| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹7.7 LAccepted-AOC 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L-1 | Accepted-AOC AOC | |
| 2 | L-2₹7.8 L+₹2,700 (0.35%)Rejected-Finance | L-2 | Rejected-Finance Highest | |
| 3 | L-3₹8.0 L+₹23,692 (3.06%)Rejected-Finance TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | L-3 | Rejected-Finance Highest |
Tender Value
₹9.0 L
EMD Value
₹17,980
Closing Date
22 Jul 2019, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Division PWD B and R Br., Ambala
Const. of New Judicial Court Complex, Shahabad, Distt. Kurukshetra (Pdg. Fire Alarm and PA System).
2019_HRY_85731_1
PWD/Elect-KNL/Elect-AMB/16123
Open Tender
Construction Works
Works
60 days
Ambala
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, Elect. Division PWD Band R Br.
₹17,980
19 Oct 2021
10 Jul 2019
24 Jul 2019
10 Jul 2019
22 Jul 2019
10 Jul 2019
Amount
SITC of Micro processor based 2 wire fault tolerant, networkable type fire alarm / detection control panel ( having nos. of 2 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character L C D unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work Makes : Bosch FPA 1000 Series ,Cerberus by Siemens, Edwards EST3,Honeywell Morley Zxe Series)
SITC of 6 watt speaker wall mount / ceiling (Make Honeywell/BOSCH/Henrich)
SITC of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) (Makes: Bosch FAP-440-T+FAA-440, Siemens Cerberus OH921+DB-11, Honeywell Morley MI-PTSE+B501, Edwards SIGA PHD + SIGA )
SITC ofaddressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) (Makes: Bosch FAH-440 + FAA-440 , Siemens Cerberus HI921+DB-11, Honeywell Morley MI-RHSE+B501 , Edwards SIGA DHI + SIGA )
SITC of Addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch / Morley / Siemens / Edwards
SITC of Exit Signage With Battery Backup Glow Type Size 285mm x 175mm , also as per requirement Material Acrylic, Aluminum, Aluminum Acrylic , Power Consumption 5 V / 220 mA (approx.) Feature With battery backup. rigid sheet signage containing Zink sulphate as bare chemical class 1 material PSPA fixed on 3mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. (Make: PE / Glolite / Pearl)
SITC of Intelligent Analog Addressable Type Monitor Modules having option of RAIL or Surface Mounting with Tri Color LED status indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switch from 01-99 dully approved to GEA GEW1-082 conforming to BS5839 Standards and Duly approved by EN54/LPCB/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work.(Make: Bosch / Morley / Siemens / Edwards
SITC of minimum 1000 Mtr. Range Kheraj / National make SIRON generator provided at the roof of the building with separate Power Supply, relay etc. complete the in all respect up to the entire satisfaction of Engineer-in-Charge of work.
Supply & Erection of Fire extinguisher all as Per IS 15683 duly hanged on the wall with necessary hooks to complete the job in all respect upto entire satisfaction of engineer incharge of work. Make: Safex / Minimax / cease fire) ABC dry Powder extinguisher 6 Kg Cap
Water/C2 type extinguisher 9 Ltr Cap
CO2 4.5kg capacity
SITC of fault isolator/base to check short circuit every 20 Deductors
SITC of 1KVA online UPS with external SMF 12 Volt of suitable AH battery for minimum 2 hour backup ( Luminous / Microtek / APC libert / Emerson)
31.40 (i) Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Size 1.5 sqmm (3 / 0.81mm).
Protection Engineers
Prime Computers
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .