Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.2 LAccepted-AOC SANTHOSH BHAVAN SANATHANAPURAM P O KALARCODE 688003 | KALARCODE | ALAPPUZHA | KERALA | 688003 | 1 | Accepted-AOC LOWEST AMOUNT | |
| 2 | 2₹7.4 L+₹17,719.31 (2.45%)Rejected-AOC | 2 | Rejected-AOC HIGHEST AMOUNT |
Tender Value
₹7.2 L
EMD Value
₹6,617
Closing Date
24 Dec 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE LID AND EW
OFFICE OF AEE LID AND EW AMBALAPPUZHA
Ambalappuzha BP Annual plan -Construction of storage building for Plastic bailing unit ( TENDER)
2021_LSGD_461095_3
AE/AMB/PLAN/05
Open Tender
Civil Works - Buildings
Item Rate
90 days
AMBALAPPUZHA
Please refer Tender documents.
5 documents required · 5 mandatory
₹883
Yes
₹6,617
Yes
13 Feb 2022
17 Dec 2021
28 Dec 2021
17 Dec 2021
24 Dec 2021
17 Dec 2021
60 days
Amount
Construction of Plastic Shredding Unit
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
od1512505/2021_2022 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:<br>Cement mortar 1:6 (1 cement : 6 coarse sand)
od1532734/2021_2022 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering including all lead and lifts (OD@alapuzha).
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
16.70.1 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
od1533258/2021_2022 : Providing and fixing aluminium sheets ( as approved by Engineer-in-charge) 0.38 mm .The sheet shall be fixed using self drilling/self tapping screws , complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
od1512506/2021_2022 : providing and fixing aluminium traffold sheet pre coated (size shape and pitch of corrugation as approved by Engineer in charge).45mm or nearest available thickness, total coated 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet with thickness with zinc coating 120 gm per sqm as per is 277 inpolyster top coat 15-18 microns.sheet should have protective guard filim of 25 microns minimum to avoid scraches during transportation and should be supplayed in single length up to 12 m or as directed by the Engineer in charge.The sheet shall be fixed using self drilling/self tapping screws of size(5.5mm*5.5mm)with EPDM steel complete up to any pitch in Horizontal/vertical or curver surface excluding the cost of purlin,Rafters and trusses and including cutting size and shape wherever required.
12.4.2 : Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m2
od1533248/2021_2022 : Providing and fixing 20 cm dia semi circular PVC gutter with iron brackets 40 x 3 mm size bolts, nuts and washers etc including making necessary connections with rain water pipes complete
od1517045/2021_2022 : Supplying and fixing name board as per direction of Engineer in charge, DSR
Asok Kumar V C
Bidder Name
Girish Kumar R
Asok Kumar V C
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_659913.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .