| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.5 LAccepted-AOC AT PO NEAR SAHID CHOUK TANDWA DISTT CHATRA JHARKHAND 825321 | CHATRA | JHARKHAND | 825321 | ₹2.5 L | L-1 | Accepted-AOC Accepted as being L-1 bidder and acceptable rate |
| 2 | Rejected-Technical ALAKHRAJ BHAWAN NEAR MAMTA MOTORS BHUSA MORE WARD NO 7 SINGRAULI M P 486889 | SINGRAULI | MADHYA PRADESH | 486889 | - | - | Rejected-Technical Not opened for technical evaluation hence rejected as being L-3 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not opened for technical evaluation hence rejected as being L-2 |
| Sl No | Description | Qty | Unit | M/s GYANENDRA TIWARI L2 | AJAY ENTERPRISES L1 | ANNAPURNA CONSTRUCTION COMPANY L3 |
|---|---|---|---|---|---|---|
| 1.01 | Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140–270 Volt AC, Frequency 50/60 Hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L-N, as per IEC 61000-4-5, Driver efficiency >85%, THD <10% as per IEC 61000-3-2, P.F ≥0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type II/III as per the width of the road and the project requirement, suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000K / 4000K / 5700K / 6500K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect of external connections with 1.5 sq.mm FRLS/HRFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. Thermal management heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C.
(A)100 Watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt) as required.) | 50 | Nos. | 2,500 ₹1,25,000 Lowest | 3,000 ₹1,50,000 | 2,800 ₹1,40,000 |
| 1.02 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 Hz. Operating temp range -5°C to 50°C, internal surge protection of 5 KV L-N, E as per IEC 61000-4-5, Driver efficiency >85%, THD <10% as per IEC 61000-3-2, P.F ≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30°–120° as per the application and the project requirement, suitable fit able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000K / 4000K / 5700K / 6500K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect of external connections with 1.5 sq.mm FRLS/HRFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty, System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-In-Charge as per requirement. Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C.
(A) 250 watt LED Flood light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) as required. | 30 | Nos. | 5,000 ₹1,50,000 | 3,450 ₹1,03,500 Lowest | 5,300 ₹1,59,000 |
| 2.00 | Total impact of GST for the purpose of CTC | 1 | Nos | - | - | - |
Tender Value
₹4.2 L
EMD Value
₹5,300
Closing Date
10 Mar 2026, 5:00 pmClosed
STAFF OFFICER ENM SECL HSD AREA
OFFICE OF THE AREA GENERAL MANAGER, HASDEO AREA PO SOUTH JHAGRAKHAND COLLIERY DISTT MCB (CG) PIN 497448
Replacement of Burnt/ Damaged Street Light Fitting at Magazine, Palkimara, Central Substation, CISF Camp and Unit Store WJKD of JKD Sub Area under Hasdeo Area
2026_SECL_354786_1
AGM/HSD/SO(EnM)/E-Tender/82, dt.28.02.2026
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Hasdeo Area
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,300
22 Jul 2026
28 Feb 2026
11 Mar 2026
28 Feb 2026
10 Mar 2026
28 Feb 2026
28 Feb 2026 - 7 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140–270 Volt AC, Frequency 50/60 Hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L-N, as per IEC 61000-4-5, Driver efficiency >85%, THD <10% as per IEC 61000-3-2, P.F ≥0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type II/III as per the width of the road and the project requirement, suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000K / 4000K / 5700K / 6500K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect of external connections with 1.5 sq.mm FRLS/HRFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. Thermal management heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C.
(A)100 Watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt) as required.) | 50 | Nos. | 3,374 | ₹1,68,700 |
| 1.02 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 Hz. Operating temp range -5°C to 50°C, internal surge protection of 5 KV L-N, E as per IEC 61000-4-5, Driver efficiency >85%, THD <10% as per IEC 61000-3-2, P.F ≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30°–120° as per the application and the project requirement, suitable fit able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000K / 4000K / 5700K / 6500K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect of external connections with 1.5 sq.mm FRLS/HRFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty, System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-In-Charge as per requirement. Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C.
(A) 250 watt LED Flood light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) as required. | 30 | Nos. | 6,229 | ₹1,86,870 |
| 2Total impact of GST for the purpose of CTC | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_367614.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.88 MB
Tendernotice_2.pdf
PDF • 1.16 MB
BOQ_367614.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .