface will be chequred finish) including necessary form work, 100 mm long handle of 12mm dia round bar counter sunk by 25mm welded to reinforcement complete all as specified and directed by Engr-in-charge in replacement.(Note : CA No and date will be engraved on covers. Reinforcement shall be measured and paid separately. Curing will carried out with ponding method)
M & L 15 mm thick rendering on brick work or concrete surface of manhole, septic tank in cement mortar 1:4 surface finished even and smooth with out using extra cement complete.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, lamp holders, regulators, sockets, light fitting any type etc complete. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engr-in-charge
M&L for Point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area), PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through and including non metallic medium duty rigid PVC concealed conduit (medium duty) 20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed steel juction box of thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly complete all as specified and directed by Engr-in-charge for the following.
(a) One light / exhaust fan point controlled by one-one way switch.
(b) One ceiling fan point controlled by one-one way switch through regulator.
(c) One bell Point controlled by bell push switch
(d) One three pin 5 Amp socket on same board with other switches.
(e) One three pin 5 Amp socket on independent board.
(f) One light point controlled by two -2 way switches
All as per item No.113.00 here in above but with 2.5 Sqmm. (nominal area) wire/cable for phase and neutral for one 3 Pin 15 amp socket on independent board including one 2.5 sqmm PVC insulated unsheathed multi stranded copper conductor cable, FRLS 1100 volts grade as earth continuity conductor upto common earth & connected to earth dolly complete all as specified and directed by Eng.-in-charge.
M&L for point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through existing steel/PVC conduit etc and existing terminal boxes but with new 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly complete all as specified and directed by Engr.-in-charge of following.
(a) One light / exhaust fan point controlled by one-one way switch.
(b) One ceiling fan point controlled by one-one way switch through regulator.
(d) One three pin 5 Amp socket on same board with other switches.
(e) One three pin 5 Amp socket on independent board.
(c) One bell point controlled by bell push switch
(f) One light point controlled by two -2 way switches
All as per Item No 115.00 here in above but one three pin 15 Amps switch socket out let on the independent board with 2.5 sq mm PVC insulated FRLS copper conductor and 2.5 Sqmm FRLS copper conductor for continuous earthing complete.
S&F switch piano one way flush type 5 Amp SP 250 Volt AC complete all as specified & directed.
S&F switch piano two way flush type 5 Amp SP 250 Volt AC complete all as specified & directed.
S&F switch piano one way flush type 15 Amp SP 250 Volt AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet 2-in1,3 pin 5 and 15 Amp flush type 250V AC complete all as specified & directed.
S&F Bell push flush, flush type 5 Amp SP 250 Volt AC complete all as specified & directed.
S&F Bell Ding dong 250V AC complete all as specified & directed.
S&F ceiling rose surface bakelite 3 terminals of size 65x25mm. complete .
S&F step type, electronic fan regulator 120 watts, 5 step for ceiling fan 1200/1400 mm sweep 230 volts AC.
S&F lamp holder PVC/polycarbonate type with LED lamp 7 watt retrofit complete all as specified & directed.
S&F lamp holder PVC/polycarbonate type with LED lamp 10/14 watt retrofit complete all as specified & directed.
S&F lamp holder PVC/polycarbonate type with LED lamp 3/5 watt retrofit complete all as specified & directed.
S&F in repairs switch piano one way flush type 5 Amp SP 250 Volt AC complete all as specified & directed.
S&F in repairs switch piano two way flush type 5 Amp SP 250 Volt AC complete all as specified & directed.
S&F in repairs switch piano one way flush type 15 Amp SP 250 Volt AC complete all as specified & directed.
S&F in repairs socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F in repairs socket outlet 2 in1,3 pin 5 and 15 Amp flush type 250V AC complete all as specified & directed.
S&F in repairs Bell push flush, flush type 5 Amp SP 250 Volt AC complete all as specified & directed.
S&F in repairs Bell Ding dong 250V AC complete all as specified & directed.
S&F in repairs ceiling rose surface bakelite 3 terminals of size 65x25mm. complete .
S&F in repairs step type, electronic fan regulator 120 watts, 5 step for ceiling fan 1200/1400 mm sweep 230 volts AC.
S&F in repairs lamp holder PVC/polycarbonate body complete all as specified & directed.
S&F in replacement mirror light decorative compact luminarious with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size . Make Havells Cat No E-Lite Pride LHEXBLP7IN1W009 or eqvt in Philips/Wipro
S&F in replacement wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 4000K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make:Wipro Cat part No LL20-281-XXX-65AL1/ Philips cat part No BN021C LED20S PSU CWGR S2/Havells Cat No ENDURA LINEARNEOBS20W LED840SPCWH.
Supply and fixing in replacement LED tube rod 18/20 Watts single or double sided connections polycarbonate complete incl making connection alteration in existing tube light fitting complete all as specified and directed. Make: Philips / Bajaj/ Havells.
S&F in replacement energy saving Bulk head luminaire with opal diffuser with and including retrofit LED lamp 10 watts complete all as specified and directed by Engr-in-charge. Make : CG part No LBHP-10-CDL/ Philips WT 140W LED 7S CW PSU S1PC/ /Havells ENDURA RUGBYNEO N / MEPRO BCL 23 PLAIN
S&F in repairs TPN DB VTPN 4 way 415 Volts, 50 Hz indoor type double door sheet metal enclosure IP-43 protection flush mounted with copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable managenment including mounting arrangement for 100/125 Amps four pole 415 volts MCCB as incomer and MCBs as outgoing complete pre wired with suitable size copper conductor incl taking out unserviceable DBs, MCCB and MCBs of any capacity complete all as specified and directed by Engr-in-charge. The DB's should hold type test certificate (CPRI) as per IEC 61439-3 Make: Legrand/L&T/ Indo Asian/C&S.
S&F in repairs distribution board SPN 8 way 240 volt with suitable rated bus bar double door IP-43 DB's mounting flush on wall/concealed and making good distubed surfaces incl taking out unserviceable DB any capacity complete all as specified and directed by Engr-in-charge. Make: Legrand/ L&T/ Indo Asian..
S&F in repairs distribution board SPN 2 way 240 volt with suitable rated bus bar single door IP-43 DB's mounting flush on wall/concealed and making good distubed surfaces incl taking out unserviceable DB any capacity complete all as specified and directed by Engr-in-charge. Make: Legrand/ L&T/ IC&S.
S&F in replacement Sheet metal enclosure SPN with a two pin and earth plug and socket complete with one 20 amp single pole 10 KA C series MCB complete all as specrified & directed
S&F in replacement of MCCB 100 Amps four pole 415 volts thermal magnetic release ICU=100% ICS having breaking capacity 16 KA including connection terminal strip complete all as specified & directed Make:Legrand/ L&T/ C&S
S&F MCB single pole 240 volt, 10 KA, 6 to 32 Amp, 'B' series confirming to IS complete all as specified and directed. Make: Legrand/L&T/Hager/C&S.
S&F MCB SPN 240 Volt 10 KA 6 to 32 Amp 'B' series conforming to IS complete all as specified & directed. Make: Legrand/L&T/Hager/C&S...
S&F MCB SP 240 Volt 10 KA 40 Amp 'B' series conforming to IS complete all as specified & directed. Make:Legrand/L&T/Hager/C&S.
M&L for replacement of Unserviceable Earthing complete with copper electrode chemical advance maintinence free chemical gel earthing electrode 50 mm dia pipe burried directly in ground vertically to a depth not less than 2.10 mtr below ground level filled with highely conductive metalic compound mixture CCM with the permanent sealing of the both end, outer dia pipe 50 mm with strip terminal 50x6 mm with terminal holes incl one bag 25 kg of BFC compound, earth connected with earth lead GI wire 4.00 mm. dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe medium 15 mm. bore,
All as per item No 151.00 Contd/-- and water pipe 20 mm. bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & 75 mm thick RCC (1:2:4) type B1 cover slab reinforced with 8mm TMT bars 100mm c/c both ways complete all as specified & shown in elect plate No. 3 of SSR part I of 2009 and testing on completion. Note: (i) If the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 sqmm and 15 mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item . (iii) Earthing should be done by CPRI approved firm.
M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sqmm (nominal area) drawing in and including 20 mm dia or higher medium duty PVC concealed conduit and conduit accessories and fittings. Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 6 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed.
All as per item No 152.00 here in above but drawing through existing concealed conduit incl taking out old unserviceable submain all as specified & directed.
S&F in repairs laminated sheet 3mm thick of size 125x100mm including cutting slots for fixing switches etc all as directed
S&F in repairs laminated sheet 3mm thick of size 200x125mm including cutting slots for fixing switches etc all as directed
S&F in repairs laminated sheet 3mm thick of size 200x250mm including cutting slots for fixing switches etc all as directed
S&F in repairs laminated sheet 3mm thick of size 100x100mm including cutting slots for fixing switches etc all as directed
S&F in repairs pressed steel terminal sunken box 1.2mm thick of size 125x100mm for mounting of sheet cover incl cutting chases, plastering, making good disturbed surfaces of wall, painting as per existing to match the wall complete all as directed.
S&F in repairs pressed steel terminal sunken box 1.2mm thick of size 200x125mm for mounting of sheet cover incl cutting chases, plastering, making good disturbed surfaces of wall, painting as per existing to match the wall complete all as directed.
S&F in repairs pressed steel terminal sunken box 1.2mm thick of size 200x250mm for mounting of sheet cover incl cutting chases, plastering, making good disturbed surfaces of wall, painting as per existing to match the wall complete all as directed.
S&F in repairs pressed steel terminal sunken box 1.2mm thick of size 100x100mm for mounting of sheet cover incl cutting chases, plastering, making good disturbed surfaces of wall, painting as per existing to match the wall complete all as directed.
Supply and laying in repairs XLPE insulated, armoured, heavy duty electric cable, with multi stranded aluminum conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and overall PVC sheathed 1100 Volts grade, nominal cross sectional area 25 Sqmm 3.5 core incl lugs thimbles bottle timbles and gun metal cable glands and heat shrinkable PVC sleeves on exposed surfaces and teflon tape duly insulated complete laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/ floors/ equipment etc including taking out existing cable complete all as specified and directed by the Engr-in-Charge. Make : Havells/Polycab/KEI/Grandlay
Supply and laying in repairs XLPE insulated, armoured, heavy duty electric cable, with multi stranded aluminum conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and overall PVC sheathed 1100 Volts grade, nominal cross sectional area 10 Sqmm 2 core incl lugs thimbles bottle timbles and gun metal cable glands and heat shrinkable PVC sleeves on exposed surfaces and teflon tape duly insulated complete laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/ floors/ equipment etc including taking out existing cable complete all as specified and directed by the Engr-in-Charge. Make : Havells/Polycab/KEI/Grandlay
M&L for sand cushioning in trenches for protection of UG cable with river bed sand laid dry in trenches before and after laying of cable, including well ramming and consolidation complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Supply and laying in replacement of GI Steel tubing light grade 50 mm dia including all fitting laying in trenches or grouting/fixing in wall for protection of cable complete all as specified and directed by Engineer-in-charge
S&F in replacement tamper proof electronic single phase whole currrent energy meter (LCD display) 10 Amp to 60 Amp, 240 volt class 1.00 and AC supply including cable connection, proper sealing with barcode with PVC seal. The meter shall comply with the latest version of IS-13779 with at least 2 anti tamper LED indications of line load reversal and earth loading indication including electrical connection with existing system and sealing properly including push fit type transparent meter box . The meter shall work satisfactory with guaranteed accuracy as per limit of IS: 13779. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. Make:- Secure /L&T/BHEL (Note:- Old unserviceable meter will be deposited to E/M store yard)
S&F in replacement Meter Distribution Board made out of Thermoplastic polycarbonate of size 600x600x170 mm (dust proof & weather proof ,shock proof, rust proof ,corrosion free , acid & chemical resistance ,UV resistance , halogen free & recyclable material) wiyh 230v Ac 50 HZ 3 Wire, suitable for mounting of electronic Meter -04 Nos incuding electrical connection with exsisting system and sealing properly & taking out u/s broken/rusted box of any size and type complete all as specified and directed. Make Hensel cat part no Mi0800 / Secure/Sintex
S&F in replacement Bldg Security light fitting comprising of pressure die cast aluminium housing heat resistant toughened glass IP-65, photovoltic LDR sensor with separate surge protection 5KA, 35 Watts or near higher size fixed on and including GI pipe bracket made of 40 mm bore medium grade pipe 1.2m long made to shape, MS clamps of size 32 x 3 mm flat iron, nuts, bolts and washers of required size and painting complete with all necessary electric connection etc all as specified and directed. Make: Greenstar Cat No: DSS3 or equivalent in Philips / Crompton.
Taking down existing electric metre and refixing in new position with all nut bolts screws etc connecting up completely including necessary copper wires of suitable size complete all as directed.
M/s Pradeep Kumar
M/S C S AITHANI
SRI GANESH ENTERPRISES
M/s Anil Kumar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .