| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.8 L+₹1.9 L (28.3%)Rejected-AOC 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L2 | Rejected-AOC L2 | |
| 3 | L3₹10.2 L+₹3.3 L (48.3%)Rejected-AOC HOUSE NO 2734 2ND FLOOR PHASE 7 SAS NAGAR MOHALI PUNJAB | S A S NAGAR | PUNJAB | 140103 | L3 | Rejected-AOC L3 | |
| 4 | L4₹11.3 L+₹4.4 L (64.6%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-AOC L4 |
Tender Value
₹10.1 L
EMD Value
₹20,500
Closing Date
12 May 2020, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
REPAIRS TO ELECTRICAL WIRING, GEYSERS,FAN AND FITMENT ETC AT AF STN MULLANPUR UNDER GE(AF) CHANDIGARH
2020_MES_310980_2
8149/T-46/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Chandigarh
All as per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹20,500
Yes
6 Feb 2021
14 Mar 2020
13 May 2020
14 Mar 2020
12 May 2020
23 Mar 2020
Amount
Taking down carefully with battens/ PVC surface/ concealed conduit unserviceable copper/ aluminium point wiring (light, fan, socket) complete including fittings such as switches, ceiling roses, pendants, socket etc. and removing unserviceable material from site and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
Point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in and including 19mm dia nonmetallic rigid PVC concealled conduit medium grade including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, using the existing pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting of switches sockets fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified. NOTE: (a).The quoted rates includes the cutting chasis for conduit and sunken boxes.
All as per item No. 2.00 here-in-before but point wiring for one 5Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 2.00 here-in-before but point wiring for one 5Amps socket outlet point on d same board controlled by one single pole, one way switch complete all as specified.
All as per item No. 2.00 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push complete all as specified.
All as per item No. 2.00 here-in-before but point wiring using 2.5 sqmm as main wire & 1.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 2.00 here-in-before but point wiring using 4sqmm as main wire & 2.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
Point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in the existing conduit medium grade including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, using the existing pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting of switches sockets fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified.
All as per item No. 8.00 here-in-before but point wiring for one 5Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 8.00 here-in-before but point wiring for one 5Amps socket outlet point on d same board controlled by one single pole, one way switch complete all as specified.
All as per item No. 8.00 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push complete all as specified.
All as per item No. 8.00 here-in-before but point wiring using 2.5 sqmm as main wire & 1.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 8.00 here-in-before but point wiring using 4sqmm as main wire & 2.5Sqmm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
Switch piano, flush type, single pole, one way, 5 Amp, 230volts complete all as specified.
Switch Bell push, flush type, single pole, one way,, 230volts complete all as specified.
Switch piano, flush type, single pole, one way, 15 Amp 230volts complete all as specified.
Socket outlet multipurpose 3 pin, 5 Amp and 2 pin 5 Amp, flush type, complete all as specified.
Socket outlet multipurpose 3 pin 5 Amp & 15 Amp, flush type, complete all as specified.
Ceiling rose, three terminals, PVC/ isolated body, complete all as specified.
Call bell, electric Ding - Dong type (Domestic pattern), 230 volt, single pole, complete all as specified.
Fan regulator electronic, socket type, suitable for 1200mm /1400mm sweep ceiling fan, fixed in repairs, with and including provision of PVC flexible cable of size 1sqmm copper conductor as required, complete all as specified.
Taking out/down fluorescent tube light fittings of any type / capacity complete and deposited to the E/M store yard/kept at site in safe custody cmplete all as specified and as directed.
Supply and fixing, LED Decorative box type batten fitting 1x18 to 22W, prewired suitable for retrofit LED tubes, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1. Sq. mm from ceiling roseto connector block, including taking down old unserviceable surface mounted fitting of any wattage and type, complete all as specified and directed by Engineer-in-Charge. Make: Havells cat No REGALBATTENT 8UPTO1X22WSSBSWH or equivalent in WIPRO/PHILLIPS.
Supply and fixing Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver 9W including taking down old unserviciable surface mounted fitting of any watage and type complete all as specified and directed. Make : Cat no LUMILINEBS9WLED830SPCWH of Havells or its equilant in Crompton/Wipro
Supply and fixing in repair LED tube rod 20 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x18W to 22W, complete all as specified and directed Make : Havells cat No PHOTONULTRA 1213T8SSTL20WLED865SPC or equivatent in WIPRO / PHILLIPS.
Supply and fixing wall mounted fittings with ABS housing and clear polycarbonate cover including LED bulb 15watts complete and provision of flexible copper 3core cable 0.5Sqmm from connector/ ceiling rose to fitting all as specified and directed Make : Havell's /equivalent HPL code HPL81410(CW) /Bajaj/philip
Supply and fiixing Ultra modern designed architectural LED luminaire 42W which provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling Make : Cat no VENUSNEOHE2X2PLR42WLED8XXS of Havells or its equilant in Cromptorn/ HPL
S&F LED 8 watts bollard garden light fitting with robust design and efficient light distribution including light fitting fixing and making PCC block foundation and connecting the fittinngs on PCC foundation block complete all as specified and directed. Make- Havells Cat Part No CONEBL8WLED857SSYMTOPC or equivalent in WIPRO/ PHILLIPS/Crompton.
M&L for PCC 1:3:6 type C.1 using 20mm graded aggregate as in cooping/PCC block for fixing of bollard light fitting complete all as specified and directed
Sheet metal enclosure single pole and neutral with a two pin socket and earth plug complete with one MCB single pole and 240V, 20 Amp ‘B’ curve, 10 kA, including taking out old unserviceable complete all as specified.
Sheet metal enclosure (DB) single phase with neutral,2 way, 240 volt without bus bar & IP 54 protection, including taking out old unserviceable complete all as specified and directed by Engineer-in-Charge.
Sheet metal enclosure (DB) single phase & neutral, double door 4 way, 240 volt with 200 Amps rated bus bar & IP 54 protection, including taking out old unserviceable complete all as specified and directed by Engineer-in-Charge.
All as per item No. 32.00 here-in-before but DB 8waycomplete all as specified.
All as per item No. 32.00 here-in-before but DB 12waycomplete all as specified.
Sheet metal distribution board TPN, with double door,4 way, 415 volt with 200 Amps rated bus bar & IP 54 protection, including taking out old unserviceable complete all as specified and directed by Engineer-in-Charge.
All as per item No.35.00 here-in-before but DB 8waycomplete all as specified.
S & F MCB DB, TP & N, vertical Loadline, 8 ways, double door, with provision for MCCB, having IP-43 protection complete all as specified.
S & F MCCB, TP, 100 Amps, 415 Volt, having breaking capacity 10 kA, fixed thermal & fixed magnetic setting, Ics=100% of Icu including taking down old MCCB complete all as specified.
MCB 63 Amp, 415 Volt, TPN, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified.
MCB 32/40 Amp, 415 Volt, TPN, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified.
MCB 63 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
MCB 40 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
MCB 32 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
MCB 32/ 40 Amp, 415 Volt, SPN, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
MCB 6 to 32 Amp, 240 Volt, SP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
Sub main wiring with two single core 10.0 Sq.mm (nominal area) PVC insulated and unsheathed cables with stranded copper FR conductor in existing conduit including one run of continuous PVC insulated FR copper stranded cable of wiring size 6.0 Sq.mm for earth continuity including taking down old unserviceable cable, complete all as specified. Notes :- (i) 2 runs of 10 Sq.mm main cable + 1 run of 6.0 Sq.mm earth cable considered as 1 Running Metre.
All as per item No. 46.00 here-in-before but using 2 single 6Sqmm as main & 1 single core 4Sqmm as earth wire complete all as specified.
All as per item No. 46.00 here-in-before but using 2 single 4Sqmm as main & 1 single core 2.5Sqmm as earth wire complete all as specified.
PVC non metallic rigid concealled conduit 25mm, medium grade inclusive of junction, bends, elbows, tees, reducers, bell mouth tube ends fixing accessories such as couplers lock nuts, saddles, pipe hooks etc. including cutting chases for conduits and taking down existing batten/ conduit and making good to wall as per existing specifications complete all as specified.
Material and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 3mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI wire 4mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and of earth wire protected by galvanized iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 5 of SSR-2009 (Part-I).
Taking up / down water heater (Geyser) of capacity 50/35/25 ltrs operating on 230 volts AC electric supply, in any position and of any make, after disconnecting all electric connection and hot and cold water connection, and including transportation to the contractor 's workshop for repair and vice - versa, , and painting / numbering ( if necessary) and vice - versa after repairing, general cleaning/overhauling, cleaning and discaling the tank and assembly with suitable detergent and making fully serviceable and fixing back in same location / position or new location all as directed. Note :- (a) Repairing of any parts except the work mentioned in item No1.156 will be maasured and paid seperatelly. (b) Replacement of any un serviceable parts required for making the geyser serviceable will be measured and paid seperatelly under "supply only" No extra payment will be allowed for replacing these items, as the same is deemed to be included in relevant item.
Stainless steel inner tank suitable for 25 ltrs Geyser of any make / shape /holes for fixing geyser assembly.
All as per item No 52.00 herein before but for 35 ltrs.
All as per item No 52.00 herein before but for 50 ltrs.
Supply only bottom base assembly of copper 9/8/7/6 holes type suitable for 35/25 ltrs capacity geyser all as directed.
All as per item No 55.00 here-in- before but for 50 ltrs capacity geyser .
Heating element 2000 watts capacity of any shape /type with rubber gasket . Make :- Ditz, Dass pass
Thermostat suitable to adjust the temperature from 0º C to 80º C all as directed. Make :- Ditz, Dass Pass
Glass wool of good quality as approved by Engr-in-Charge.
Neon indicator lamp of any shape / size / colour all as directed.
PVC insulated, sheathed 3 core flexible cable of size 2.5Sqmm all as directed.
Safety plug any type complete.
Supply & fixing non return valve 15mm bore castcpper alloy suitablwe for geyser complete all as specified and as direceted
Rubber gasket of thickness 5 mm for geyser assembly of 08 holes / 09 holes all as specified.
Bottom inspection cover plate in two pieces with suitable openings for indicator lamps, power cable entry with rubber washer etc, gauge of plate not less than 18 SWG for 25/35/50 Ltrs capacity geysers of any make/ shape all as directed.
Supply anly 3 pin plug top 15 Amps, bakelite suitable for 230/240 volts AC supply all as directed.
GI nut bolts and washers (not exceeding the size 12mm dia x 150 mm Lenght) of existing size of geyser spare parts complete
Outer MS shell complete including top and bottom suitable for 25 Ltrs capacity geyser of any make, shape & size as per existing but gauge of sheet not less than 22 SWG all as directed.
PVC connection 15mm bore 450mm long in any position with both end brass nut with inner thereading and washer suitable for cold water connection complete all as directed .
CP connection 15mm bore 450mm long in any position with both end brass nut with inner thereading and washer suitable for cold water connection complete all as directed .
M/L for spray painting of geyser outer body of any make / size by applying one coat of synthetic enamel white paint over the existing paint including cleaning and preparation of surface, and writing of MES NO with synthetic enameled black paint in bold letters of size not less than10mm all as directed
Taking down and Re-Fixing , installation and testing of Storage type water heaters (Geyser) 25 Ltrs capacity operated on single phase AC electric supply, connection etc. including making good to the distrubed surface complete all as directed.
Disconnecting & taking down complete ceiling fan with blade of any make 1200 mm / 1400 mm sweep from fan hook/ fan box, transporting to local workshop , opening, cutting and taking out complete copper winding , cleaning with kerosene oil /diesel/ terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge and number of turns as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff/strip type) replacing u/s providing paper insulation (cuff / strip type) replacing u/s / missing spare (bush, bearing, capacity shackle insulator, canopy, nuts , bolts, earthing , screw, upper, socket, CI block , quarter /split pin (top & bottom) , lock nut etc fixing the stator in rotor properly aligned and resembling ensuring right DOR, speedy and noiseless running and connecting cable and depositing in E/M yard complete all as directed by Engr in charge Note: Bush, bearing, capacitor, and canopy, shackle insulator with nuts, bolts and sockets shall be measured and paid for separately.
Supply only capacitor 2.50 MFD, 440 Volt AC, 50 Hz plastic body powder filled type complete all as directed.
Supply only capacitor 3.15 MFD, 440 Volt AC, 50 Hz plastic body powder filled type complete all as directed.
Supply only MS fan clamps with rubber real including nuts and bolts, split pin suitable for ceiling fan 1200 / 1400 mm sweep complete all as directed.
Supply only bearing suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.
Supply only bush suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.
Supply only PVC Canopy suitable for ceiling fan of 1200 / 1400 mm sweep set of two complete all as directed.
Supply only PVC insulated flexible 3 core, 1sqmm size copper conductor cable of size 1sqmm copper conductor including taking out the old unserviceable PVC flexible wire complete all as specified all as specified and directed by Engineer in Charge.
Supply & fixing for Mild Steel Down Rod of suitable dia , 45 Cms long white or coloured, compatible to existing ceiling fans of 1200mm or 1400 mm sweep including taking out old unserviceable down rod from the fan complete all as specified and as directed by the Engineer–in-charge. Down-Rod shall be of make of existing fan or as approved by the GE.
Disconnecting and taking down ceiling fan of any sweep for carrying out overhauling such as cleaning ,oiling, lubricating, greasing etc and replacement of minor parts such as washer, split pins/ blade screw etc and defective parts, if any, and refixing the ceiling fan on same location and connecting it properly and testing for noiseless running to the entire satisfaction of Engineer-in-charge. Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only. (ii). Cost of the minor parts i.e. washer, split pins/ blade screw etc deemed to be included in unit rate & nothing shall be paid on this account.
Spray painting of ceiling fan 1200/1400 mm sweep and testing at site full load with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape complete all as directed by Engr-in-charge.
Disconnecting & taking down (burnt) exhaust fan of any make 300mm sweep transporting to local workshop, opening, cutting and taking out complete copper winding , cleaning with kerosene oil / diesel/ terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff /strip type) replacing u/s / missing spare (bush, bearing , capacity etc) fixing the stator in rotor properly aligned and reassembling ensuring right DOR , speedy and noiseless running and depositing in E/M yard Note: Bush bearing capacitor shall be measured and paid for separately.
All as per serial item No. 84.00 here-in-before but exhaust fan 450 mm sweep.
Supply and fix in repair capacitor 4 MFD, 440 Volt AC, 50 Hz plastic body powder filled type for exhaust fan of 300/400mm sweep complete all as directed.
Disconnecting and taking down exhaust fan of any sweep for carrying out overhauling such as cleaning ,oiling, lubricating, greasing etc and replacement of defective parts, if any, and refixing the exhaust fan fan on same location and connecting it properly and testing for noiseless running to the entire satisfaction of Engineer-in-charge. Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only. (ii). Cost of the minor parts i.e. washer, split pins/ blade screw etc deemed to be included in unit rate & nothing shall be paid on this account.
Supply only bearing suitable for 300 / 400/ 450 mm sweep Exhaust fan complete all as specified and directed.
Spray painting of Exhaust fan and testing at site full load with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape complete all as directed by Engr-in-charge. (Bush, bearing, capacitor, canopy, shackle insulator with nuts, bolts and sockets will be measured and paid separately).
Collecting unserviceable (burnt) table / cabin fan of any make and sweep up to 450 mm from Internal Elect Section, transporting to local workshop, opening, cutting and taking out complete copper winding, cleaning with kerosene oil / diesel / terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufacturers, varnishing and heating the winding including providing paper insulation (cuff / strip type), replacing unserviceable / missing spares (bush, bearing, capacitor etc), fixing the stator in rotor properly aligned and reassembling ensuring right DOR, speedy and noiseless running and depositing in E/M Yard for further issue to the user.
Note:- Amount of credit of Rs. 32319.00 for retrieved materials is mentioned in Schedule of Credit Page No 106 & 107 of tender documents in pdf form which will be deducted offline while acceptance of tender
HARISH SALES CORPORATION
DHILLON CONSTRUCTION CO
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .