Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹39.4 LAccepted-AOC KURUPPAMPARAMBIL PERUMPADAPPU PALLURURHY P O ERNAKULAM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L 1 | Accepted-AOC due lowest tender | |
| 2 | L 2₹42.2 L+₹2.7 L (6.81%)Rejected-Finance CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | L 2 | Rejected-Finance Rejected being not lowest | |
| 3 | L 3₹42.4 L+₹2.8 L (7.18%)Rejected-Finance GP KIZHAKKAMBALAM KOLENCHERY | THRISSUR | KERALA | 680667 | L 3 | Rejected-Finance Rejected being not lowest | |
| 4 | L 4₹42.6 L+₹3.1 L (7.88%)Rejected-Finance 27 2387 A CHITTUTHARA SASTRI NAGAR SMARTO ROAD KADAVANTHARA KOCHI 682 020 | ERNAKULAM | KERALA | 682020 | L 4 | Rejected-Finance Rejected being not lowest | |
| 5 | L 5₹43.0 L+₹3.5 L (8.88%)Rejected-Finance KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | L 5 | Rejected-Finance Rejected being not lowest |
Tender Value
₹45.4 L
EMD Value
₹90,800
Closing Date
15 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER NW KOCHI
GARRISON ENGINEER NAVAL WORKS MILITARY ENGINEER SERVICES KATARIBAGH NAVAL BASE POST KOCHI 682004
ADDITION/ALTERATION TO SIT OUT BALCONY AT BLDG NO P-68 AT KARTARIBAGH NAVAL BASE KOCHI AND OTHER SANCTIONED WORK OF AGE B/R III AND AGE E/M UNDER GE NW NAVAL BASE KOCHI
2020_MES_356175_1
GE(NW)/KOCHI/8869/E8
Open Tender
Civil Works
Item Rate
180 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NW KOCHI
₹90,800
Yes
1 Sept 2020
26 Jun 2020
17 Jul 2020
26 Jun 2020
15 Jul 2020
10 Jul 2020
60 days
Amount
Demolition of brickwork or stone/boulder masonry or PCC block masonry built in cement mortar including all quoins,pillars etc excluding ashlar facing,dressed stone work and pre cast concrete articles and pre cast concrete block walling complete all as specified .
Dismantling of plain or corrugated steel sheeting/AC sheets any gauge, thickness including nanital or similar pattern roof covering complete
Demolition of reinforced cement Concrete Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work complete
Excavating in trenches, not exceeding 1.5 m wide andnot exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc.not exc 10 sq m on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineert-in-Charge.
M&L for plain cement concrete in 1:4:8 type D2 using 40 mm graded stone aggregate for foundations, filling and mass concrete, concrete layer below plinth beam etc all as specified
M&L for RCC 1:2:4 type B 1 (using 20 mm graded stone aggregate ) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified all as specified
M&L for RCC 1:2:4 type B 1 (using 20 mm graded stone aggregate ) as in beams; cantilevers,bressummers,lintel over 1.5 mtr span, complete all as specified
M&L for RCC 1:2:4 type B 1 (using 20 mm graded stone aggregate ) as in coloumns complete all as specified
M&L for RCC 1:2:4 type B 1 (using 20 mm graded stone aggregate ) as in roof slabs complete all as specified
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with andincluding mild steel wire (annealed) not less than 0.9mm dia or securing with clip all as specified and directed .
All as per item No 10 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified and directed .
M&L for Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation, pile caps and plinth beams; and similar work; vertical or to batter for rough finished flat all as specified
M & L formwork to sides of pillars, posts, struts, columns square, rectangular or polygonal on plan, for rough finished surface of concrete
M & L formwork to sides and soffits of floor or roof beams, bressummers, lintels, shelves including supports for fair finished surface of concrete all as specified
M&L formwork to Soffits of Suspended Slabs such as Roof Slabs, Floor Slabs, Landings and Similar Work, not exc. 200mm thick (Horizontal or Sloping) flat, rough finished surfaces of concrete, complete all as specified and as directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed
M&L for pre-cast cement concrete block masonry in Type C1, 1:3:6 (20mm graded aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed
M&L for rendering 15mm thick on other than fair face of brick work or concrete surfaces in 1:6 cement mortar finished even & smooth (without using extra cement.) all as specified and directed .
M&L for rendering 15mm thick on fair face of brick work or concrete surfaces in 1:4 cement mortar finished even & smooth (without using extra cement.)using water proofing compound all as specified and directed (water proofing compound shall be measured and paid separetely).
Supply only Water Proofing compound, conforming to IS and as approved, complete all as specified.
M & L for preparation surfaces of new and old plastered surface of wall and applying 3 mm thick wall care putty and of two coats of acrylic interior emulsion over a coat of suitable primer complete all as specified
M & L for preparation surfaces of new and old plastered surface of wall and applying of two coats of Appex ultima protek top coat over a coat of protek base primer complete all as specified
M&L pre construction anti termiteTreatment at the Top Surface of filled earth at the rate of 5.00 Litres of Emulsion per Square Metre of Surface, complete all as specified and as directed
M & L for hardcore of broken stone of boulders gauge exc. 63 mm but n exc 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified .
M&L for 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base of floor complete all as specified .
M&L for 50 mm thick Cement concrete (1:2:4) type B-1, using (20mm graded aggregate) as in floor finish, plinth protection,path ,pavement etc, surfaces finished rough all as specified and as directed .
M&L for Screed bed or bedding layer in CM (1:6), 15 mm thick for laying in floor finishes all as specified and directed .
M&L for rendering in CM (1:4), 10mm thick on vertical surface for receiving wall tiles complete all as specified and directed .
M&L for vitrified ceramic coloured tiles, double charged/ultra charged 10 mm thick (square / rectangular), polished, area of each tile exc 0.36 sqm but not exc 0.42 Sqm, laid in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match and fixing of tiles with chemical on the existing floor complete all as specified and directed
M&L for vitrified ceramic coloured tiles, 10 mm thick (square / rectangular) in skirting/dado laid over screed. set & jointed in neat cement slurry & pointed in white or coloured cement to match on the complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutters from frames) exc 1.50 sq. m but not exc 4 Sqm each all as specified
S&F 5 mm thick sheet glass ordinary quality glazing with oil putty and glazing pins/spring clips in square not exceeding 0.50 sqm in each pane fixed to aluminium or wooden frame work using necessary beadings etc complete all as specified and directed
M&L for 75 mm thick cement concrete (1:3:6) type C-2, using (40mm graded aggregate) as in plinth protection,path ,pavement etc, surfaces finished sooth with out using extra cement complete all as specified and as directed .
M&L for netlon wire mesh 2-3 mm fixed with stainless steel wire staples to wooden shutters or steel frames including wooden beads complete all as specified and as directed .
S&F 2 nd class hard wood 25 mm dia decorative wooden curtain rods,with approved sample including end konbs brackets for fixing the curtain rod,polishing complete all as specified and directed
M&L for first class hard wood plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints,complete all as specified and directed
M&L for 40 mm thick first class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified
S & F first class hardwood 30 mm thick glazed skeleton shutters, open rebated and prepared to receive glass, guaze etc, (without sash bars), edges of framing plain, chamfered or rounded fitted with cut, and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part I, section 8, clause 8.24(b) complete all as specified
M&L for preparation on wooden surface exceeding 10 cm width or girth and applying two coats of P U (polyurethane) wood polish complete all as specified .
S&F 125 mm butt hinges cast brass,with mild steel hinge pin,bright polished and fixed , type B-11 complete all as specified and directed .
S&F 75 mm butt hinges cast brass,with mild steel hinge pin,bright polished and fixed , type B-11 complete all as specified and directed .
S&F 150 mm long brass handles cast type, polished bright complete all as specified and directed .
S&F 100 mm long brass handles cast type, polished bright complete all as specified and directed .
S&F 150 mm long brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixedcomplete all as specified and directed .
S&F 100 mm long brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed .
S&F Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixedcomplete all as specified and directed .
S&F mild steel flat iron of size 25x 3 mm as in hold fast for fixingdoor/window frames or other similar items conforming to Fe-410-0 or Fe-310-0 complete all as specified
M&L for plain cement concrete in 1:2:4 type B 1 using 20 mm graded stone aggregate for embedding hold fast etc including necessary form work complete all as specified
M&L for ward robe / CB of size 2.75 x2.85x0.60 mtr made out of 18 mm thick multi wood back and side covering fitted with 40 mm thick first class hard wood sliding shutter including brass handles,locking arrangement,necessary partitions/drawer complete all as specified and all as shown in sketch
M&L for rendering 20 mm thick on brick work or concrete surfaces in cement mortar 1:3 finished even & smooth (without using extra cement.) using water proofing compound all as specified and directed (water proofing compound shall be measured and paid separetely).
M&L for seven course water proofing treatment on RCC Roof with the following Specifications and Manu-facturer's instructions, complete all as specified and as directed :-(i) Preparing and cleaning of fully dry plastered surface as per IS:3067-1966.(ii) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.2 Litre per Sqm.(iii) Applying evenly One Coat of Blow Hot Bitumen of grade 85/25 @ 1.20 Kg per Sqm on Primed Surfaces.(iv) Applying a layer of APP based Polymeric Membrane; 4.00 mm thick (minimum) weighing 4.00 Kg Per Sqm (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction.(v) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.2 Litre per Sqm.(vi) Applying evenly One Coat of Blow Hot Bitumen of grade 85/25 @ 1.20 Kg per Sqm on Primed Surfaces.(vii) Applying a layer of APP based Polymeric Membrane; 4.00 mm thick (minimum) weighing 4.00 Kg Per Sqm (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction. (viii) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane.
S&F interlocking aluminium alloy anodized snap grid consists of main Tee runners of size 38mm x 25mm x 1.5mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x 1.5mm, 1200mm long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Tee 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25x25x2mm, aluminium alloy extruded section shall be aluminium anodized (minimum 15 micron) and shall conform to IS-733, IS-1285 and IS-737 including GI hangers 6 mm dia (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flats 40x3mm size 60 mm long and expansion hold fastners 12.5mm dia 40mm long complete all as specified
S&F 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework in ceiling as per manufacturer's instruction all as specified
M&L for 20 mm thick screed bed or bedding layer in cement mortar 1:6 on floors for laying floor finishes all as specified and directed
M&L for hard wearing ceramic tiles, 10 mm thick (square / rectangular), area of each tile not exc 0.36 sqm, laid in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match all as specified (Make : VC shield series of SOMANY / Abrasion resistant series of Johnson)
S&F 10 mm thick shower toughen glass partitions including stainless steel rod on top with clip fixed on wall for holding of glass,including suitable hinges for shutter,25 mm dia 200 mm long 2 Nos stainless steel handle in each shutter complete all as specified
M&L for 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L type or J type or cranked hook bolts fixed in roofs and walls complete all as specified
M&L for clean off all surface coating and stain around the leakage area. Study and determine leak pattern and establish leakage source. Drill injection ports at distance of 200mm c/c to intercept the leak paths. The injection ports shall be drilled at a depth required. Check for positive interception of injection ports on to leak path by observing for leakage diversion through injection ports. If leak is not detected in the injection ports, change location or angle and redrill. Onece positive interseption is confirmed, clean injection ports with water and install mchanical injection packers. Injection packers shall have check valve, which prevents back flush of grout and capable of holding pressure of up to 1050 PSI ( 7 N/sqmm). Pump water through injection packers to flush out leak path as well as saturate it with water (If necessary). Ceal off honey comb area or larger crake, which leak severly when pumed with water, with hydrwalik cement (if necessary). Pump the water reactive polyurethane grout thrugh injection packers to a prescribed pressure. As the grouts expand during the reaction with water, it is necessary to reterned to previously grouted points to check that the presceibed back pressure is mainted before grout is fully cured. Remove injection packer after the grout has fully cured. The quoted rate is inclusive of all labour invovle in drilling, fixing packer, injecting, removing, cealing,etc. chemical used Sika's Sika injection 101h & Sika injection 201 CE complete all as specified
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/ loose soil complete all as specified and as directed by Engineert-in-Charge.
M & L for coarse aggregate for granolithic floors, graded from 12.5mm to 4.74mm, spread and levelled in layers n exc. 15 cm thick, well rammed to a true surface complete all as specified
M&L for Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment all as specified
M&L for plain cement concrete in 1:2:4 type B 0 using 12.5 mm graded stone aggregate as in mass concrete arround the paver block chamfered on edges etc including necessary form work complete all as specified
Removing excavated soil exc. 500 Mtr and not exc 1.50 KM depositing where directed at a level not exc. 1.5 m above the starting point all as specified and as directed .
S&F rolled mild steel work(beam,tee,angle,channel or flat sections) and square bars for framed work as in drain cover or other sections rails braces etc conforming to Fe-410-W,(Grade E-250) quality 'A' including necessary fixing arrangements like hold fast etc complete all as specified and as directed by .
M&L for preparation on new steel surface exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of metal primer complete all as specified .
M&L for PVC coated gabion boxes,3.70 mm diameter wire with mesh size 60 mmx 80mm in sea wall complete all as specified .(filling meterial shall be measured and paid seperately)
M&L for broken stone or boulders hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified .
M&L for plain cement concrete in 1:2:4 type B 1 using 20 mm graded stone aggregate as in coping including necessary form work complete all as specified
M&L for rendering 15mm thick on fair face of brick work or concrete surfaces in 1:6 cement mortar finished even & smooth (without using extra cement.) compound all as specified and directed .
M & L for preparation of new or perviously untreated surface of walls and applying two coats of cement based paint over a coat of clearcolle on plastered surface ,complete all as specified and as directed by Engr-in-Charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80mm thickness, M-40 grade with grey cement and pigment all as specified
Material and labour for point wiring for one light/fan point with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC conduit medium grade ISI marked concealed of suitable size with all accessories and sunken box of 1.6mm thick pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and as directed
All as per item No.72 here in before but for one bell point controlled by one 5 Amp bell push on independent board complete all as specified and directed.
All as per item No.72 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed.
All as per item No.72 here in before but for one 5 pin 5 Amp socket outlet point on same board complete all as specified and directed.
All as per item No.72 here in before but using with 2.5 sqmm copper conductor cables multistranded (FRLSH) PVC insulated, unsheathed cable and including 2.5 sqmm copper conductor cable multistranded (FRLSH) PVC insulated and unsheathed cable as earth continuity wire and connecting to common earth dolly for one 6 pin 15 Amps socket outlet point on independent board complete all as specified and directed.
Material and labour for submain wiring with 2 runs 4 sqmm single core, PVC insulated unsheathed, multistranded copper conductor FRLSH cable 1100 volts grade drawn through PVC conduit with all accessories on surface, one run of 4 sqmm cable single core PVC insulated, unsheathed, 1100 Volts grade multistranded copper conductor FRLSH cable as earth continuity conductor and making good the disturbed surface to match with the existing complete all as specified and directed. Note :- Two runs of 4 sqmm size PVC copper cable, One run of 4 sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length.
Supply and fixing metal plug and socket with MCB SPN 20 Amps and metallic P&S all as specified and directed.
S&F bell push modular 6 Amps, 1 module all as specified and directed.
S&F modular type sockets 6 amp-2/3 pin combined 2 module complete all as specified & directed.
S&F switch modular typr, single pole, 6 Amps, one way all as sper specified and directed.
S&F Modular sockets 6 Amp/16 Amps, 2/3 pin combined 2 module complete all as specified.
S&F switch modular type 1 module, 16 Amps, one way all as per specified and directed.
S&F ceiling rose surface bakelite 65 x 50 mm 3 terminals 240 Volt 50 Hz complete all as specified and directed.
S&F electric bell, AC 230V, single pole complete all as specified and directed.
S&F modular fan step regulator 120 W, 240 V, complete alll as specified and as directed.
S&F ceiling fan, curved blade, colour pearl white silver complete with accessories 230 V, 1200 mm sweep, BEE 5 star rated model - Troika of havells or equivalent Crompton, Bajaj, Orient, complete alll as specified and as directed.
Material and labour for submain wiring with 2 runs of 10 sqmm single core, PVC insulated unsheathed, multistranded copper conductor FRLSH cable 1100 volts grade drawn through PVC conduit with all accessories on surface, one run of 10 sqmm cable single core PVC insulated, unsheathed, 1100 Volts grade multistranded copper conductor FRLSH cable as earth continuity conductor and making good the disturbed surface to match with the existing complete all as specified and directed. Note :- Two runs of 10 sqmm size PVC copper cable, One run of 10 sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length.
S&F sheet metal enclosure MCB SPN DB 8 way double door (metal door) IP 43 type suitable for 200 Amp, 240 Volts, 50 Hz including all electrical connection all as specified and as directed.
S&F MCB SPN 40 A, 240 Volt, 50 Hz all as specified and directed. Cat part No. AU10S20403B of L&T or Indoasian, Legrand, complete alll as specified and as directed.
S&F MCB SP 6 to 32 Amp 240 Volt, 50 Hz all as specified and directed. Cat part No-DCMJCSPF006-032 of havells or equivalent Indoasian, L&T,complete alll as specified and as directed.
S&F ventilation fan 250 mm, 230 volt, 50 hz, 25 watt, RPM 1350 with suitable connection and cutting of wall and making good the disturbed surface to match with existing surface all as specified and directed. Model Name - Ventil Air-Dx White of havells or equivalent bajaj, crompton complete alll as specified and as directed.
S&F decorative wall mounted light fixture made up of metal, including LED bulb Candle type led bulb 5 Watt all as specified and directed .
S&F decorative wall mounted light fixture made up of metal, including LED bulb Candle type led bulb 5 Watt all as specified and directed .
S&F led pearl square recessed LED flat panel 18 watt, 240 Volt, 50 Hz all as specified and directed cat part no-LSCRM-18W-CDL of crompton or equivalent bajaj, crompton complete alll as specified and as directed.
S&F reading lamp my living beside lights LED 3 watt, 150 lumen 3000k, all as specified and directed cat part no - 48042/30/31 of philips or equivalent bajaj, crompton complete alll as specified and as directed.
ANIE JOHN CONTRACTORS
VIJAY CONSTRUCTIONS
Aarjay Tech Engineering
K.V.GEORGE AND COMPANY
Classic Builders
AMRITH ENGINEERS
WELTRONENGINEERINGSERVICES
Anaswara Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .