Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 196 GOREGAON W MUMBAI MAHARASHTRA 400062 | 400062 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹47,200
EMD Value
₹1,416
Closing Date
27 Mar 2023, 6:00 pmClosed
Col Kshitij Srivastava, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
SOIL INVESTIGATION FOR THE WORK DEMOLITION/ RECONSTRUCTION OF WATCH TOWER NO 3 AT MO (V) NEW SITE GE ND VISAKHAPATNAM
2023_MES_583622_1
31004/DS/E3
Open Tender
Civil Works
Item Rate
15 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹300
Yes
GE ND
₹1,416
Yes
Garrison Engineer Naval Depot, Visakhapatnam - 530
11 Apr 2023
1 Mar 2023
29 Mar 2023
1 Mar 2023
27 Mar 2023
8 Mar 2023
1 Mar 2023
Amount
(1) Mobilisation of equipment for detailed soil investigation and shifting them from one location to other location of boreholes and for in site tests (for 1 bore holes) (2) Boring holes 150 mm dia in any type of soil, but excluding any type of rock upto a depth as directed by Engineer-in-Charge for conducting following activities (1 bore hole upto minimum depth of refusal not exc 10 m deep) (a) Conduct of SPT at every 1.5m inteval or change of strata whichever occurs earlier. (b) Collection of undistrubed soil samples (UDS) at every 1.5m interval or change of strata whichever occurs earlier ( a minimum gap of 500mm shall be ensured between SPT and collection of UDS). (3) Conduct of following laboratory tests as per relevant Indian Standards (IS 2720 (all parts),IS 1498 and IS 3025) on soil samples collected:- (a) Test on disturbed/ undisturbed soil samples (i) Visual and Engineering classification (As reqd basis, not execeeding 10 Nos per bore hole) (ii) Sieve analysis and hydrometer analysis (As reqd basis, not exceeding 10 Nos per bore hole) (iii) Atterberg limits (liquid limit, plastic limit and shrinkage limit) (As reqd basis, Not exceeding 10 Nos per bore hole) (iv) Specific gravity : (As reqd basis, not exceeding 10 Nos per bore hole) (v) Free swell index : (As reqd basis, not exceeding 10 Nos per bore hole) (b) Test on undisturbed soil samples (As reqd basis, not exceeding 10 Nos per bore hole) (i) Buld density and moisture content
(ii) Unconfined compression test (on undisturbed and remoulded sample) (iii) Swelling pressure (on undisturbed and remoulded sample) (iv) Determination of C & O values using direct shear (drained/undrained) (on remoulded or undisturbed sample or Triaxial compression tests (on undisturbed or remoulded sample) or Vane shear test. 4. Chemical analysis of soil samples one each from each strata in respect of one borehole. If different strata (s) encountered in any other borehole additional soils samples to be analysed. (5) Submission of report consisting of bore logs, data sheets with laboratory test results and recommendations for the type of foundation for contruction of structures in case where pile foundation area is recommended vertical, uplift and lateral load capacity of piles to be clearly mentioned/ brought out in the report duly vetted by any of IIT/NIT/Andhara University. The above rates are inclusive of all requirements/ details given below. Note Composition of subsurface investigation report General On completion of the insite and laboratory tests, subsurface investigation report shall be parted which should include geological information, procedure adopted for investigation, filed obervation, laboratory or test information to be provided. The report shall be included but not be limited to the following : (a) Dimentional plan shoeing location and depth of in-situ tests the coordinated of borehole location with reference to prominent permanent features of the site duly signed by GE and Geo consultant. (b) Geological information of the area.
(c) General topography of the site, duly marking RL of hte location of boreholes with reference to RL of nearby permannet features avaiable at site duly signed by GE. (d) Past usage and historical data of the site, if availabe informatio regarding following of the site in the past, high flood level etc. (e) Bore-log and trial pit log duly signed by GE and Geo consultant (f) In-situ test results. (g) Plot of standard penetration test (N values both uncorrected and corrected) with depth for identified areas. (h) Laboratory test results. (j) Summary of strata profile.
IDDC Engineers Private Limited
D2D ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .