Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹11.3 L+₹1.3 L (13.1%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO REQUISITE CATEGORY NOT ENLISTED |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
30 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD
MAINTENANCE / REPAIRS AND COMPREHENSIVE MAINT TO LIFT AND OTHER CONNECTED MISC WORKS UNDER GE (AF) BIDAR
2024_MES_686669_1
85636/E8
Open Tender
Civil Works
Item Rate
330 days
GE AF BIDAR
As per NIT
9 documents required · 9 mandatory
₹500
GE AF BIDAR
₹20,000
Yes
21 Jan 2025
2 Dec 2024
2 Jan 2025
2 Dec 2024
30 Dec 2024
16 Dec 2024
2 Dec 2024 - 12 Dec 2024
Amount
Comprehensive maintenance of electrically operated Passenger lift No 1 at Left side of staircase of New ATC building of capacity (8 persons), 544 Kgs, Door opening 800mm of Make USHA complete all as per Notes below and as directed by the Engineer-in-Charge.
Comprehensive maintenance of electrically operated Passenger lift No 2 at Right side of staircase of New ATC building of capacity(8 persons), 544 Kgs , Door opening 800mm of Make USHA complete all as per Notes below and as directed by the Engineer-in-Charge. Notes for Sl item No 1.00 & 2.00 as below to be carried out by OEM only :- (a) Regularly & systematically examine, adjust lubricate as per standard operating procedure including testing yearly once and judgement conditions warrant the same repair / replace machine controller parts motor trust bearings, brake windings, contacts, coils, resistance for operating motor circuits and other mechanical parts. (b) To renew all wire ropes of equipment and to take reasonable care to maintain the equipment in proper and safe operating condition. (c) Examine periodically of all safety devices, governors and safety tests to be carried out as per OEM . (d) Repair replacement of misc worn out parts due to normal wear and tear.
(e) The servicing will be carried out once in 30 days by OEM technicians or his representative and service completed report shall be got signed from the User/ MES authority. (f) All responsible steps shall be taken to maintain the equipment in proper operating condition. (g) The contractor shall employ well-qualified and well-experienced supervisory personnel who have minimum qualification of ITI certification in the trade to perform the maintenance services. (h) Services shall be conducted during normal working hours at regular intervals as frequently as the company thinks necessary, having regard to the age, complaint, nature and condition and problem in operation of the elevator. (j) Technician should be systematically inspect, adjust and lubricate the parts of the elevator to the extent necessary to maintain the elevator in satisfactory working condition. k) During the break down/ failure in the elevator, a technician must respond quickly to carry out the necessary repairs in order to restore the elevator functioning immediately. (l) Parts which are not covered in routine maintenance work like ARD Batteries, car panels, door parts will be measured and paid separetely.
RECOVERY NOTE for Sl item No 1 & 2 as below : - (a) Delay in making the lift serviceable for minor complaints more than 24 hours after lodging the complaint through telephone/ SMS will attract recovery @ Rs 500/- per day (irrespective of full day or part thereof) (b) Delay in making the lift serviceable for major complaints more than the time fixed by the Accepting officer will attract recovery @ Rs 1000/- per day (irrespective of full day or part thereof) (c) Any minor spares required for making the lift serviceable shall be deemed to be included in the rate quoted.
Supply only car seal bracket assembly for lift complete all as specified and as directed.
Supply only Auto Car Door gibs for lift opening door complete all as specified and as directed.
Supply only Auto Car Door for Centre/side opening door complete all as specified and as directed.
Supply only Auto Door Landing Mechanism of Centre Opening Door along with Bottom Aluminium cill and MS powder coated frame complete all as specified and as directed.
Supply only Auto Door Landing panel of 800mm Centre/side opening door complete all as specified and as directed.
Supply only COP(cabin Operating Panels) with complete accessories complete all as specified and as directed.
Supply only LOP(Landing Operating Panels) with complete accessories complete all as specified and as directed.
Supply only of Brake Liner with complete accessories complete all as specified and as directed.
Supply only of ARD(Automatic Rescue Device) with complete accessories complete all as specified and as directed.
Supply only of LED Round light fittings 8W complete accessories complete all as specified and as directed.
Supply only Travelling cable 24 coreX0.75 sqmm of length 15 Mtr complete all as specified and as directed.
Supply only Step down transformer 500VA drive and retiring cam rectifier complete all as specified and as directed.
Supply only Brake coil 250mm dia 220v/110V/148 ohms coil for operating brake unit complete all as specified and as directed.
Supply only Rocker switch, door drive control switch complete all as specified and as directed.
Supply only Limit switches, protective device to stop lift at terminal floors during over travel complete all as specified and as directed.
Supply only Beak, protective device to lock gate / doors mechnically complete all as specified and as directed.
Supply only Contactor,80A VDC relay -2NO+2NC complete all as specified and as directed.
Supply only shoe liner, Guide shoe component complete all as specified and as directed.
Supply only Power contactor, 40 A main contactor (2NO+2NC) with 110VDC control circuit complete all as specified and as directed.
Supply only IRSU full length light curtain-door safety complete all as specified and as directed.
Supply only PCB71E position indicator signal PCB complete all as specified and as directed.
Supply only Phase reverser/VSP-2, signal phase preventer complete all as specified and as directed.
Supply only LDS ,PCB, interface between RG unit and RDS PCB complete all as specified and as directed.
Supply only Coupler RH/Coupler LH car and landing doors engagement complete all as specified and as directed.
Supply only Door/Gate track rollers with bearings / guiders complete all as specified and as directed.
Supply only LPB Box/ LPS plates for landing push box complete all as specified and as directed.
Supply only Gear box oil servo 320 complete all as specified and as directed.
Suppy and fix 12 Volts 9 AH maintenance free sealed battery complete all as specified and as directed.
M&Lfor taking the unserviceable/Burnt down main motor 3 phase 415V, 12.5 HP 1450 RPM and rewinding the same with copper wire of suitable gauge and refixing at site complete all as specified and as directed.
M&L for taking the unserviceable/Burnt cabin fan single phase 230V and rewinding the same with copper wire of suitable gauge and refixing at site complete all as specified and as directed.
supply and fixing of Invertor/ convertor card complete with control cables along with heat sink for 12 volt dc to 12/24 volt AC supply complete all as specified and as directed.
Supply and fixing of charger card complete with control cables along with heat sink for 12 volt dc to 12/24 volt AC supply complete all as specified and as directed.
Supply and fixing of 12Volt/24 volt Dc 10pin/12 pin No/Nc Contactor complete all as specified and as ditrected.
Lift Door Track / Guide mechanisum with clamps and fixing acessories complete all as specified and as directed.
Supply & fixing MCCB 4 pole, 35 kA, 200 A adjustable thermal & fixed magnetic release complete all as specified and as directed.
Supply & fixing MCCB 4 pole, 16 kA, 125 A adjustable thermal & fixed magnetic release complete all as specified and as directed.
Supply & fixing MCCB 4 pole, 16 kA, 100 A adjustable thermal & fixed magnetic release complete all as specified and as directed.
Supply, lay, connect, test and commisioning of LT XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor multistranded 50 Sqmm 3.5 core, 1100 volts grade including connecting the cable ends to the LT Panel/ Transformer /LT OH lines and distribution board complete all as specified and as directed.
Supply only 13 mm rope with complete assesories all as specified and as directed.
Dismantling the earth chamber, Excavation and removing the u/s earthing materials along with u/s earth electrodes from the existing u/s earth pits pertains to installations/ buildings and M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level, Alternate layers of charcoal & common salt Crystal, in and including back filling compund in layers and filling up with black cotton soil upto the top edge/ ground level and connected to copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly, equipment all as shown in electrical plate No. 3 of SSR Part I of 2009 & testing complete including 40mm dia light grade GI pipe upto 7.5 mtr long, excavation in any type of strata, PCC (1:3:6) type C1, earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, including 20 mm bore water pipe medium grade GI Tubing including GI Funnel, wire mesh etc complete all as specified and as directed. Note : Copper earth continuity conductor 20x3 and GI light grade protection pipe 40mm dia beyond 7.5 mtr shall be measured and paid under the respective items.
Disconnection and removing old u/s cable from the earthing equipment and S&L PVC single core copper conductor (flexible) copper cable, PVC insulated (unsheathed) 1100 volts conforming to IS:694 of 25 Sqmm complete all as specified and as directed.
Supply and installation of door motor inlcluding taking down old unserviceable one complete all as specified and directed.
Supply and installation of door transformer inlcluding taking down old unserviceable one complete all as specified and directed.
Supply and installation of Call buttons inlcluding taking down old unserviceable one complete all as specified and directed.
S&F 3 core, 2.5 sqmm PVC insulated PVC sheathed multistranded flexible copper conductor cable drawn through existing conduit / pipe from junction box to fitting complete including taking down old unsv cable complete all as specified and as directed.
Disconnection and removing the unserviceable MCB Supply and Fixing MCB TPN 16-32 Amps complete all as specified and as directed.
Disconnection and removing the unserviceable MCB Supply and Fixing MCB TPN 40-100 Amps complete all as specified and as directed.
RASI AND COMPANY (BID ID -3200359)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .