Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAdmitted-Finance PARUTHIYEZHATHU HOUSE MULAVUKAD P O NORTH ERNAKULAM 682 504 | ERNAKULAM | KERALA | 682504 | L1 | Admitted-Finance | |
| 2 | L2₹14.4 L+₹39,735 (2.84%)Admitted-Finance ITTIKUNNATH X 386 KOREPARAMBIL ROAD NJARACKAL ERNAKULAM 682505 | ERNAKULAM | ERNAKULAM | KERALA | 682505 | L2 | Admitted-Finance | |
| 3 | L3₹14.7 L+₹75,600 (5.41%)Admitted-Finance 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AR Traders L3 | HIGH TECH ENGINEERS AND CO L2 | GOLDEN EYE BUILDERS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and making good bottom surface for laying/ removing of cable, erection of poles in soft/ loose soil complete, all as specified and as directed. | 90 | Cum | 125 ₹11,250 | 220 ₹19,800 | 80 ₹7,200 Lowest |
| 2.00 | Material and labour for removing excavated soil to a distance not exceeding 50 meter and not exceeding 1.5 meter above the starting point, and depositing where directed complete, all as specified and as directed. | 20 | Cum | 100 ₹2,000 Lowest | 100 ₹2,000 Lowest | 100 ₹2,000 Lowest |
| 3.00 | Material and labour for Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and Above sand shall be obtained through digging at site 500 mtrs distance and transporting to site for punned use to sand cushioning up to 18cm thickness, complete all as specified and as directed
Note : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured. | 20 | Cum | 560 ₹11,200 | 500 ₹10,000 | 450 ₹9,000 Lowest |
| 4.00 | Material and labour for burnt bricks subclass B laid in trenches for cable protection complete all as specified and as directed. | 2.6 | Per 1000 nos | 2,650 ₹6,890 | 2,600 ₹6,760 | 2,000 ₹5,200 Lowest |
| 5.00 | Returning filling in excavated soil in trenches, watering and well ramming in layers not exc 25 cm complete all as specified. | 70 | Cum | 110 ₹7,700 | 70 ₹4,900 Lowest | 80 ₹5,600 |
| 6.00 | Taking out UNSV UG cables of any sizes from trenches/walls including all mounting accessories and GI tubing and keeping aside in safe custody for relaying after repairs including making good to disturbed areas, complete all as specified and as directed. | 815 | RM | 85 ₹69,275 | 25 ₹20,375 | 20 ₹16,300 Lowest |
| 7.00 | Relaying of UG cable Nominal cross section Area of 10 to 50 sqmm 2/4 core after testing, carrying out of joining works complete all as specified and as directed.
Note: - Necessary Joints will be measured and paid separately under relevant item of Sch A | 100 | RM | 35 ₹3,500 | 15 ₹1,500 Lowest | 18 ₹1,800 |
| 8.00 | Relaying of UG cable Nominal cross section Area of 70 to 150 sqmm 3.5 core after testing, carrying out of joining works complete all as specified and as directed.
Note: - Necessary Joints will be measured and paid separately under relevant item of Sch A | 100 | RM | 45 ₹4,500 | 20 ₹2,000 | 10 ₹1,000 Lowest |
| 9.00 | Material and labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 95 sqmm 3.5 core, 1100-volt grade, Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc complete all as specified and as directed. | 120 | RM | 1,000 ₹1,20,000 | 700 ₹84,000 Lowest | 800 ₹96,000 |
| 10.00 | Material and labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 120 sqmm 3.5 core, 1100-volt grade, Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc complete all as specified and as directed. | 100 | RM | 1,250 ₹1,25,000 | 950 ₹95,000 | 945 ₹94,500 Lowest |
Tender Value
₹14.8 L
EMD Value
₹29,500
Closing Date
3 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
REPAIR/ MIANT OF REPLACEMENT OF LT UG CABLES, LT PANEL BOARDS/ FEEDER PILLAR, APFC PANELS, SWITCH GEARS ETC AND INCL COMPREHENSIVE MAINT OF APFC PANELS AND CONNECTED WORKS AT INS DRONACHARYA UNDER GE FORT KOCHI
2026_MES_787935_1
8396/E8_GE_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
FORT KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹29,500
Yes
22 Oct 2026
5 Sept 2026
10 Oct 2026
5 Sept 2026
3 Oct 2026
19 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and making good bottom surface for laying/ removing of cable, erection of poles in soft/ loose soil complete, all as specified and as directed. | 90 | Cum | - | - |
| 2 | Material and labour for removing excavated soil to a distance not exceeding 50 meter and not exceeding 1.5 meter above the starting point, and depositing where directed complete, all as specified and as directed. | 20 | Cum | - | - |
| 3 | Material and labour for Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and Above sand shall be obtained through digging at site 500 mtrs distance and transporting to site for punned use to sand cushioning up to 18cm thickness, complete all as specified and as directed
Note : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured. | 20 | Cum | - | - |
| 4 | Material and labour for burnt bricks subclass B laid in trenches for cable protection complete all as specified and as directed. | 2.6 | Per 1000 nos | - | - |
| 5 | Returning filling in excavated soil in trenches, watering and well ramming in layers not exc 25 cm complete all as specified. | 70 | Cum | - | - |
| 6 | Taking out UNSV UG cables of any sizes from trenches/walls including all mounting accessories and GI tubing and keeping aside in safe custody for relaying after repairs including making good to disturbed areas, complete all as specified and as directed. | 815 | RM | - | - |
| 7 | Relaying of UG cable Nominal cross section Area of 10 to 50 sqmm 2/4 core after testing, carrying out of joining works complete all as specified and as directed.
Note: - Necessary Joints will be measured and paid separately under relevant item of Sch A | 100 | RM | - | - |
| 8 | Relaying of UG cable Nominal cross section Area of 70 to 150 sqmm 3.5 core after testing, carrying out of joining works complete all as specified and as directed.
Note: - Necessary Joints will be measured and paid separately under relevant item of Sch A | 100 | RM | - | - |
| 9 | Material and labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 95 sqmm 3.5 core, 1100-volt grade, Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc complete all as specified and as directed. | 120 | RM | - | - |
| 10 | Material and labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 120 sqmm 3.5 core, 1100-volt grade, Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc complete all as specified and as directed. | 100 | RM | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
8396Tenderdocu.pdf
Tender Documents • 1.03 MB
BOQ_883115.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .