Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹16.4 L+₹1.1 L (7.46%)Rejected-Finance FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
12 Oct 2021, 6:00 pmClosed
GE UTILITY
GE UTILITY AMBALA CANTT 133001
PREVENTIVE MAINTENANCE OF STP INSTALLATION AT ALLENBY LINE IN SECTOR C INCLUDING ALL CONNECTED ITEMS UNDER GE U AMBALA CANTT
2021_MES_474753_1
CA NO GE U AMB 41 OF 2021 22
Open Tender
Civil Works
Item Rate
270 days
GE UTILITY AMBALA CANTT
As per Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE UTILITY AMBALA CANTT
₹30,000
Yes
11 Jan 2022
13 Sept 2021
14 Oct 2021
13 Sept 2021
12 Oct 2021
27 Sept 2021
13 Sept 2021 - 20 Sept 2021
Amount
Taking out Non clog submersible sewage pumping set from equilisation tank at STP (after and including dewatering of well) of 7.5 HP capacity Make- Kirloskar by lifting and dismantling the same for assessing and carrying out the repair/serving and replacement of unserviceable parts with new parts as listed in subsequent items and making good in running condition with balancing, reassembling and lowering the same in well & fixing on the foundation making connections and testing complete all as specified & directed by Engineer-in-Charge. Note:- (a) The replaced parts of pump shall be measured & paid separately here-in-after as supply only. (b) Dewatering of well upto max 500 mtr distance from well shall be included in the quoted rate of this item.
Rewinding of motor 7.5 HP non clog submersible sewage pumping set Make- Kirloskar with suitable size and proper guage of winding wire using best quality of super enamelled copper wire and insulation material including all other connected items complete all as specified & directed by Engineer -in- Charge.
Material and labour in replaceemnt CI impeller with guide bush suitable for 7.5 HP Non clog submersible sewage pumping set complete all as specified & directed by Engineer-in-Charge
All as per item no 3 above but lubricated upper/lower bearing for non clog submersible pump set 7.5 HP complete all as speicified & directed by Engineer-in-Charge.
All as per item no 3 above but pump shaft suitable for non clog submersible pump set 7.5 HP complete all as speicified & directed by Engineer-in-Charge.
Taking out centrifugal induction motor from foundation and transport to work shop for rewinding and taking out burnt winding wire from motor of capacity 20 HP three phase , rewinding with super enamelled copper wire of suitable gauge or as per existing gauge complete including all required insulation material and transport back to site after testing and commisioning complete all as specified and directed by Engineer in charge. Make of wire: Finolex/Plaza/Havells. Note : (a) The Motor testing will be done before installation on No load for any unbalance load and should be free from vibration and if found unsatisfactory no payment will be done to contractor for defected motor. (b) Necessary thimbles, lugs, insulation tape, nut bolts and all items required for installation of motor at site will be included in the rate quoted by the contractor. No extra payment will be done to contractor.
Description all as per srl item No 6 here in before but of capacity 10 HP
Description all as per srl item No 6 here in before but of capacity 5 HP
Description all as per srl item No 6 here in before but of capacity upto 1.5 HP
Supply & topup in replacement suitable compressor oil in air blower of make Everest Model No N5125 at STP complete all as specified and as directed
Supply and fixing in replacement front & rear bearing suitable for 20 HP motor as per existing cat part and make all as specified and direcred. Note: (a) The rate of dismantling and refixing of motor from pump with complete accessories are included of quoted in the same item. (b) The alingnment of shaft should be checked during installation of motor with pump in all respect. The contractor will bear the cost of repair in case of failure of motor occurs due to misalingment and no extra payemnt will be paid to contractor.
Description all as per srl item No 11 here in before but for motor 10 HP of existing/suitable size complete. Make-SKF/NBC.
Description all as per srl item No 11 here in before but for motor 5 HP of existing/suitable size complete. Make-SKF/NBC.
Maintenance and repair to leakage/blockage of water supply MS/CI/DI pipe line of 80 mm to 200 dia including necessary excavation earth work required for taking out burning out lead joint or damaged rubber ring/hole from position and making the disturbed surfaces as per existing surface after replacing new spun yarn and lead joint or Tyton joint or necessary fitting required as per site properly including welding work and making the pipe line leak proof completly to the entire satisfaction of Engineer-in-Charge.
M & L carrying out the Tests of treated water from NABL approved lab every month and maintain the record of treated sewage as per frequency :- (i) PH Valve (ii) TSS (iii) BOD (iv) COD (v) Oil & Grease (vi) FC Min (vii) Nitrate CN Note:- Test report should be submiited at the end of month by contractor .otherwise penalty of Rs. 1000/- will be imposed.
Supply only chemicals PAC (Sodium Hypo chloride) required to achieve desired parameter of treated water and required spares for operation of the plant, at least one month requirement of the materials required shall be kept at site at a time etc complete all as directed by Engineer-in-charge
Supply only chemicals PE (Poly Electrolite) required to achieve desired parameter of treated water and required spares for operation of the plant, at least one month requirement of the materials required shall be kept at site at a time etc complete all as directed by Engineer-in-charge
Cleaning of tanks after desludging from sewage tanks (Raw Sewage Tank-01 No, treated water tank -01 No, Chlorine Contact Tank-01 No ) etc shall be carried out with water and chemical as applicable and complete white wash after cleaning the tanks and dates of cleaning shall be marked on tank etc complete all as directed by Engineer-in-charge. .
S & F in replacement electronic dosing pump of cap 0-5 IPH,pressure 5.5 kg/sq cm including connected items with new ones complete all as specified by Engineer in charge
S & F in replacement sludge feed pump screw type discharge 2 meter cube/ HR and 8 mtr head including connected items with new ones complete all as specified by Engineer in charge
S & F in replacement DWPE Dosing tank of capacity 1000 ltr complete all as specified and directed by Engr-in-charge.
S & F in replacement DWPE Dosing tank of capacity 200 ltr complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement Ductile iron pipe of 200mm bore, S/S,Class K-9 , with rubber gasket(tyton) joints and complete jointig material ,ISI marked including excavation earth work complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Ductile iron pipe of 150mm bore, S/S,Class K-9 , with rubber gasket(tyton) joints and complete jointig material, ISI marked including excavation earth work complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of foot valve 200 mm nominal bore ISI marked complete including dewatering of tanks for replacement , gasket nuts, washers etc complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement stop valve cast copper alloy 25 mm bore screwed down high pressure with crutch or Butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engr-in-Charge.
S&F in replacement Butter Fly sluice Valve lever operated conforming to IS 13095 of size upto 150 mm dia PN 1.6, connected with two end flanges suitable for connecting with Pipe including nut - bolts etc all as specified and directed.
Description all as per item 27 above here in before but 125 mm dia,
Description all as per item 27 above here in before but 100 mm dia,
Description all as per item 27 above here in before but 80 mm dia,
Description all as per item 27 above here in before but 50 mm dia,
Supply and fix in replacement Non Return Valve 150 mm dia PN 1.6, connected with two end flanges suitable for connecting with Pipe including nut - bolts etc all as specified and directed.
Description all as per item 32 above here in before but 125 mm dia,
Description all as per item 32 above here in before but 100 mm dia,
Description all as per item 32 above here in before but 50 mm dia,
S&F in replacement Sluice Valve with spindle and check nut conforming to IS 14846 of size upto 200 mm dia PN 1.0, connected with two end flanges suitable for connecting with Pipe including nut - bolts etc all as specified and directed.
Description all as per item 36 above here in before but 150 mm dia,
Supply and fixing in replacement GI pipe 40 mm bore medium grade ISI marked fixed on wall or laid in floors/trench with all fittings including excavation and earth work complete all as specified and directed by Engr-in-Charge.
All as per srl item No 38 here in before but 25 mm bore.
Supply and fix in replacement PVC insulated aluminium cable round of size 10 Sqmm 3 core complete all as specified & directed by Engineer-in-Charge
Supply and fix in replacement PVC insulated submersible copper cable flat/round of size 6 Sqmm 3 core complete all as specified & directed by Engineer-in-Charge
Supply and fix in replacement PVC insulated copper cable flat/round of size 1.5 Sqmm 4 core complete all as specified & directed by Engineer-in-Charge
Taking down/out unserviceable UG cables any cross sectional area and connections including Bricks, GI Pipes, etc of any descriptions, laid in trenches and/or fixing with walls/poles including segregating of serviceable materials viz Bricks, cables, GI Pipes etc complete all as specefied and as directed.
Supply & Fixing passing through pipe, XLPE insulated, Armoured, Electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade, nominal cross sectional area 10 sqmm 2 core including Brass compression cable gland, terminal lug etc and testing complete including excavation earth work, brick work and sand complete and clamps as per requirement all as specefied and as directed.
All as per item No 44 above, but nominal cross sectional area 16 sqmm 4 Core
All as per item No 44 above, but nominal cross sectional area 70 sqmm 3.5 Core
M & L earthing complete with galvanised steel earth plate electrode 600 x 600 x 3.15 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised GI strip 32x6 mm and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I 2009 connected to earthing test point including all earth work excavation, returning filling and disposal of surplus soil and testing on completion. Complete all as specified and directed
Repair and Servicing of DG set 125 KVA of Mahindra & Mahindra complete in all respect, installed at STP installation including replacement of defective parts (spares parts shall be measured and paid separately under respective items of schedule as supply only) and testing complete all as specified and directed by Engr-in-Charge. Note:- Fixing of parts shall be included in the quoted rate.
Supply only Fuel filter Assy
Supply only Lub filter Assy
Supply only Fuel pre filter assy
Supply only Air cleaner element
Supply only Air cleaner safety element
Supply only V Belt
Supply only Coolant Super Plus , 20 Ltr
Supply only Flex hose for vent
Supply only Fuel pipe return hose
Supply only Hose for engine water out connection
Supply only Hose for engine water in connection
Supply only Hose for balance water pipe
Supply only Engine oil 20W40 castrol
Supply only Suction hose for Engine
M&L cable three core PVC insulated, PVC sheathed multi stranded copper conductor of size 2.5 Sqmm 3 core for connection junction box to security light/bollard light complete all as specified and directed by Engr- in- charge.
Removing old paint from surface of steel LT pole by scraping,rubbing and making good surface for painting and applying one coats of aluminium paint incl writing Pole No as directed and Blue reflector and white reflector in alternate layer up to 0.90 cm from GL all complete as specified and directed.
Taking down worn out and S & F 3 phase with MCB SP 10A suitable for Cable IP 65 Protection with metric knockout for cable entry including MS clamp fixed on pole with clamp nuts,bolts etc all as directed by Engr in charge.
S&F in replacement warm type LED Integral decorative type bollard 9 watt IP 65 protection, class I with operating voltage range 120 to 270 V all as specified and directed by Engr In charge.
M& L in replacement contactor 3 pole of AC3 rating upto 50 Amp or as per existing rating and 220 V/415V coil rating complete with all new wiring including thimbles and lugs,nuts and screws all as specified by Engr-in-charge. Make: BCH/L&T/ABB/Havells
Material and labour in replacement thermal overload relay with range 28-42 Amps 415 V, 50 Hz,complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement single phase preventor suitable for 20 HP motor star- delta starter 415 V, 50 Hz,complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement single phase preventor suitable for 10 HP motor star- delta starter 415 V, 50 Hz,complete all as specified and directed by Engr-in-Charge.
M&L for atending any type pump/motor/LT panels/DGs/Starters complaint at pump houses and boosters and rectify the same, including replcement of thimbles any type and any size with nut-bolts and cable jointing with tap, gland packing, greasing in pumps/valves with all connected items all as specified by the Engr-in-Charge. Note: Complaint should be rectify within 06 Hrs otherwise a penalty of 500 Rs per day will be imposed.
M&L in replacement MCCB 4P, 35 KA breaking capacity, 320 Amp, 50 Hz adjustable thermal and magnectic type with thimbles and nut-bolts complete all as specified and directed.
M&L in replacement MCCB 4P , 35 KA breaking capacity, 200 Amp, 50 Hz adjustable thermal and magnectic type with thimbles and nut-bolts complete all as specified and directed.
M&L in replacement MCCB 4P , 16 KA breaking capacity, 100 Amp, 50 Hz adjustable thermal and magnectic type with thimbles and nut-bolts complete all as specified and directed.
M&L in replacement MCCB 4P , 36 KA breaking capacity, 630 Amp, 50 Hz adjustable thermal and magnectic type with thimbles and nut-bolts complete all as specified and directed.
M&L in replacement MCB TP 63 Amp including suitable size of connectors complete all as specified and directed.
M&L in replacement MCB TP 32 Amp including suitable size of connectors complete all as specified and directed.
M&L in replacement wire connectors of size 10-16 sqmm in LT panels complete all as specified and directed.
M&L in replacement LED indicator lamp in LT panels as per existing size complete all as specified and directed.
S& F in replacement LED driver suitable for 45W LED street light complete all as specified and directed by Engr-in-charge.
S& F in replacement warm type LED bulb suitable for 9W bollard complete all as specified and directed by Engr-in-charge.
Removing old paint from surface of LT panel by scraping,rubbing and making good surface for painting and applying powder coated spary painting with existing colour one coat complete as specified and directed.
Complete removal of the wild grass/ vegetation from surrounding area of STP installations area and making the surface clear and plain and spraying roundup chemical on the same clean area as directed after removing and depositing the same at a distance not less than 50 mtr away from the site complete all as specified. Note T&P machinary will be provided by the contractor .
Scraping old existing paint from pipes of different sizes including making smooth surface and applying one coat of synthetic enamel paint as per existing/approved colour as specified and directed by Engr-in-charge.
Supply & Fixing in replacement water meter of 150 mm dia including flange , nut bolts.welding work etc as per site requirement complete all as specified and directed by Engr-in-Charge.
Obtaing the consent to operate for five years from Haryana State pollution control Board under water act for 1.5 MLD STP installation at allenby line in Sec C .Note:- Contractor will provide original payment details and consent from State pollution Board to department.
Supply and fixing in replacement flex board of minimum size 4feet x 3 feet including angle iron stand with painting complete all as specified and directed by Engr-in-Charge. Note:- Detail of printing material for flex will be provided by department.
M&L in replacement straight through joints (epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 16 to 35 sqmm 3.5/4.0 core and testing complete all as specefied and as directed.
M&L in replacement straight through joints (epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 50 to70 sq mm. 3.5 core and testing complete all as specefied and as directed.
S& F in replacement pressure die cast aluminium IP 66 roadway luminaire with high power LED building security light 15/18 W with electronic driver in light fitting and fitting shall be fixed on 40 mm GI pipe bracket fixed on wall with clamp complete all as specified and directed by Engr-in-charge.
S&F in replacement LED light fitting 230 volt, suitable for and including 1 x 19 Watt LED tube rod 4 feet size , energy efficient batten fitting with all accessories internally prewired and including connecting up with twin core cable complete all as specified and directed by Engr -in-Charge.
S&F in replacement post top latern decorative type 18W including fixing with suitable size GI pipe as required on the top of gate pillar as per direction and wiring complete , all as specified & directed by Engg-in - charge Make :-CG/Bajaj/Havells
S & F in replacement MCB single pole 6 Amps , 240 volts , having breaking capacity not less than 10 KA complete all as specified and directed by Engr-in-Charge
S & F in replacement MCB double pole 32 Amps , 240 volts , having breaking capacity not less than 10 kA complete all as specified and directed by Engr-in-Charge
S&F in replacement Electric Resistance Insulated Rubber Floor mat sheet of size 1mx2mx25mm thick ISI marked and equivalent colour as per direction with fixing mtrls complete all as specified and as directed.
S&F in replacement LED Street Light Luminaries 45 watt fitting New Generation,having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V all as specified and directed by Engr In charge.
S & F in replacement of flat/V belt coupled with air blower motor or pump motor set as per existing complete all as specified and directed by Engr-in-Charge.
Note :- Amount of credit of Rs. 81225.00 for retrieved materials is mentioned in Schedule of Credit mentioned in tender documents in pdf form which will be deducted offline while acceptance of tender.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .