Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED | |
| 2 | L2₹36.7 L+₹78,050.60 (2.18%)Rejected-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹41.1 L+₹5.2 L (14.6%)Rejected-AOC 00 KAMALWAGANJA ROAD NEAR HANUMAN MANDIR HARINAGAR SHIV PURAM PHASE 1 HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| Sl No | Description | Qty | Unit | BK CONSTRUCTION L2 | Abhishek Enterprises L1 | M/S K K ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00Repair,maint including comprehensive preventive maintenance of DG set, including replacement of defective parts, filters, V-belt etc, decanning of the used engine oil from DG set by opening of drain out plug/nuts, cleaning of engine oil sump complete and refilling of new approved grade of engine oil as per requirement. Complete inspection and cleaning of DG set and rectified the all defects, tightening the all nuts, bolts, moving parts etc complete all as specified and directed of the following capacity. Notes : (i) Spare parts, 'V' - Belt, Filters, Air cleaner, hose, Engine Oil etc shall be measured and paid separately. (ii) Any Minor items like washer, gasket, nuts, bolts, 'O' Ring etc other than spare parts maintained in the respective Sch if required during maintenance of work, they shall be provided by the contractor and rate deemed to be included in the item rate for which no extra payment shall be paid. (iii) Periodicity of maintenance of DG set shall be carried out as per following instruction : (a) by check oil level and quality (Every 50-100 hours or as recommended by manufacturer) (b) Inspect air fltrer (Every 100 - 200 hours or as recommended by manufacturer) (c) Check fuel system (Every 100 -200 hours or as recommended by manufacturer) (d) Inspect cooling system (every 200 - 500 hours or as recommended by manufacturer). | ||||||
| 1.01(e) Check battery (every 200 - 500 hours or as recommended by manufacturer) (f) Inspect exhaust (every 500 - 1000 hours or as recommended by manufacturer) (g) Check electrical system (every 500 - 1000 hours or as recommended by manufacturer) (h) Load test (every 500 - 1000 hours or as recommended by manufacturer) (j) Inspect engine and generator mounts (every 500 - 1000 hours or as recommended by manufacturer) (h) Perform general inspection (every 1000 - 2000 hours or as recommended by manufacturer) and when required/ directed by Engr-in-Charge. Measurement shall be carried out as per maint carried out by the Contractor. (iv) Maint shall be carried out in the present of Engr-in-charge/Rep of Engr-in-charge. (v) Maint shall be carried out through service centre of original equipment manufacturers/Auth Service centre of DG set. (vi) All tool and plants shall be provided by the contractor. (vii) Contractor shall maintain proper documents of DG set wise pertains to maint carried out and submitted to the Engr-in-charge as & when maint carried out. | ||||||
| 1.02 | (a) Capacity of DG Sets 160 KVA. | 1 | EACH JOB | 5,500 ₹5,500 Lowest | 6,500 ₹6,500 | 5,600 ₹5,600 |
| 1.03 | (b) Capacity of DG Sets 100/125 KVA. | 5 | EACH JOB | 4,500 ₹22,500 Lowest | 6,500 ₹32,500 | 4,500 ₹22,500 Lowest |
| 1.04 | (c) Capacity of DG Sets 30/35 KVA. | 2 | EACH JOB | 4,000 ₹8,000 Lowest | 4,500 ₹9,000 | 4,000 ₹8,000 Lowest |
| 1.05 | (d) Capacity of DG Set upto 15 KVA. | 1 | EACH JOB | 3,500 ₹3,500 | 3,000 ₹3,000 Lowest | 3,500 ₹3,500 |
| 2.00 | Repair / Maint of existing control panel of DG Set by replacing the connected items such as Connectors, leads, copper wire, thimble, digital multifunction meter, control wiring etc along with any other items requierd to be replaced as directed by E-in-Charge. | 5 | EACH | 6,500 ₹32,500 Lowest | 6,500 ₹32,500 Lowest | 7,500 ₹37,500 |
| 3.00 | M&L for cleaning of fuel tank of DG sets of any make and capacity including replacement of fuel level indicating tube and markings complete all as specified and directed. | 9 | EACH JOB | 3,500 ₹31,500 | 1,345 ₹12,105 Lowest | 3,500 ₹31,500 |
| 4.00 | Replacement of flame proof asbestos rope of specified dia wrapped around the exhaust pipe complete all as specified and directed. | 10 | KG | 350 ₹3,500 Lowest | 390 ₹3,900 | 350 ₹3,500 Lowest |
| 5.00 | Taking out unserviceable charging alternator from 100 KVA to 160 KVA DG set and removing starter and rotor, removing old burnt out winding wire and rewinding the stator of suitable size with super enameled copper wire and insulating materials complete including re-assembling the complete alternator, fixing in position and testing on load complete including replacement of bearing of suitable size – 01 Set complete all as specified and directed. | 2 | EACH JOB | 25,000 ₹50,000 | 18,550 ₹37,100 Lowest | 35,000 ₹70,000 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
20 May 2026, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR REPLACEMENT AND IMPROVEMENT IN MAINTENANCE OF STP EQUIPMENTS DG SETS FIRE FIGHTING EQUIPMENTS AT MIL STN GANDHINAGAR
2026_MES_757553_2
GE(A)/GNR/TOKEN/06 of 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹80,000
Yes
28 Jul 2026
5 May 2026
22 May 2026
5 May 2026
20 May 2026
14 May 2026
5 May 2026 - 12 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Repair,maint including comprehensive preventive maintenance of DG set, including replacement of defective parts, filters, V-belt etc, decanning of the used engine oil from DG set by opening of drain out plug/nuts, cleaning of engine oil sump complete and refilling of new approved grade of engine oil as per requirement. Complete inspection and cleaning of DG set and rectified the all defects, tightening the all nuts, bolts, moving parts etc complete all as specified and directed of the following capacity. Notes : (i) Spare parts, 'V' - Belt, Filters, Air cleaner, hose, Engine Oil etc shall be measured and paid separately. (ii) Any Minor items like washer, gasket, nuts, bolts, 'O' Ring etc other than spare parts maintained in the respective Sch if required during maintenance of work, they shall be provided by the contractor and rate deemed to be included in the item rate for which no extra payment shall be paid. (iii) Periodicity of maintenance of DG set shall be carried out as per following instruction : (a) by check oil level and quality (Every 50-100 hours or as recommended by manufacturer) (b) Inspect air fltrer (Every 100 - 200 hours or as recommended by manufacturer) (c) Check fuel system (Every 100 -200 hours or as recommended by manufacturer) (d) Inspect cooling system (every 200 - 500 hours or as recommended by manufacturer). | |||||
| 1.01 | (e) Check battery (every 200 - 500 hours or as recommended by manufacturer)
(f) Inspect exhaust (every 500 - 1000 hours or as recommended by manufacturer)
(g) Check electrical system (every 500 - 1000 hours or as recommended by manufacturer)
(h) Load test (every 500 - 1000 hours or as recommended by manufacturer)
(j) Inspect engine and generator mounts (every 500 - 1000 hours or as recommended by manufacturer)
(h) Perform general inspection (every 1000 - 2000 hours or as recommended by manufacturer) and when required/ directed by Engr-in-Charge. Measurement shall be carried out as per maint carried out by the Contractor.
(iv) Maint shall be carried out in the present of Engr-in-charge/Rep of Engr-in-charge.
(v) Maint shall be carried out through service centre of original equipment manufacturers/Auth Service centre of DG set.
(vi) All tool and plants shall be provided by the contractor.
(vii) Contractor shall maintain proper documents of DG set wise pertains to maint carried out and submitted to the Engr-in-charge as & when maint carried out. | - | - | - | - |
| 1.02 | (a) Capacity of DG Sets 160 KVA. | 1 | EACH JOB | - | - |
| 1.03 | (b) Capacity of DG Sets 100/125 KVA. | 5 | EACH JOB | - | - |
| 1.04 | (c) Capacity of DG Sets 30/35 KVA. | 2 | EACH JOB | - | - |
| 1.05 | (d) Capacity of DG Set upto 15 KVA. | 1 | EACH JOB | - | - |
| 2 | Repair / Maint of existing control panel of DG Set by replacing the connected items such as Connectors, leads, copper wire, thimble, digital multifunction meter, control wiring etc along with any other items requierd to be replaced as directed by E-in-Charge. | 5 | EACH | - | - |
| 3 | M&L for cleaning of fuel tank of DG sets of any make and capacity including replacement of fuel level indicating tube and markings complete all as specified and directed. | 9 | EACH JOB | - | - |
| 4 | Replacement of flame proof asbestos rope of specified dia wrapped around the exhaust pipe complete all as specified and directed. | 10 | KG | - | - |
| 5 | Taking out unserviceable charging alternator from 100 KVA to 160 KVA DG set and removing starter and rotor, removing old burnt out winding wire and rewinding the stator of suitable size with super enameled copper wire and insulating materials complete including re-assembling the complete alternator, fixing in position and testing on load complete including replacement of bearing of suitable size – 01 Set complete all as specified and directed. | 2 | EACH JOB | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_855259.xls
BOQ • 0.52 MB
TenderDocuments.pdf
Tender Documents • 1.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .