| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 LAccepted-AOC MEHEM ROAD NEAR TVS BIKE AGENCY GOHANA SONIPAT HARYANA 131301 ON MEHAM ROAD NEAR TVS BIKE AGENCY GOHANA 131301 | SONIPAT | HARYANA | 131301 | L1 | Accepted-AOC work allotted |
Tender Value
₹83,000
EMD Value
₹1,660
Closing Date
15 Jan 2021, 2:00 pmClosed
Executive Engineer
Executive Engineer, Elect. Division PWD BandR Br., Karnal (0184-2265696)
Construction of Govt. Sub Health Centre at Village Nayat Distt. Sonipat (Pdg. EI only). Recall
2021_HRY_154955_1
154955 SHC Nayat
Open Tender
Electrical Works
Works
150 days
Sonipat
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹1,660
26 Mar 2021
1 Jan 2021
15 Jan 2021
1 Jan 2021
15 Jan 2021
1 Jan 2021
Amount
HSR 31.12 (a) (v) Cat-B Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections. Double pole switch 32 amp. 415 Volts,
HSR 31.13 Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 40 mm x 40 mm x 6 mm.
HSR 31.14 Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
HSR 31.17 Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
HSR 31.18 Supply and erection of Fittings and Accessories. Bakelite angle / straight button holder large size.
HSR 31.18 (xxiv) Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
HSR 31.18 (xxvi) Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job.
HSR 31.20 (i) Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
HSR 31.20 (iii) Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work.
HSR 31.20 (v) Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
HSR 31.20 (vi) Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
HSR 31.21 (xiii) Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Galvanised iron pipe 50 mm dia on flushed.
HSR 31.21 (xxi) Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed.
31.21(xxx) Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. PVC pipe 80 mm dia.
HSR 31.22(i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
HSR 31.22(ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
HSR 31.22(xii)Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required .
HSR 31.22(xvi) Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required .
HSR 31.26 (iv) Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 10 Sq. mm 2 Core Cable (Ard.).
HSR 31.26 (v) 6 Sq. mm 2 Core Cable . (Ard.)
HSR 31.30 (III) ( xv ) Supply and erection of 32 mm dia meter 1.5 meter long bracket ( B-Class ) making an angle of 10 to 15 degree with horizontal plane for mounting street light fitting fixing of GI bracket on wall with 2 Nos. , 32 mm x 3 mm thick MS clamps including the cost of cutting , welding of GI pipe complete with cement sand mixture , bolts and nuts etc. including necessary connections .
HSR 31.36 Wiring in 1.5 sq.mm PVC Insulated Copper conductor cable in 1.6 mm thick conduit pipe. Fan Point Medium
Light Point Short point
Medium Point
Long point.
Call bell point including M.S box of size 180 mmX100 mmX 60 mm deep for Call bell. Medium Point
3 pin 5 amp. plug point including earthing the 3rd. pin etc. Short point
Medium Point
3 pin15 amp. plug point with 4 sq mm PVC insulated Copper conductor cable- including earthing the 3rd. pin etc. Short point
Medium Point
Long point.
HSR 31.40 Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe . Size 1.5 sqmm ( 3/0.81 )
Size 4 sqmm ( 7/0.85 )
HSR 31.41 Supply and erection of Double door sheet steel enclosure distribution boards suitable for MCB's & ELCB's recessed in wall including bonding to earth complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 12-way , SP&N ( Horizontal)
HSR 31.44 Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. 25 mm dia.
HSR 31.48 Supply and erection of MS Saddle and clamps duly galvanised , on wall / RCC parapit for fixing underground cable at a distance of 0.60 meter center to center fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect and upto entire satisfaction of the Engineer-in-charge of work.
HSR 31.55 Supply & erection of Socket size rotary step type Electronic regulator for A.C. ceiling fan Anchor make Delux model No. 50440 ISI / SSK make PC 561 operated on 120/280 V A.C. Supply complete including cutting of existing Bakelite sheet and making necessary connection etc. up to the entire satisfaction of the Engineer-in-Charge of the Work.
HSR 31.67 S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 mtr. below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-incharge of the work HDPE pipe 63 / 50mm outer dia / inner dia.
NS item Supply and erection of LED Streetlight 72W Luminaires of Makes: Bajaj / Crompton / GE / Philips / Wipro with Pressure die cast aluminium housing with lens and accessories required to complete the job in all respect including erection on existing pole for fixing including connection of the same upto the entire satisfaction of Engineer in Charge of the work.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .