| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹47.1 L+₹2.2 L (4.92%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹47.4 L+₹2.5 L (5.60%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹48.0 L+₹3.2 L (7.02%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹48.1 L+₹3.2 L (7.10%)Rejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
20 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I NAVY JAMNAGAR
INS NAVY VALSURA JAMNAGAR 361150
ADDITION/ ALTERATION AND IMPROVEMENT TO BLDG No P14 UNDER GE I NAVY JAMNAGAR
2022_MES_533762_1
8611
Open Tender
Civil Works - Others
Item Rate
180 days
GE I NAVY JAMNAGAR
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹49,000
Yes
14 Feb 2023
27 Jun 2022
22 Jul 2022
27 Jun 2022
20 Jul 2022
15 Jul 2022
27 Jun 2022 - 14 Jul 2022
60 days
Amount
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MD land complete all as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MD land complete all as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for and removal of entire debris as ordered outside MD land complete all as directed.
Demolition of reinforced cement concrete of any description and in any position including removal of entire debris as ordered outside MD land complete all as directed.
Dismantling floor, hearth or wall tiling inluding cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MD land complete all as directed.
Dismantling wrough iron or mild steel work of any description not other wise provided for and stacking at site complete all as directed.
Demolition and breaking up 100mm bore AC/ Concrete pipe set in cement mortar including removal and depositing of debris to a distance not exc 50 mts and depositing where directed.
Dismantling of CI or reinforced cocrete drain pipes joint in cement mortar including removal and depositing of debris to a distance not exc 50 mts and depositing where directed.
Dismantling of AC Corrugated or semi corrugated sheet etc any thickness including ridges as in roof covering and stacking at site where directed and removal of debris to a outside MOD land and depositing where directed complete all as directed.
Dismantling fencing wire mesh any type etc complete all as specified.
Dismantling post or struts (wood, steel or RCC) any section, including taking out embedded portion in concrete and making good the disturbed ground complete all as specified and as directed.
Taking down chowkats or frames not exc 1.5 sqm each with shutters (without taking off shutters from frame) and stacking at site where directed.
All as per item 12 here-in-above, but exceeding 1.5 Sqm but not exceeding 4 Sqm each
Excavating post holes or similar holes, each not exceeding 0.5 Cum getting out in hard/ dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50 mtr as directed etc complete.
Excavation in trenches and not exe. 1.5 m wide and not exe. 1.5 m in depth for foundation of drain, man hole, laying of cables, stay etc. not exe. 10 Sq. m on plan and not exe. 1.5 m depth and getting out in soft/ loose soil.
Excavation in trenches and not exe. 1.5 m wide and not exe. 1.5 m in depth for foundation of drain, man hole, laying of cables, stay etc. not exe. 10 Sq. m on plan and not exe. 1.5 m depth and getting out in Hard/ dense soil.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed .at a level not exceeding 1.5 M above the starting point complete all as directed.
Removing excavated surplus soil to a distance exceeding 50m but not exc 250m and depositing where directed .at a level not exceeding 1.5 M above the starting point complete all as directed.
M & L for Moorum / red bajri filling under floors or in foundation etc including spreading levelling , watering and well ramming in layers not exc . 15 cm thick complete all as specified and directed.(Note i): Moorum brought from out side MD land . ii) Measurements shall be taken after compaction).
M&L broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.
M&L for providing and injecting chemical emulsion Anti Termite Treatment of soil under existing floors using chemical emulsion at the rate of One liter per hole, 300 mm apart including drilling and plugging 12 mm dia., holes with cement mortar 1:2 to match the existing floors complete all as specified.
M&L for providing and injecting chemical emulsion for post construction Anti Termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate of 0.50 litres per hole by drilling 6 mm dia., holes at a down ward angle of 45 degree at 150 mm centre to centre and sealing the same to match with the existing finish complete all as specifid.
M&L for providing and injecting chemical emulsion for post construction Anti Termite Treatment along the external/ internal wall below concrete or masonry apron using chemical emulsion @2.25 litres per linear metre including 12mm dia upto 300mm deep and 300mm centre to centre and plugging holes in CM1:2 complete all as specifid.
M&L for PCC 1:4:8, type D2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete for steel pole complete all as specified.
M&L for PCC 1:2:4, type B2 using 40 mm graded crushed stone aggregate as in foundation filling mass concrete complete all as specified and directed
M&L for plain cement concrete 1:2:4 type B0 (using 12.5 mm graded granite stone aggregate) as in padding concrete to the roof slab of average thickness of 30 mm thick complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B1 using 20 mm graded granite stone aggregate as in cast in situ in cills and other similar bands, plinth courses, coping, padding and roof kerb including necessary form work, weathering slightly rounded, chamfered angles and throating complete all as specified and directed.
Providing precast cement concrete Type B1 1:2:4 using 20 mm graded crushed stone aggregate as in landings, kitchen shelves, manhole cover, Chajjas etc. and similar articles with plain faces and set in cement mortar 1:4 complete all as directed.
M&L factory made pre cast PCC 1:3:6, type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified.
M&L factory made pre cast PCC 1:3:6 type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks or slabs, 10 cm thick (plain or interlocking joints) and setting in CM 1:4 complete all as specified.
M&L for Reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate in lintels over 1.5m clear spans complete all as specified and directed.
M&L RCC M-30 ( using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, canopies, deck slab etc complete all as directed. .Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 (using 20 mm graded granite stone aggregate) as in chajja complete all as directed. Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 (using 20 mm graded granite stone aggregate) as in beams, cantilevers, bressummers lintels over 1.5m span complete all as directed.. Note: Reinforcement shall be measured and paid separately.
Cutting holes in brick works of size not exc half brick built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required including making good as per its original specification with out any extra cost complete all as directed.
Cutting chases in brick/ stone wall, pinning in, making good to facing where required and plastering in CM 1:4 to ends of edges of landing, steps, cills, lintels etc and cutting chases not exceeding 10 cm girth for concealed water tubing and making good cutting as per its original specfication complete all as directed.
Supply only Integral Water Proofing Compound (ISI Marked) complete. Make: CICO, Acco Proof, Impermo, Aqua flex as approved.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping), flat rough finished surface all as specified.
Formwork to chullah hoods, chajjas, troughs and similar items including edges, flat rough finished surface all as specified.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. flat rough finished surface all as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 10cm but n exc 20cm thick slab for flat rough finished surface all as specified.
S&F Second class hard wood factory made kiln - seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as directed.
S&F 35 mm thick second class hard wood factory made plain framed panelled door shutter (any number of panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12mm thick veneered particle boards with commercial veneering on both face the size of rail and style as per IS - 1003 (Part I) kiln seasoned and chemically pressure treated and fixed to chowkats complete all as directed.
S &F 35 mm thick second class hard wood factory made glazed and skeleton shutter open rebated and prepared to receive glass, guage etc edge of framing plain chamfered or rounded fitted with cut and mitred beads for securing guage etc size of members of shutter as specified in SSR Part I Section 8 clause 8.24 (a) supplied and fitted to chowkats.
S&F 35 mm thick flush shutter with solid core construction with block board core and plywood face panels, commercial type on both sides including exposed surfaces finished with external teak wood lipping, 6mm thick fixed with nails and both side 0.90mm thick Decorative laminate type 1 of surface finish, colour and pattern and approved, fixed with approved adhesive as per manufacture's instructions complete all as directed.
S&F 18/19 mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balacing white lamination, fixed with screws to timber frame work as in palmet, almirah complete all as directed.
S&F fibre glass reinforced plastic (FRP) door frames of three legged of cross section 90x45 mm having single rebate 32x15 mm to receive shutter of 30 mm thickness. The laminate door frame moulded with fire retardant grade unsaturated polyster resin and chopped mat. Door frame laminate of 2 mm thick and filled with suitable wooden block in all three legs. The frame shall be covered with fibre glass from all sides. Mild steel stay shall be provided at the bottom to steady the frame.
S&F 30 mm thick fibre glass reinforced plastic (FRP) paneled door shutter made with fire retardant grade unsaturated polyester resin moulded to 3 mm thick FRP laminated for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5 mm thick FRP laminated for panels.
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frames for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as directed.
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutter, side hung type without sash bar, aluminium section weighting 0.55 kg/m including necessary jointing cleats, louvers, glazing clips, rubber packing anodized aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos.), suitable handle (2 Nos.) etc. complete all as directed. Note: Glass shall be measured and paid seperately.
S&F aluminium anodised DECO grill 10mm thick DG 104 not less than 3.97Kg/Sqm fixed with necessary H/F/H channel etc complete all as specified and directed. (DECO grill fixed with windows with all fittings complete all as directed.)
S&F aluminium alloy wire mesh, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples.
S&F 200 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
S&F 150mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
S&F 75 mm size butt hinges, medium weight cold rolled mild steel and fixed .
S&F 100 mm size stainless steel butt hinges, medium weight.
S&F 100 mm size aluminium alloy handles (ISI Marked) fabricated type anodised and fixed.
S&F 150 mm size aluminium alloy handles (ISI Marked) fabricated type anodised and fixed.
S&F 300 mm long aluminium alloy, anodised sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clip of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
S&F 300 mm size mild steel ordinary rat tail rod pattern springs in-cluding roller and roller plate complete all as directed.
S&F 75mm door stopper of aluminium alloy body with rubber bottom fixed with screw in bottom rail of door complete as specified.
S&F 100 mm hasp and staple, safety type of aluminium, anodised, including bolts to hinge type, fixed with screws complete all as specified.
S&F 20 mm dia stainless steel curtain rails with pair of knob brackets fixed with screws complete all as directed
S&F mild steel hold fasts of flats iron 25x5mm confirming to Fe 410-O or Fe 310-O and similar items.
M&L framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
S&F 8 mm dia deformed TMT bars as in reinforcement, cut to length bent to shape required cranking including bending, hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S&F 10 mm dia and over TMT bars cut to length bent to shape required cranking including bending, hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No. 68 here-in-above but 5mm dia and over upto 10mm dia as in stirrups -do-
M&L MS round bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending, painted with one coat of aluminium paint over a coat of primer and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as directed.
Supply only MS galvanized chain link fencing (120 to 140 gms) 4mm dia and 75mm spacing and weighing not less than 2.75 kg/sqm diagonally pinned including line wire rails, straining bolts and provision of binding wire complete all as specified and as directed. Make : M/s Sachin , TATA or any approved make as approved.
Fixing only diagonally pinned fencing wire including line wire, any mesh size and type of standards, rails, straining bolts etc. including provision of binding wire complete all as directed.
S&F mild steel screw bolts of 10 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5 cm but not exceeding 10 cm long complete all as specified.
S&F mild steel work in posts and struts in fencing and FI fillets for securing fencing cut to shape as directed, including all necessary drilling, bolting or riverting etc, and similar items confirming to Fe-290 Gde E-165.
S&F pre-painted galvalume (zincalume) aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ ridges/ cladding to walls fixed with self tapping screws as specified.
Material and labour for removal of existing WPT course or any other kind of treatment surface over roof slab and cleaning of surface with wire brushes and water removing of unsolvent materials and depositing of the same outside MoD land and provide 15 mm thick screed bed/ bedding layer in CM 1:4 mixed with Water Proofing Compound (WPC) as per manufacturer instructions, including finishing the surface fair and even on RCC roof/ parapet once bedding layer of concrete is completely dried and apply a coat of oil based biumen primer @0.20kg/sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyster matt weighing not less than 160 gms/Sqm including minimum 10 cm side over laps and 15 cm end lap torch (longitudnial strength not less than 650n/sqcm) sealed and bonded as per manufacturer's instructions and as directed and finally finished the entire exposed top surface with one coats of solar reflective bituminious paint complete all as specified and as directed. Note: (i) The quoted rate is deemed to be inclusive of taking down & removal of debris , 15 mm thick 1:4 screed & complete APP treatment. (ii) WPC will be paid seperately (iii) The work shall be carried out only through manufacturer or their authorised applicator only and a written guarantee for work carried out shall be submitted by the manufacturer for the effectiveness of WPT (iv) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
M &L for cutting out cracks to 'V' section in existing roofs or terrace cleaning out, wetting, grouting with cement and sand slurry1:3 all as specified.
M&L for 25mm avg thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) for levelling the undulated floor after dismantling complete all as directed.
M&L 40 mm thick PCC 1:2:4, type B1 (using 20 mm graded crushed granite stone aggregate) as in sub base, floors, pavings etc. finished fair and even complete all as specified.
M&L 100 mm thick PCC 1:4:8, type D2 (using 40 mm graded crushed granite stone aggregate) as in sub base, floors, pavings etc. finished fair and even complete all as specified.
M&L for 75 mm thick plain cement conctere 1:3:6, type C1 using 20 mm graded crushed stone aggregate as in plinth protection, hard standing finished the surface even and smooth using extra cement complete all as directed.
M&L rectified jointless vetrified ceramic tiles 8-9mm thick (square/ rectangular) double charged/ ultra charged area of each tile exc 0.18 sqm but n exc 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as directed and as specified.
M&L for vetrified ceramic tiles 8-9mm thick (square/ rectangular), area of each tile exc 0.18 sqm but n exc 0.38 sqm, in skirting etc. tiles over and including 10 mm thick rendering in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match as in skirting complete all directed.
M & L non-skid coloured ceramic tiles 300x300x7 to 8 mm thick (square/ rectangular), in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all directed and specified.
All as per item No. 84 here-in-above, but size of tiles 400x400x7 to 8mm thick.
M&L glazed ceramic designer tiles any shade or pattern as approved of size 600x300x7 mm thick, on verticals surfaces, set and jointed in neat cement slurry including 10 mm thick back coat in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all directed. (Note for item Nos 82 to 86 : i) Quoted rate is deemed to be inclusive of cement screed. ii) Shade / pattern / Colour of tiles shall be got appproved before procurement).
S & F Granite 18-20 mm thick (of any type) work (table rubbed and polished) in steps, cills, raiser, under wash basins, platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using pigment to match with shade of granite laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all directed and specified. (Note: Quoted rate is deemed to be inclusive of Screed bed)
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as directed.
M&L Machine pressed coloured chequered cement concrete tiles (PVC moulded) of size 300x300x25 mm thick (confirming to IS: 13801-1993 and shall contain ISI mark) machine pressed with grey cement and pigments, set and jointed in neat cement slurry in floors and pointed with coloured cement to match the shade and laying on 15 mm thick screed bed in CM 1:6 complete all as specified.(Note: i) Quoted rate is deemed to be inclusive of cement screed. ii) Colour of tiles shall be got appproved before incorporation in the work)
M&L for rendering 15 mm thick in CM 1:6 on brick/ block/ stone masonry surfaces other than fair faces of brick work with sagol finish and finished even and smooth without using extra cement complete all as specified.
M&L for rendering 10 mm thick in CM 1:6 on brick/ block/ stone masonry surfaces other than fair faces of brick work with sagol finish and finished even and smooth without using extra cement complete all as specified.
M&L for rendering 15 mm thick in cement mortar 1:4 on brick/ block/ stone masonry surfaces other than fair faces of brick work mixed with WPC as per manufacturer instruction, and finished the surface fair and even complete all as specified and directed. (Note : WPC measured and paid separately).
M&L for rendering 10 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces on ceiling finished even and smooth without using extra cement complete all as specified.
M&L for rendering 5 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces on ceiling finished even and smooth without using extra cement complete all as specified.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections not exceeding 0.5 Sqm in each pane complete all as directed.
S&F 4mm thick figured glass, pin headed type and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane complete all as directed.
Three coats of white wash on newly plastered wall surface after necessary preparation of surface complete all as directed.
Three coats of white wash on newly plastered surface of ceiling after necessary preparation of surface complete all as directed.
M&L for preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick white cement based wall care putty complete all as specified.
M&L for preparing new plastered ceiling surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick white cement based wall care putty complete all as specified.
M&L for complete removal of existing treatment and preparing old plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over a coat of 1 mm thick white cement based wall care putty complete all as specified.
M&L for complete removal of existing treatment and preparing old plastered or unplastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of 1 mm thick white cement based wall care putty complete all as specified.
M&L preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L for preparation of old painted surfaces by complete removing the existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M&L for two coats of 1st quality synthetic enemal paint over a coat of zinc chromate primer over any description of new steel surface over 10 cm in width or girth including necessary preparation of new steel surface complete all as directed.
M&L for two coats of 1st quality synthetic enamel paint over a coat of pink primer on new wooden surface of any description over 10 cm in width or girth including necessary preparation of new wooden surface complete all as directed.
Taking down old 15 mm bore GI tubing and connection including cleaning for re fixing stacking at site where directed.
M&L for 15 mm bore steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as directed.
Fixing only 15 mm bore GI tube medium grade with all fittings all new (ISI Marked) fixed to wall and ceiling or laid in floors making necessary connection and testing complete
Taking down old 20 mm bore GI tubing and connection including cleaning for re fixing stacking at site where directed.
M&L for 20 mm bore steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as directed.
S&F in repairs Gun metal gate or gate valves with iron wheel head screwed box and both ends for iron pipe for 20 mm bore of pipe or union complete all as directed.
S&F Gun metal gate or gate valves with iron wheel head screwed box and both ends for iron pipe for 20 mm bore of pipe or union complete all as directed.
S&F in repairs 15 mm bore bib taps, fancy type long body with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as directed.
S&F 15 mm bore bib taps, fancy type long body with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as directed.
S&F two way bib taps with health faucet with 1.2m brass flexible tube of length as ordered and wall hook mounted type chromium plated for EWC.
S&F in repairs 15 mm bore stop valve fancy type, cast copper alloy, chromium plated, with long shank and cup (concealed type) screwed down high pressure with cruntch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified.
S&F in repairs 15 mm bore angle cock, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as directed.
S&F 15 mm bore angle cock, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as directed.
S&F in repairs 15 mm bore pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down highpressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as directed.
S&F 15 mm bore pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down highpressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as directed.
S&F in repairs brass chromium plated shower rose 125 mm dia with or wihout swivel joint, any size, including fixing to steel pipe or union.
S&F soap dish, fixed to tiled walls with plugs and chromium plated brass screws complete.
S&F in repairs Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as directed.
S&F Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as directed.
S&F in repairs towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/ plastic cleats (Minimum weight 90gms) complete all as directed. Make : Prayag or equivalent in approved make.
S&F in repairs sheet glass shelf assemble consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and ralling 60 cm long complete all as directed. Make : Prayag or equivalent in approved make.
S&F in repairs sinks without drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or cutting and fixing into granite platform including fixing cantilever brackets and connecting union to pipe overall size 495 x 420 mm bowl size 410mm x 330mm x 160mm complete all as directed .Make: Prayag or equivalent in approved make.
S&F in repair stainless steel plate rack of size 90 x 100cm with standard section etc fixed complete in position as complete all as directed .Make : Prayag Cat No. P-346 or equivalent in approved make.
S&F 50 mm bore low density polyethylene pipes (LDP) of pressure rating 6 kgf/cm2, laid in floors complete as directed.
S&F 100 mm bore spun pipe, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as directed.
All as per item No 133 here-in-above but fixed to walls -do-
S&F 75 mm bore spun pipe, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as directed.
All as per item No 135 here-in-above but fixed to walls -do-
S&F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as directed.
All as per item No 137 here-in-above but 75 mm bore bends -do-
S&F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval acess door complete all as directed.
All as per item No 139 here-in-above but 75 mm bore bends -do-
S&F 100 mm bore cast iron branch pieces, Y, tee, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval acess door complete all as directed.
All as per item No 141 here-in-above but 75 mm bore branch pieces -do-
S&F 100 mm bore cast iron branch vent cowl complete all as directed.
All as per item No 143 here -in -above but 75 mm bore branch vent cowl -do-
S&F 75 mm diameter of out let Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as directed.
S&F 110 mm bore PVC (SWR) pipes (type-B) single socketed in any length with rubber rings joints fixed to wall complete all as directed.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints fixed to wall complete all as directed.
S&F 110 mm bore size PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as directed.
S&F 110 mm bore size PVC (SWR) bends any radius including jointing the same with solvent cement complete all as directed.
S&F 75 mm bore size PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as directed.
S&F 110 mm bore size PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as directed.
S&F PVC (SWR) Vent cowl 110 mm bore size fixed complete all as directed.
M&L PVC (SWR) gully trap 125/110 mm including jonting the same with solvent cement complete all as directed.
S&F 100mm dia P or S trap complete all as directed.
S&F in repairs 550 mm x 400 mm size ( white) flat back, oval type vitreous china wash hand basin including cutting for and pinning ends of brackets or erecting stand, waste coupling & waste pipe complete all as directed.
S&F 550 mm x 400 mm size ( white) flat back, oval type vitreous china wash hand basin including cutting for and pinning ends of brackets or erecting stand, waste coupling & waste pipe complete all as directed.
S&F in repairs vitreous China ware wash down water closet pan (EWC), white with fixing bolt to floor and connecting pan to trap, pedestral pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc complete all as directed.
S&F vitreous China ware wash down water closet pan (EWC), white with fixing bolt to floor and connecting pan to trap, pedestral pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc complete all as directed.
S&F in repairs plastic water closet seat, white, closed pattern with flat bottom, cover and mild steel chromium plated or aluminised hinging device complete all as directed.
S&F plastic water closet seat, white, closed pattern with flat bottom, cover and mild steel chromium plated or aluminised hinging device complete all as directed.
S&F in repairs 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as directed.
S&F 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as directed.
S&F in repairs PVC connection 15mm bore and 45cm long with two Nos of brass check nuts and washers complete all as directed.
S&F PVC connection 15mm bore and 45cm long with two Nos of brass check nuts and washers complete all as directed.
S&F PVC waste pipe of suitable length for wash hand basin complete all as directed.
S&F 100 mm size PVC (SWR) multi floor trap with grating including jonting the same with solvent cement complete all as directed.
S&F 75 mm size PVC (SWR) multi floor trap with grating including jonting the same with solvent cement complete all as directed.
S&F 1000 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover including brass float valve high pressure suitable for 20 mm bore of pipe with polythene float, fixture hoisted and fixed in position where ordered and making necessary connection and testing complete all as directed.
Dismantling of existing any type & any capacity water storage tank fixed in any description and stacking at site and S&F new 500 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover including brass float valve high pressure suitable for 20 mm bore of pipe with polythene float, fixture hoisted and fixed in position where ordered and making necessary connection and testing complete all as directed.
M&L for concrete bed in PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregrate) to 150mm bore Hume pipe including packing and haunching completely surrondings of the pipe after they are laid and tested complete all as specified and directed. (Note: Hume pipe measured and paid seperately)
M&L for Reinforced concrete pipe 150mm bore Class NP2 (ISI Marked) alongwith collar laid to slope in trenches over PCC bed & jointed in cement mortar 1:3 and tested on completion complete all as specified and directed.
Cutting/ Chipping the spalling concrete surface of column, beams, slabs, chajjas, cantilever etc trimming, cleaning the surface to receive guniting/ plastering all as specified and directed.
M&L for applying epoxy treatment with Nitobond AR of Fosroc chemical or equivalent of Dr. Fixit or equivalent for bonding old demolished concrete surfaces and guniting including application of on coat of Nitozinc primer to the exposed reinforcement wherever required complete all as specified and directed by Engr-in-charge.
M&L for providing pressure guniting averaging 20mm thick in CM 1:3 to soffits of slabs, chajjas/ parapets by applying chemical prior to gunniting including providing double scaffolding as required and removal of same after use complete all as specified and directed by Engr-in-charge.
E&M Items: Taking, down carefully copper/ aluminium point wiring (Light, Fan, socket or power) complete (fittings such as switches, celling roses, pendants, regulators, sockets, DB's) etc all as specified and directed.
Taking down carefully unserviceable Main switch and DB's including wooden board and removing from site including making good disturbed surfaces of wall all as complete as specified and as directed.
M&L for point wiring with 1100 V, 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistranded passing through including heavy duty PVC casing, capping, double lock type, min 25 mm wide including sheet metal box, terminal plates suitable for modular switch, socket etc. with all accessories, concealed MS box / PVC modular box with cover and 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed.
All as per item No. 177 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as directed.
M&L for point wiring with 1100 V, 1.5 Sqmm single core PVC FRLS insulated unsheathed cable, copper conductor multistranded passing through including PVC concealed conduit 20mm, concealed MS box/ PVC/ MS/ Cast Iron box and logic modular whtie plates of suitable as required at site with PVC insulated unsheathed stranded copper of size 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed.
All as per item No. 179 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as directed.
All as per item No.179 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 179 here-in-above, but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 179 here-in-above, but size of cable 4 Sq.mm for AC Metal socket in independent board with earth wire 4 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
S&F in repairs Modular switch 1 way 6 Amps,1 module all as specified and direced.
S&F in repairs Modular switch 1 way 16 Amps,1 module all as specified and direced.
S&F in repairs Modular Socket 6A -2/3 pin combinaed 2 Module all as specified and directed.
S&F in repairs Modular Socket 16A -2/3 pin combinaed 2 Module all as specified and directed.
S&F in repairs Modular Bell push 6 Amps, 1 module all as specified and directed.
S&F in repairs Bell Ding Dong AC 230 Volts, single pole/ Multi Music type.
S&F in repair Step type electronic fan regulator modular type 120W, 2 Module
S&F TV socket out let 1 module. Make: Legrand Cat Part No. 6755 46 or equivalent in Havells/ L&T/ ABB
S&F RJ 11 Telephone socket 1 module. Make: Legrand Cat part No. 6755 41 or equivalent in Havells/ L&T/ ABB
S&F in repairs Ceiling rose surface bakelite White/ Ivory/ Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
M&L for metal fluh boxes concealed for mounting concealed for mounting TV/ Telephone socket etc including logic modular plates and surrounds of suitable size complete all as directed. Make: Legrand Cat No. 6890 60 or equivalent in Havells/ L&T/ ABB
S&F Rigid non-metallic PVC conduit exclusive of boxes ( junction/ terminal) but inclusive all tees, bends, elbows, reducers and fixing accessories such as couplers lock nut saddles pipe hooks etc complete siz of 20mm.
Taking down existing light fittings fixed in any description and S&F new LED 4' Glaze LED Batten high quality design aluminium extruded with decorative end caps light fitting and fixed as per manufacturer's instruction complete all as specified and directed. Make: Jaguar Cat No. LGLZ01X024XC 24W or equivelant in Wipro/ Havells/ Bajaj
Taking down existing light fittings fixed in any description and S&F new LED 2' Glaze LED Batten high quality design aluminium extruded with decorative end caps light fitting and fixed as per manufacturer's instructions complete all as specified and as directed. Make: Jaguar Cat No. LGLZ01X010XC 10W CCT: 6500 or euivalent in Wipro/Havells/bajaj
S&F LED 45W security light/ street light fitting in aluminium pressure die cast housing with glass cover & lens IP 65 CCT(k) 3000 fixed over 32 mm bore GI light grade bracket of size not less than 1.2 Mts long fixed to wall with GI clamps, making connections & testing on completion to the satisfaction of Engineer-in-charge. Make: Jaguar Cat No. LSRT01S045XW or equivalent in Wipro/ Havells/ Bajaj. (Note: Quoted rate is deemed to be inclusive of GI bracket)
S&F BEE 5 Star rating (BLDC) Brushlesh direct current motor Ceiling Fan 1200 mm sweep, 230 V, Air delivery 210 CFM complete down rod and 3 core 1.5 sqmm copper conductor cable from ceiling rose to fan complete with all accessories fixed as per manufacturers instructions & testing on completion to entire satisfaction of Engineer-in-charge including taking down old fan complete. Make: Havells Model No. Efficiencia Neo or equivalent in USHA/ Khaitan/ Crompton Greaves /Bajaj Note: Old ceiling fan shall be deposited in the AGE E/M store yard.
S&F BEE 3 Star rating Ceiling Fan 1200 mm sweep, 230 V complete, down rod and 3 core 1.5 sqmm copper conductor cable from ceiling rose to fan complete with all accessories fixed as per manufacturers instructions & testing on completion to entire satisfaction of Engineer-in-charge including taking down old fan complete. Make: Bajaj Sabse Tezz EE 03 1200mm White CF or equivalent in Havells/ USHA/ Khaitan/ Crompton Greaves Note: Old ceiling fan shall be deposited in the AGE E/M store yard.
S&F Ceiling Fan 1400 mm sweep, 230 V complete, down rod and 3 core 1.5 sqmm copper conductor cable from ceiling rose to fan complete with all accessories fixed as per manufacturers instructions & testing on completion to entire satisfaction of Engineer-in-charge including taking down old fan complete. Make: Bajaj Kessels 50 ISI 1400mm White C/F or equivalent in Havells/ USHA/ Khaitan/ Crompton Greaves Note: Old ceiling fan shall be deposited in the AGE E/M store yard.
S&F in repairs fan down rod made out of GI Pipe 20mm medium grade, 600mm in length duly cutting, drilling, threading including fixing, hook, rubber reel, nut bolt complete all as specified and as directed.
M&L for making arrangements for Fan hook of standard type as per SSR specification including cutting RCC slabs to the required depth upto existing MS bars tie up with new one and making good disturbed surfaces complete all as specified and as directed.
S&F 300mm sweep metal Body Exhaust Fans AC single phase 230/ 240 V of size including taking down existing exhaust fan complete all as directed by Engineer-in-Charge. Make: Bajaj Model No. Supreme Plus 300 mm 900 rpm Ind EX Fan or equivalent in USHA/ Khaitan/ Crompton Greaves/ Havells Note: Old exhaust fan shall be deposited in the AGE E/M store yard.
Taking down and refixing the same after repair work an electric geyser etc single phase all as specified and directed by Engr -in-Charge.
S&F in repair Single pole sheet metal enclosure with a two pin and earth plug and socket complete 240V with one single pole MCB 20 amp all as specified and directed by Engr-in-Charge
S&F sheet metal enclouser for DB'S in wall / Nitch when MCB's to be used Single pole and neutral, 12 way, Double door 240 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F in repairs MCB SPN 40 Amp 240 V 50 Hz AC supply, 10 kA. Make: Legrand Cat No. 4086 18 or equivalent of Havells / L&T / ABB
S&F in repairs MCB SP 6 to 32 amp, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 87 to 4085 95 / Havells / L&T / ABB
S&F in repairs copper conductor flexible cable size of 3 core, 1 sqmm from ceiling fan to ceiling rose complete all as directed.
M&L for taking down existing cable and fixing, testing, commissioning of new XLPE insulated, armoured heavy duty electric cables with aluminium conducter 1100 volts grade, cross sectional area 25 sqmm 4 core complete all as directed
Supply and Lay HDPE (High density polyethlene pipe) of pressure reting 6 Kg /cm 2 for protection of cable laid in trenches of Size 40 sqmm
Taking down and refixing the same after repair work an electric meter in poly carbonate body with LCD display in class single phase ISI marked of rating 10 to 60 Amps as per IS 13779 with optical port and box.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point, including taking down existing earthing complete all as specified including testing on completion.
SIBS CONTRACTOR
suvidhiconstruction
S t modi
M/s Balaji Enterprise
1R K Traders
Amar Constructions
rahil enterprise
M/s. Jayant G Rampariya
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .