Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC | L1 | Accepted-AOC Due to lowest rate | |
| 2 | L2₹28.9 L+₹4.5 L (18.3%)Rejected-Finance | L2 | Rejected-Finance Due to highest rate | |
| 3 | L3₹29.9 L+₹5.5 L (22.4%)Rejected-Finance | L3 | Rejected-Finance Due to highest rate | |
| 4 | L4₹30.8 L+₹6.4 L (26.3%)Rejected-Finance R O VILLAGE SAGNAHER P O CHAUNTRA TEHSIL JOGINDER NAGAR DISTT MANDI H P | L4 | Rejected-Finance Due to highest rate | |
| 5 | L5₹33.3 L+₹8.9 L (36.5%)Rejected-Finance HIMACHAL PRADESH | L5 | Rejected-Finance Due to highest rate |
Tender Value
₹18.6 L
EMD Value
₹35,400
Closing Date
13 Nov 2020, 11:00 amClosed
Executive Engineer
Executive Engineer Jal Shakti Division Shahpur
Construction of RCC main storage overhead tanks 120000 ltrs cap with 15mtrs staging height at Node No-2 and 35000 ltrs cap with 10mtrs staging height at Node No-3
2020_HPIPH_42240_1
No. SHP-KNG15-754/2020-8509-58 dated-06/11/2020
Open Tender
Civil Works
Lump-sum
180 days
Shahpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹400
Executive Engineer
₹35,400
Yes
22 Feb 2021
6 Nov 2020
13 Nov 2020
6 Nov 2020
13 Nov 2020
6 Nov 2020
6 Nov 2020 - 13 Nov 2020
Amount
Design and Construction of RCC Main over head storage tanks of 1,20,000 ltrs. capacity with 15 mtrs staging height and 35,000 ltrs. capacity with 10 mtrs staging height, including cost of excavation, site development cost of construction material , necessary arrangement of inlet,outlet, over flow & scour pipe alongwith sluice valves , & other fixtures & fitting, and carriage of meterial within all leads and lifts. ( The design and Drawing shall be got approved from competent authority before execution )
Inlet pipe shall be provided by the department, however the Contractor / Firm shall have to make arrangements for connection the same with the tank with in all leads and lifts.
Providing and fixing of atleast 1 number manhole with CI cover 500 milimeter internal dia meter total weight of cover and frame to be not less than 110 Kg. ( medium duty ) the weight of cover and frame to be 56 Kg. each.
Cast iron ventilating pipe 150 milimeter dia with cowl and mosquito proof cover of sufficient length and lightening conductor as per site shall be provided by the contractor/ firm.
RCC sprial stairs of 75 centimeter wide including railing of G.I pipe 40 milimeter dia ( midium class) supported on mild steel angle iron 40x40x5 ,o;o,eter pf jeogjt 90 centimeter from the ground level of the reservior to the top of the bottom ring beam and steel stairs from top of bottom ring beams to manehole to base of resvior.
All inspection gallery of minimum width 75 centimeter shall be provided around the tank at the bottom ring beam level along with railing of G.I. pipe of suitable dia supported on mild steel angle iron of 40x40x5 milimeter and also at ground level of the tank G.I. railing including mlld steel gate of suitable size . The pipe will be supplied by the department free of cost.
All other required accessories such as bell mouth control valves of cast iron class PN-1 one for each out let and occur system shall be supplied and fixed by the firm.
All the fitting shall be embeded in the structure while the work is in progress. All connections shall be left out side the structure with sluice valves of appropriate class and specification in position ready for connection with incomming and outgoing pipes . direction of the scour shall be made towards natural drainage as per direction of Engineer-in-charge.
The safe bearing capacity of the soil shall be got tested by the contractor, however for design purpose. The safe bearing capacity shall not be more than 10 tonne per square meter. The design and drawing for the structure shall be supplied by the contractor/firm and shall be got approved by the competent authority before execution of the work.
The work shall be executed as per techinical specification attached in the NIT and direction of Engineer-in-charge . All the surrounding shall be levelled and make good and brought in proper shape as per direction of Engineer-in-charge.
All the pipe fitting , valves and other specials shall be ISI marked and confirm to relevant BIS codes and also shall be subject to the approval of Engineer-in-charge.
TILAK RAJ SHARMA
SEWA SINGH
PARDEEP KUMAR
Ravinder Kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .