Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 LAccepted-AOC VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | L1 | Accepted-AOC L1 Bidder with reasonable quoted amount | |
| 2 | L2₹49.6 L+₹5.1 L (11.4%)Rejected-Finance A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹53.3 L+₹8.8 L (19.8%)Rejected-Finance JYOTISH ROAD TEZPUR DISTT SONITPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹53.9 L+₹9.4 L (21.2%)Rejected-Finance AIR FORCE ROAD GOROIMARI PO HALESWAR TEZPUR DISTT SONITPUR PIN 784104 ASSAM | SONITPUR | ASSAM | 784104 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹54.0 L+₹9.6 L (21.5%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
23 Apr 2022, 6:00 pmClosed
GE(AF) TEZPUR
GE(AF) TEZPUR POST-SALONIBARI DIST- SONITPUR ASSAM-784104
REPAIR AND MAINT OF CRANE , LIFT, VOLTAGE STABILIZER, FIRE HYDRANT, AMC OF FIRE ALARM AND OTHER CONNECTED MISC WORKS AT AFS TEZPUR UNDER GE (AF) TEZPUR
2022_MES_516653_1
GE(AF)/TEZ//8648/2022-23
Open Tender
Civil Works
Item Rate
180 days
AFS TEZPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) TEZPUR
₹90,000
Yes
26 Jul 2022
5 Apr 2022
25 Apr 2022
5 Apr 2022
23 Apr 2022
18 Apr 2022
Amount
M & L for perodic inspection/ servicing/Load testing of 02Ton capacity EOT crane of any make installed at different building/location at site, making the cranes in serviceable condition complete all as specified and directed with and including opeartions for maintenance specified as under:- (A) LONG TRAVERSE MOTION / CROSS TRAVERS MOTION / HOIST MOTION- (a) Checking gear box oil level, checking and rectifiaction of leakage if any and filling with new oil up to required level. (b) Checking functioning of all brakes of any capacity and making adjustment for proper working. (c) Checking motion wheel for any abnormal sound & checking mounting/ fixing arrangement. (d) Checking of grease in geared coupling and tighting of nut/bolts etc. (e) Checking of motion cut off at extreme ends with limit switches. (f) Checking drive shaft and coupling including tighting of nut and bolts. (g) Checking oil in FLP thrustors checking any leakage any filling with new oil. (h) Checking terminal connection of all LT motion of three phase FLP electric motor and tightening properly including repalcing burnt out/ over heated cable ends if any. (B) ELECTRICALS (a) Checking and tightening all electric connection (b) Checking the contactors/ relays etc for overheating or flashinng. (c)Clening off all connection and control cables. (d) Properly bunching the loose control cable. (e) Checking functioning of cable carriers. (f) Checking the connection and serviceability of VVVF drives for smooth working. (E) GROUND MOTION CONTROL PANEL Opening the push button control unit, checking all connection, replacing flashed/ over heated connections, general cleaning and checking all the functions,of the LT/CT/ Hoist motion push buttons and lights/ VVVF switch including reassembling the unit complete LOAD TESTSTING:- Load testing complete for LT/CT/Hoist motion of the 2 ton EOT cranes(installed at eleven different location with in TA complex) for 125% capacity using any type of dead weight ,complete all as specified and as directed Note-1 Necessary weights shall be arranged by the MES Department . 2 Shifting of load at site and shifting to different buildings/locations with in TP complex using truck/mobile crane etc of suitable capacity shall be arranged by the contractor . 3 Tools, tackles ,chains and sling etc of suitable capacity required for load testing shall be arranged by the contractor. 4 Unit rate quoted shall be deemed to incl the cost of all above and no extra payment on this acount shall be made . Adjustment of brakes, motors,gear boxes, electrical system, load hook ,steel wire ropes , limit switches and all related item complete all specified and directed.
All as per Srl No 1.00 here-in-before but for of 5 Ton capacity EOT Cranes.
All as per Srl No 1.00 here-in-before but for of 10 Ton capacity EOT Cranes
All as per Srl No 1.00 here-in-before but for of 10 Ton capacity flame proof EOT Cranes.
All as per Srl No 1.00 here-in-before but for of 2 Ton capacity Manually operated Overhaed traveller Cranes.
Supply fixing and making all connection ,limit switch capacity 40 Amp 415 Volts all as per existing for LT/CT/ Hoist motion of 10 ton capacity EOT crane including taking down old unserviceable complete all as specified and as directed.
Supply fixing and making all connection ,limit switch capacity 40 Amp 415 Volts all as per existing for LT/CT/ Hoist motion of 10 ton capacity FLP EOT crane including taking down old unserviceable complete all as specified and as directed.
S&F flame proof thrustor unit complete as per existing capacity 18 Kg incl taking down the old unserviceable all as specified and as directed.
Supply only gear oil grade 680 (Heavy Duty Industrial Oil) suitable for reduction gear boxes Note :-For item no 1 to 5
S&F brake liner set suitable for 100 mm dia drum for LT/CT motion of 10 Ton capacity FLP crane complete all as directed and specified
All as per item No 10 here-in-before but 160 mm dia drum complete all as specified and as directed
Supply and fixing brake liner set suitable for 150 mm dia drum for hoist motion of 10 Ton capacity FLP crane complete incl taking down old unserviceable complete all as directed and specified
All as per item no 12 her in before but 200 mm dia drum complete all as specified and as directed
Supply and fixing torque spring suitable for 6 Kg capacity 100 mm dia drum brakes of LT/CT motion incl taking out the old unserviceable complete all as specified and as directed.
All as per item no 14 here-in-before but 9 Kg capacity and 160 mm dia drum for LT/CT/hoist motion complete all as specified and as directed.
All as per item no 14 here-in-before but 20 Kg capacity and 200 mm dia drum for hoist motion complete all as specified and as directed.
S&F air break contactor 12 amps coil voltage 110 volts 50 Hz complete incl taking out the old unserviceable complete all as specified and as directed. Make ABB/L&T/Seimens
All as per item No 17 here-in-before but 32 amps complete all as specifed and directed
All as per item No 17 here-in-before but 12 Amp Aux contactor complete all as specified and directed
All as per item No 17 here-in-before but 25 Amp Aux contactor complete all as specified and directed
All as per item No 17 here-in-before but 32 Amp Aux contactor complete all as specified and directed
M&L for MS coupling 25 mm dia with nuts ,bolts and bushes suitable for LT/CT motors incl taking out the old unserviceable all as directed.
All as per item No 22 here-in-before but 50mm dia for drive shafts complete all as specified and as directed
M&L for Rewinding of Hoisting Motor 10 HP by supper enamelled Copper winding wire of same gauge as existing one including heating, Varnishing and testing after completion all as directed by Engr-in-Charge.
All as per item No 24 here-in-before but 7.5 HP complete all asspecified and as directed
M & L for Serviceing and repairing of Oil Cooled Servo Voltage Stabilizer , by disconnecting of all incomming and out going cable , opening of top cover carefully, cleaning of motor , service connection ,gear pininon and replacement of minor spares such as fuse, diode, carbon brushs, holder, internal electrical wiring and electronic accessories and insulated properly by varnishing, greasing, CRC spraying, electrical connections, filtration of transformer oil, making electrical connection by replacing the consumable spares such as gaskets, rubber oil seals complete etc but other spares as listed here-in-after shall be replaced and cost of spare parts as supply only shall be measured and paid separately under relevent item after that testing of servo voltage stabilizer in presence of Engr-in-charge , complete all as specified and directed by Engr-in-Charge capacity servo voltage stabilizer 75 KVA thre phase.
All as per serial item no 26 here-in-before capacity 200/250 KVA 3 Phase
All as per serial item no 26 here-in-before capacity 500 KVA /630 KVA 3 Phase Note for serial item no 26 to 28:- (i) Spare parts required to make serviceable of above oil cooled servo voltage stabilizer shall be measured and paid separately under relevent item here-in-after. (ii) Rewinding of barrier assembly and transformer assembly will be measured and paid separately.
Supply only Potentiometer.Make Volina/Hindustan/AE
Supply only Voltmeter (Digita). Make MECO, Havells,L&T,HPL/Crompton/AE
Ampere Meter with (Digital) Make MECO, Havells,L&T,HPL/Crompton/AE
Supply only P C B Holder.Make Volina/Hindustan/Servocon
Supply only Servo Motor 10 Kg Torque.Make Volina/Hindustan/Servocon
Supply only Servo Motor 20 Kg Torque.Make Volina/Hindustan/Servocon
Supply only Carbon Brush (20amps to 200 amps) Make Volina/Hindustan/Servocon
Supply only Carbon Holder & Spring.Make Volina/Hindustan/Servocon
Supply only Servo motor gear pinion.Make Volina/Hindustan/Servocon
Supply only R C Net work for 10 Kg Motor.Make Volina/Hindustan/Servocon
Supply only R C Net work for 20 Kg Motor.Make Volina/Hindustan/Servocon
Supply only Drive assembly 75 Kva per phase.Make Volina/Hindustan/Servocon
Supply only Drive assembly 200/250 KVA per phase.Make Volina/Hindustan/Servocon
Supply only Digital Control Panel with Circuit board for high / low Voltage cut per phase suitable for 3 phase Voltage Stabilizer of capacity upto 75/200/250/500/ 630KVA.
Supply only front control with wiring kit .Make Volina/Hindustan/Servocon
M&L rewinding of Dimmer Starter (Barrier) for 75 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Complete all as specified and as directed
M&L rewinding of Dimmer Starter (Barrier) for 200/250 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Complete all as specified and as directed
M&L rewinding of Dimmer Starter (Barrier) for 500/630 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Complete all as specified and as directed
M&L Rewinding of Transformer assembly for 75 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Make Volina/Hindustan/Servocon
M&L Rewinding of Transformer assembly for 200/250 KVA 3 Phase Servo-Stabilizer with Super Enamel Copper Wire of existing gauge.Make Volina/Hindustan/Servocon
M&L for Comprehensive maintenance of Fire fighting DG Pump, Electric Pump, Jockey Pump set of different capacity, consisting of Checking, Inspection, Maintenance, and servicing complete including replacement of unserviceable parts of the DG Pump, Engine Oil, Coolent, fan belt, fuel filter, oil filter etc. Attending breakdown and testing of Pump complete, i.e, engine, Radiator, Self, FIP etc for efficient functioning including provision of all consumables items like cotton, waste cloth, kerosine oil etc. including cleaning of radiator & other related equipments of the pump house / installations alongwith valves including cleaning of inside and outside areas of the respective fire fighting pump houses, wash out of inlet & outlet pipe, repairing of NRV, replacement of gland packing, coupling maintenance of suction and delivery pipe lines, primary fill up of priming tanks at different locations including testing on completion, complete all as specified and directed by Engr-in-Charge. Note: (i) Rate of Engine oil, coolant and distilled water will be paid seprately. However rates for all kind of filter and servicing charge of DG is deemed to be included in the quoted rate. (II) Labour charges for dismantling / Taking down and replacement /refixing of new spare parts as when required as deemed to be included in unit rate quoted.
Supply and filling of engine oil 20W/40 multi grade, to top up / refilling of all DG set of various capacity, model & location here-in-before as per the direction of engr-in-charge. (Make : GULF/SERVO/VALVOLENE)
Supply and pouring of anti corrosive/antifreeze coolent suitable for radiator for Kirloskar/Cummins make engine as per the requirement as directed by Engr-in-charge for various capacities of DG Set (Make : SERVO KOOL/CASTROL/PUROKOOL/K-KOOL)
Supply and pouring distilled water for battary and radiator as directed.
M&L for calibration of fuel injection pump including minor spares and repair and servicing of injector nozzeles of Fire DG Pump complete all as specified and directed.
Supply only hose pipe sets for fire fighting DG Pump, complete all as specified and directed.
Disconnecting the self starter (12V) from the engine body, dismantling the same, checking for identification of faulty spares and reassemblig the same after replacement/renewal of the following spares, if required, including refixing to its original position all as specified and directed Note :- spares, required to be replaced, shall be measured and paid under respective items mentioned here in under.
S&F fixing in repair against the faulty clutch assembly for the self starter(12V) (Make : LUCAS / TVS)
Supply and fixing in repair against the faulty Bendex pinion for the self starter(12V) (Make : LUCAS / TVS)
Supply and fixing in repair against the faulty Solenoid switch for the self starter(12V) (Make : LUCAS / TVS)
Supply and fixing in repair against the faulty Carbon Brush for the self starter(12V) (Make : LUCAS / TVS)
Supply and fixing in repair against the faulty Armature Field Coil for the self starter(12V) (Make : LUCAS / TVS)
Supply and fixing in repair against faulty Bush for the self starter(12V) (Make : LUCAS / TVS)
Supply and fixing in repair against faulty armature coil for the self starter(12V) (Make : LUCAS / TVS)
Supply, installation and testing of lead acid battery of capacity 12 volts, 150 AH with one set of heavy duty battery terminals for connection all complete all as per specified and directed. (old unsv Battery to be deposited to be MES store Yard).
Supply, installation and testing of lead acid battery of capacity 12 volts, 100 AH with one set of heavy duty battery terminals for connection all complete all as per specified and directed. (old unsv Battery to be deposited to be MES store Yard).
M&L for repair and maint of star delta Starter of any capacity after disconnecting of incoming / outgoing connection, checking the serviceability of all components i.e existing contactors, Over load relay, timer, single phase preventer, indicator lights, replacement of burnt out PVC insulated copper wire, copper thimble, re-connect the same after throughly clean and testing all as required and directed at site. (NOTE : Spare parts shall be measured and paid separately under respective items of this schedule.)
Replacement of contactor of capacity 12 Amp, 3 Pole, 415 Volt, AC rating 3, Type MNX 12 including auxiliary contact block NO & NC. (Make : L&T/C&S)
Replacement of contactor of capacity 25 Amp, 3 Pole, 415 Volt, AC rating 3, Type MNX 25 including auxiliary contact block NO & NC. (Make : L&T/C&S)
Replacement of contactor of capacity 32 Amp, 3 Pole, 415 Volt, AC rating 3, Type MNX 32 including auxiliary contact block NO & NC. (Make : L&T/C&S)
Replacement of thermal overload relay of range 24-40A. (Make: L&T/C&S/Havells)
Replacement of star delta timer adjustable type from 3 to 30 sec.
Replacement of single phase preventer, SPPR type SDz5, 380V, (For MU-G30/40/50/75)
Material and labour for attending break down of pipe line bursting/cracks including cleaning/removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and providing transport to work site for material and tools and inserting necessary specials such as pipes, CI Collar / mechanical Joints etc as required at site under relevent items, including testing for leakages of lead joints and necessary dewatering up to completion of the job work at site all as specified and directed for the 100mm/150mm dia of CI/DI/MS Pipe. (P.C.C. work will be measured and paid separately under relevent item) Note: Rates quoted deemed to inclusive of the following: (i) Excavation and cutting of Hard Standing. (i) arrangement of suitable Pump set for dewatering at the time of attending break down (ii) Labour/Trade men for attending break downs (iii) transport to shift the material and tools (iv) levelling/ allighnment to both sides pipe for jointing (v) Arrest/rectification of leakages if any whileTesting if any, immediately to restore.
Supplying, Laying, Testing and Commissioning of 150 mm dia (NB) ISI marked heavy class M.S. pipes including cutting, screwing, welding etc. and providing all fittings such as elbows, reducers, flanges, gaskets, nuts, bolts and washers etc. providing adequate support to the pipe and making good the same complete as required. Rate shall include for dewatering necessary to execute the work. Protection to embedded MS pipes and fittings by applying pyp kote primer (@ 100 gm/sqm) thereafter wrapping 4 mm thick pyp kote (AW 4 mm) protection coating by thermo fusion process. Overlap shall be maintained at 15 mm. The application process shall be strictly according to manufacturer’s specification.
All as per Srl No 67 here-in-before but for of 100 mm dia ERW MS Pipe.
M & L for Making good surface where cutting / Excavated Road/hard standing/path by making cement concrete filling with mass concrete of 1 : 3 : 6 type C1 with 20 mm graded aggregate complete all as specified.
Supply and fix 150mm bore hand operated butterfly valve of pressure not less than 15 Kg/Sq cm with complete set.
Supplying and fix valve, butterfly conforming to IS 13095, 65 mm (2.5") dia.
S&F in repair Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white insideyard, complete all as specified and directed.
Supply and Fix in repair 63 mm dia 15 mtr long Hose conforming to IS 636 complete with male and female coupling conforming to IS: 903, complete all as specified and directed.
S&F in repair Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short, complete all as specified and directed.
Supply, Installation, Testing and commissioning of GM foot valve of size 150 mm bore, conforming to relevent IS 4038 specifications complete as specified.
Comprenesive maintenance, rapair and upgradation of software including renewal/replacement of defective parts of all existing fire detection system complete consisting of addressable fire control panel, Remote Terminal Unit panels, smoke/heat detector, response indicator, sounder, Manual call Point, Amlifier, Loud speaker, Loop isolator, Zone monitor module, Modem etc. to make 100 % serviceability of the complete incl checking of fire detector, cleaning of heavy greasy deposit if any, checking the connection of batteries, the alarm function of control and indicating eqpt be checked by the operation of trigger device in each zone as described, the system installed in Fire station every month during first or last week as directed by engineer-in-charge Note:- (i) Cost of new components shall be paid for separately under relevant items of schedule 'A" (ii) Contractor's rep will visit minimum once in a month to every panel and take serviceability certificate duly signed by the user. Note : "Repair and maintenance of Fire Alarm system should be done through OEM or through the authorized service provider of the OEM or any other agency dealing with the installation and maintenance of FIRE ALARM REMOTE COMMUNICATION SYSTEMS (RTU) and has vast experience in the relevant field as approved by the next higher authority to the Accepting Officer".
Dismantling ,servicing of all multisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturer's instructions and testing for exact fault locations including cleaning through air blower then reinstalling complete all as specified and directed.
Supply only of 12 V, 12 AH battery for back up to all FACP panel. Make: Exide/Amar Raja
Supply only of 12 V, 7 AH battery for back up to all FACP panel. Make: Exide/Amar Raja
Supply and fixing in repair combined scattered light smoke and temperature multisensor detector programmed to detect either smoke or heat, or both depending on the type of system having sensitivity in accordance with existing fire alarm system of including taking down existing unservicable detectors complete all as specified and directed by the Engineer-in-Charge.
Supply install testing in repair Indoor type detectors complying with and type certified to EN-54 Addressable type flame detector with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module) all as specified and as directed.
Supply and fixing in repair of electronically addressable intelligent resettable type Manual Call Point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below complete all as specified and directed by the Engineer-in-Charge. :- a)Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current) b) Class A c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key. d) Ingress Protection IP-24 & Material-ABS for existing L & T Electrical & Automation(schrack-seconet) fire alarm system.
Supply and fixing in repair of fire alarm sounder/sirens electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 m with sound output variation of + 5db 1500 m range for fire alarm system complete all as specified and directed by the Engineer-in-Charge.
M & L for Periodical Overhauling and greasing/ Oiling of Entire Lift including Hoist Way Material, Guide Rails, Car Counter, Weight, Pulleys, Gear Box,and changing of gear oil etc as on when required complete all as specefied and as directed by Engineer-in-Charge. Note : (a) Major Spare Parts will be Measured and paid separately under relevant items. (b) Contractor's rep will visit minimum once in a month to every lift and take serviceability certificate duly signed by the user. Note : "Repair and maintenance of Lift should be done through OEM or through the authorized service provider of the OEM or any other agency dealing with the installation and maintenance of Lift and has vast experience in the relevant field.
Supply and Fixing of Mother Board in elevator for Bed Cum Passenger Lift .
Supply and Fixing of Power Supply Card 220 V in elevator for Bed Cum Passenger Lift .
Supply and Fixing of Transformer 220V/9V in elevator for Bed Cum Passenger Lift .
Supply and Fixing of Transformer 440V/135V in elevator for Bed Cum Passenger Lift .
Supply and Fixing of Power Supply Card 110V in elevator for Bed Cum Passenger Lift .
Supply and Fixing of UP/DN & IL Relay Card in elevator for Bed Cum Passenger Lift .
Supply and Fixing of Car Operative Button Set with all accessories (For Lift car & Floor button) in elevator for Bed Cum Passenger Lift .
Supply and Fixing of Landing Push button Set in elevator for Bed Cum Passenger Lift .
Supply and Fixing of Gate Relay assembly set in elevator for Bed Cum Passenger Lift .
S&F Elevator door detector (Infrared sensor) of capacity 188/988 A-AC 220 Volt in both side of door with one No power controller of capacity DC24 VIA or AC 120 VIA fix in existing position including taking down old unserviceable door detector.
Replacement of Car Gate Contact Lock for Lift as per existing specification and fixed including Taking down old Unserviceable Car Gate Contact Lock, complete all as specified and as directed.
Supply and fix, installation testing and commissioning Encoder/Main drive including taking down of old unsv encoder unit complete all as specified and as directed by Engr-In-Charge.
Supply and fix in replacement ARD Card including taking down complete with testing and commissioning complete all as specified and as directed by Engr-In-Charge.
Supply & fixing in replacement of Battery 12 Volt 18 AH for existing ARD of lift at OT complete all as specefied and as directed by Engr-in-charge. (Make : EXIDE/ AMARON.
Supply and fix in replacement Safety circuit with complete accessories/unit including taking down complete with testing and commissioning complete all as specified and as directed by Engr-In-Charge.
kabitaconstruction
SHRI D. C. BISWAS
M/S Annu Electronics
M/S BARUA REFRIGERATION WORKS
KAILSON
M/S Kangkans
M/S R.B. Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .