Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 CrAccepted-AOC 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹16.7 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹18.7 CrRejected-AOC 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹18.7 Cr | L2 | Rejected-AOC Other than lowest |
| 3 | L3₹19.6 CrRejected-AOC | ₹19.6 Cr | L3 | Rejected-AOC Other than lowest |
| 4 | L4₹20.6 CrRejected-AOC | ₹20.6 Cr | L4 | Rejected-AOC Other than lowest |
| 5 | L5₹20.7 CrRejected-AOC | ₹20.7 Cr | L5 | Rejected-AOC Other than lowest |
Tender Value
₹17 Cr
EMD Value
₹11.8 L
Closing Date
10 Feb 2024, 6:00 pmClosed
CE Chandigarh Zone
HQ CE Chandigarh Zone N Area, Airport Road Chandigarh-160003
CA NO CE CHZ/AMB/T-10/2023-24 PROVN OF OTM ACCN FOR WORKSHOP AT AMBALA CANTT
2023_MES_624820_1
CE CHZ/AMB/T-10/2023-24
Open Tender
Civil Works
550 days
AMBALA CANTT
Please refer Tender Documents
10 documents required · 10 mandatory
₹3,000
GE (SOUTH) AMBALA CANTT
₹11.8 L
Yes
23 Mar 2024
26 Oct 2023
12 Feb 2024
15 Dec 2023
10 Feb 2024
20 Jan 2024
26 Oct 2023 - 6 Nov 2023
Amount
Total amount of Sch 'A' Sec-I ( BUILDING WORKS ) Lump sum price worked out by the contractor for " BUILDING WORKS " as listed in schedule 'A' Part-I
Total amount of Sch 'A' Sec- II (SITE CLEARANCE, SITE DEVELOPEMENT & MISC. EARTH WORKS) Lump sum price worked out by the contractor for " SITE CLEARANCE & Earth Works " as listed in schedule 'A' Part-II
Total amount of Sch 'A' Sec- III ( INTERNAL WATER SUPPLY WORKS ) Lump sum price worked out by the contractor for " INTERNAL WATER SUPPLY WORKS " as listed in schedule 'A' Part-III
Total amount of Sch 'A' Sec- IV (INTERNAL ELECTRIFICATION AND ANCILARY WORKS OF COMMUNICATION NETWORKS) Lump sum price worked out by the contractor for " INTERNAL ELECTRIFICATION AND ANCILARY WORKS OF COMMUNICATION NETWORKS " as listed in schedule 'A' Part-IV
Total amount of Sch 'A' Sec- V (SEWAGE DISPOSAL WORKS) Lump sum price worked out by the contractor for " SEWAGE DISPOSAL WORKS " as listed in schedule 'A' Part-V
Total amount of Sch 'A' Sec- VI (ROAD, PATH, CULVERTS AND HARDSTANDING WORKS) Lump sum price worked out by the contractor for " ROAD, PATH, CULVERTS AND HARDSTANDING WORKS " as listed in schedule 'A' Part-VI
Total amount of Sch 'A' Sec- VII (AREA DRAINAGE WORKS) Lump sum price worked out by the contractor for " AREA DRAINAGE WORKS " as listed in schedule 'A' Part-VII
Total amount of Sch 'A' Sec- VIII (SECURITY WALL, GATE & FENCING WORKS) Lump sum price worked out by the contractor for " SECURITY WALL, GATE & FENCING WORKS " as listed in schedule 'A' Part-VIII
Total amount of Sch 'A' Sec- IX (RAIN WATER HARVESTING WORKS) Lump sum price worked out by the contractor for "RAIN WATER HARVESTING WORKS " as listed in schedule 'A' Part-IX
Total amount of Sch 'A' Sec- X (EXTERNAL WATER SUPPLY WORKS) Lump sum price worked out by the contractor for " EXTERNAL WATER SUPPLY WORKS " as listed in schedule 'A' Part-X
Total amount of Sch 'A' Sec- XI (HOT WATER SUPPLY WORKS) Lump sum price worked out by the contractor for " HOT WATER SUPPLY WORKS " as listed in schedule 'A' Part-XI
Total amount of Sch 'A' Sec - XII EXT ELECTRIC SUPPLY & LIGHTENING PROTECTION WORKS) Lump sum price worked out by the contractor for " EXT ELECTRIC SUPPLY & LIGHTENING PROTECTION WORKS " as listed in schedule 'A' Part-XII.
Total amount of Sch 'A' Sec- XIII ( ARBORICULTURE WORKS) Lump sum price worked out by the contractor for " ARBORICULTURE WORKS " as listed in schedule 'A' Part-XIII.
Total amount of Sch 'A' Sec- XIV (SUMMER APPLIANCES WORKS) Lump sum price worked out by the contractor for " SUMMER APPLIANCES WORKS" as listed in schedule 'A' Part-XIV.
Total amount of Sch 'A' Sec- XV (DEMOLITION WORKS) Lump sum price worked out by the contractor for " DEMOLITION WORKS " as listed in schedule 'A' Part-XV.
Provide a Provisional Sum for following work under terms and condition 1(v) and 5 of IAFW-2249 (General Conditions of Contracts) (a) Provision of Foot Ball ground/Hockey ground (b) Provision of Basket Ball ground (c) Provision of Volley Ball ground (d) Provision of Parade ground (Small) 5350 Sqm (e) Provision of Ramp for Garrages
Schedule 'A'Section-XVII (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
LIST OF WORKS AND PRICES FOR INTERNAL ELECTRIFICATION AND ANCILARY WORKS OF COMMUNICATION NETWORKS Concealed point wiring using approved colour coding as per IS, with 1.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H, drawn through and including heavy duty PVC conduit of appropriate dia (2mm wall thickness) and conduit accessories ISI marked, PVC junction boxes etc, concealed in walls/ceiling/floors including 1.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H as earth continuity conductor to common earth & connecting to earth dolly for the following :-
One light/bell/fan point (Ceiling/ Wall/ Exhaust) controlled by one number one way switch or one number one way switch and regulator
One light point conrolled by two numbers two way switches
One 5/6 Amps socket outlet on independent board
One 5/6 Amps socket outlet on the same board with other switches
Concealed point wiring using approved colour coding as per IS, for 15 Amps socket outlet on independent board with 2.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H, drawn through and including heavy duty PVC conduit of appropriate dia (2mm wall thickness) and conduit accessories ISI marked, PVC junction boxes etc, concealed in walls/ceiling/floors including 2.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H as earth continuity conductor to common earth & connecting to earth dolly. Notes for item Nos. 18 to 19 : (a) Modular metal flush boxes, modular cover plates with frame and switches/sockets etc shall be measured and paid separately under respective items of Sch 'A'/BOQ here-in-after. (b) Cost of cutting/chases for concealing of conduit shall be deemed to be included in quoted lump sum of Sch 'A' Section-I.
Supply and fixing modular Blanking plate 1 module complete all as specified and directed.
Supply and fixing modular metal flush box of 8 module complete all as specified and directed.
S & F Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings Type B-22 complete all as specified and directed.
Supply and fixing LED bulb, 9/10 Watts, B-22 complete, all as specified & directed.
Sheet metal enclosure vertical type double door DB TPN 4 way suitable to accomodate MCCB FP, 415 volts upto 100 Amps rating, protection class IP-54 IK-09 made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted as per IEC 61439-3, with copper bus bar of 200 Amps capacity for each phase, with two neutralbars, two Earth bars and cable ties for cable management including provision of one No. MCCB four pole 100 Amps confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 16 KA at 415 V AC , 50 Hz complete all as specified and directed. (Note: MCBs shall be measured and paid separately)
MCB SP, 240 Volt , 50 Hz, 6 to 32 A, 10 KA , "B" curve, complete all as specified and directed.
MCB SPN,16-32 Amps, 'B' Curve , 240 volt , 50 Hzs,10 KA, complete all as specified and directed.
Supply and fixing MCB TP 40 Amps, 415 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
Supply and fixing MCB TPN/FP 63 Amps, 415 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
S & F single pole and neutral sheet metal enclosure with a two pin and earth plug with socket complete with one single pole MCB 20 Amps, complete all as specified and directed.
Supply and fixing BLDC Ceiling fan energy efficient, minimum service value (m3/minute/Watt)>= 6.0, including modular electronic step type fan regulator, 2 module 120 watts fixed on cover sheet, 230 V, 50 Hz, 1200 mm sweep confirming to IS 374-2019, with all standard accessories as per manufacturer's recommendations, Opal white colour, winding with super enameled, copper wire, class B insulation. BEE 5 star rated with provision of PVC insulated flexible cable FRLSH grade 3 core 0.5mm copper conductor 1100 volts grade from porcelain connector /ceiling rose to ceiling fan,complete all as specified and directed.
S & F Energy saving LED light fitting , 1 x 20 watt, 230 volts, Decorative ultra slim linear LED lighting fixture with extruded Aluminium housing,environmental friendly, energy efficient ready to use pack with electronic driver and with best quality diffuser high lumen output, 2.5 KV voltage surge protection, PF 0.98, THD < 10 % suitable for surface/ pendant mounting complete with all accessories including and connecting of with twin core of PVC insulated 0.75 Sqmm copper conductor cable complete all as specified and directed. Note for item No 31 to 35:- (i) Lumen output greater than 110 lumen per watt.” (ii) Make of Driver and Luminaries shall be same. (iii) Manufacturer should have in-house NABL accreted Lab for testing and certification of the same shall be submitted to GE before approval of the material
Supply & fix LED mirror light with Linear & compact 9 W mirror light with decorative grey end caps, Aluminium housing and ribbed opal diffuser of capacity 9 watt complete all as specified and directed.
Recess mounted LED luminaire 600mm x 600mm size, 35/36 watt, 230 V, 50 Hz with highefficiency PMMA diffuser for soft glare free light colour temperature white with all standard fittings pre-wired and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed.
S & F Energy generation energy saving and environmental friendly long life LED building security light 1 x 35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having top opening separate driver compartment IP 65 protection and impact resistance of IK 07, with all accessories including suitable bracket with 32 mm bore light grade GI pipe bent to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed.
S & F new generation energy saving and environmental friendly long life industrial 150 watts LED Highbay luminaries with clear PC diffuser powded coated aluminium body IP 65 CCT 5700K mounting with eye bolt and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed.
Exhaust fan of 300mm sweep,metal body, heavy duty, double ball bearing, 1400 RPM, 90 watt, 4 blades, air delivery 1710 m3/h, suitable for SP 230/250 Volts, 50 Hz AC supply complete with louver shutter including fixing/ grouting of frame & louvers in wall using bolts of bolts of suitable size & connecting with and including PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to fan complete all as directed. Note : Cost for making opening in wall and grouting of mild steel work shall be deemed include in the lump sum cost of the building.
Exhaust fan of 450mm sweep,metal body, heavy duty, double ball bearing, 1400 RPM, 350 watt, 4 blades, air delivery 6120 m3/h, suitable for SP 230/250 Volts, 50 Hz AC supply complete with louver shutter including fixing/ grouting of frame & louvers in wall using bolts of bolts of suitable size & connecting with and including PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to fan complete all as directed. Note : Cost for making opening in wall and grouting of mild steel work shall be deemed include in the lump sum cost of the building.
Exhaust fan of 600mm sweep,metal body, heavy duty, double ball bearing, 900 RPM, 450 watt, 4 blades, air delivery 9400 m3/h, suitable for SP 230/250 Volts, 50 Hz AC supply complete with louver shutter including fixing/ grouting of frame & louvers in wall using bolts of bolts of suitable size & connecting with and including PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to fan complete all as directed. Note : Cost for making opening in wall and grouting of mild steel work shall be deemed include in the lump sum cost of the building.
Supply & fix heavy duty wall mounted industrial fan with aerodynamically designed blades for higher air delivery and minimum noise level double ‘z’ shielded ball bearing for longer life conforming to IS : 2997-1964 standards with speed 1440 RPM, sweep size 750 mm, air delivery 18000 cum/hr, 3 No of blades, size 30 inch and power requirement 235 watt complete all as directed.
Flame proof/weather proof direct entry type rotary switch single pole,totally enclosed, on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 16 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc duly tested & certified by CMRI-Dhanbad complete all as specified and directed.
Supply & fixing LED light fitting 1 x 8 watt flame proof, CMRI certified recommended for gas/vapour group of II A & III B , Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture driver, holders, connector etc. Complete with all accessories prewired and incl connecting up with three core flexible copper conductor cable suitable size complete all as directed.
Supply and fixing Modular socket outlet for Tele one Module ISI marked complete all as specified and directed.
Supply and fixing Modular socket outlet for RJ-45 Jack with Cat 6 one Module ISI marked complete all as specified and directed.
Supply and fixing Modular socket outlet for TV one Module ISI market complete all as specified and directed.
ROAD, PATH, CULVERTS AND HARDSTANDING WORKS M & L for precast (factory casted) cement Concrete kerb stone casted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with plain or interlocking joints (as directed), making groove in existing road of desired dimension, placing in erect position Kerb stone in edging and set and jointed in cement mortar 1:4, making good distrubed surface of ground complete all as specified and directed.
M & L for laying and compacting 150mm thick (compacted thickness) Granular Sub Base (GSB) grading as per Grading II of Table 400-1 of MoRTH specifications for Road and Bridge works, 2013 in a single layer over compacted sub grade consisting of natural sand, crushed gravel, crushed stone, crushed slag, or combination thereof as per the grading required. The materials are mechanically mixed, spread and leveling on the sub grade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of at least 98 % of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MoRTH specifications for Road and Bridge works, 2013 complete all as specified and directed.
Providing, Laying, compaction of Wet Mix Macadam conforming to Clause 406 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) , 250 mm thick (compacted thickness,125 mm thick in two separate layers) with mechanically crushed graded stone aggregates and granular material (size range 53 mm to 0.075 mm ), grading of aggregates as per Table 400-13 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) ,including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 12 tonne capacity to achieve the desired density , required gradient and camber etc., complete all as specified and directed by Engineer-in-Charge. NOTES: 1. The WMM shall be laid in two layers i.e each layer of 125 mm thick (compacted thickness). 2. For payment purpose,both layers shall be considered as one unit.
Preparation of un-surfaced Wet Mix macadam (WMM) surfaces by brushing with wire brushes for removing caked mud ,dust, loose material, foreign material etc., sweeping with power brooms and finally fanning the cleaned surface with air compressors to remove all loose dirt etc. and applying evenly a priming coat on un-surfaced wet mix macadam surfaces conforming to Clause 502 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion SS1 grade,confirming to IS 8887(latest edition) @ 7.5 kg per 10 sq metres using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed.
Providing, laying & compaction of Bituminous Macadam (BM) conforming to Clause 504 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), using mechanically crushed stone aggregates and granual material etc. of grading II as per Table 500-7 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), premixed with bituminous binder, Bitumen grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density complete all as specified and directed. Notes : (i) The contractor shall quote the rate against Item considering 3.5% VG-30 bitumen content. Job mix formula as per MoRT&H specifications for road and bridge work (Fifth Revision) for bituminous concrete shall be got designed from NIT/ CTL/ Govt Engg College and shall be got approved from GE in writing well before commencement of work without any financial effect to the department. Also the bitumen content shall not be less 3.4% by weight of total mix as per clause 504.2.4 of MoRT&H specifications (Fifth Revision). (ii) If qty of binder contents is less than the qty as specified in respective items of BOQ, it shall be adjusted at supply only rates of paving bitumen @ Rs 45.00 Per Kg and if qty of binder contents is more than the qty as specified in respective items of BOQ no adjustment shall be made.
Preparation of bituminous black top surfaces and applying evenly a Tack coat conforming to Clause 503 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion RS1 grade,confirming to IS 8887(latest edition) @ 2.5 kg per 10 sq metres using using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed.
Providing and laying 30 mm thick (consolidated thickness) Bituminous Concrete (BC) layer conforming to clause 507 of MoRT&H specifications for road and bridge work (Fifth Revision) including cost of coarse aggregates, fine aggregates, filler, 5.5% binder (paving Bitumen grade VG-30) content by weight of total mix and crushed aggregates of grading 2, Anti Stripping Agent, Warm Mix Additives (quantity, quality and grade as per the approved Job Mix Formula) etc, cleaning and pre-heating of the mineral aggregate, filler & bitumen to the specific temperature, thoroughly mixing with binder of specified bitumen content, Anti Stripping Agent, Warm Mix Additives as per mix design in Hot Mix Plant of 100-120 TPH capacity, carrying the hot mixed materials by means of tipper, trucks, or any other approved and suitable arrangements, laying the hot premixed materials over the prepared surface by means of paver finisher including manual operation as and when required for proper grade, level and camber thorough rolling with power roller 8 to 12 tonnes smooth wheeled, vibratory and tandem roller with necessary hand packing and pinning to give an even surface, including running expense of all plants and machineries, inclusive of proper traffic control during laying to the satisfaction of Engineer-in-Charge, required quality control tests at required interval etc complete in all respects complete all as specified and directed.
Painting lines, dashes, arrows, letters etc on road pavement and the like exceeding 10 cm wide with Thermo Plastic Paint including glass beads complete all as specified and directed.
ABS Body Road studs (Cat eye) two way reflective of size 100 x 100 x 19mm with with reflective panels Amber/Red/White as directed fitted with epoxy resin and 12mm dia size 125mm long pointed nails complete all as specified and directed.
S & f Solar Light Road studs LED based of size ( 108 x 108 x 25 mm) with Aluminium alloy body and Solar powered by nano crystal solar panel with one high capacity NI- CD Recahrgeable battery and three LED on each side (total six LEDs) fixed with epoxy resin and 12mm dia size 125mm long pointed nails complete all as specified and directed.
M&L Bringing approved earth from outside MD land including cost of earth & carriage complete all as specified and directed.
Forming embankment from soil including raising (or lowering) earth, spreading in layers not exceeding 30 Cm thick, watering, ramming/rolling and finishing to required size, shape, etc, not exceeding 1.5 metre high from base under optimum moisture conditions to specified proctor density not less than 95 percent complete all as specified and as directed.
Forming embankment from soil including raising (or lowering) earth, spreading in layers not exceeding 30 Cm thick, watering, ramming/rolling and finishing to required size, shape, etc, exceeding 1.5 metre but not exceeding 3.0 metre high from base under optimum moisture conditions to specified proctor density not less than 95 percent complete all as specified and as directed. Note for item Nos & : For payment purpose quantity after deduction of 5% for bulkage from measured volume of filling shall be allowed.
M & L for 60mm thick PVC moulded precast interlocking paving blocks factory casted using grey cement and pigment, casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, confirming to IS-15658-2006 and of shape haxagon/ triangular/ zigzag/ I-shaped etc. as directed having compressive strength not less than 350 Kg/ Sqcm laid over and including 25 to 30mm thick layer of sand cushioning including filling the interstices with & including sand and interstices on edges filled with PCC 1:2:4 type B-1 finished even and smooth without using extra cement complete all as directed.
M & L for cutting existing road upto 30 Cm depth and in required width for laying sewage line/ water pipe line/cable and making good disturbed surfaces with plain cement concrete 1:2:4 type B-1 complete all as specified and as directed.
Centrifugally cast ductile iron pressure pipe 100 mm bore, with socket & spigot ends ISI marked with IS 8329/2000 classification K7, In standard length of 5.5 - 6 mtr suitable for and including push on joint (gasket D jointing) with cement mortar lining in the pipes, complete all as specified and directed. NOTE:-Ductile iron fittings will be measured and paid for separately.
Ductile iron fittings such as bends (any type, radius and angle) Tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket/spigot caps and plugs suitable upto 150 mm bore ductile iron pressure pipes of K-7 classification including nuts, bolts, washer and push on flexible rubber gasket joints, complete all as specified and directed.
Construction of brick masonary valve pit of size 900 mm x 900mm x 900 mm (Internal size) thickness of walls shall be 23cm in brick work in cement mortar 1:6 internally plastered in cement mortar (1:6) and externally plastered in cement mortar (1:4) over 15cm thick PCC 1:4:8 type D-2 having 15cm offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 on the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40 mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
Construction of brick masonary valve pit of size 600 mm x 600mm x 600 mm (Internal size) thickness of walls shall be 23cm in brick work in cement mortar 1:6 internally plastered in cement mortar (1:6) and externally plastered in cement mortar (1:4) over 15cm thick PCC 1:4:8 type D-2 having 15cm offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 on the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40 mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
Supply, installation, testing & commissioning of 200Lpd Solar water heating system indirect type (with SS 304 Heat Exchange) consisting of 2no. Solar flat plate collector ISI Marked with Copper absorber & 50mm insulation of rockwool at back and 25mm on sides with 100mm Aluminium box with 1 no. toughned glass 3.2mm with 92% transmittance and Solar hot Water Storage Tank 200Litres.SS304 (1mm thick) covered with 50mm PUF insulation and cladded with colour coated GI 0.4mm with 1x2kw electrical back up with suitable 3 core cable as required and thermostat with 1no. temperature gauge, 1No. Makeup Tank SS 304 with float valve and necessary hose pipe between collector & Hot water Tank System fixed over on Ms angle iron 40x40x50mm including nuts bolts, grouted in PCC 1:2:4 type B-1 blocks (30cmx30cmx30cm) and two coats of painting over coat of red oxide, brass gate valve in hot & cold water pipes complete all as specified & as directed. Note (i) Cost of PVC tank, Cold & Hot water pipe with their fitting & water taps shall be measured and paid for separately (ii) MS Angle structure shall be prepared as per manufacturer’s instruction.
Supply, installation, testing & commissioning of 300Lpd Solar water heating system indirected type (With SS304 Heat Exchange) consisting of 3no. Solar dlat plate collector ISI Marked with copper absorber & 50mm insulation of rockwood at back and 25mm on sides with 100mm Aluminium box with 1 nox toughned glass 3,2mm with 92% transmittance and Solar hot Water Storage Tank 200Litres SS 304 (1mm Thick) covered with 50mm PUF insulation and cladded with colour coated GI 0.4mm with 1x2kw electrical backup with suitable 3 cored cable as required and thermostat with 1no. Makeup Tank SS 304 withfloat valve and necessary hose pipe between collector & Hot waterTank system fixed over on Ms angle iron 40x40x5mm including nuts bolts, grouted in PCC 1:2:4 type B-1 blocks (30cmx30cmx30cm) and two coats of painting over coat of red oxide, brass gate valve in hot & cold water pipes complete all as specified & as directed. Note (i) Cost of PVC Tank, Cold & Hot water pipe with their fitting & water taps shell be measured and paid for separately (ii) Ms Angle structure shall be prepared as per manufacturer’s instruction
EXTERNAL ELECTRIC SUPPLY & LIGHTENING PROTECTION WORKS Supplying, laying, jointing, testing and commisioning HT 11 KV (E) XLPE cable, insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, size 3 core & cross section area 95 Sqmm, laid in trenches/pipes/ducts/along poles/walls/ equipment etc complete all specified and directed. NOTE:(i) All the cable shall be embossed with year of manufacturing, meterage at every metre in addition to its own standard makings as per IS i.e. Size, voltage etc. Cable shall be tested at FACTORY PREMISES before dispatch in presence of Rep of AO . (ii) Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the schedule
Supply/Laying / fixing, jointing, testing and commissioning, LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete all as specified and directed of following sizes:-.
2 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 120 Sqmm
3.5 Core 240 Sqmm
3.5 Core 300 Sqmm Note :- Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the schedule. (ii) cable length exceeding one drum length (exceeding 500 RM length) shall be tested at FACTORY PREMISES before dispatch in presence of Rep of AO
Dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
Supply and fix cable jointing kit, for 11 KV (earthed) grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumminum conductor cable of size 95 sqmm complete all as specified and directed.
Unreinforced precast concrete cable cover,ISI Marked IS-5820 (Latest Edition) class HV, Type 1, flat, size 300mm x 180mm x 40mm for protection of HT cable complete all as specified and as directed.
Supply and laying Sub class ‘B’ old size bricks laid adjacent to each other perpendicular to the direction of cable in trenches for protection of cable all as specified and directed.
M & L Cable rout indicater shown “ HT U/G cable HT/LT Cables” and root of cable with aero made of CI in suitable elliptical shape and fixed in MS rod 12 mm dia 70 cm long (all word embossed) and embaded in PCC block of size 30 x 30 x 60 cm in ground complete all as specified and directed.
Supply, transporting to site, erecting and fixing in truly verticle position, steel tubular swaged pole, type 410-SP-55 (11 metre long) complete finial taper plug, bolts, nuts, scerws as specified, CI base plate including drilling holes and painting with two coats of aluminium paint externally, providing 30cm wide alternate strips with white and black synthetic enamal paint upto 1.2m height from ground level and numbering the pole (with black and white paint), undergruound part of the pole shall be painted with black bituminous paint complete all as specified and directed. Note: Excavation, earthwork, PCC foundation shall be measured and paid separately.
Supply, transporting to site, erecting and fixing in truly verticle position, steel tubular swaged pole, type 410-SP-31 (9 meter long) complete finial taper plug, bolts, nuts, scerws as specified, CI base plate including drilling holes and painting with two coats of aluminium paint externally, providing 30cm wide alternate strips with white and black synthetic enamal paint upto 1.2m height from ground level and numbering the pole (with black and white paint), undergruound part of the pole shall be painted with black bituminous paint complete all as specified and directed. Note: Excavation, earthwork, PCC foundation shall be measured and paid separately.
Supply and fixing Junction box of size 200x160x95mm of any other Polycarbonate/polycarbonate with glass fiber re-inforced material higher size (pol mounting) and should be insulated and made out of polycarbonate with glass fiber reinforced material having IP-65 protection in accordance with IEC 60529, fixing with and including clamp made out of Ms flat iron size 25x3mm clamp made out of SS-304 and nuts bolts made out of SS 304. No hole to be made in the box to fix the clamp to insure IP 66 including suitable size of nuts, bolts and washers including painting to MS clamp and nut bolts with 2 coats of aluminium paint over a coat of red oxide complete comprising of the function and as directed. Note ; (a) Junction box must meet the provision laid down in IEC 60998-1, IEC—60670-22, IEC-60670-2 to 5 and colour according to RAL 9011/RAL7035 (b) The manufacturer of junction box shall submit a copy of IEC certificate. (c) Junction box shall be fire retardant self extinguishing in accordance with IEC 60695-2 to 11. DIN VDE 0304 part-3 UL 94 V2 flamability standard. It should be tested at glove wire test for 9600C (d) The degree of protection of enclosure against mechanical load shall be in accordance with EN 50298 for IK 08. (e)Internally embedded gasket of polyurethane/extruded silicon. (f) Junction box shall 4 pole complete with single pole MCB with C curve of 6Amp rating.
Supply and fixing LED street light fitting 60 watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant toughened glass cover complete with driver, lamp multiple optics complete with IP 65/66 protection complete. Note (i) Lumen output greater than 110 lumen per watt with SPD”. (ii) Make of Driver and luminaries shall be same (iii) Manufacturer should have in-house NABL accreted Lab for testing and certification of the same shall be submitted to GE before approval of the material.
Supply and fix LED post tap lantern copper dust painted cast aluminium spigot, spun aluminium canopy with clear acrylic cover light fitting including 15 watt LED lamp or strip and suitable dia of GI pipe for mounting the fitting prewired complete with all accessories.
Supply and fix PVC insulated and PVC Round Sheathed, 2 core 2.5 Sqmm Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 for connection from looping box to street light fitting complete all as specified and as directed.
Supply, fixing, testing and commissioning of air break gang operated switch triple pole mechanically operated outdoor type with all fittings/accessories mounted on and incl 11 KV HT porecain insulator and steel channel frame, GI operated rod 25 mm dia of suitable length with operating mechanism worked from ground level with dropout fuse consisting of 12 Nos insulators ISI marked, horizontal or vertically operated incl locking arrangement for operating handle with and including 7 lever lock with three Keys complete suitable for current rating of upto 200Amps HT 11 KV working pressure complete all as specified and as directed.
Supply and fixing HT lightening arrestors,non resistance type for out door use complete with all fittings and fixing arrangement such as brackets, clamps, nuts, washers and connecting to earth wire 4 mm dia GI wire, transmission class discharge capacity 65 KA, suitable for 11000 Volts, 3-phase, complete all as specied and directed.
LT PANEL Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK) of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, pedestal mounted front and back openable, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 01 No bus bar chambers with insulated Copper bus bars 800 Amps rating installed on porcelain insulators and cable alley for cables. The panel shall be dust and vermin proof, IP 65 class protection and outer enclosure made out of 3.15mm thick CRCA MS sheet and angle iron 40x40x6mm thick frame work including four Nos of legs 60cm long each of 40x40x6mm thick angle iron and inner compartments made out of 2.0mm thick CRCA MS sheet, complete panel powder coated finish over one coat of red oxide primer, front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less thank 1.5sqmm. The scope of work includes the following:- INCOMING (a) Aluminium bus bar of rating 800 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set (b) MCCB four pole 315 Amp confirming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 36 KA at 415 V AC , 50 Hz complete - 01 No. OUTGOING (a) MCCB four pole 160 Amp confirming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete - 02 Nos.
LT PANEL Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK) of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, pedestal mounted front and back openable, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 01 No bus bar chambers with insulated Copper bus bars 400 Amps rating installed on porcelain insulators and cable alley for cables. The panel shall be dust and vermin proof, IP 65 class protection and outer enclosure made out of 3.15mm thick CRCA MS sheet and angle iron 40x40x6mm thick frame work including four Nos of legs 60cm long each of 40x40x6mm thick angle iron and inner compartments made out of 2.0mm thick CRCA MS sheet, complete panel powder coated finish over one coat of red oxide primer, front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 1.5sqmm. The scope of work includes the following:- INCOMING (a) Aluminium bus bar of rating 400 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set (b) MCCB four pole 160 Amp confirming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 36 KA at 415 V AC , 50 Hz complete - 01 No. OUTGOING (a) MCCB four pole 100 Amp confirming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete - 02 Nos.
LT PANEL Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK) of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, pedestal mounted front and back openable, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 01 No bus bar chambers with insulated Copper bus bars 400 Amps rating installed on porcelain insulators and cable alley for cables. The panel shall be dust and vermin proof, IP 65 class protection and outer enclosure made out of 3.15mm thick CRCA MS sheet and angle iron 40x40x6mm thick frame work including four Nos of legs 60cm long each of 40x40x6mm thick angle iron and inner compartments made out of 2.0mm thick CRCA MS sheet, complete panel powder coated finish over one coat of red oxide primer, front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 1.5sqmm. The scope of work includes the following:- INCOMING (a) Aluminium bus bar of rating 400 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set (b) MCCB four pole 160 Amp confirming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 36 KA at 415 V AC , 50 Hz complete - 01 No. OUTGOING (a) MCCB four pole 100 Amp confirming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete - 02 Nos.
LT PANEL Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK) of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, pedestal mounted front and back openable, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 01 No bus bar chambers with insulated Copper bus bars 200 Amps rating installed on porcelain insulators and cable alley for cables. The panel shall be dust and vermin proof, IP 65 class protection and outer enclosure made out of 3.15mm thick CRCA MS sheet and angle iron 40x40x6mm thick frame work including four Nos of legs 60cm long each of 40x40x6mm thick angle iron and inner compartments made out of 2.0mm thick CRCA MS sheet, complete panel powder coated finish over one coat of red oxide primer, front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement {including provn of 65mm Godrej (Freedom) lock with 2 keys}, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 1.5sqmm. The scope of work includes the following:- INCOMING (a) Copper bus bar of rating 200 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set (b) MCCB four pole 63 Amp confirming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete - 01 No. OUTGOING (a) MCB SPN 6-32 Amp and rupturing capacity 10 KA at 415 V AC , 50 Hz C Curve complete - 09 Nos.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (medium grade) GI pipe for protection of earthing lead, 20 mm bore (medium grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC 1:1.5:3 type A-1 reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part I (2009) complete all as specified and directed. NOTE : The unit rate includes for protecton pipe 15mm and GI earth wire 4mm from top of earth plate upto 7.50 metre above ground level.
Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron 32x6mm earth strip by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, medium grade 40mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. complete all as specified and directed. NOTE : 1. Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner. 2. Cost of 7.5m length of GI strip & GI protection pipe shall be deemed to be included in the rate of this item. Extra length shall be measured and paid for separately.
Test point terminal block made of gun metal or phosphorous bronze 75x75x25mm drilled and screwed including 04 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90x90x90mm made of 1.6mm CRCA sheet painted with two coats of synthetic enamel paint over a coat of red oxide primer, and screwed to wall for protection of test point complete complete all as specified and as directed.
EOT-CRANE Design, supply, errecting, testing and commissioning of electrically operated over head traveling crane 2 MT capacity double girder type class-II with necessary steel structure track rails for LT & CT, electric motors and gear driven, long, cross travel/hoisting mechanism, W V F control drives for normal and micro speed control, operated from floor with pendent push button controls as well as by radio frequency remote controller, movable, independent of crab position including provision of track rail/square bar for a bay length 24 mtr approx for long travel with 4 Nos busbars 415 volts, 3 phase, 40 Amp rating confirming to relevant IS PVC coated DSL shrouded system with its accessories, including current collector, supporting brackets, insulators and other standard fixtures and fittings carriage with double flanged cylindrical wheels, standard hook black, steel wire rope, service platform, ladder, suitable brakes for all motions flexible trailing cable system for complete length with all standard fittings and fixtures, buffers including all safety devices and interlocking, panel fabricated from 1.6mm MS Sheet duly powder coated with WVF drives for all the three motions with main incoming breaker/switches, transformer, contactor etc alonwith MCBs in the control circuit of each motion and each break circuit shall be provided with suitable contactor, all wiring with suitable size copper conductor cable. The crane shall be painted with one coat of red oxide and two coats of epoxy paint and shall meet the following requirment conforming to IS:3177, IS-807 and IS-800 complete all as specified and directed for following parameters:- (i) Cross span : 14.5 m + 5% (ii) Long span : 24 m + 5% (iii) Class of duty : Class-II (indoor) Crane
EOT-CRANE (Contd....) (iv) Location : Indoor (v) Controls : From floor level through pendent push button (vi) Height of lift : 7.50 m (approx) (vii) Hook height : 7.0 m (approx) (viii) LT motor : Twin drive of suitable capacity each with gear box (ix) CT motor : of suitable capacity (x) Hoisting motor : of suitable capacity(xi) Long travel speed : 10 metre/minute with 20% micro speed arrangement on it (approx) (xii) Main Hoisting speed : 0.3 metre/minute(as recommended by Manufacturer) with 10% micro speed arrangement on it (approx) (xiii) Creep Hoisting speed : 4 metre/minute (xiv) Cross travel speed :10 metre/minute with 10% micro speed arrangement on it (approx) (xv) Operation : Pendent push button switch from floor (xvi) Power supply : 415 volts 3 phase (xvii) Speed control of Hoist motor shall be through VVVFD. (xviii) Anti collision device NOTES:- (i) Cranes shall be operated of by means of pendent push buttons from floor level with protective panel independently with inter locking arrangement. (ii) Pendent push button along with required cable shall be provided can be in the cable pendent post control are required to be provided the cable control shall have push button for stop and hold at the locations. (iii) FLP limit switches at end point shall be provided
EOT-CRANE Design, supply, errecting, testing and commissioning of electrically operated over head traveling crane 5 MT capacity double girder type class-II with necessary steel structure track rails for LT & CT, electric motors and gear driven, long, cross travel/hoisting mechanism, W V F control drives for normal and micro speed control, operated from floor with pendent push button controls as well as by radio frequency remote controller, movable, independent of crab position including provision of track rail/square bar for a bay length 19 mtr approx for long travel with 4 Nos busbars 415 volts, 3 phase, 40 Amp rating confirming to relevant IS PVC coated DSL shrouded system with its accessories, including current collector, supporting brackets, insulators and other standard fixtures and fittings carriage with double flanged cylindrical wheels, standard hook black, steel wire rope, service platform, ladder, suitable brakes for all motions flexible trailing cable system for complete length with all standard fittings and fixtures, buffers including all safety devices and interlocking, panel fabricated from 1.6mm MS Sheet duly powder coated with WVF drives for all the three motions with main incoming breaker/switches, transformer, contactor etc alonwith MCBs in the control circuit of each motion and each break circuit shall be provided with suitable contactor, all wiring with suitable size copper conductor cable. The crane shall be painted with one coat of red oxide and two coats of epoxy paint and shall meet the following requirment conforming to IS:3177, IS-807 and IS-800 complete all as specified and directed for following parameters:- (i) Cross span : 7.5 m + 5% (ii) Long span : 19 m + 5% (iii) Class of duty : Class-II (indoor) Crane
EOT-CRANE (Contd....) (iv) Location : Indoor (v) Controls : From floor level through pendent push button as well as by radio frequency remote controller (vi) Height of lift : 12.0 m (approx) (vii) Hook height : 12.0 m (approx) (viii) LT motor : Twin drive of suitable capacity each with gear box (ix) CT motor : of suitable capacity (x) Hoisting motor : of suitable capacity (xi) Long travel speed : 10 metre/minute with 20% micro speed arrangement on it (approx) (xii) Main Hoisting speed : 03 metre/minute with 10% micro speed arrangement on it (approx) (xiii) Creep Hoisting speed : 4 metre/minute (xiv) Cross travel speed :10, 0.30 Meter/minute” (as recommended by manufacturer) with 10% micro speed arrangement on it (approx) (xv) Power supply : 415 volts 3 phase (xvi) Speed control of Hoist motor shall be through VVVFD. (xvii) Anti collision device NOTES:- (i) Cranes shall be operated of by means of pendent push buttons from floor level with protective panel independently with inter locking arrangement. (ii) Pendent push button along with required cable shall be provided can be in the cable pendent post control are required to be provided the cable control shall have push button for stop and hold at the locations. (iii) FLP limit switches at end point shall be provided.
Supply installation commissioning and testing of Refrigerators frost free five star rating electric driven (single phase) of capacity 324 litres or nearest higher capacity as approved by GE complete all as specified and directed.
Supply installation commissioning and testing of hard top Deep freezer single phase 240 Volts 50 HZs of capacity 320 litres or nearest higher capacity as approved by GE complete all as specified and directed.
Supply, installation,testing and commissioning of self standing Water cooler fully stainless steel,puff insulated body, electric driven single phase 230 Volts, 50 Hz having storage capacity of 80 Ltrs and nominal cooling capacity of 40 Ltrs per hour with reciprocating compressor, eco friendley R-134A refrigernt, externally mounted thermostat for easy regulating temperature with extra large stainless steel water tray for fast drainage of water complete all as specified and as directed.
Supply, installation,testing and commissioning Desert Air cooler, electric driven copper wound fan motor and submersible pump single phase having having nominal air flow capacity of 4000 Cum per hour factory made out of 1.0mm thick (20 Gauge) MS sheet powder coated, electric driven capacity 170 watt, 230V (single phase ), having approx storage capacity of 80 Ltrs with MS fabricated stand made out of 40 x 40 x 5mm angle frame duly grouted in wall, painted with 2 coats of synethetic enamel paint over a coat of red oxide with PVC float valve 15mm dia, overall outer size not lessthan 66cmx66cmx99cm(Height) complete all as specified and as directed. Note-MS angle iron stand shall be measured and paid separately under respective item(s)
Supply, installation,testing and commissioning voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input varriation between 170 V to 290 V with output voltage stablized at 230 V with accuracy of + 2.5% and of capacity 1.0 KVA complete all as specified and as directed.
Supply, installation,testing and commissioning voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input varriation between 170 V to 290 V with output voltage stablized at 230 V with accuracy of + 2.5% and of capacity 3.0 KVA complete all as specified and as directed.
Supply, installation,testing and commissioning voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input varriation between 170 V to 290 V with output voltage stablized at 230 V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and as directed.
RAIN WATER HARVESTING WORKS Drilling pilot bore hole of 150mm dia by rotary drilling method (Direct/ reverse) through rig machine for injection well in any kind of soil strate or rock including disposal of surplus soil/rock to a distace not exceeding 50 metre complete all as specified including deploying required rig machinery. T&P equipment etc complete inclduing transporting of all materials like rig machine, tool and plants, collection of logsamples (drilling/ cutting) and to maintain drill time log book all as specified and directed
Supply, assembling, jointing lowering and fixing in postion PVC plain casing pipe, heavy duty of size 150mm bore with a thickness 7.5 to 8.5mm conforming to IS- 4985 having male threads at spigot end and female threads at socket end screwed and socket type in all jointing accessories complete all as specified and as directed.
Supply assemnling, jointing, lower and fixing in position PVC screen casing pipe, heavy duty of size 150mm, wall thickness 7.5 to 8.5 mm conforming ti S-4985 having ale threads at spigot and female threads at socket endscrewed and pocket type in all jointing accessories complete all as specified and as directed.
PVC bail plug assembly suitable for 150 mm nominal bore PVC casing pipe internally threaded and jointed with casing pipe complete all as specied and as directed
Mild steel hosing clamp, made out of 12mm thick MS flat bend to shape for 150mm bore casing pipe with necessary bolts. Nuts and washers at ground level complete all as specified and as directed
PVC well borewell cap 8 mm thick, suitable for 150mm bore having internal threads complete all as specifed and as directed
Development of injection bore well by using air compressor of suitable capacity of removing the drilling mud and finer sediments in the surrounding of borewell screens complete all as specifed and as directed (5 hours for each well)
Supply and packing pea gravel of size 2 mm to 5 mm all around casing pipe and slotted pipe complete all as specified and as directed
Loose filling with aggregates of broken stone or boulders of gauge 20 to 40 mm in soakage pits, soakage well and in other similar situation complete all as specified and as directed.
Supply and laying/fixing in position 150mm bore UPVC pipe (SCH-40) including all jointing accessories complete all as specified and as directed.
Supply and laying/fixing in position 200mm bore UPVC pipe (SCH-40) including all jointing accessories complete all as specified and as directed.
PVC cross of size 150 mm dia with 100 mm dia branches heavy duty having internal threads complete all as specified and directed.
PVC screened collector pipe having slot of 1.5 mm size heavy duty of size 100 mm dia complete all as specified and directed
ARBORICULTURE WORKS Digging holes in soft /loose soil and refiling the same with mixture of clean earth mixed with manure/ cow dung in ratio of 2:1 including watering , dressing, levelling etc complete all as specified & directed for following :-
100 cm dia and 100 cm deep
60 cm dia and 60 am deep
Plantation of Neem, Mango, Peepal, Bargad, Jamum, kikar, sheesham, Guava, Sangwan tree including preparation of Plant Bed incl mauring and watering complete all as directed.
Plantation of Lemon, Orange & the like Trees including preparation of Plant Bed incl mauring and watering complete all as directed.
Supply only DAP fertilizer of approved quality complete all as directed..
Supply only Urea fertilizer of approved quality complete all as directed..
DEMOLITION WORKS Dismantling of Concertina coil of any description and size complete all as specified and directed.
Dismantling of barbed wire of any description complete all as specified and directed.
Point wiring for flame light fitting using approved colour coding as per IS, with stranded conductor 1.5 Sq mm (normal area). Single core, flame retardant low smoke (FRLS). PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked Tec and FIA approved in and including heavy duty steel conduct and its fittings, ISI marked, mild steel sunken boxes (Terminal boxes) with earth dolly, duty painted internally & externally with two coats of anti-corrosive paint over a coat of red oxide primer, covered with 3mm thick hylem sheet including flame retardant low smoke (FRLS), PVC insulated unsheathed stranded copper conductor 1.5sqmm (normal area) single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified.
Note: For the purpose of arriving at lumpsum amount, the amount of credit sch for buildings and other services i.e Sch 'A' section XVI (i.e Rs 6225.00) shall be deducted from the total amount arrived.
A.S. CONSTRUCTION CO.
SAR AGENCIES
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
SOM BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid