AGE(I) Dharamshala
AGE(I) Dharamshala PIN-176216
Repair/replacement of internal wiring, distribution boards, service cables and other connected works at Charri camp at Mil Stn Dharamshala.
2021_MES_453149_1
AGE(I)/DSL-04/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I) Dharamshala
As per NIT
8 documents required · 8 mandatory
₹500
AGE(I) Dharamshala
₹14,000
Yes
23 Sept 2021
21 Jun 2021
21 Jul 2021
21 Jun 2021
19 Jul 2021
5 Jul 2021
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheating FRLS electric cable 1100 volts cable in and including PVC casing and caping of suitable size (as per conductor run) with all fittings such as bend/corners/ accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm (multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly in existing CI/wooden box covered with 3 mm thick plastic laminated sheet for one light point/ fan/exhaust fan point/ bell point etc controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge. Note : i) New Sunken boxes wherever required shall be measured paid separately. ii) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 2 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
M&L for switch socket combination 2 in 1, 5 Amp and 15 Amp flush type all as specified and directed.
M&L for Switch socket combination 2 in 1, 5 A flush type all as specified and directed.
M&L for switch piano flush type single pole one way 5/6 Amp
Material and labour for Bell push Switch flush button single pole one way 5 Amps complete
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
M&L for Sub main wiring in PVC casing caping/conduit with 2 Nos single core PVC insulated copper conductor cable flame prrof size 4 sqmm multistrand and 2.5 sqmm PVC insulated flame prrof and earth wire using suitable size of copper thimble all as directed
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job.Make: Havells/Legrand/ABB
Supply and fix in replacement of MCB 10 KA 'C' curve , SP up to 5-32 Amp and 240 V all as specified and directed.
Supply and fix in replacement of MCB 10 KA 'C' curve , SPN 32 Amp and 240 V all as specified and directed.
S&F LED lights fitting 1x18W ,220V ,AC decorative box type with driver ,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilling rose all as specified and directed.
S&F LED lights fitting mirror type with high output diffuser 2 feet ,10 watt 220 V AC decorative type with driver holder with LED lamp connecting up with three core flexible copper conductor cable of suitable size all as specified and directed.
S&F LED light fitting 1x9W/1x10W bulk head lumaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed.
Material and labour for angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 15/18 watts for batten fitting, including plastic square board of required size complete all as specified.
Supply and fix AELIUS LX LED LAMP 7 W BC 6500 K 7 watt all as per Polycab Cat part No. LLP0101029 or equivalent in Bajaj/Havells/WIPRO
1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr including 4 mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 core complete all specified and as directed by the Engineer-in-Charge.
S&F LED luminaire 600 mmx 600mm ,35/36 Watt ,220 Volt AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver , holders, LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size omplete all specified and as directed.
Call bell, ding dong, AC 230 volt, single pole, complete all as specified and as directed by the Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick burried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40x40x6mm and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate complete all as specified and shown in EP-3 of SSR Part-I & as directed by Engr-in-Charge.
Supply & fix (in replacement) of existing unserviceable Sheet metal enclosure with DB’s suitable for MCBs of triple pole and neutral, 4 way, 415 volt, double door type with 200 amp rated bus bar double door type with one incoming and 12 outgoing complete all specified and as directed by the Engineer-in-Charge. Note: (i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) The disturbed surface shall be match with existing surface. (iii) Make-Cat Part No. VYV0DL-P or equivalent in Havlles /ABB
Supply and fix (in replacement) of MCB TPN/FP 40 Amp complete all specified and as directed by the Engineer-in-Charge. Make: Hager cat part No.: NBN463N or equivalent in any make as specidied in Appx'C".
KISHAN CONTRACTOR
ess are electricals and electronic
Mahashakti Enterprises
M/S HIM BUILDERS
vivek and co
M/s Raj Construction
ABHAY ELECTRICAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .