Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹43.4 LAccepted-AOC D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹48.5 L+₹3.5 L (7.88%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹49.9 L+₹5.0 L (11.1%)Rejected-Finance D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹53.8 L+₹8.9 L (19.8%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹55.8 L+₹10.8 L (24.1%)Rejected-Finance | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Sept 2023, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
PERIODICAL MAINT AND REPAIR TO SPLIT ACS, CASSATE TYPE ACS AND DUCTABLE/PACKAGE TYPE ACS UNDER GE (NB) VISAKHAPATNAM
2023_MES_613876_1
C/8230/23-24/E8 / Token 71 of 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹90,000
Yes
20 Feb 2024
16 Aug 2023
15 Sept 2023
16 Aug 2023
13 Sept 2023
30 Aug 2023
Amount
Taking Down, defective / unserviceble hermetically sealed Compressor of scroll type, 3 phase, 415 voits of ductable, package type AC units, 8.6/ 7.5 TR Capacity including de-brazing the suction & discharge lines, disconnecting the cable connection etc., replacing the compressor with new compressor, fixing it to the unit, brazing and interconnecting the refrigeration lines with necessary copper pipe, copper and silver rods, sockets, elbows, flushing the refrigeration lines, condenser, evaporator with Nitrogen gas, pressure testing, checking of leaks, holding the pressure for 24 Hrs vaccumising the complete system, purging with refrigerant gas, de-hydrating and charging of R-410A & R-134A gas, testing & commissioning complete all as specified and as directed. (Note : (i) Make & Specifications of compressor shall be as per existing one. (ii) Supply only gas R-410A & R-134A shall be measured and paid separately under relevant item. (iii) Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any))
All as per Serial item No. 01 above but for AC unit of 3.5/5.5 TR capacity complete ditto
Material & Labour for replacement of rusted body portions of Ductable / Cassette type Air Conditioning units, 3.5 / 5.5 / 5.8 TR Capacity with the existing material of same thickness like M.S. Sheet, Angle Iron, tinkering the partially corroded portion matching to the existing shape & size, including bending, welding / brazing and removing the existing foam pad, scraping out the old paint of the body, cleaning the surface thoroughly, apply two coats of synthetic enamel paint over one coat of red oxide primer and refixing all the components, renew all the corroded bolt & nuts connecting up all the electrical connections testing and commissioning complete all as specified and as directed. (Note: Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any))
All as per Serial item No. 03 above but for 8.6/7.5 TR capacity ductable ACs complete ditto.
S & F new condenser fan blades for the ductable / cassette type ACs of 3.5/ 5.5 TR capacity including balancing for smooth rotation in casing and testing including taking down the damaged condenser fan blades complete all as specified and as directed.
All as per Serial item No. 05 above but for 8.6/7.5 TR capacity ductable ACs complete ditto.
S & F in repairs indoor blower for 3.5 / 5.5 TR Ductable AC’s as per the existing make and specifications complete all as specified and as directed.
All as per Serial item No. 07 above but for 8.6/7.5 TR capacity ductable ACs complete ditto.
S & F in repairs Power contactor, 3 pole, 415 Volts, 50 Hz coil voltage with auxiliary contact NO/AC with necessary wiring and testing suitable for 3.5 / 5.5/7.5 TR Ductable AC’s complete all as specified and as directed.
S & F in repairs electronic Control Card i.e PCB boards suitable for 3.5 / 5.5 TR Ductable AC’s as per the existing make and specifications and making connections etc complete all as specified and as directed. (Make: LG/Blue Star/Carrier/Voltas)
All as per Serial item No. 10 above but for 8.6/7.5 TR capacity ductable ACs complete ditto.
Material & Labour for taking down the burnt single phase fan motor of outer unit and rewinding the motor including renewal of the bearing / bushes, repair to shaft assembly, fixing back to units and testing & commissioning of 7.5/5.5/ 3.5TR Ductable AC Units complete all per existing specifications and as directed. (Note: Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any))
S & F in repairs bimetal over load relay suitable for 3.5 / 5.5 TR Ductable AC’s as per the existing make and specifications and making connections etc complete all as specified and as directed.
All as per Serial item No. 13 above but for 8.6/7.5 TR capacity ductable ACs complete ditto.
All as per Serial item No. 13 above but for 8.6/7.5 TR capacity ductable ACs complete ditto.
M & L for cleaning / flushing out the refrigeration system thoroughly with CTC and Nitrogen, leak testing, rectification of leak by brazing with Silver / copper rods, pressure testing, dehydrating, vaccumising and charging R-22/R-32 gas and testing commissioning of 3.5/ 5.5 / 7.5 TR capacity ductable/Cassete type ACs complete all as specified and as directed. (Note: (i) R-22 gas shall be measured and paid separately under the relevant item here-in-below ( (ii) Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any)).
S & F in repairs Thermostatic expansion valve suitable for 3.5/5.5/7.5 TR capacity ductable Split ACs complete as per the existing make and specifications and as directed.
S & F in repairs Connector strip suitable for 3.5/5.5/7.5 TR capacity ductable Split ACs complete as per the existing make and specifications and as directed.
S & F in repairs Micro fine filter suitable for 3.5/5.5/7.5 TR capacity ductable Split ACs complete as per the existing make and specifications and as directed.
M & L for taking down the burnt out fan motor upto 1.5 HP, single phase of the evaporator unit (indoor unit) and rewinding the stator with same gauge super enameled copper wire, varnishing and renewal of worn out 2 Nos. bearings, re-assembling, fixing to the unit, testing & commissioning the AC unit of 3.5/ 5.5 TR capacity Ductable AC’s complete all as specified and as directed. (Note: Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any))
All as per Serial item No. 20 above but for 8.6/7.5 TR capacity ductable ACs complete ditto.
All as per Serial Item No. 20 above but for out door condensing unit fan motor of 1HP for 3.5/5.5 TR capacity Ductable AC’s complete ditto.
All as per Serial item No. 20 above but for 7.5/8.6 TR capacity ductable ACs complete ditto.
S & F in repairs Temperature sensor probe suitable for ductable/cassete type Acs any capacity complete as per the existing make and specifications and as directed.
M & L for carryout the servicing of indoor unit of Ductable / Cassette type AC Unit including chemical cleaning to the evaporator coil with Non-Acidic type coil cleaning chemical agent, apply to the coil, remove the complete scale deposit on the evaporator coil, flushing through coil fins area and complete cleaning the coil tray and fixing all the removed parts, and testing & commissioning ductable cassette AC’s indoor unit of 3.5/5.5 TR Cassette type ACs complete all as specified and as directed. (Note: Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any)).
All as per Serial item No. 25 above but for 8.6/7.5 TR capacity ductable ACs complete ditto.
All as per Serial item No. 25 above but for out door condensing units for 3.5/5.5 TR Capacity Ductable ACs complete ditto
All as per Serial item No. 25 above but for outdoor condensing units of 8.6/7.5 TR capacity ductable ACs complete ditto.
M & L for taking down the defective remote control unit of the ductable / Cassette type AC units capacities of 3.5/5.5/ 7.5 TR and carryout the repair by replacing the defective electronic parts like diodes, transformer, coils, cable sets, printed circuits etc. including necessary wiring and connecting up to the system and testing & commissioning complete all as per the existing specifications and as directed.
S & F in repairs PVC pipe, 25mm dia as in drain pipe including 6mm foam insulation with necessary adhesive and necessary fittings such as elbow/bends/clamps etc of suitable size complete all as specified and as directed.
SPLIT ACs M & L for taking down defective split type AC unit, shifting to work shop, taking out the defective compressor of capacity 1.5 T capacity from unit, replacing the compressor with new compressor, refixing the compressor to the unit, cleaning refrigeration system with CTC thoroughly, leak testing with refrigerant gas, testing at workshop, shifting to location, re-installing the same in its original position, connecting up all electrical connections, testing and commissioning complete all as per existing make and specifications and as directed. (Note : Rate quoted is deemed to be inclusive of cutting, brazing, sealing the refrigeration tubing, replacement of strainer, cost of CTC, refrigerant gas and CO2 etc., required for the job including transportation to worshop and back to site.) (Make: Carrier/LG/Samsung/Sriram/Voltas/KIrloskar/Techamsa/Bluer Star)
All as per Serial Item No. 31 above but for 2.0 T capacity split Acs complete ditto
S & F in repairs Air cooled Condenser assembly including pipes connections and brazing to the units for 1.5/2.0 Ton Ccapacity Split ACs complete all as per existing make and specifications and as directed.
M & L for replacement of rusted body portions of split type AC unit of 1.5 / 2 / 3 Ton capacity with same gauge / size materials like MS sheet, angle iron similar to the existing one by removing existing foam pad and components and scraping out old paint on complete body, cleaning surface thoroughly, Appling two coats synthetic enamel paint of approved shade over a coat of red oxide primer, fixing of new foam pad of not less than 3mm thick, refixing of all components, installation in original position, connecting up all electrical connections, testing and commissioning complete all as specified and as directed. (Note: Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any))
S & F in repairs condenser fan blades of 1.5/2.0/3.0 Ton capapcity split Acs, balancing for smooth rotation in the casing and testing complete all as per existing make and specifications and as directed. (Make: Carrier/Voltas/Amtrex/Blue Star)
M & L for scrapping the existing painting of the complete body of out door unit metallic surfaces, cleaning the surface thoroughly, applying two coats of approved synthetic enamel paint over a coat of red oxide primer for 1.5 / 2/3 Ton capacity split type ACs complete all as specified and as directed.
S & F in repairs Power contactor, single pole, 415 Volts, 50 Hz coil voltage suitable for 1.5/2.0 Ton capacity Split ACs complete all as specified and as directed.
M & L for replacement of thermal insulation suitable for Split ACs of capacity 1.5/2.0/3.0 Ton complete all as existing specifications and as directed.
M & L for cleaning / flushing out the refrigeration system thoroughly with CTC, leak testing with CO2 / N2 locating and rectifying the leaks by brazing with silver / copper rod, pressure testing, vaccumising and charging with refrigerant gas and topping up compressor oil, testing and commissioning complete for split type ACs of 1.5 Ton capacity complete all as specified and as directed. (Note : (i) Supply only refrigerant gas will be measured and paid separately. (ii) Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any)).
All as per Serial item No. 39 above but for 2.0/3.0 Ton capacity Split Acs complete ditto.
S & F in repairs Temperature sensor probe in the main circuit suitable for 1.5/2.0/3.0 Ton capacity split ACs complete as per the existing make and specifications and as directed.
S & F in repairs PCB Cord suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs, non Inverter type complete as per the existing make and specifications and as directed.
S & F in repairs PCB Cord suitable for 1.5/2.0 Ton capacity split ACs/tower ACs, Inverter type complete as per the existing make and specifications and as directed.
S & F in repairs Remote controller suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs, complete as per the existing make and specifications and as directed.
Taking down the burnt out fan motor of evaporator unit and rewinding the motor with appropriate gauge copper wire including varnishing and replacement of worn out shaft, bushes, bearings, reassembling the unit, testing and fixing to the split ACs/tower ACs indoor unit of capacity 1.5 / 2 / 3 Ton complete all as specified and as directed. (Note : Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any)).
All as per Serial item No. 45 above but for outdoor unit of 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete ditto.
S & F in repairs thermal over load relay suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs all as per the existing make and specifications and as directed.
M & L for complete chemical servicing of the indoor and out door unit with appropriate chemical agent and flushing out the fins area and blowing out water and dust and lubricating of fan bush / bearing and checking of all electrical connections, testing and commissioning of 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed. (Note : Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any)).
S & F in repairs Running capacitor of 45 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed. (Make: Sarada/Unistar/Crompton)
S & F in repairs Starting capacitor of 50 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed. (Make: Sarada/Unistar/Crompton)
S & F in repairs Starting capacitor of 80/100 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed. (Make: Sarada/Unistar/Crompton)
S & F in repairs indoor/outdoor unit fan motor capacitor of 4/6 MFD suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs complete all as specified and as directed. (Make: Sarada/Unistar/Crompton)
S & F in repairs fine filter suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs all as per the existing make and specifications and as directed.
S & F in repairs Drain connection with drain trap suitable for 1.5/2.0/3.0 Ton capacity split ACs/tower ACs all as per the existing make and specifications and as directed.
S & F in repairs copper suction and liquid line including brazing and pressure testing suitable for 1.5/2.0/3.0 Ton capacity Split ACs all as per the existing make and specifications and as directed.
S & F in repairs wiring kit suitable for 1.5/2.0/3.0 Ton capacity Split ACs all as per the existing make and specifications and as directed.
S & F in repairs evaporated fan blower of double inlet, double width, centrifugal type suitable for 1.5/2.0/3.0 Ton capacity Split ACs all as per the existing make and specifications and as directed.
S & F in repairs PVC pipe, 20mm dia as in drain pipe including necessary fittings such as elbow/bends/clamps etc of suitable size fixed to wall or ceiling complete all as specified and as directed.
Taking down the unserviceable service valve of suction and liquid line and supply and fix new service valve suitable for 1.5 / 2.0/3.0 Ton capacity split type ACs including necessary nut & bolts, gaskets and brazing to the respective line with silver / copper rod and checking for the leakage complete all as per existing make and specifications and as directed.
S & F in repairs delivery/discharge valve suitable for 1.5/2.0/3.0 Ton capacity Split ACs all as per the existing make and specifications and as directed.
S & F in repairs capillary tube set suitable for 1.5/2.0/3.0 Ton capacity Split ACs all as per the existing make and specifications and as directed.
S & F in repairs MS stand for mounting outdoor unit of Split Acs of capacity 1.5/2.0/3.0 Ton complete all as per the existing make and specifications and as directed.
S & F in repairs copper tubing of 5/8" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs copper tubing of 3/8" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs copper tubing of 1/4" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs copper tubing of 1/2" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs copper tubing of 11/8" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs copper tubing of 7/8" dia suitable for suction/discharge line of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs Insulation for copper tubing of 5/8" dia of Split ACs complete all as per the existing make specification and as directed
S & F in repairs Insulation for copper tubing of 3/8" dia of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs Insulation for copper tubing of 1/4" dia of Split ACs complete all as per the existing make specification and as directed.
S & F in repairs Insulation for copper tubing of 1/2" dia of Split ACs complete all as per the existing make specification and as directed.
S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 2.5 sqmm complete all as specified and as directed.
S & F in repair Three core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 4 sqmm complete all as specified and as directed.
S & F in repair Four core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 2.5 sqmm complete all as specified and as directed.
S & F in repair Four core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 4 sqmm complete all as specified and as directed.
Taking down fan blower motor from air conditioner of any make/type of 1.5 Ton capacity and replacing the same with new motor of same rating, with copper winding, single phase, 200/230 volt, 50 Hz, in the same position and testing etc complete all as specified and as directed. (Make : VOLTASAUE/ELECTRA).
All as per Serial item No. 77 above but for 2.0 Ton capacity ACs complete ditto.
S & F in repairs fan motor, ISI marked for indoor unit of split type air conditioner of any make / type and capacity and making connection etc complete all as per the existing make and specifications and as directed.
S & F in repairs fan motor, ISI marked for outdoor unit of split type air conditioner of any make / type and capacity and making connection etc complete all as per the existing make and specifications and as directed.
M & L for Repairs to voltage stabiliser of any make / phase with input voltage 135-190V and output voltage 200-240 Volts, capacity upto 5 KVA by dismantling and taking our burnt main transformer and rewinding with suitable guage super enamelled copper wire, varnishing, etc., complete including replacement of unserviceable/defective voltmeter, 0-300 volts complete all as specified and as directed. (Make of voltmeter : AE/Primer) (Note: Unit quoted rate shall deemed to be inclusive of transportation cost to workshop and back (if any))
Supply only R134A/R32/R410A/R600 Gas for all types of AC Units complete all as specified and as directed.
Taking down unserviceable Split type ACs of any capacity/type after disconnecting all connections etc and re-fixing in the same position or any other specified position as directed by the Engr-in-Charge after carry out repairs works, filling of gas etc complete all as specified and as directed.
SATYAM ENGINEERS
SRIVALLI ENGINEERS
LAKSHMI SAI CONSTRUCTIONS
SRI SIDDHI VINAYAKA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .