Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC | ₹1.8 L | L1 | Accepted-AOC Accepted vide Resolun No 2(2) dtd 10/2/2026 of Alathur gp |
| 2 | L2₹1.9 LRejected-AOC | ₹1.9 L | L2 | Rejected-AOC higher rate hence rejected |
Tender Value
₹1.8 L
EMD Value
₹4,562
Closing Date
2 Feb 2026, 4:00 pmClosed
K Sunilkumar
O/o of the Assist Engineer, LIDEW Section,Alathur
Alathur GP-2025-26 Meeting hall renovation at Alathur Grama panchayath (project No S0092/25-Electrification
2026_LSGD_830349_6
06/AE/LID EW/ALR/2025-26/ET6
Open Tender
Electrical Works
180 days
Alathur Grama Panchayat
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹4,562
Yes
17 Apr 2026
24 Jan 2026
3 Feb 2026
24 Jan 2026
2 Feb 2026
24 Jan 2026
1.Electrification.
OD360984/2025-2026:Supply, conveyance and fixing 6 w LED Energy Surface mounding Round/ Square Panel light fittings in the existing ceiling LEPSRR06 LUKER or equivalent make and giving connections etc as required including all labour charges.
OD360985/2025-2026:Supply, conveyance and fixing 12 w LED Energy Surface mounding Round/ Square Panel light fittings in the existing ceiling LEPSRR06 LUKER or equivalent make and giving connections etc as required including all labour charges.
90.2.1.7:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
OD360971/2025-2026:Supply and fixing 2 Nos. 2 MD Metal box with 2 Nos. white front plate on 1 No. 20A modular type DP Switch with indicator and 25A shuttered socket, earthing make good the damages color washing etc as required on recess as power plug(ROHS) for A / C
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD363464/2025-2026:Supply & Fixing 4 Pole enclosure MCB DB sheet steel phosphatized , painted, dust and vermin proof on surface/ recess etc. as required. 4 Pole enclosure MCB DB sheet steel phosphatized , painted, dust and vermin proof on surface/ recess etc. asrequired.
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
OD360970/2025-2026:Supply and providing12x3mm brass nut and bolt etc.as required.
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
OD363460/2025-2026:Supply and fixing LED drive 2A (LSD02) including giving all connections etc. complete including labour all charges.
OD363461/2025-2026:Supply and fixing flexible LED Strip (2835) in the existing ceiling and giving necessary connection etc. complete including all charges
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
OD363501/2025-2026:Dismantling the existing damaged wiring points such as light points, fan point, plug points, DBs etc and hand over to the concerned authorities
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.22.1:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.75 mm X 75 mm X 60 mm deep
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_1394998.pdf
finsummary_1394998.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tendernotice_2.pdf
PDF • 0.25 MB
Tendernotice_3.pdf
PDF • 0.25 MB
BOQ_1394998.xls
BOQ • 0.35 MB
viewnit.pdf
Tender Documents • 0.03 MB
pre.pdf
Tender Documents • 0.26 MB
viewsbd.pdf
Tender Documents • 1.64 MB
fot.pdf
Tender Documents • 0.26 MB
aff.pdf
Tender Documents • 0.24 MB
Download all tender documents and submit your bid