Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC PULLATH HOUSE MARATTAPPADI CHEMBRASSERI POST MALAPPURAM 676521 | CHEMBRASSERI | MALAPPURAM | KERALA | 676521 | ₹5.7 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹5.8 LRejected-AOC MANHAKKANDAN HOUSE CHATHANGOTTUPURAM PO PORUR 679328 | MALAPPURAM | KERALA | 679328 | ₹5.8 L | L2 | Rejected-AOC Highest |
Updated dates
Tender Value
₹6.1 L
EMD Value
₹15,300
Closing Date
4 Apr 2026, 4:00 pmClosed
The Executive Engineer, PMU, Manjeri
Office of the Executive Engineer, Project Management Unit, Electrical Circle Manjeri, Kerala state Electricity Board Limited, Manjeri PO, Malappuram Dist. Pin- 676 121
Constructing HT ABC line from Kattekkad to Kunnakattukuzhi and Installing 100 kVA transformer under Electrical Section Thazhecode.
2026_KSEB_840780_1
EE/PMU/MJI/E-TENDER/2025-26/13 dated.26.02.2026
Open Tender
Electrical Works
90 days
From Kattekkad to Kunnakattukuzhi
Please refer the Bid document.
7 documents required · 7 mandatory
₹1,534
₹15,300
13 Apr 2026
26 Feb 2026
8 Apr 2026
5 Mar 2026
4 Apr 2026
5 Mar 2026
Stringing of 11 kV Aerial bunched cable of size 3 x 120 + 1 x 95 sqmm with bare/insulated Messenger through existing poles
Fitting and providing one Strut using HT PSC pole including digging and back filling pit in ordinary soil.
Labour charges for loading HT PSC pole from the stacking place and unloading the same at work site (transportation by any vehicle).
Additional rate for excavation of one Pit for HT Pole/HT Stay in Hard Laterite.
Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling.
Erection of Anchor clamp / dead end clamp for 11kV ABC of any size
Fitting and erecting one HT Double Pole Structure using PSC pole in position including fitting 2 channel cross arms, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing).
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP including conveyance of materials.
Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole including digging and back filling pits in ordinary soil, drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing).
Fitting and erecting one HT PSC Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing).
Dismantling one damaged LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
Dismantling (without damage) LT stay including digging pit in all classes of soil and backfilling.
Dismantling (without damage) one km LT three phase 4 wire OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly.
Dismantling (without damage) one km LT single phase 2 wire OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly.
Transferring LT single phase 2/3 wire OH line to newly erected HT/LT pole including dismantling existing cross arm and insulators, refitting the same on the new pole, binding etc. complete.
Transferring LT three phase 4/5 wire OH line to newly erected HT/LT pole including dismantling existing cross arm and insulators, refitting the same on the new pole, binding etc. complete.
Additional rate for excavation of one Pit for HT Pole/HT Stay in Soft Rock.
Providing one Earth using GI earth pipe of size 38.1mm dia, 2.5m length including digging separate pit (0.45x0.45x2.5m) at a minimum distance of 1.5m away from the pole/structure and maintaining standard distance between different earth pipes in ordinary soil & backfilling.
Additional rate for excavation of one Earth Pit (2.5m depth) in Hard Laterite.
Erection of suspension clamp for 11KV ABC of any size
Fiting One No MVT on existing cross arm excluding termination work (for One phase) of any rating for 11 kV AB Cable
Doing one cable end termination on HT ABC of sizes Up to 3x150+1x120 sqmm and connecting to existing MVT or other terminals,using the cable end termination kit supplied departmentally including charges for cable jointer etc. complete as per the direction of the departmental officers.
Fitting and providing one HT Stay for 11kV pole, including digging and back filling pit in ordinary soil.
Fitting and erecting one HT A type Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing).
Labour charges for loading HT A type pole from the stacking place and unloading the same at work site (transportation by any vehicle).
Additional rate for excavation of Pit for A type pole in Hard Laterite.
Additional rate for excavation of Pit for A type pole in Soft Rock.
Providing concrete muffing of size 0.45x0. 45x1.5m (0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm) 0.45x0.45x1.5m, Plastering (1:3) 12mm 0.45x0.45mx5sides.
Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 numbers of poles excluding loading& unloading charges.
Transporting poles by hired vehicle to a distance beyond 5km and carrying upto 4 numbers of poles. (Running km)
Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing.
Drilling hole of various sizes on existing Channel/Cross Arm.
Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole including conveyance of materials.
Fitting one Additional 2.4/3m Channel cross arm (75x40x6mm), in existing 11kV DP including conveyance of materials.
Fitting one LT 2 line cross arm on HT or LT existing poles including fitting insulators and binding the same with LT Line.
Fitting and erecting one HT Double Pole Structure using A type pole in position including fitting 2 No. channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing).
Fitting 6 channel cross arms, AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines, etc. on existing DP structure, Fixing distribution box/provision for one set (3No.) of LT fuses, drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing & mounting of Transformer on poles.
Fitting one No. Section fuse on LT line with dropping cables, crimping sockets, connecting with bolt & nut etc.
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizondal brasing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of transportation
Cleaning and levelling of transformer yard/RMU, spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Installing one DTR Meter with box (normal size 40x25x100cm) on existing poles including fixing of 3 CTs on bus bar, laying and termination of control cable using proper lugs, fixing of meters, capacitors, control fuses and giving the complete connections including conveyance of materials.
Erecting one 100kVA Transformer to existing DP and giving connections, including loading from TMR/SRS/other stacking place & unloading at site but excluding cost for transporting transformer.
Transporting Transformers by hired vehicle to a distance upto 5km and carrying upto 2 numbers of 63/100/160/250kVA Transformers / Ring Main Units excluding loading& unloading charges.
Item Rate BoQ
BoQ_Ver3.0
E-Tender No. EE/PMU/MJI/E-TENDER/2025-26/13 dated.26.02.2026
Name of the Bidder/ Bidding Firm / Company :
CONSOLIDATED BOQ (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Quoted Amount of BOQ1 in figures
GST Rate in percentage
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1417548.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
Tendernotice_2.pdf
PDF • 0.14 MB
BOQ_1417548.xls
BOQ • 0.30 MB
E13_BID_DOCUMENT_25_26.pdf
Tender Documents • 0.82 MB
Download all tender documents and submit your bid