Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC 204B SENTHAMANGALAM GOTHANDARAMPURAM VILLAGE PERUMANADU POST VAYALOGAM VIA PUDUKKOTTAI DIST TN | PUDUKKOTTAI | TAMIL NADU | 622104 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹28.6 L+₹66,451 (2.38%)Rejected-Finance | L2 | Rejected-Finance Not being the lowest tendereer |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
4 Dec 2023, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
ADDITIONAL ALTERATION TO INCREASE HEIGHT OF EXISTING SECURITY WALL FROM OFFICERS MD ACCN TO NCC OFFRS MESS AND SPECIAL REPAIRS TO WATER SUPPLY DISTRIBUTION NETWORK AND INTERNAL WIRING INCLUDING CERTAIN REVENUE AND MINOR WORK AT DET TRICHY UNDER GE W
2023_MES_626681_1
8844/E8
Open Tender
Civil Works
Item Rate
120 days
TRICHY
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹61,000
Yes
2 Mar 2024
3 Nov 2023
11 Dec 2023
4 Nov 2023
4 Dec 2023
15 Nov 2023
Amount
Demolition of Brickwork, stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4, using 20mm graded stone aggregate as in beams, cantilevers, shelves, bressummers, lintels over 1.5m span complete all as specified and directed.
Use and waste of formwork to sides of rough finished concrete foundations, footings, base of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter flat surface complete all as specified and directed.
Mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
All as per item No. 4 hereinbefore but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Pre-cast cement concrete block masnory with solid block exceeding 10cm in width and setting in mortar 1:6 type C1 1:3:6 using 20mm graded stone aggregate complete all as specified and directed
Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43litre/10Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10Sqm over new surfaces complete all as specified and directed.
Providing plain cement concrete type B1 1:2:4 using 20mm graded stone aggregate as in benching / copings including necessary formwork all as specified and directed.
Dismantling of Wrought iron or Mild steel work of any description not otherwise provided for such as fencing posts, gates, etc complete all as specified and directed.
Fixing only Mild steel Framed work such as grill, grating etc with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars, barred iron door, ladders, framed balusters, walk ways, railings, framework of water tanks all as specified and directed. Note: The item dismantled shall be refixed.
Mild steel Framed work such as grill, grating etc with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars, barred iron door, ladders, framed balusters, walk ways, railings, frame work of water tank and simialr work conforming to Fe410-0 or Fe310-0 all as specified and directed.
Preparation of old steel surfaces over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.50M in depth; for foundation, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundations filling and mass concrete all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4 using 20 mm graded stone aggregate as in foundations, including rafts, footing, foundations, beams, plinth beams, bases for columns, etc., basement slabs, under reamed piles and mass concrete etc complete all as specified and directed.
Reinforced cement concrete (nominal mix) Type B1, 1:2:4, using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surface of concrete complete all as specified and directed.
Use and waste of steel Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. Fair finished surfaces of concrete flat complete all as speicified and directed.
Preparation of new plastered wall surface and applying two coat of cement base paint over a coat of primer on wall surfaces complete all as specified and directed .
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in soft / loose soil complete all as specified and directed
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Preparation of new or untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard dense soil all as specified and directed.
Hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed.
50 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base and finished even and fair complete all as specified and directed.
60mm thick factory made chambered edge cement concrete paver block of M-35 grade with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness an size / shape, made by table vibratory method using PU mould laid in required colour and pattern over and including 50mm thick compact bed of fine sand, compacting and proper embedding laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of pavwer blocks as per required size and pattern, finishing and sweeping extra sand all as specified and directed.
Providing precast cement concrete type B1, 1:2:4 using 20mm graded aggregate in cement mortar as in kerbs other than roof kerbs all as specified and directed.
Taking out / up / down from trenches /walls /floors of galvanised steel tubings and connections of bore of pipe 40mm/ 50mm dia complete all as specified and as directed.
Taking out / up / down from trenches /walls /floors of galvanised steel tubings and connections of bore of pipe 80mm dia complete all as specified and as directed.
3 Layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion elded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings laid in trenches of having 63mm outer diameter of pipe all as specified and directed. Note: Wall thickness of pipes shall be all as per I.S. 15801
3 Layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion elded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings laid in trenches of having 90mm outer diameter of pipe all as specified and directed. Note: Wall thickness of pipes shall be all as per I.S. 15801
PPR gate valves (Brass Inset) of outer diameter of 63mm as per requirement of the site including taking down old unserviceable gate valve of any type and make and keeping aside for safe custody to issue under Schedule of credit all as specified and directed.
Non Return valves (Brass Inset) of nominal dia 50mm and outer diameter of 63mm as per requirement of the site including taking down old unserviceable gate valve of any type and make and keeping aside for safe custody to issue under Schedule of credit all as specified and directed.
Cast iron sluice valve class PN10 both and flanged, suitable for 80mm bore confirming to IS-14846 (2000) duly ISI marked with wheel operated handle with high tensile stainless steel spindle, including nuts, bolts, washers, flanges etc of requried size including making arrangement of safe working including taking down old unserviceable gate valve of any type, make and keeping aside for safe custody to issue under schedule of credit complete all as speciifed and directed.
Supply, lay connect and testing of galvanised iron tubes (GI), medium grade of 80mm dia with screwed socket joint, together with all tube fittings (such as bends, tees, unions, elbows, connecting pieces etc) and laying in trench/ fixing on wall with standard fittings for GI pipe complete with clips, wall hooks, wooden plugs or laying in trenches complete all as speciifed and directed. Note: (i) Earth work excavation, RFR and removal of soil shall be measured and paid separately under respective items. (ii) Make good of disturbed wall with necessary PCC and painting to existing colour is deemed to be included in the quoted rate.
Depositig bulk amount to trichy city corporation complete authority for cutting of bituminous surface road for laying of MS / RCC hume pipe not less than 150mm diameter and passing PP-R pipe of outer diameter of 90mm through the MS/ RCC hume pipe and making good at their end for their satisfaction all as specified and directed.
Taking down old/ unserviceable / damaged point wiring carefully of any type (i.e on wooden batten, surface conduit, casing and capping or concealed conduit) complete for light, fan socket or power point with fittings and fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, conduit etc. inlcuding accessories such as wooden gutties / rawal plug, screw etc including making good disturbed surface to match the existing surface all as specified and directed.
Taking down main switches, distribution board, steel encloser with MCB's any way and rating including wooden board or from steel board and making good distrurbed surfaces all as specified and directed.
Point wiring using approved colour coding as per IS (Red, Black and green for single phase circuits), with multistranded copper conductor 1.5 sq mm nominal cross-sectional area single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC conduit and accessories on wall/roof/floor etc, for concealed conduit wiring, ISI marked with mild steel/pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally, covered with modular inner and outer plates for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly One light/ fan/ Exhaust fan point controlled by one switch 5 Amp one way complete all as specified and directed.
All as per item No 40 hereinbefore but socket outlet 3 pin 5 Amps same board all as specified and directed.
All as per item No 40 hereinbefore but socket outlet 3 pin 5 Amps independent board all as specified and directed.
All as per item No 40 hereinbefore but for one socket outlet 15 Amps fixed on independent board with 4 Sqmm multistranded copper conductor wire FRLS PVC insulated and 2.5 Sqmm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed.
Wiring for circuit / sub main wiring using FRLS PVC insulated copper conductor cable of size 2x6mm along with 1 x 6mm single core cable for earth continuity to be drawn in non metallic PVC conduit in surface/ recessed all as specified and directed. Note: Two runs of PVC insulated cable with one run of earth wire and one run of conduit including accessories shall be measured as one length.
Ceiling rose, 2 to 3 terminals polycarbonate, isolated body complete all as specified and directed
Supply and fix MCB DB SPN 12 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed.
MCB DB SPN 4 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar single Phase including necessary dummy plate and necessary civil works all as specified and directed.
MCB's single pole 5 to 40 Amps, 240 Volts all as specified and directed.
MCB's SPN 240 Volts of capacity 6-40 Amps complete all as specified and directed.
LED tube light fittings 4 feet with fixtures 20 watts 230v 50HZ including connecting up with PVC two core copper conductor cable from ceiling rose to fittings complete all as specified and directed.
Lamp holder PVC/ Polycarbonate type including LED lamp 9 watt all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical platee No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover 1:2:4 B1 50mm thick with 8 mm dia MS bars at 100 c/c, funnel, watering pipe etc. all as specified and directed including testing on completion.
Taking out unserviceable switch in lieu of supply and fix switch pino type single pole one way 5 Amp 240V, 50Hz AC, ISI marked all as specified and directed.
Taking out unserviceable socket in lieu of supply and fix sockets outlet (Multi purpose) 2 in 1, 3 Pin, 5 Amps and 15 Amps flush type 230V, 50Hz AC, marked all as specified and directed.
Taking out unserviceable fan regulator in lie of supply and fix regulator stepped electronic fan regulator flush type (switch type) suitable for ceiling fan 240V AC 50Hz ISI marked all as specified and directed.
Supply and replacement of switch socket combination multi purpose 2 in 1, 3 pin, 5 Amps 230V, 50Hz AC, ISI marked all as specified and directed.
Supply and replacement of switch socket combination multi purpose 2 in 1, 3 pin, 5 Amps and 15 Amps flush type 230V, 50Hz AC, ISI marked all as specified and directed.
Reliance Sales Agency
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .