Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Acceptance of Contract | |
| 2 | L2₹30.5 L+₹1.6 L (5.57%)Rejected-AOC 117 BHAISAHIYA TOLA GANESHGANJ MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | MIRZAPUR | UTTAR PRADESH | 231001 | L2 | Rejected-AOC OK | |
| 3 | L3₹30.9 L+₹2.0 L (6.86%)Rejected-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L3 | Rejected-AOC Ok | |
| 4 | L4₹31.3 L+₹2.4 L (8.27%)Rejected-AOC | L4 | Rejected-AOC OK | |
| 5 | L5₹32.6 L+₹3.8 L (13.0%)Rejected-AOC INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L5 | Rejected-AOC OK |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
14 May 2025, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
REPAIR AND MAINT OF INTERNAL ELECTRIFICATION, FITTING AND FIXTURES INCLUDING DBS AND SUBMAIN WIRING AT SOUTH COMPLEX UNDER GE IMA DEHRADUN
2025_MES_704484_1
GE/IMA/T-10 of 2025-26 9516/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE IMA Dehradun
As per tender documents/NIT
6 documents required · 6 mandatory
₹500
Yes
GE IMA Dehradun
₹90,000
Yes
10 Jun 2025
16 Apr 2025
21 May 2025
16 Apr 2025
14 May 2025
30 Apr 2025
Amount
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as specified and directed.
M&L for modular point re-wiring with single core PVC insulated unsheathed 1100 volt grade FRLSH cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 25 mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawl plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of modular flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLSH cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch . Notes: 1 The contract site mainly comprises of OTMs where point wiring may exceed its standard length. 2. The standard safety equipments and tools & plants including ladders etc to electricians / helpers will be provided by the Contractor without any additional cost to the department . 3. The contractor will make good of disturbed surfaces with material (incl plaster,putty) required to matchup with existing surfaces without any additional cost to the dept. This condition applies to all the materials in the BOQ.
All as per Srl item No 2 above for point wiring for one light point controlled by two Nos two way switch complete all as specified and directed.
All as per Srl item No 2 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed.
All as per Srl item No 2 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed.
All as per item No 2 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete.
All as per Srl item No 2 above but point wiring for one bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed.
S&F in repair of Modular switch single pole one way 6/10 amp white in colour complete all as specified and directed by Engr-In-Charge.
S&F in repair of Modular switch single pole one way 16/20 amp white in colour complete all as specified and directed by Engr-In-Charge.
S&F in repair of Modular switch 6/10 amp, single pole, two way white in colour complete all as specified and directed by Engr-In-Charge.
S&F in repair of Modular bell push 6/10 amp 240 volts white in colour complete all as specified and directed by Engr-In-Charge.
S&F in repair of door bell ding dong type, AC, 240 volts, single pole complete all as specified and directed by Engr-In-Charge.
S&F in repair of Modular socket outlet 2/3 pin combined 2 module 16 amp white in colour complete all as specified and directed by Engr-In-Charge.
S&F in repair of Modular socket outlet 2/3 pin combined 2 module 6 amp white in colour complete all as specified and directed by Engr-In-Charge.
S&F in repair of ceiling rose 3 phase pvc/polycarbonate, isolated body white in colour complete all as specified and directed by Engr-In-Charge.
S&F in repair of batten holder, insulated polycabonate body with back plate white in colour with LED inverter bulb 9 watt complete all as specified and directed by Engr-In-Charge.
S&F in repair of modular fan step regulator 100 W 2 module white in colour complete all as specified and directed by Engr-In-Charge.
S&F in repair of LED tubelight batten fitting 20 Watt not less than 100 lumen/watt made of aluminium housing suitable for fixing on walls/ceiling, warm/natural/cool white as per requirement at site complete all as specified and directed by Engr-In-Charge.
S&F in repair of LED flood light fitting 50 Watt not less than 100 lumen/watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs with secondary lens with IP66 protection suitable for fixing on walls, warm/natural/cool white as per requirement at site complete all as specified and directed by Engr-In-Charge.
S&F in repair of LED tubelight batten fitting 10 Watt not less than 100 lumen/watt made of aluminium housing suitable for fixing on walls/ceiling including connections, warm/natural/cool white as per requirement at site complete all as specified and directed by Engr-In-Charge.
S&F in repair of LED bulk head fitting 10 Watt not less than 100 lumen/watt made of aluminium housing suitable for fixing on walls/ceiling including connection complete all as specified and directed by Engr-In-Charge.
S&F in repair of LED 36 Watts,2'x2' recessed ceiling light fitting not less than 100 lumen/watt fabricated CRCA steel sheet housing with high efficient LEDs,IP 20,warm /natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.
S&F in repair of LED 36 Watts, 2'x2' surface mounted ceiling light fitting not less than 100 lumen/watt fabricated CRCA steel sheet housing with high efficient LEDs, IP 20,warm /natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.
S&F in repair of LED 15 Watt surface mounted not less than 100 lumen/watt round/square ceiling light fitting,warm /natural/ cool white as per requirement at site made of aluminium housing high translucent frosted plastic diffuser with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.
S&F in repair of LED 15 Watt recess mounted not less than 100 lumen/watt round ceiling light fitting,warm /natural/ cool white as per requirement at site made of aluminium housing high translucent frosted plastic diffuser with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.
S&F in repair of plug and socket metal enclosure box of module (2P+E- SP), IK 08, supplied with Neutral Links complete with one MCB SP 20 amp,240 Volts recess mounted with chained metal cover for the socket outlet complete all as specified and directed by Engr-In-Charge.
S & F in repair of sub main wiring with PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in and including rigid PVC conduit of size not less than 25 mm dia in concealed / surface as required at site including one run PVC insulated unsheathed cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down old unsv submain wiring of following sizes complete all as specified and directed. Note: (i) Two/Four run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc. (iii) Phase sequence colour code must be follow i.e Phase( Red) and Neutral ( Black) In colour and for three Phase RYB For phase and black for neutral.
2 x 10 Sqmm + 1 x 10 Sqmm
2 x 6 Sqmm + 1 x 6 Sqmm
2 x 4 Sqmm + 1 x 4 Sqmm
4 x 10 Sqmm+ 2 x 10 Sqmm
4 x 16 Sqmm+ 2 x 10 Sqmm
S & F in repair of VTPN Distribution boards epoxy powder coated fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with fully insulated copper busbar of suitable capacity for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for IP-43 IK -09, 415 volt with provision for 160/200 Amp MCCB FP as incomer and SP MCBs or TP MCBs as per site requirement (or any combination of SP/TP MCBs) outgoings of following capacity.
4 Way VTPN DB
8 WAY VTPN DB
12 WAY VTPN DB
S & F in repair of MCB DB complying with IEC 61439 -1 & 3., sheet metal enclosures double door with provision for 01 x 40 to 63 A SPN MCB as incoming and MCB SP 6 to 32A as out going as per way of DB.The DBs should be supplied with tin platted insulated copper bus bar rated for 200A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed of following capacity.
4 way SPN DB.
8 way SPN DB.
12way SPN DB.
S & F in repair of MCCB 3 pole (for 125 Amp) & 4 pole (for 160 & 200) ICS=100% ICU at 415 volts with rupturing capacity 16 KA with thermal-magnetic release and adjustable overload setting complete all as specified and directed of following capacity.
S & F in repair of MCB SP complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable complete all as directed of follwing capacity:
MCB SP 6 to 32 Amp.240 volts
MCB SPN 40 to 63 Amps 240 volts
S & F in repair of MCB TPN/FP 63/100 amp as per requirement complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable complete all as directed.
S & F in repair of TPN DB 4 way complying with IEC 61439 -1 & 3., sheet metal enclosures double door with provision for 01 x 63/100 A `TPN MCB as incoming and MCB SP 6 to 32A as out going as per way of DB.The DBs should be supplied with tin platted insulated copper bus bar rated for 200A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20 mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge.
S&F in repair of UNSV rigid non metallic PVC conduit medium grade ISI marked ivory colour along with accessories in recess including cutting the wall and making good disturbed surfaces of following sizes:-
25 mm dia
S& F modular fitting /fixture in repair of following specification:-
Fan regulator modular step type 100W 240 volts 2 module.
Modular switch single pole one way 6 Amp 240 volts.
Modular switch single pole one way 16 Amp 240 volts .
Modular socket outlet 2/3 pin combined 6 Amp 240 volts.
Modular socket outlet 2/3 pin combined 16 Amp 240 volts.
Modular bell push flush type, 6 Amps 240Volts.
S& F fitting /fixture in repair of following specification:-
Fan regulator step type 100W 240 volts 2 module.
piano type switch single pole one way 6 Amp 240 volts.
piano type switch single pole one way 16 Amp 240 volts .
socket outlet 2/3 pin combined 6 Amp 240 volts.
socket outlet 2/3 pin combined 16 Amp 240 volts.
S&F switch socket combination box 16 Amp, 6 pin, 3 module (2 hole complete with suitable connection with 2x2.5 sqmm and 1x1.5 sqmm single core cable length upto 01 mtr complete all as specified and directed by Engr-In-Charge.
S&F in repair of white modular cover plate with frame of following module complete all as directed.
1Module
2Module
3Module
4Module
6Module
8 Module
12 module
S&F in repair of modular metal flush box of following module complete all as directed.
1Module
2Module
3Module
4Module
6Module
8 Module
12 module
S&F plug top 3 pin 16 Amp 240 V plastic body white in colour complete all as specified and directed by Engr-in-Charge.Make: Anchor/legrand/havells
S&F in repair of LED 36/40 Watts,4'x1' recess ceiling light fitting not less than 100 lumen/watt made of CRCA steel sheet housing suitable for POP/grid ceiling,warm /natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Note: It is to be noted that any gap created by dismantling old light and fixing the LED light will be filled with POP and match with the existing surface.
S&F in repair of LED 36/40 Watts,4'x1' surface mounted ceiling light fitting not less than 100 lumen/watt made of CRCA steel sheet housing suitable for POP ceiling,warm /natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.
S&F in repair of LED 24 Watts,1'x1' recessed ceiling light fitting not less than 100 lumen/watt made of die cast aluminium housing suitable for POP ceiling,warm /natural/ cool white as per requirement at site with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.
S&F in repair of P-17 Tempra plug & socket DB's of module (3P+N+E- FP) , IK 08, supplied with Neutral Links complete with MCB FP 100 amp, 415 volts recess mounted with industrial plug top complete all as specified and directed by Engr-In-Charge.
S&F in repair of twin glow LED 20 W + 20 W up-down batten tubelight fitting (Yellow Uplight Relax Mode and White Downlight Work Mode) Aesthetic Design, Ambience of Downlight & Covelight from Tubelight made of polycarbonate with glare free uniform illumination with electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.
S&F in repair of LED flood light fitting 150 Watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs with secondary lens with IP66 protection suitable for fixing on walls, warm/natural/cool white as per requirement at site complete all as specified and directed by Engr-In-Charge.
M&L GI wire of 4 mm dia suitable for connecting from earthing point to DBs complete all as specified and directed by Engr-In-Charge.
NOTE :- In Repairs means - rate include for taking off Old items and connecting pieces, bolts, nuts, screws etc and removing as directed and making good the same to match with the existing surface or preparing for new as required.
prabhawati shanti automobiles (BID ID -3296869)
PARADISE INFRA POWER COMPANY (BID ID -3292076)
Mani Control System (BID ID -3295832)
KRISHANA ELECTRIC WORKS (BID ID -3291643)
M/s badrinath Traders (BID ID -3296829)
RAMSONS DEVELOPERS (BID ID -3291923)
M/S K K ENTERPRISES (BID ID -3296987)
M/S Durvish Mourya (BID ID -3296094)
V r traders (BID ID -3296172)
Deven Associates (BID ID -3297134)
anant enterprises (BID ID -3292285)
Balraj and Co (BID ID -3295784)
JS CONSTRUCTION COMPANY (BID ID -3296543)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .