Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.1 LAccepted-AOC 66 102 ARUN JYOTHI MULLASSERY CANAL ROAD ERNAKULAM KOCHI 682 011 | KOCHI | ERNAKULAM | KERALA | 682011 | L1 | Accepted-AOC Lower Bidder | |
| 2 | L2₹61.6 L+₹2.1 L (3.46%)Rejected-Finance | L2 | Rejected-Finance Higher Bid Value | |
| 3 | L3₹61.7 L+₹2.2 L (3.64%)Rejected-Finance | L3 | Rejected-Finance Higher Bid Value | |
| 4 | L4₹62.0 L+₹2.4 L (4.09%)Rejected-Finance 37 1634 IMPERIAL HOUSE KALOOR KATHRIKADAVU KATHRIKADAVU ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | L4 | Rejected-Finance Higher Bid Value | |
| 5 | L5₹63.9 L+₹4.3 L (7.26%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Higher Bid Value |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
2 Jun 2021, 6:00 pmClosed
Col Bhaskar Jha CWE
CWE Ezhinama INA PO Kannur Kerlala 670310
Special Repairs to HT system by replacing two pole four pole structure in RMU with HT UG cable at INA Ezhimala
2021_MES_440340_1
80426/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
Ezhimala
As per tender documents
2 documents required · 2 mandatory
₹1,000
GE(Maint) Ezhimala
₹1.3 L
Yes
26 Jul 2021
4 May 2021
4 Jun 2021
4 May 2021
2 Jun 2021
20 May 2021
4 May 2021 - 20 May 2021
Amount
Dismantling steel poles of any type complete all as specified and as directed by Engineer- in- charge.
Taking down old unserviceable overhead ACSR conductor of any type complete all as specified and as directed by Engineer- in- charge.
Taking down old unserviceable MS chanel,cross arm, clamp, and all accessoties complete all as specified and as directed by Engineer- in- charge.
Taking down old unserviceable insulator of any size/type complete all as specified and as directed by Engineer- in- charge.
Dismantling gang operated Air break switch vertical/horizontal mounted triple pole mechanically operated for replacement all as specified and as directed by Engineer- in- charge.
Taking down/out HT UG cable of size up to 300 sqmm including removing electrical connection and keeping aside serviceable cable including removing cable protection cover etc all as specified and as directed by Engineer- in- charge. Note: The unserviceable cable retrieved from taking down will become contractor's property and recovery will be made under schedule of credit.
Supply and laying XLPE insualted screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 11000 volts grade earthed cross sectional area 95 sqmm 3 core and all as specified and as directed by Engineer- in- charge.
Exacavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard and dense soil all as specified and as directed.
Returing and filling in including levelling watering and well ramming into layers not exceeding 25 cm in hard/dense soil
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from starting point.
Supply and spreading river sand/ribbed earth for cushioning and covering of the UG cable in trenches all as specified and directed.
Supply and laying un reinforced precast concrete cable cover class HV type 1 flat size:- 300 mm x 180 mm x 40 mm and all as specified and as directed by Engineer- in- charge.
Relaying un reinforced precast concrete cable cover class HV type 1 flat size:- 300 mm x 180 mm x 40 mm obtained from item no 06 complete all as directed by Engineer-In-Charge.
Relaying serviceable HT UG cable of size up to 300 sqmm obtained from item no 06 complete all as directed by Engineer-In-Charge.
M &L for Supply ,installation,Testing and commissioning of SF6 insulated outdoor type Ring main unit 11kV, 630A, 21kA for 3 sec. Motorized both Side Extensible,3way module consisting of 1No Load break switch and 2 No Vaccum circuit breaker ,Each unit is made of a robotically welded sealed for life tank of thickness not less than 2.5mm filled with SF6,containing all high voltage components sealed off from the environment with Ingress protection IP67.(Enclosure should meet sealed pressure system criterion in accordance with IEC 62271-200)– RMU with enclosure with Internal arc classification compiled to IEC 62271, Nominal voltage: 11 kV ,Rated frequency: 50 Hz, copper busbars of 630 A rating, Rated copper current cable switch disconnector: 630 A, Rated current for transformer T-off: 200 / 630 A ,Pressure of SF6 gas: 1.4 bar at 20 °C . Short time withstand current: Cable switch disconnector with interface C(400-bolt) bushing: 21 kArms 3 sec., Vacuum circuit breaker with interface C (400-bolt) bushing: 21 kArms 3 sec.
( Item No.15 Contd) - Impulse withstand voltage: To earth and between phases: 75 kV, Insulation level: - Power frequency 1 min: 28 kV, Temperature class: -25 °C - +40 °C outdoor , SF6 tank: IP 67, Fuse canisters: IP 67, Front cover: IP 2X, Cable cover: IP 3X, Enclosure IP54, Metal Enclosed switchgear: IEC 62271-200, General Purpose switches: IEC 60265-1, Disconnectors and Earthing switches: IEC 62271-102, Switch Fuse Combination: IEC 62271-105, Circuit Breakers: IEC 62271-100. LBS module housed in SF6 Cubicle consisting : Cable switch 12kV, 630A -1no, Bushings outside cone interface C for connection of external busbars-1no, Manometer-1no, Snap action mech. for motor operation -1no, Control voltage, motor operation 24 V DC-1no, Cable cover standard with Interlocking-1no, Cable bushings interface C (400 bolted), 630 A, standard-1no, Short Circuit and Earth Fault Indicator -1no, Capacitive voltage indication fixed type VPIS 9-15 Kv -1no, Aux. switch for load break switch position 2NO + 2NC -1no, Cable support bars, standard for 1-way unit-1no
( Item No.15 Contd) - VCB module housed in SF6 Cubicle consisting: Vacuum circuit breaker 12kV, 630A,(Vaccum bottles are used as interrupters of the fault currents)-1no, Stored energy mech. for motor operation-1no, Control voltage, motor operation 24 V DC-1no, Cable cover standard with Interlocking-1no, Self-Powered Over Current and Earth Fault protection relay with RS485 port type ADR241S/CSDPR-1no, Cable bushings interface C (400 bolted), 630A-1no, Aux. switch for vacuum circuit breaker position 2NO + 2NC-1no, Capacitive voltage indication fixed type VPIS 6-12 kV-1no, Cable support bars, standard for 1-way unit-1no, Ring core current transformer type 100/1 A, 2.5VA, 5P10 for Protection-3nos. All as specified and directed by Engr-in-charge. Note:-The cost of Earthwork, foundation and plinth for installation of RMU shall be deemed to be included in the quoted rate. Design and dimention of concrete structure will be as per the manufacturer instruction and all as specified and directed by Engr-in-charge. MAKE:ABB,Seimens,Schneider.
M &L for Supply ,installation,Testing and commissioning of SF6 insulated outdoor type Ring main unit 11kV, 630A, 21kA for 3 sec. Motorized both Side Extensible,4 way module consisting of 1 No Load break switch and 3 No Vaccum circuit breaker ,Each unit is made of a robotically welded sealed for life tank of thickness not less than 2.5mm filled with SF6,containing all high voltage components sealed off from the environment with Ingress protection IP67.(Enclosure should meet sealed pressure system criterion in accordance with IEC 62271-200)– RMU with enclosure with Internal arc classification compiled to IEC 62271, Nominal voltage: 11 kV ,Rated frequency: 50 Hz, copper busbars of 630 A rating, Rated copper current cable switch disconnector: 630 A, Rated current for transformer T-off: 200 / 630 A ,Pressure of SF6 gas: 1.4 bar at 20 °C . Short time withstand current: Cable switch disconnector with interface C(400-bolt) bushing: 21 kArms 3 sec., Vacuum circuit breaker with interface C (400-bolt) bushing: 21 kArms 3 sec.
( Item No.16 Contd) - Impulse withstand voltage: To earth and between phases: 75 kV, Insulation level: - Power frequency 1 min: 28 kV, Temperature class: -25 °C - +40 °C outdoor , Degree of protection: - SF6 tank: IP 67, Fuse canisters: IP 67, Front cover: IP 2X, Cable cover: IP 3X, Enclosure IP54, Metal Enclosed switchgear: IEC 62271-200, General Purpose switches: IEC 60265-1, Disconnectors and Earthing switches: IEC 62271-102, Switch Fuse Combination: IEC 62271-105, Circuit Breakers: IEC 62271-100.General Purpose switches: IEC 60265-1, Disconnectors and Earthing switches: IEC 62271-102, Switch Fuse Combination: IEC 62271-105, Circuit Breakers: IEC 62271-100. LBS module housed in SF6 Cubicle consisting : Cable switch 12kV, 630A -1no, Bushings outside cone interface C for connection of external busbars-1no, Manometer-1no, Snap action mech. for motor operation -1no, Control voltage, motor operation 24 V DC-1no, Cable cover standard with Interlocking-1no, Cable bushings interface C (400 bolted), 630 A, standard-1no, Short Circuit and Earth Fault Indicator -1no, Cable support bars, standard for 1-way unit-1no
( Item No.16 Contd) Capacitive voltage indication fixed type VPIS 9-15 Kv -1no, Aux. switch for load break switch position 2NO + 2NC -1no, VCB module housed in SF6 Cubicle consisting: Vacuum circuit breaker 12kV, 630A,(Vaccum bottles are used as interrupters of the fault currents)-1no, Stored energy mech. for motor operation-1no, Control voltage, motor operation 24 V DC-1no, Cable cover standard with Interlocking-1no, Self-Powered Over Current and Earth Fault protection relay with RS485 port type ADR241S/CSDPR-1no, Cable bushings interface C (400 bolted), 630A-1no, Aux. switch for vacuum circuit breaker position 2NO + 2NC-1no, Capacitive voltage indication fixed type VPIS 6-12 kV-1no, Cable support bars, standard for 1-way unit-1no, Ring core current transformer type 100/1 A, 2.5VA, 5P10 for Protection-3nos. All as specified and directed by Engr-in-charge. Note:-The cost of Earthwork, foundation and plinth for installation of RMU shall be deemed included in the quoted rate. Design and dimention of concrete structure will be as per the manufacturer instruction and all as specified and directed by Engr-in-charge. MAKE:ABB,Seimens,Schneider
M &L for Supply ,installation,Testing and commissioning of SF6 insulated outdoor type Ring main unit 11kV, 630A, 21kA for 3 sec. Motorized both Side Extensible, 6 way module consisting of 2 No Load break switch and 4 No Vaccum circuit breaker ,Each unit is made of a robotically welded sealed for life tank of thickness not less than 2.5mm filled with SF6,containing all high voltage components sealed off from the environment with Ingress protection IP67.(Enclosure should meet sealed pressure system criterion in accordance with IEC 62271-200)– RMU with enclosure with Internal arc classification compiled to IEC 62271, Nominal voltage: 11 kV ,Rated frequency: 50 Hz, copper busbars of 630 A rating, Rated copper current cable switch disconnector: 630 A, Rated current for transformer T-off: 200 / 630 A ,Pressure of SF6 gas: 1.4 bar at 20 °C . Short time withstand current: Cable switch disconnector with interface C(400-bolt) bushing: 21 kArms 3 sec., Vacuum circuit breaker with interface C (400-bolt) bushing: 21 kArms 3 sec.
( Item No.17 Contd) - Impulse withstand voltage: To earth and between phases: 75 kV, Insulation level: - Power frequency 1 min: 28 kV, Temperature class: -25 °C - +40 °C outdoor , Degree of protection: - SF6 tank: IP 67, Fuse canisters: IP 67, Front cover: IP 2X, Cable cover: IP 3X, Enclosure IP54, Metal Enclosed switchgear: IEC 62271-200, General Purpose switches: IEC 60265-1, Disconnectors and Earthing switches: IEC 62271-102, Switch Fuse Combination: IEC 62271-105, Circuit Breakers: IEC 62271-100. LBS module housed in SF6 Cubicle consisting : Cable switch 12kV, 630A -1no, Bushings outside cone interface C for connection of external busbars-1no, Manometer-1no, Snap action mech. for motor operation -1no, Control voltage, motor operation 24 V DC-1no, Cable cover standard with Interlocking-1no, Cable bushings interface C (400 bolted), 630 A, standard-1no, Short Circuit and Earth Fault Indicator -1no, Capacitive voltage indication fixed type VPIS 9-15 Kv -1no, Aux. switch for load break switch position 2NO + 2NC -1no, Cable support bars, standard for 1-way unit-1noCable support bars, standard for 1-way unit-1no
( Item No.17 Contd) - VCB module housed in SF6 Cubicle consisting: Vacuum circuit breaker 12kV, 630A,(Vaccum bottles are used as interrupters of the fault currents)-1no, Stored energy mech. for motor operation-1no, Control voltage, motor operation 24 V DC-1no, Cable cover standard with Interlocking-1no, Self-Powered Over Current and Earth Fault protection relay with RS485 port type ADR241S/CSDPR-1no, Cable bushings interface C (400 bolted), 630A-1no, Aux. switch for vacuum circuit breaker position 2NO + 2NC-1no, Capacitive voltage indication fixed type VPIS 6-12 kV-1no, Cable support bars, standard for 1-way unit-1no, Ring core current transformer type 100/1 A, 2.5VA, 5P10 for Protection-3nos.All as specified and directed by Engr-in-charge. Note:-The cost of Earthwork, foundation and plinth for installation of RMU shall be deemed included in the quoted rate. Design and dimention of concrete structure will be as per the manufacturer instruction and all as specified and directed by Engr-in-charge. MAKE:ABB,Seimens,Schneider
M &L for Supply ,installation,Testing and commissioning of SF6 insulated outdoor type Ring main unit 11kV, 630A, 21kA for 3 sec. Motorized both Side Extensible,8 way module consisting of 4 No Load break switch and 4 No Vaccum circuit breaker ,Each unit is made of a robotically welded sealed for life tank of thickness not less than 2.5mm filled with SF6,containing all high voltage components sealed off from the environment with Ingress protection IP67.(Enclosure should meet sealed pressure system criterion in accordance with IEC 62271-200)– RMU with enclosure with Internal arc classification compiled to IEC 62271, Nominal voltage: 11 kV ,Rated frequency: 50 Hz, copper busbars of 630 A rating, Rated copper current cable switch disconnector: 630 A, Rated current for transformer T-off: 200 / 630 A ,Pressure of SF6 gas: 1.4 bar at 20 °C . Short time withstand current: Cable switch disconnector with interface C(400-bolt) bushing: 21 kArms 3 sec., Vacuum circuit breaker with interface C (400-bolt) bushing: 21 kArms 3 sec.
( Item No.18 Contd) - Impulse withstand voltage: To earth and between phases: 75 kV, Insulation level: - Power frequency 1 min: 28 kV, Temperature class: -25 °C - +40 °C outdoor , Degree of protection: - SF6 tank: IP 67, Fuse canisters: IP 67, Front cover: IP 2X, Cable cover: IP 3X, Enclosure IP54, Metal Enclosed switchgear: IEC 62271-200, General Purpose switches: IEC 60265-1, Disconnectors and Earthing switches: IEC 62271-102, Switch Fuse Combination: IEC 62271-105, Circuit Breakers: IEC 62271-100. LBS module housed in SF6 Cubicle consisting : Cable switch 12kV, 630A -1no, Bushings outside cone interface C for connection of external busbars-1no, Manometer-1no, Snap action mech. for motor operation -1no, Control voltage, motor operation 24 V DC-1no, Cable cover standard with Interlocking-1no, Cable bushings interface C (400 bolted), 630 A, standard-1no, Short Circuit and Earth Fault Indicator -1no, Capacitive voltage indication fixed type VPIS 9-15 Kv -1no, Aux. switch for load break switch position 2NO + 2NC -1no, Cable support bars, standard for 1-way unit-1no
( Item No.18 Contd) - VCB module housed in SF6 Cubicle consisting: Vacuum circuit breaker 12kV, 630A,(Vaccum bottles are used as interrupters of the fault currents)-1no, Stored energy mech. for motor operation-1no, Control voltage, motor operation 24 V DC-1no, Cable cover standard with Interlocking-1no, Self-Powered Over Current and Earth Fault protection relay with RS485 port type ADR241S/CSDPR-1no, Cable bushings interface C (400 bolted), 630A-1no, Aux. switch for vacuum circuit breaker position 2NO + 2NC-1no, Capacitive voltage indication fixed type VPIS 6-12 kV-1no, Cable support bars, standard for 1-way unit-1no, Ring core current transformer type 100/1 A, 2.5VA, 5P10 for Protection-3nos. All as specified and directed by Engr-in-charge. Note:-The cost of Earthwork, foundation and plinth for installation of RMU shall be deemed included in the quoted rate. Design and dimention of concrete structure will be as per the manufacturer instruction and all as specified and directed by Engr-in-charge. MAKE:ABB,Seimens,Schneider.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
All as per item no 20 above but size 300 sqmm
Supply and jointing straight through cable jointing kit HT 11 KV (Earthed) grade , straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE Armoured aluminium conductor cable of size 95 sqmm complete all as specified Make 3M,Rechem, Mseal
All as per item no 22 above but size 300 sqmm
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground(earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal GL, connected to and including galvanized earth lead Strip of size 32mmx6mm upto 7.5 m distance and connected by means of bolts,nuts,checknuts and washers of galvanized iron or steel all as shown in electrical plate No.3 in SSR connected to earthing test point all as specified complete with excavation, earth work in any strata, charcoal, salt , pcc chamber,20mm thick RCC cover (grade M 15) complete having suitable handle (10mm MS Rod) , 20 mm dia medium grade GI pipe for watering with GI funnel & wire mesh and 40mm bore GI pipe light grade for protection of earth lead conductor with testing and connecting up complete all as specified and directed by engr-in-charge
Supply and fix GI tubing light grade 80 mm nominal dia in trench/road/pole for cable protection complete all as specified and directed
Supply and fix Route indicator for marking of HT/ UG cable with cast iron round plate of 150 mm dia with cable direction arrow suitably fitted on iron and embeded with PCC block size of 25x25x 30cm complete all as specified.
Cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.25 Mtr and depth 0.75 mtr all as directed and making good with PCC (1:2:4) type 'B-1' as required at site to match with the existing surface complete all as specified and directed by Engineer -in-charge.
PHEJAYS AGENCIES
B5BUILDING SOLUTIONS
IMPERIAL ENGINEERING COMPANY
NAVREET CONSTRUCTION
LUCKY ENTERPRISES
devan enterprises
Linsta Services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .