Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹33.2 L
EMD Value
₹66,444
Closing Date
3 Dec 2026, 3:00 pm7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Office of Executive Engineer, ED-3rd Srinagar
Office of Executive Engineer, ED-3rd Srinagar
1.Creation of 250 kVA Substation along with HT/LT Network at Kikar Bagh Goripora of ESD Nawakadal . 2. Creation of 250 kVA Substation along with HT/LT Network at Dar Mohallah Khomani Chowk of ESD Watal kadal (Turnkey Basis)
2026_PDD_330289_1
ED-III /25 of 2026-27, Dated - 04/11/2026
Open Tender
Electrical Works
Turn-key
20 days
Office of Executive Engineer, ED-3rd Srinagar
Refer SBD, Technical Specifications, Drawing
7 documents required · 7 mandatory
₹1,000
Executive Engineer, ED-3rd Srinagar
₹66,444
3 Dec 2026
4 Nov 2026
4 Dec 2026
4 Nov 2026
3 Dec 2026
4 Nov 2026
4 Nov 2026 - 17 Nov 2026
180 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Sub-Station, HT Network, LT Network | |||||
| 1.01 | Supply, Installation, testing and commissioning of 250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-1 of BIS, Copper wound, and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. ( X-mer without OCTC (Off Ckt Tap Changer) including integration with system by way of providing Clamps/Jumpers/necessary items required for commissioning
1. 250 kVA Sub-Station at Kiker Bagh Goripora ESD Nawakadal - 01 No.
2. 250 kVA Sub-Station at Dar Mohallah Khomani Chowk ESD Watalkadal - 01 no. | 2 | No. | 6,54,733.86 | ₹13,09,467.72 |
| 1.02 | Supply, Installation, testing and commissioning of S.T. poles 9.0 Meter long swaged Type conforming to ST 410 SP-33, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 33). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
1. 250 kVA Sub-Station at Kiker Bagh Goripora ESD Nawakadal - 09 No.
2. 250 kVA Sub-Station at Dar Mohallah Khomani Chowk ESD Watalkadal - 15 no. | 24 | No. | 17,082.47 | ₹4,09,979.28 |
| 1.03 | Supply, Installation, testing and commissioning of S.T. poles 8.0 Meter long swaged Type conforming to ST 410 SP-15, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 15). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
1. 250 kVA Sub-Station at Kiker Bagh Goripora ESD Nawakadal - 08 No.
2. 250 kVA Sub-Station at Dar Mohallah Khomani Chowk ESD Watalkadal - 04 no. | 12 | No. | 13,832.17 | ₹1,65,986.04 |
| 1.04 | Supply, Laying, installation, testing and commissioning of 50 mm² ACSR Conductor
1. 250 kVA Sub-Station at Kiker Bagh Goripora ESD Nawakadal - 1700 mtrs
2. 250 kVA Sub-Station at Dar Mohallah Khomani Chowk ESD Watalkadal - 50 mtrs | 1,750 | Mtr | 69.24 | ₹1,21,170 |
| 1.05 | Supply, Laying, installation, testing and commissioning of 30 mm² ACSR Conductor
1. 250 kVA Sub-Station at Kiker Bagh Goripora ESD Nawakadal - 0 mtrs
2. 250 kVA Sub-Station at Dar Mohallah Khomani Chowk ESD Watalkadal - 1950 mtrs | 1,950 | Mtr | 41.44 | ₹80,808 |
| 1.06 | Supply, Laying, installation, testing and commissioning of 100 mm² ACSR Conductor
1. 250 kVA Sub-Station at Kiker Bagh Goripora ESD Nawakadal - 1500 mtrs
2. 250 kVA Sub-Station at Dar Mohallah Khomani Chowk ESD Watalkadal - 0mtrs | 1,500 | Mtr | 120.6 | ₹1,80,900 |
| 1.07 | Supply,installation, testing and commissioning of Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arrestor Set Heavy duty with Plymer Housing, Station type conforming to IEC-99-4 Capable of withstanding Maximum continuous operating voltages (M.C.O.V)
1. 250 kVA Sub-Station at Kiker Bagh Goripora ESD Nawakadal - 01 Set.
2. 250 kVA Sub-Station at Dar Mohallah Khomani Chowk ESD Watalkadal - 01 Set. | 2 | Set | 8,329.12 | ₹16,658.24 |
| 1.08 | Supply, installation, testing and commissioning of 11KV 200 Amperes, Triple pole switches Gang Operated (G.O. Set) conforming: IS-2544, IS: 5340 (Part-III) and SS: 9921 (Part-I -V)
1. 250 kVA Sub-Station at Kiker Bagh Goripora ESD Nawakadal - 01 Set
2. 250 kVA Sub-Station at Dar Mohallah Khomani Chowk ESD Watalkadal - 01 Set | 2 | Set | 10,955.13 | ₹21,910.26 |
| 1.09 | Supply, installation, testing and commissioning of 11 KV Horn, Gap (fuse 3-phase 200A) as per Relevant IS.
1. 250 kVA Sub-Station at Kiker Bagh Goripora ESD Nawakadal - 01 Set
2. 250 kVA Sub-Station at Dar Mohallah Khomani Chowk ESD Watalkadal - 01 Set | 2 | Set | 5,752.61 | ₹11,505.22 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.44 MB
BOQ_1120582.xls
BOQ • 0.33 MB
SBD25.pdf
Tender Documents • 1.45 MB
Combineapprovedkpdcl.pdf
Additional Documents • 28.39 MB
DTspecifications.pdf
Other Document • 0.70 MB
Extension2.pdf
PDF • 0.30 MB
Extension1-1.pdf
PDF • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .