Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.2 L+₹2.1 L (8.71%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹27.9 L+₹3.8 L (15.8%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹31.3 L
EMD Value
₹50,000
Closing Date
11 Nov 2024, 3:00 pmClosed
EXECUTIVE ENGINEER
O/o of EXECUTIVE ENGINEER, P.H.DIVISION,KOCHI-16
AMRUT-1.0-Supplying, laying testing and commissioning of 160mm PVC pipe ( 10kg/cm2 ) from Fort Kochi OHSR to Thuruthy near to RAY Flat for providing water connection to proposed multi storied housing complex at Thuruthy (RAY Flat) Fort Kochi in Dn.2
2024_KWA_701559_1
WRD/KWA-CE(CR)/TR/11316/2024
Open Tender
Civil Works - Water Works
Item Rate
30 days
THURUTHY
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,760
₹50,000
18 Jan 2025
2 Nov 2024
12 Nov 2024
2 Nov 2024
11 Nov 2024
2 Nov 2024
2 Nov 2024 - 11 Nov 2024
Amount
Working charges
100.98.239:Supply of PVC Pipe, 10kg/cm2, 160mm Dia.
OD133327/2024-2025:Supply of 300mm CID Joint
OD133328/2024-2025:Supply of 150mm CID Joint
100.98.496:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 150mm.
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.2:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
2.16.1:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m
2.16.2:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 1.5 m but not exceeding 3 m
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
100.31.2.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class II.
OD85146/2024-2025:Fabricating 300x300x150 mm Lateral tee for tapping the existing 300mm AC/CI from the proposed 160mm PVC pipe pipe including cost of cutting , welding, grinding and fabrication of the tee and cost of flanges , labour etc, complete
100.98.1001:Engaging Bhisti.
100.98.1008:Engaging Coolie.
OD89181/2024-2025:Fabricating 150mm M S Dummy flanges of diameter 150mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
OD37934/2024-2025:Interconnecting the newly laid 160mm PVC pipe with the existing 300mm AC/CI pipe at Fort Kochi OHSR site including cost of all labour charges,earth work excavation in all classes of soil for exposing the main pipe, by using 160mm PVC Coupling etc already fabricated 300x150mm MS tee, 300mm CID Joint,150mm CID Joint, etc ,excluding cost of materials , etc complete as per the direction of deptl. officers
OD32834/2024-2025:Providing 50mm (2 inch) house connection with 50mm (2 inch )Water Meter from Proposed 150mm DI Pipe line using 150x50mm MS saddle clamp and 63mm PVC threaded adapter,meter chamber,50mm GM valve etc. supplied by the contractor and placing in position,jointing and testing to the required test pressure, including cost of saddle clamp, adapter,labour charges ,hire for tools, and including the charges of 50mm water meter etc.complete.
15.60:Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
16.78.2:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Construction of Valve Chamber and Anchoring works
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
100.41.34:Supplying and fixing Rectangular C.I. manhole cover 455mm x 610mm with frame (low duty) charges including all cost, labour charges etc., complete.
SUBASH N C (BID ID -1971787)
sathyan (BID ID -1969413)
Bidder Name
sathyan
AKSHAY KR
SUBASH N C
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1096451.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .