Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
8 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
Superintending Engineer.
O/o SE PPD and Sewerage Circle, Thiruvananthapuram
Others-Grey-Water Reuse Tertiary Treatment Plant at Muttathara 15MLD-Design, Construction and Commissioning of 15.00 MLD Tertiary Treatment Plant in the premises of Sewerage Treatment Plant at Muttathara and allied works-Sewerage Work.
2026_KWA_857111_1
WRD/KWACESEWA/TR/26741/2024RT1
Open Tender
Civil Works - Others
Muttathara
Please refer Tender Documents.
8 documents required · 8 mandatory
₹16,540
₹5 L
O/o SE PPD and Sewerage Circle, Thiruvananthapuram
22 Jun 2026
22 Jun 2026
10 Jul 2026
22 Jun 2026
8 Jul 2026
22 Jun 2026
29 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1APPENDIX -A :-15 MLD Tertiary Treatment Plant- Raw Water Channel | ||||||
| 1.001 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | - | cum | - | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | 4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded
stone aggregate 40 mm nominal size derived from natural sources) | 1 | cum | - | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | 5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level | - | cum | - | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | OD164330/2024-2025:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using SRC cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve work ability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :-Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @340 kg/cum).No extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.- All Floor levels | - | cum | - | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | - | sqm | - | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | - | sqm | - | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | - | sqm | - | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | - | sqm | - | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform | - | sqm | - | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.23 MB
NIT1.pdf
Tender Documents • 1.69 MB
BOQ_1448813.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid