Executive Engineer, Kanchanpur Division, PWD(RnB)
Executive Engineer, Kanchanpur Division, PWD(RnB)
Urgent Mtc of road from DSD to Ananda Bazar road during the year 2024-25 /SH Providing and laying C.C interlocking Paver Block pavement at Anandabazar Market.
2025_CEPWD_68051_1
215/EE/KCP/2025-26
Open Tender
Civil Works - Roads
60 days
Ananda Bazar
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹48,494
23 Mar 2026
6 Dec 2025
12 Dec 2025
6 Dec 2025
12 Dec 2025
7 Dec 2025
7 Dec 2025 - 12 Dec 2025
I. PCC Grade M 25
II. PCC Grade M 15
80 mm thick factory made c.c. interlocking paver block of M-35 GradeProviding and laying factory made chamfered edge Cement Concrete paver blocks of required strength, thickness & size/ shape, made by table vibratory method to attain superior smooth finish using PU or equivalent moulds, laid in required grey colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per specifications & approval/ direction of the Engineer -in-Charge: (a) 80 mm thick c.c. paver block of M-35 grade with approved colour, design and pattern.
Excavation for Structures Without Dewatering Earthwork in excavation for structures as per drawing and MoRD technical specifications Clause 305.1 including setting out, construction of shoring & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. (I) Ordinary Soil (i) Upto 3 m depth
Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200 (I) Sand filling
Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement). P.C.C grade M 10 (i) Nominal mix 1:3:6
Brick masonry work in cement mortar in substructure complete excepting pointing & plastering, as per drawing & MoRD technical specification Clauses 602, 603, 604, 1202 and 1204. II. In 1:4 cement mortar
Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement) RCC Grade M25
Supplying, fitting & placing Thermo-Mechanically treated bar/cikd twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202
Providing weepholes in brick masonry / stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 Kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7.
Providing & laying filter media with jhama brick aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_69245.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.71 MB
dnitmerged.pdf
Tender Documents • 3.37 MB
BOQ_69245.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid