Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹18.2 L+₹5.1 L (38.6%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹19.3 L+₹6.2 L (47.0%)Rejected-Finance D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹20.9 L+₹7.7 L (59.0%)Rejected-Finance D NO 71 31 96 6 ASRR COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹22.4 L+₹9.3 L (70.8%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L5 | Rejected-Finance Not lowest |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
28 Jul 2022, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
REPAIR/ MAINT OF SEWAGE TREATMENT PLANT AND ITS ALLIED SERVICES INCLUDING DOZING PLANT, SWIMMING POOL INCLUDING CHLORINATION PLANT LOCATED IN SSTF COMPLEX AT INS KALINGA VISAKHAPATNAM UNDER GE(P) NAVY KALINGA
2022_MES_534939_1
GE (P)/N/K/8930 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class E, Cat a(ii)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹48,000
Yes
11 Aug 2022
30 Jun 2022
30 Jul 2022
30 Jun 2022
28 Jul 2022
14 Jul 2022
Amount
M&L Cleaning of 100 KLD RCC semi underground aeration tank size 3m x 3m x 2m along with fine bar screen chamber, grit chamber and connected system by blocking the inlet / outlet flow from manholes, lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc., scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc. from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, opening the blocked manholes etc. before normalising flow of sewer complete all as directed by the Engineer-in Charge.
M&L Cleaning of 100 KLD RCC underground of diameter 4 mtr and Depth 2.1 mtr along with connected system by blocking the inlet / outlet flow lines, lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, opening the blocked manholes etc before normalising flow of sewer complete all as directed by the Engineer-in Charge.
M&L Cleaning of 100 KLD RCC sludge drying beds having 4 Nos bed of size 5mtr x 1.5mtr x 1mtr along with connected system by blocking the inlet / outlet flow lines, lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, opening the blocked manholes etc before normalising flow of sewer complete all as directed by the Engineer-in Charge.
M&L Cleaning of 100 KLD RCC construction equalization tank of size 5.0m x 4.0m x 2.0m (Inner dimension) along with fine bar screen chamber, grit chamber and connected system by blocking the inlet / outlet flow from manholes, lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, opening the blocked manholes etc before normalising flow of sewer complete all as directed by the Engineer-in Charge.
M&L Cleaning of 100 KLD RCC construction FMR (fluidised media reactor) with tube setter / lamella setter tank ( MBBR and tertiary system) of size 10.5m x 3.2m x 3.0m (Inner dimension) and lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, opening the blocked manholes etc before normalising flow of sewer complete all as directed by the Engineer-in Charge.
M&L Cleaning of 100 KLD RCC construction treated tank of size 8.0m x 5.0m x 2.0m (Inner dimension) along with fine bar screen chamber, grit chamber and connected system lifting the excess semi-solid impurities in water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, opening the blocked manholes etc before normalising flow of treated water complete all as directed by the Engineer-in Charge.
S&F in repairs MCB TPN 'C' series, 32 Amps, including taking down existing unserviceable MCB complete all as specified and directed.
S&F in repairs MCCB 4 pole, 415 volts, adjustable type, 250 Amps with breaking capacity 35 KA, front operated with extension rod fixing on existing LT panel board, including taking down existing MCCB complete all as specified and directed.
S&F in repairs submersible pump DOL starter in sheet enclosure type MU-G6, 415 volts, 3 phase, 3 HP and relay ranging from 9 Amp to 14 Amp complete with single phase preventer including taking down existing starter complete all as specified and directed.
S&F in repairs submersible pump DOL starter in sheet enclosure type MU-G6, 415 volts, 3 phase, 5 HP and relay ranging from 12 Amp to 16 Amp complete with single phase preventer including taking down existing starter complete all as specified and directed.
S&F in repairs FASD Submersible pump starter In sheet enclosure type MU-G15, 415 volts, 3 phase, 10 HP and relay ranging from 13 Amp to 22 Amp complete with single phase preventer including taking down existing starter complete all as specified and directed.
S&F in repairs DOL motor starter In sheet enclosure type MU-2P, 415 volts, 3 phase, 1 HP and relay ranging 9-14 Amp complete with single phase preventer including taking down existing starter complete all as specified and directed.
Disconnecting of electric connection, taking out slow speed centrifugal motor of 5 HP from sewage aerator, transporting to workshop rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the motor, transporting upto site, re-installation and testing of the assembly as directed including replacement of DE/NDE bearings - 02 Nos complete as directed by the Engineer-in-Charge. (Make of pump: Kirloskar)
Disconnecting of electric connection, taking out horizontal centrifugal type non clogging self priming pumps (Make - Kirloskar) of capacity 3 HP from sewage treatment plant transporting to workshop rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the motor, transporting upto site, re-installation and testing of the assembly as directed including replacement of DE/NDE bearings - 02 Nos complete as directed by the Engineer-in-Charge. (Make of pump: Kirloskar)
Servicing and lubrication of slow speed aeration mechanism fixed with surface 5 HP motor (55 to 70 RPM) Aerator motor's gear system with MS drift tube of vertically flange mounted planetary geared motor of ratio (24:1) with 1450 RPM of motor speed and painting with two coat of synthetic enamel paint and topping of transformer oil complete all as specified and as directed by Engr-in-Charge.
Disconnect and remove existing primary / secondary clarifier mechanism along with related accessories from the position including drive unit from STP, transporting to workshop servicing the same and re-installation in same position after replacement of worn out following spares and painting with one coat of synthetic enameled paint including testing complete as directed by the Engineer-in-Charge. (Location: STP Plant) (i) 3.5 mtr long shaft - 1 No (ii) Oil Seal - 1 No (iii) Rubber coupling - 1 No
S&F Cast iron impeller, suitable for 5 HP capacity monoblock pump as in repair, complete all as directed by the Engineer-in-Charge. Make MBH Model No- MBHN-10 or equivalent as approved by GE
M&L mild steel screw bolts (machine made ) 11 mm to 15 mm diameter of neck and length of bolt exc 5 cm long with hexagonal or square heads at one end and screw the other, or screwed both ends, each scerwed end to be fitted with washers and one hexagonal or square nut, complete all asspecified and directed.
M&L preparing old steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed.
M&L complete removal of old paint on panel boards of any description, not other wise described, over 10 cm width or girth and aplying through spary painting two coats of synthetic enamel paint over a coat of primer, including preparation of surfaces complete all as specified and as directwed by the Engr-in - charge.
S&F in repair Motor protection relay thermal over range having range from 8 to 44 A, suitable for aux supply 240 Volt including taking downexisting relay complete all as specified and as directed.
Supply & Fixing in repair analog Ammeter 0-50 Amps 3 phase, AM50A, 415 volts, AC supply of size 96 mm x 96 mm, with current transformer of suitable ratio including taking down existing meter & CT ccomplete all as specified and directed by Engr-in-charge.
Supply & Fixing in repair analog Voltmeter 0-500 Volts 3 phase, VM 500 415 volts, AC supply of size 96 mm x 96 mm, including taking down existing meter complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair LED Indicating lamp RYB (Red, Yellow & blue set of three),415V complete all as specified and as directed by Engr-in-charge.
S&F in repair Electronic timer of type ST-100, suitable for 9- 30 seconds, 240V / 415 V including taking down existing timer complete all as specified and as directed.
S&F in repair current transformer of ratio 30/5 including taking down existing CTcomplete all as specified and as directed.
S&F in repair three pole power contactor of type MNX 40 suitable for 415 volts 63 amps, 3 way, 4 poles including taking down existing Contractor complete all as specified and as directed. Make- L&T Cat No : CS 94190 or equivalent as approved by GE
S&F in repair Rotary switch (ON-OFF), suitable for 415V 63 Amps, 3 way, 4 pole, as in repair complete all as specified and as directed.
Supply and fixing in repair of single phase preventer auto reset relay, 40 volts unbalance Make: Minilec Cat No VSP-3 or equivalent complete all as specified and directed by Engr-In-Charge.
Suply and lay 19 mm thick ISI Marked LT synthetic mat, size 2 metre x 1 metre, placed at electric installation as directed by Engineer -In - Charge.
M&L Complete removal of old paint on surfaces of motor pump set of capacity 1 HP and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (using spray gun) including preparation of surfaces for any description/type with marking of SM/MES No of pump sets complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 32 here- in - before but of capacity 3 HP
All as per item No 32 here- in - before but of capacity 5 HP
All as per item No 32 here- in - before but of capacity 7.5 HP
All as per item No 32 here- in - before but of capacity 10 HP
S&F in repairs SS impeller suitable for sewage pump sets non clogging type make Kirloskar capacity 20 HP including taking down existing impeller complete all as specified and as directed. Make of pump - Kirloskar
All as per item No 37 here- in - before but of capacity 10 HP
All as per item No 37 here- in - before but of capacity 7.5 HP
All as per item No 37 here- in - before but of capacity 5.0 HP
All as per item No 37 here- in - before but of capacity 3.0 HP
S&F in repair Mechanical lower and upper seal of capacity 3 HP sewage submersible pump sets non clog type and filling new cooling oil including taking down existing seal complete all as specified and as directed. Make - MBH Model No-MBHN-5-15 or equivalent as approved by GE
All as per item No 42 here- in - before but of capacity 5 HP
All as per item No 42 here- in - before but of capacity 7.5 HP
All as per item No 42 here- in - before but of capacity 10 HP
S&F in repairs Bearing including lubrication of all moving parts for submersible type sewage pump sets non clogging type of capacity 7.5 HP including taking down of existing bearing complete all as specified and as directed. Make of pump : Kirloskar
S&F in repairs Bearing including lubrication of all moving parts for submersible type sewage pump sets non clogging type of capacity 3 HP including taking down of existing bearing complete all as specified and as directed. Make of pump : Kirloskar
Testing of inlet and outlet sewage samples for all parameters as per Enivornmental Protection Act for effluent discharge into inlet surface water form Govt regconised or approved institute/test labs and submit the test report complete all as directed by Engr-in- Charge. (Note : Testing of one sample each for inlet and outlet shall be considered as one job. Testing shall be carried out once in a month at regular interval)
Repairs / Replacement of pressure filter media of filter bed having size 3 mtr dia, 1.5 mtr height as per the following :-
(a) Open the man hole and taking out carefully existing filter media of any size, stacking neatly after thorough cleaning and segregating the media of round pebbles and coarse gravels for reuse from vertical size pressure and Cleaning of internal walls of pressure filter with bleaching powder solution by using wire brush and applying two coats of synthetic bitumen paint complete all as specified and as directed by Engineer - in - Charge. Note : Filling/spreading only filter media will be measured and paid separately.
(b) Spreading only the filter media (Pebbles) obtained from item No:- 49.1(a) on the lower portion of the filter bed.
(c) Spreading only the filter media (Coarse gravels) obtained from Item No:-49.1(a)
(d) Supply and laying filter media pebbles naturally obtained from the river bed of size 5mm to 20 mm
(e) Supply and laying filter media coarse gravels of size 1.0 mm and fine gravel of size 0.5mm
(f) Supply and laying filter media 14/30 mesh sand (fine sand) in layers up to 600 mm thick
Material and labour for opening top cover of Activated Carbon filter and replacement of Actived Carbon 200 Kg and reassembling the top cover of Actived carbon filter without disturbance of system all as directed by Engineer- in-charge
S&F in repair Add on auxilary contactor block 2NO + 2NC including necessary elect connections including taking down existing contact block complete all as specified and as directed. Make : L&T Cat No CS94114 or equivalent as approved by GE
S&F in repair Add on auxilary contactor block 1NO + 1NC including necessary elect connections including taking down existing block complete all as specified and as directed. Make : L & T Cat No CS94118 or equivalent as approved by GE
Taking down Horizontol non-clogging type Mono block pump set of capacity 10 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installationc , new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking down Horizontol type pump motor set of capacity 7.5 HP from the base after disconnecting electric connection, cleaning, reassembling, re-installationc , new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking down vertical non-clogging type Mono Block pump set of capacity 5.0 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installationc , new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking down vertical non-clogging type monoblock pump set of capacity 3.0 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installationc , new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking down Horizontol non-clogging type Monoblock pump set of capacity 20 HP from sewage sump with connected pipes after disconnecting electric connection, cleaning, washing the complete pump set, transporting to workshop for repair including dismantling of the pump set, rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the pump set, refilling new cooling oil, transporting upto site, re-installation includingudung and testing of the pump set including replacement of the following worn out parts and testing of pump set complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos Make of sewage pump : Kirloskar,
Repair of non-clogging type Mono Block pump set of capacity 7.5 HP from sewage sump with connected pipes after disconnecting electric connection, cleaning, washing the complete pump set, transporting to workshop for repair including dismantling of the pump set, rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the pump set, refilling new cooling oil, transporting upto site, re-installation including and testing of the pump set including replacement of the following worn out parts and testing of pump set complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos Make of sewage pump : Kirloskar,
Repair of electric driven vertical non clogging type Monoblock pump set of capacity 5.0 HP from sewage sump with connected pipes, transporting to workshop for repair including serving of pump set and motor, re-winding of the motor with suitable gauge of super enamelled copper wire, varnishing, drying, heating including greasing, oiling reassembling, transporting upto site, re-installation and testing of the pump set including replacement of following worn-out parts as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos Make of sewage pump : Kirloskar
Repair of electric driven vertical non clogging type Monoblock pump set of capacity 3.0 HP from sewage sump with connected pipes, transporting to workshop for repair including serving of pump set and motor, re-winding of the motor with suitable gauge of super enamelled copper wire, varnishing, drying, heating including greasing, oiling reassembling, transporting upto site, re-installation and testing of the pump set including replacement of following worn-out parts as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos Make of sewage pump : Kirloskar
S &F in repair in repair 25 MM Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed by Engineer-in-charge
S &F in repair in repair 40 MM Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed by Engineer-in-charge.
S &F in repair in repair 50 MM Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed by Engineer-in-charge.
Taking up/down 80 mm bore CI water mains and connections/fittings of any type from trenches / walls / floors or any other location for replacement / reuse in old/new location / diversion by burning out / removing of lead joints/tyton joints / rubber gaskets joint complete all as specified and directed by Engr -in -charge.
Taking up/down 100 mm bore CI water mains and connections/fittings of any type from trenches / walls / floors or any other location for replacement / reuse in old/new location / diversion by burning out / removing of lead joints/tyton joints / rubber gaskets joint complete all as specified and directed by Engr -in -charge. Note for Item No 64 & 65 (a) Necessary earthwork if any will be measured and paid separately under relevant item. (b) Taking up valves of different types to be measured and paid separately under relevant item.
Supply, laying and testing 80 mm bore cast iron pipes, with spigot and socket ends, centrifugally cast of class 'A' in any length, laid in trenches complete all as specified and as directed.
Supply, laying and testing 100 mm bore cast iron pipes, with spigot and socket ends, centrifugally cast of class 'A' in any length, laid in trenches complete all as specified and as directed.
S&F fittings cost iron Bends upto 150 mm bore (any type radius angle)Tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and as directed.
S&F in repair 100 mm bore CI butterfly valve, BS 5155, Gear operated with necessary rubber gaskets, nuts and bolts and washers of suitable size including taking down existing valve complete all as specified and as directed.
S&F in repair 80 mm bore CI butterfly valve, BS 5155, lever operated with necessary rubber gaskets, nuts and bolts and washers of suitable size including taking down existing valve complete all as specified and as directed.
S&F in repair 80 mm bore Cast Iron sluice valve of class PN-1.6 long body type, heavy duty ISI marked flanged (IS-1538) flanged ends with iron wheel and brass spindle including rubber gasket joints, nut, bolts etc including taking down existing valve complete all as specified and as directed.
S&F in repair 100 mm bore Cast Iron sluice valve of class PN-1.6 long body type, heavy duty ISI marked flanged (IS-1538) flanged ends with iron wheel and brass spindle including rubber gasket joints, nut, bolts etc including taking down existing valve complete all as specified and as directed.
S&F in repair MCB TPN 63 Amps 'C' series inductive load with surge current including taking down existing unserviceable BCM complete all as specified and as directed. Make - C&S Cat No- CSMBS3C63N or equivalent as approved by GE
Supply only Chlorine gas for gravity type Gas Chlorinator Note:- Care must be taken to ensure that they are handled and used in a safe handled and leakage detection of the cylinder is the responsibility of the Contractor.
Supply and filling copper sulphate.
Supply and filling Alum Crystal
Supply and filling Bleaching Powder
Supply and filling Soda Ash
Supply and filling Sodium hypo chloride
Supply only high strength calcium based granular dis-infectant for chlorination of water complete all as specified and directed by the Engineer - in - Charge. Make:- Puricloro/ Altoch/ Declibac Technologies/ Andhra Sugar or equivalent.
Supply and fixing in repair 25 mm dia CPVC pipes including all fittings and dismantling old 50 mm dia CPVC pipes.
Supply and fixing in repair 40 mm dia CPVC pipes including all fittings and dismantling old 40 mm dia CPVC pipes.
Supply and fixing in repair 50 mm dia CPVC pipes including all fittings and dismantling old 50 mm dia CPVC pipes.
Supply and fixing in repair HDPE pipe 100mm PN 10 dia and making suitable slots with complete fitting all as directed at site.
S&F in repairs self reinforced PVC 50mm dia Hilfiger hose in suction sweeper pump at sea survival unit all as specified and as directed by the Engineer - in- Charge.
Supply and fix in repair 8040 RO Membrane Spiral wound element with poly amide thin film composite membrane having working temperature and pressure 45 degree centigrade and 10 bar , max flow rate of 19 m3/hr ,max pressure drop of 1 bar ,PH range 2-11, free chlorine tolerance 0.1 PPM and salt rejection 99.5% all as specified and directed by engineer in charge. Make- Dupont/ GE/ DOW or equivalent as approved by GE
Supply and fixing in repairs pressure gauge (0-14kg/cm2) including necessary specials and provisions of suitable ferrule etc. all as directed by Engineer- in-charge
Supply and fixing Nylon brush size 0.60 mtr x 0.15 mtr including nut, bolt , washers and springs etc. complete all as specified and as directed by Engineer - in - Charge.
Excavation in trenches in soft / loose soil not exceeding 1.5 metre wide for foundation etc or for shafts, wells cesspits, manholes etc not exceeding 10 sqm on plan and not exceeding 1.5 metre in depth and getting out complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated material not exceeding 50 metre and deposited where directed at a level not exceeding 1.5 metre above the starting point in soil complete all as specified and directed.
M&L for Overhauling of suction sweeper pump of capacity 3 HP 440 Volts with replacement of gear oil, 'V' belt water seal 'O' ring set complete including reassembling back and testing complete all as specified and directed.
Material and labour for cleaning of water supply under ground sump for balancing capacity 50000 gallons by bailing out the accumulated water at the bottom and taking out & removing the complete sludge out side land and wash out completely, and wire brushing the tanks after scrubbing the walls and bottom of the tank completely with minimum disturbance of water to swimming pool and applying two coats of white wash inside the tank complete all as specified.
Material and labour for cleaning of swimming pool of sea survival unit of capacity 100000 gallons by bailing out accumulated water at the bottom and water over flow channels and cleaning the wall, bottoms surfaces by using suitable Tiles scrubbiest/ Acid without disturbance of Wall/ floor surfaces complete all as directed by Engineer- in-charge.
Maintenance and repair of LT panel board with replacement of SFU, fuse link, Ammeter, Volt meter, CT ratio, indicator lamp, Start/stop push Buttons etc complete including reassembling back and testing complete all as specified
Supply and fix in repair 2472 FRP Polyglass Vessel having inner material made up of Polythene seamless in one piece tank liner having dia 24 inches, working temperature in range of 45 to 60 degree centigrade, working pressure 10.34 Bar , having capacity of 450 Ltrs with warranty of one year of any manufacturing defect all as specified and directed by Engr-in-charge.
Supply and fix 40 NB Multiport valve for RO Plant having water capacity 5000 LPH working on manual mode operation all as specified and directed by Engr-in-charge.
Supply only antiscalant having sp gravity 1.05 to 1.10 and should be miscible in all proportion of water all as specified and directed by Engr-in-charge.
Supply and fix 20 Inches Spun filter Cartridge having porosity 5 Micron made up of Polypropylene all as Specified and directed.
S & F in repair metering Pump for RO Plant having Dosing rate @ 4 Kg/Cm² 1.5; 3.0; 6.0 & 10.0 Lph Suction/Discharge tubing 4/6 mm Frequency up to 400 rpm Electrical 230 V AC, 50 Hz. Power consumption at 400 rpm 30 W all as specified and directed by Engr-in-charge
S & F 7.5 HP Mono Block Pump having Head Range Upto 40 metres Discharge Range Upto 6.8 lps working on Voltage Range of 380 to 440 Volts 3 Phase supply with Moc for the delivery Casing,impeller,body is Cast iron and the shaft MOC is of Carbon steel all specified and directed by engr-in-charge
Supply & filling ENKLO 320 or equivalent oil for lubrication of air cooled compressor
Supply fix and install Stainless steel water tank of Capacity 2000 L along with stand and connected pipelines as required per site made from 304 food grade Stainless steel ,weather resistant ,built up of modern technology (Non Bacterial ), life long Durability , leak proof ,suitable for water ,having provision of draining out the sediments accumulated at the bottom all as specified and directed by Engineer- in -charge. Make- Hykon Cat Part - HYST-2000 or equivalent of NOVA SS TANK
Material and labour for scrapping the old painted surface and painting with two coats of synthetic enamel paint colour choice as directed by Engineer in charge, over one coat of red oxide primer including writing pump No. and capacity of the pump with white paint all as directed for the pressure filter pumps, pump, connected pipe lines, panel boards, Valves , Air compressor etc
Supply only Algaecide for Swimming Pool
Supply only PH reducer solution for Swimming Pool
Supply and fix in repair trolley (M.S.) mounted suction sweeper machine with cleaning kit and 3 HP motor Corrosion resistance, Prolong service life Performance oriented all as specified and directed by Engineer-in-charge
Supply and Fix in repair electrode set for Electro chlorination plant MAC 300 PLC Based continuous model having operating capacity 300 gm/hr of 100% free available chlorine working on 415 V, 3 Phase ,50 Hz AC in which each electrode consist of DSA ,anode and cathode manufactured using ASTM B 265.GR 1 Titanium plate material of 1.5 mm thick and coated with mixed metal oxide and should be bi polar all as specified and directed by Engr-in-charge
Supply and Fix in Dosing Pump for Electro chlorination plant MAC 300 PLC Based continuous model having operating capacity 300 gm/hr of 100% free available chlorine working on 415 V, 3 Phase ,50 Hz AC of capacity 46.0 LPH at Max pressure of 20 Kg/Sqcm injection pressure with PP wetted parts along with suction foot valve ,suction/discharge valves & NRVs,Suction and discharge CPVC Piping and including site fabrication work to be required to complete the installation all as specified and directed by Engr-in-charge
Supply and Fix in Brine forwarding Pump for Electro chlorination plant MAC 300 PLC Based continuous model having operating capacity 300 gm/hr of 100% free available chlorine working on 415 V, 3 Phase ,50 Hz AC of capacity and injection pressure as per site with PP wetted parts along with suction foot valve ,suction/discharge valves & NRVs,Suction and discharge CPVC Piping and including site fabrication work to be required to complete the installation all as specified and directed by Engr-in-charge
Supply only fine Salt used for Electro chlorination plant MAC 300 PLC Based continuous model for making brine solution all as specified and directed by Engineer in charge
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .