Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.1 CrAdmitted-Finance | +0.00% | ₹3.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.5 Cr+₹40.9 L (13.1%)Admitted-Finance 2 FRIENDS ENCLAVE SHAH NAGAR DEHRADUN | +0.00% | ₹3.5 Cr+₹40.9 L (13.1%) | L2 | Admitted-Finance |
Tender Value
₹2.8 Cr
EMD Value
₹5.7 L
Closing Date
30 Sept 2021, 5:00 pmClosed
SE CONTRACT AND PROCUREMENY II
VICTORIA CROSS VIJETA GABAR SINGH URJA BHAWAN
OVERHAULING AND REPAIRING EARTHING AND MONTHLY MAINTENANCE OF 11KV VCB PANELS AND 33KV VCB PANELS
2021_UPCLC_35524_1
CCP-II/21/2021-2022
Open Tender
Electrical Works
Item Rate
1825 days
UTTARAKHAND
Please refer Tender documents.
5 documents required · 5 mandatory
₹17,700
Yes
Executive Engineer, Electricity Store Division,
₹5.7 L
Yes
VICTORIA CROSS VIJETA GABAR SINGH URJA BHAWAN
27 Oct 2021
18 Aug 2021
1 Oct 2021
18 Aug 2021
30 Sept 2021
27 Aug 2021
24 Aug 2021
Amount
11 KV INDOOR VCB
Repairing & General Overhauling
Opening of auxiliary Bus Bars, Vacuum Interrputers, Resin phase barriers fixed and moving Contacts, Drive Insulators ets as required)
Cleaning of Carbonized auxiliary Bus bars, Vacuum Interrupters, Resin phase barriers, fixed and moving contacts, Drive Insulators etc.
General overhauling & Refitting of auxuliary Bus bars, Vaccum Interrupters, Resin phase barriers, Fixed and moving contacts Drive Insulators etc.
Opening of Operating Mechanism Associated equipment as required (Tripping Lever charging lever, interlock lever, locking drum, mechanism springs, setting screw, stop pin, trip prop set screw, spindle.lock nut trip roller, rackung arm, secondary plug flap, coil assembly, release roller ratchet, coil pot, main toggle, tripping plunger operating springs, trip coil etc)
Cleaning of Operating Mechanism/Associated equipment as required (Tripping Lever charging lever, interlock lever, locking pin, trip prop set screw, spindle.lock nut trip roller, racking arm, secondry plug flap, coil assembly, release roller ratchet, coil pot, main toggle, tripping plunger operating springs, trip coil etc)
General overhauling & Refitting of Operating Mechanism /Associated equipment as required (Tripping Lever charging lever, interlock lever, locking drum, mechanism springs, setting screw, stop pin, trip prop set screw, spindle.lock nut trip, racking arm, secondary plug flap, coil assembly, release roller ratchet, coil pot, main toggle, tripping plunger operating springs, trip coil etc)
General Overhauling/oiling of VCB truck wheels, Wheel coupling assembly, alignment of the same
General Overhauling and setting of main and CT side metallic safety shutters, shutter assembly etc.
Opening of 11 KV main panel bus bars spout bus bars CT Bus bars spouts etc as required.
Cleaning, General Overhauling & Setting of 11 KV main panel bus bars spout bus bars. CT bus bars and spout
Opening, cleaning & General overhauling of spring charging motor.
Supply of Spares for 11 KV Indoor VCB
Trip Coil.
Push botton.
11 KV Current Transformers of CG Make ratio 600/300/5A as required suitable for metering and protection purpose burden 15 VA 5P 10
11 KV Current Transformers of CG Make ratio 400/200/5A as required suitable for metering and protection purpose burden 15 VA 5P 10
11 KV Current Transformers of BHEL Make ratio 600/300/5A required suitable for metering and protection purpose burden 15 VA 5P 10
11 KV Current Transformers of BHEL Make ratio 400/200/5A required suitable for metering and protection purpose burden 15 VA 5P 10
11 KV Current Transformers of BICCO Make ratio 600/300/5A required suitable for metering and protection purpose burden 15 VA 5P 10
11 KV Current Transformers of BICCO Make ratio 400/200/5A required suitable for metering and protection purpose burden 15 VA 5P 10
11000/110 volts Three phase voltage Transformer BHEL Make.
11000/110 volts Three phase voltage Transformer CG Make.
11000/110 volts Three phase voltage Transformer ABB Make.
Flush Type switchboard mounting pattern 96x96 sq.mm AC Digital voltmeter
Indicating lamps size 22 mm coloured red amber and blue white green etc.
Male & Female Auxiliary connector
Flush mounting pattern 96x96 sq mm digital Ammeter.
over Current & Earth fault Numerical relay.
Automatic door illuminating lamp with switch.
240 V 100 W AC single phase anti/condensation heater with thermostat (0-60 deg.C) and switch.
Bus Bar Spout Epoxy Casted R Phase
Bus Bar Spout Epoxy Casted Y Phase
Bus Bar Spout Epoxy Casted B Phase
Circuit Spout Epoxy casted
Housing for vaccum interrupter
Drive Insulator
Vaccum Interrupter 11 KV 2000 Amp. 26.3 KA of Reputed Make
Master Trip Relay
TNC Swith
11 KV Earthing by Providing ACE-Chemrod (Chemical Earthing) For VCB PT CT LA Panels etc.
Installation of ACE-Chemrod (Only Labour Charges)
Digging the pit size approx 2100 mm depth & 150 mm dia or higher by drilling place ACE Chemrod Earthing Electrode. Connecting the Earthing Electrode with VCB panels with G.I Strip/Wire while making the joint, The surface Should be Cleaned thoroughly by wire brush, regmal etc if digging of pit is not practically possible than the above process may be done by horizontally but electrode will be placed a depth not less than 1.25 mtr from the surface of ground.
Installation of G.I strip Size 40x6 mm/Flexible GI/AI wire 16 Sq mm
Supply part of ACE CHEMROD
ACE CHEMROD (GI) size outer dia 48 mm lengh 2000 mm or higher with 25 kg (Minimum) Highly Conductive Substances for Soil Treatment
G.I Strip 40x6 Sq. mm
Flexible XLPE GI/AL wire 16 Sq mm
GI Crimping lug 16 Sq mm
General Maintenance of VCB (For 36 Month)
Maintenance of 11 KV VCB
11 KV Damaged CT/PT Received Back Material
Description of Work / Item(s)
Amount
33 KV VCB OUTDOOR
Repairing & General Overhauling
Opening of Pole (Bushing, Vacuum Interrputers, Auxiliary Contacts Drive Insulators, Drive Road Leavers, ets as required)
Cleaning of Carbonized Pole (Bushing, Vacuum Interrupters, Auxiliary contacts, Drive Insulators, Drive rod, Lifting rod, Leavers. Etc as required.
General overhauling & Refitting of Pole (Bushing, Vacuum Interrupters, Auxiliary contacts Drive Insulators, Drive rod, Lifting rod, Leavers etc as requried.
Opening of Operating Mechanism of circuit breaker/Associated equipment as required (Tripping Lever charging lever, interlock lever, locking drum, mechanism springs, setting screw, stop pin, trip prop set screw, spindle.lock nut trip roller coil assembly, release roller ratchet, coil pot, main toggle, tripping plunger operating springs, trip coil etc)
Cleaning of Operating Mechanism of circuit breaker/Associated equipment as required (Tripping Lever charging lever, interlock lever, locking drum, mechanism springs, setting screw, stop pin, trip prop set screw, spindle.lock nut trip roller coil assembly, release roller ratchet, coil pot, main toggle, tripping plunger operating springs, trip coil etc)
General overhauling & Refitting of Operating Mechanism of circuit breaker/Associated equipment as required (Tripping Lever charging lever, interlock lever, locking drum, mechanism springs, setting screw, stop pin, trip prop set screw, spindle.lock nut trip roller coil assembly, release roller ratchet, coil pot, main toggle, tripping plunger operating springs, trip coil etc)
Opening, Cleaning, decarbonization Refitting of incoming Terminal assembly outgoing terminal assembly connectors.
Opening, cleaning & General overhauling of spring charging motor.
Removing of Old damage/defective control wire and dressing the wiring of breaker.
33 KV C&R Panel Repairing & General Overhauling
Supply of Spares for 33 KV VCB Outdoor
Trip Coil.
Push botton.
Din rail Mounted Terminal block.
Single Phase 33 KV Current transformers of ratio as required suitable for metering and protection purpose (Outdoor type).
33000/110 volts single phase voltage Transformer (Outdoor type).
Push type swithchboard mounting pattern 96x96 sq mm AC Digital Voltmeter.
Indicating lamps size 22 mm coloured red amber and blue white green etc.
Flush mounting pattern 96x96 sq mm digital Ammeter.
Automatic door illuminating lamp with switch.
240 V 100 W AC single phase anti/condensation heater with thermostat (0-60 deg.C) and switch.
Over Current & Earth fault Numerical relay.
Kit Kat 32 Amp.
Buzzer/Hooter
T N C switch
33 KV Providing ACE-Chemrod (Chemical Earthing) For VCB PT CT LA Panels etc.
Installation of ACE-Chemrod (Only Labour Charges)
Digging the pit size approx 2100 mm depth & 150 mm dia or higher by drilling place ACE Chemrod Earthing Electrode. Connecting the Earthing Electrode with VCB panels with G.I Strip/Wire while making the joint, The surface Should be Cleaned thoroughly by wire brush, regmal etc if digging of pit is not practically possible than the above process may be done by horizontally but electrode will be placed a depth not less than 1.25 mtr from the surface of ground.
Installation of G.I strip Size 40x6 mm/Flexible GI/AI wire 16 Sq mm
Supply part of ACE CHEMROD
ACE CHEMROD (GI) size outer dia 48 mm lengh 2000 mm or higher with 25 kg (Minimum) Highly Conductive Substances for Soil Treatment
G.I Strip 40x6 Sq. mm
Flexible XLPE GI/AL wire 16 Sq mm
GI Crimping lug 16 Sq mm
General Maintenance of VCB (For 36 Month)
Maintenance of 33 KV VCB
33 KV Damaged CT/PT Received Back Material
UTTARANCHAL FORGINGS INDUSTRY
UTTARANCHAL FORGINGS INDUSTRY
M/S PERFECT TECHNICAL SERVICES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_41907.xls
BOQ • 0.38 MB
TenderspecsCCPII21202122.pdf
Tender Documents • 0.24 MB
PQRPARTI21F.xls
Tender Documents • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .