Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.9 L+₹10,466 (1.54%)Rejected-AOC 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.1 L+₹32,032 (4.72%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹7.9 L+₹1.1 L (16.3%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹8.3 L+₹1.5 L (22.1%)Rejected-AOC 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 | AJMER | RAJASTHAN | 305001 | L5 | Rejected-AOC L5 |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
6 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) NO 2 JODHPUR
GE (AF) NO 2 JODHPUR
REPAIR/ MAINT OF E/M INSTALLATION AND E/M EQUIPMENTS AT AF STN MT ABU AND GURUSHIKHAR UNDER AGE E/M, GE (AF) NO 2 JODHPUR
2020_MES_385362_1
8201/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) NO 2 JODHPUR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (AF) NO 2 JODHPUR
₹19,800
Yes
11 Dec 2020
12 Oct 2020
9 Nov 2020
12 Oct 2020
6 Nov 2020
24 Oct 2020
60 days
Amount
Disconnecting and removing from site step down 11KV/440 Volts transformer complete.
Disconnecting the transformer by taking out transformer oil for comprehensive maintenance of all parts including winding and terminals , replacement of rubber gasket sheet ,silica gel, cleaning and removing moisture from it taking all the assembly of transformer and removing / repairing the unserviceable parts, reassembling it after repair testing and commissioning the transformer of capacity 400 KVA stepdown type complete all specified and directed. Note. Rewinding of transformer complete with super enamelled copper winding wire including insulating material and labour for winding of transformer of capacity 400 KVA included in item rate.
Checking of ACB 1100 Volt cap 630-800 Amps and servicing/maintenance through authorised dealer for rectification of fault, connecting and testing on load all as directed by Engr-in-charge. Note: Replacement of unserviceable spares shall be included as follows:-
Supply and fixing of manual charging handle assy as per existing make and model complete
Supply and fixing of trip coil as per existing make and model complete
Supply and fixing of close coil as per existing make and model complete
Taking down old U/S solar charges existing battery 12 Volts from existing complete
Taking down old U/S CFL 11 Watt of soalr light from the existing complete
S&F in repair CFL charging circuit with CFL operating circuit for soler street light
S&F in repair solar light fitting Cat part No. BJSLF 211 DD S Type CFL 2 X 11 Watt of Make Bajaj / Equilent Modle of Philips/ crompton / Havells.
S&F in repair existing pole soler charges and existing battery 12 volts 6 cells, rating 140 AH for solar light fitting.
M/L for servicing and maintenance of insect killer make pest--O- flash including replacement of fly catcher rod 18 watt with holders-02Nos, outer cover holding nuts,fastnuts bolts etc.
M/L for servicing and maintenance of flood light including taking down lights-08 Nos pianting of poles ,lights holding clips metallic ,replacement of 08 Nos MH lights of 150 Watts with 70 Watt LED including following work services
Disconnecting and taking down lights-08 Nos
Painting of poles
Lights holding clips metallic and other connected items required
70Watt LED flood light-08 Nos
M/L for repair/maintenance of LT control Panel comprising the following
Taking down panel for repair from existing site
Supply and fixing of MS sheet 16 SWG( 1.6 mm ) and fabrication of back side cover of LT panel including cutting to required size and shape fixing in position by bending, welding all as required for proper functioning of LT panel shutters including two coats of coats of synthetic enamel paint over a coat of red oxide.
Supply and fixing of hinges , tee type stove enameled black medium weight , cold rolled and mild steel 30 mm size and fixed door shutters
Supply and fixing of locking arrangement with MS sliding door bolts hasp and suitable for use with pad lock of size 200 mm.
Mild steel work conforming to Fe-410-0 or Fe-310-0 as in angle iron frame work , cut to size including bending and welding angles as necessary and re -fixing of MS sheet of panel incuding a shop coat of red oxide primer.
paint on panel after performing form work and fix at existing site
M/L for repair/maintenance of fire alarm system comprising the following work services
Taking down u/s fire alarm panel-01and smoke detectors-08of any make/size
Supply and fixing Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360
Fire alarm panel 4 Zone operating temp 0-40 degree,power I/P230Volt AC/12 Volt DC
Flame Proof Point wiring with 1.5 Sqmm single core PVC,unsheathed multi stranded copper conductor FRL S cable 1100 volt grade
Taking out old u/s burnt LT U/G cable of sizen 240 sqmm 3.5 core
Supply ,laying,testing and commissioning PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area (a)240 sq. mm 3.5 Core
Taking out old/burnt MCCB's from site of any make/size
S&F MCCB 3 Pole , 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
S&F MCCB 3 Pole , 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
S&F MCCB 3 Pole , 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
S&F MCCB 3 Pole , 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA
S&F MCCB 3 Pole , 415 V, Adjustable type,630 Amps with breaking capacity 36 KA
S&F,testing,commisioning submersible pump panel totally enclosed floor mounted type cabinet 1.2m x 1.0m x 0.4m fabricated made out of 16 SWG MS sheet and angle iron frame 40x40x6mm frame work cubical . The panel should be vermine proof with IP-55,, protection suitable 415/440V, AC 50 Hz, 3 Ph, 4 wire system panel board should be painted with two coat of approved shade grey enamel paint over one coat of red oxide. The panel shall be front opening type consisting of copper bus bar of 200 Amps capacity for phase and neutral and consisting of the following :-
MCCB 4 pole 100 Amps, 36 KA, 415V, 3 Ph-01 Nos
Indicator neon lamps (R-Y-B) with holder complete panel mounting type-0ne set (Set of three).
Cable gland – 01 No,earthingTerminal – 01 Set.
63 Amps, 09 KA – 02 Nos,
FASD starter suitable for submersible pump set 7.5 HP (For relay range 6-10 Amp) - 02 Nos,
M/S Balkishan Panwar Construction
Choudhary Traders and Engineers
SHOBHIT BUILDERS
M/S JAGDAMBA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .