Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.5 LAccepted-AOC OFFICE NO 507 ELLORA FIESTA PLOT NO 08 SANPADA SECTOR 11 NAVI MUMBAI MAHARASHTRA 400705 | THANE | MAHARASHTRA | 400705 | 1 | Accepted-AOC L1-accepted | |
| 2 | 2₹6.8 L+₹27,740 (4.24%)Rejected-AOC ANGANWADI NO 33 SUBHASH NAGAR 37 ELENJIMOODER 30 42 MUBBELNADA AVALAULAN 34 SCOORYA NAGAR 22 KODALBONA VENDULALBEIBOUARO ANGANWADI POWDIKOUAM WARD PROJECT NO 612 25 | NEW DELHI | DELHI | 110001 | 2 | Rejected-AOC L2 |
Tender Value
₹6.6 L
EMD Value
₹16,500
Closing Date
17 Aug 2022, 5:15 pmClosed
Managing Director, KTDC Ltd
KTDC Corporate Office, Mascot Square, PMG, Trivandrum
SUPPLY, TESTING AND COMMISSIONING OF 50 kVA OR NEAREST HIGHER CAPACITY DG SET
2022_KTDC_500198_1
AE(E)II/KTDC.EW-TVM/TEH-GVR-DG
Open Tender
Equipments
Item Rate
30 days
Guruvayoor
As mentioned in NIT and special conditions
8 documents required · 8 mandatory
₹1,652
₹16,500
20 Jun 2023
4 Aug 2022
23 Aug 2022
4 Aug 2022
17 Aug 2022
4 Aug 2022
Amount
Supply, Testing and Commissioning of 3 phase 50kVA Diesel-Generator set with acoustic enclosure as per CPCB II norms suitable for placing in the outdoor with the following specifications. (Approved Make- Cummins, Kirloskar,Caterpillar)
Engine
Suitable HP rated Water / liquid cooled, Radiator type, turbo charge aspirated 4 Stroke Electric Start engine with automatic speed regulation /digital engine governing system to develop mechanical output so as to satisfactorily generate full load electrical output in par with the alternator specifications as per given below with out sag in the line parameters at electrical side as recommended by the OEM
Alternator
40 kW Brushless, Self excited, Self regulated alternator suitable for continous operation at 1500rpm with Automatic voltage regulation system to Generate 3 Phase, 4 Wire 415V +/- 1 % AC 50Hz at 0.8 lag pf Supply, insulation class F/H, 2/3 pitch, double layer lap wound stator winding, dynamically balanced rotor, low THD conforming to BS 5514 & ISO 3046 of make as recommended by the OEM
Accoustic Enclosure
Canopy type Accoustic enclosure including air intake / exhaust baffles, sliding doors with suitable hinges, locks etc. for the DG sets using accoustically treated panels housed in 1.6 & 3mm / 0.5mm CRCA / LCMS / HRCA sheet steel section filled with special grade 100 mm Thick 96 kg/m3 Density Rock Wool, covered with R. P. Tissue Paper and Expended metal on wall specially designed for optimum sound attenuation with frameworks complete. with inspection lamps, inspection glass window, provision for Cable Entry, control cables, etc. complying to IS 8183
Generator Control Panel
Dust tight, vermin proof GCP falling to IP43 category fabricated out of 16 / 18 SWG CRCA Sheet Steel painted as per standards of the following specifications ( All switches shall confirm to conforming to IEC 60947-2 standards).
The Panel shall be provided with Digital Engine Controller unit suitable for integration to AMF Relay system, suitable rating MCCB/MCB with O/C & S/C Protection as recommended by OEM, TPN best conductivity busbar with SMC supports, heat shrinkable sleeves etc. capable to handle generator full load current.
Suitable rating Class 1.0 Metering CTs per phase as recommended by OEM, multifunction / induvidual meters to read current in each phase, line to line and phase voltages, frequency, energy generated ( Wh) per phase and cummilative, hours of operation, powerfactor status, RYB Phase indicators ( LED Pilot type ) with suitable rating control MCB including all necessary control wiring etc. complete as per standards. ( Note : - The GCP shall meet all the statutory requirements complied with the Kerala State Electrical Inspectorate )
Stantard accessories
Both Engine & Alternator shall be suitably coupled and mounted on common channel iron base frame with standard accessories such as anti vibration pad, required capacity battery, suitable battery-charger unit with charging arrangements from direct mains, As per OEM standards Capacity Diesel tank, residential type silencer, suitable cable termination box etc. complete as per Electrical Inspectorate standards, rules & regulations
The DG Control Panel shall be compatible for PLC based Auto mains failure system employed in the Main Panel.
50 kVA DG SET
Harmony engineers pvt ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .