Loading…
Loading…
Tender Value
₹5 Cr
EMD Value
₹5 L
Closing Date
6 May 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
COMMISSIONER JUNAGADH MUNICIPAL CORPORATION
Rate Contract for Design, Supply, Installation, Testing and Commissioning of Grid-connected rooftop solar power plant System with related comprehensive Electrical, Mechanical & Civil Work including all necessary equipment and Auto Cleaning System as per tender specification with comprehensive O & M at Diffrent site of Municipal Corporation Junagadh for two year
296854
JuMC/Street Light/01/2026-27
Open
Electrical Works
Junagadh
12 documents required · 12 mandatory
₹6,000
Commissioner, Municipal Corporation Junagadh
₹5 L
15 Apr 2026
15 Apr 2026
15 Apr 2026
6 May 2026
15 Apr 2026
Name of Work ::- ::- Rate Contract for Design, Supply, Installation, Testing and
Commissioning of Grid-connected rooftop solar power plant System with related
comprehensive Electrical, Mechanical & Civil Work including all necessary equipment and
Auto Cleaning System as per tender specification with comprehensive O & M at Diffrent site
of Municipal Corporation Junagadh for two year.(Excluding GST)
TEAM COST OF TOTAL
ITEAM DISCRIPATION QNT UNIT MATERIA
LABOUR AMOUNT (5+6)
14.1.1Supply, Installation, Testing & Commissioning of following
size of Grid Tied Solar Power Plant with
Solar Panels (ALMM approved): Frame Material :
Anodized Aluminum alloy Frame With Twin Wall Profile,
Front Cover : High Transmission Low-Iron Tempered Glass
(AR Coated), High efficency and positive power tolerance
Pmax: 0/+5, Module Efficiency should be approx. 19.5%-
22%, Normal operating temperature 45'C, Junction Box
with Waterproof IP67 & MC4 Compatible and Enclosed
with Bypass diodes, 100% Electroluminescence test to
ensure error free Modules, Thep. temp. co-efficient of the
PV module shall equal or better than -0.45%/degree C.
Solar PV modules of minimum fill factor 75% to be used.
Unit Production:- More than 4.5 Unit /kw /day
(Actual)(1Year Avg) With 10 year Product warranty and
year Linear Power Warranty includes all mechanical and
electrical parameters of the Solar panel. Modules must be
complied to the DCR(Domestic content requirements). The
Ration of AC to DC is 5:6 for the Installation capacity which
are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max
efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating
Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%,
Operating Tempreture Range: -25~60°C, Integrated protection
of Inverter are Anti-islanding Protection, Input Reverse
Polarity Protection, Insulation Resistor Detection, Ground fault
protection, Residual Current Monitoring Unit, Output Over
Current Protection, Output Short Circuit Protection, Output
Over Voltage Protection, PV array string fault Protection.
Protection Degree: IP65, User Interface LCD & APP,
Datalogger & Communication: GPRS / Wi-Fi.
Integrated, Input Reverse Polarity Protection Integrated, Insulation
Resistor Detection Integrated, Residual Current Monitoring Unit
Integrated, Output Over Current Protection Integrated, Output
Short Circuit Protection Integrated, Output Over Voltage Protection
Integrated, Protection Degree: IP65, User Interface LCD &
APP,Datalogger & Communication: GPRS / Wi-Fi, Module
Mounting Structure: The mounting (Rectangular pipe / square pipe
/ circular pipe) with requisite cross bars, nuts and bolts, etc. shall
be Hot deep galvanized with minimum 80micron coating. The
Rectangular / square /circular hollow pipe section used for the
structure should have a minimum thickness of 2.0 mm. other than
above, the material thickness should be minimum 2.5 mm. A
certificate of a structural engineer certifying the strength and
stability of the mounting structure to withstand the weight and wind
speed of 150 km/hour throughout the life span of 25 years of the
system, shall be submitted by the vendors. Hot Dipped Galvanized
steel coils. suitable arrangement for base plate for foundation
solar panel mounting, the structure should be suitable for carry the
load of solar panel,wiring, sprinkler system etc. with necessary
foundation work/wall mount, j bolt, anchor fastner etc. the nut bolt
used for installtion of stucture should be (SS 304) quality.The
ground clearance of the bottom most edge of solar panel shall not
be less than 300 mm to 1200 mm or as per site’s
technical/feasibility requirement.a. Column –The minimum section
(thickness) should be 60MM*40MMb. Rafter - The minimum
section (thickness) should be 60MM*40MMc. Purlin - The
minimum section (thickness) should be 40MM * 40MM Balane of
System with necessary Swichgears (Suitabel size and protection
of ACDB & DCDB), inter connecting wiring, earthing system as per
the CEIG drawing approval, lightining arrester system as per the
CEIG drawing approval, all liasoning work with various gov.
dipartment like state nodal agency,DISCOM & CEIG is included in
(Excluding All charges namely GEDA Application
fees, Solar connectivity Charges, Meter connectivity
Charges, Meter testing Charges and system
stability/strenthning charges.)
(A) Grid Tied Solar Power System: 1 - 6 kW (Single 1 PER 52500.00 2000.00
(B) Grid Tied Solar Power System: 7 - 10 kW (3 - 1 PER 49500.00 2000.00
(C ) Grid Tied Solar Power System: 11 - 25 kW (3 - 1 PER 47800.00 1800.00
(D) Grid Tied Solar Power System: 26 - 50 kW (3 - 1 PER 47500.00 1750.00
(E) Grid Tied Solar Power System: 51 - 100 kW (3 - 1 PER 46000.00 1500.00
(F) Grid Tied Solar Power System: 101 - 250 kW (3 - 1 PER 45000.00 1500.00
(G) Grid Tied Solar Power System: 251 - 500 kW (3 - 1 PER 44500.00 1250.00
PART-2 SOLAR PANEL
1 (A) Moudule o/p Range: 250 - 335 watt, Maximum 1 PER 31.00 1.50
Power Voltage Vmpp: 26 -38 V, Maximum Power WATT
Current Impp: 8 - 8.9 A
(B) Moudule o/p Range: 365 - 390 watt, Maximum 1 PER 33.00 2.00
Power Voltage Vmpp: 39 - 40 V, Maximum Power WATT
Current Impp: 9 - 10 A
(C) Moudule o/p Range: 435 - 455 watt, Maximum 1 PER 34.00 2.00
Power Voltage Vmpp: 40 - 42 V, Maximum Power WATT
Current Impp: 10.5 - 11 A
(D) Moudule o/p Range: 480 - 505 watt, Maximum 1 PER 35.00 2.00
Power Voltage Vmpp: 41 - 42 V, Maximum Power WATT
Current Impp: 12 - 13 A
(E) Moudule o/p Range: 520 - 545 watt, Maximum 1 PER 36.00 2.00
Power Voltage Vmpp: 41 - 42 V, Maximum Power WATT
Current Impp: 12.5 - 13 A
PART - 3 INVERTERS
14.3. S.I.T.C of Solar Inverter Gried Tied: MPPT Range: 80-
1 1000 V, Max efficiency: 97.5% - 98.9%, O/p
Frequency: 50/60Hz, Operating Altitude (m) ≤4000,
O/p Power Factor: ~1, O/P THDi: <3%, Operating
Tempreture Range: -25~60°C, Anti-islanding
Protection: Integrated, Input Reverse Polarity
Protection Integrated, Insulation Resistor Detection
Integrated, Residual Current Monitoring Unit
Integrated, Output Over Current Protection
Integrated, Output Short Circuit Protection Integrated,
Output Over Voltage Protection Integrated, Protection
Degree: IP65, User Interface LCD & APP,Datalogger
& Communication: GPRS / Wi-Fi (Optional)
(A) Solar Inverter: 1 kW to 3 kW: Max. input Current: 1 Per 9.50 1.00
10A, Max DC i/p Power: 1300-3900W & Nominal o/p Watt
Power: 1000-3000W Nomimal O/p Voltage: 220/230
V 1-Phase, Nominal O/p Current: 5-13.5A.
(B) Solar Inverter: 3 kW to 6 kW: Max. input Current: 1 Per 9.50 1.00
11A, Max DC i/p Power: 3900-7200W & Nominal o/p Watt
Power: 3000-6000W, Nomimal O/p Voltage: 220/230
V 1-Phase, Nominal O/p Current: 13.6-27.3A.
(C) Solar Inverter: 6 kW to 15 kW: Max. input 1 Per 8.50 1.00
Current: 22 A, Max DC i/p Power: 7800-19500 W & Watt
Nominal o/p Power: 6000-16500 W, Nomimal O/p
Voltage: 400 V 3-Phase, Nominal O/p Current: 10-
(D) Solar Inverter: 15 kW to 25 kW: Max. input 1 Per 8.50 1.00
Current: 27 A, Max DC i/p Power: 22100-32500W & Watt
Nominal o/p Power: 15000-25000W, Nomimal O/p
Voltage: 400 V 3-Phase,Nominal O/p Current: 25-
(E) Solar Inverter: 25 kW to 50 kW: Max. input 1 Per 7.50 1.00
Current: 30 A, Max DC i/p Power: 22100-51500 W & Watt
Nominal o/p Power: 25000-50000W, Nomimal O/p
Voltage: 400 V 3-Phase,Nominal O/p Current: 37-
(F) Solar Inverter: 50 kW to 100 kW: Max. input 1 Per 7.50 1.00
Current: 40 A, Max DC i/p Power: 66500-130500 W & Watt
Nominal o/p Power: 50000-100000 W, Nomimal O/p
Voltage: 400 V 3-Phase,Nominal O/p Current: 80-144
(G) Solar Inverter: 100 kW to 136 kW: Max. input 1 Per 7.50 1.00
Current: 40 A, Max DC i/p Power: 130.5 -176.5 KW & Watt
Nominal o/p Power: 100-136 KW, Nomimal O/p
Voltage: 540 V 3-Phase, Nominal O/p Current: 144-
(H) Solar Inverter: 136 kW to 200 kW: Max. input 1 Per 7.50 1.00
Current: 40 A, Max DC i/p Power: 176.5-260KW & Watt
Nominal o/p Power: 136-200KW, Nomimal O/p
Voltage: 540 V 3-Phase, Nominal O/p Current: 144-
PART - 4 STRUCTURE
14.4. Supplying and Erecting Seamless Box Pipe of 1 PER 150.00 2.00
suitable size for rooftop solar installations with good KG
stability agaist wind, Thickness 2 mm and 80 micron,
Hot Dipped Galvanized steel coils. suitable
arrangement for base plate for foundation , solar
panel mounting, the structure should be suitable for
carry the load of solar panel,wiring, sprinkler system
etc. with necessary foundation work/wall mount, j bolt,
anchor fastner etc. the nut bolt used for installtion of
stucture should be (SS 304) quality.
box. pipe ref. size (A) 40 x 40 x 2mm, (B) 50 × 50 ×
14.4. Supplying and Erecting 'C' Channel of suitable size 1 PER 175.00 2.00
for rooftop solar installations with good stability agaist KG
wind, Hot Dipped Galvanized steel coils. It have
suitable arrangement for base plate for foundation
Screw Arrangement , solar panel mounting, the
structure should be suitable for carry the load of solar
panel,wiring, sprinkler system etc. with necessary
foundation work/wall mount, j bolt, anchor fastner etc.
the nut bolt used for installtion of stucture should be
(SS 304) quality.
14.4. Supplying and Erecting Stainless Steel Nut Bolt (SS 1 Ea. 46.00 5.00
3 304) for Installation of Solar PV Module, Structures,
and other related items with required size as engineer
in charge demands for project Size, length upto 10 x
PART - 5 DC Cables
14.5. DC Cable: Electron beam cross linked compound,UV,
1 Ozone, Temperature & Hydrolysis resistant Flame
Retardant, Low Smoke Excellent Encapsulation
Very long / Service life >
Standards / Material Properties:
Fire performance : IEC 60332-1-2
Smoke emission : IEC 61034/ EN 50268-2
Halogen Free: EN 50267-2-1/-2, IEC 60754-2
Toxicity: EN 50305, ITC – Index <3
Ozone Resistant : EN50396
Weathering UV: HD 605/A1 or DIN
Approvals : EN 50618; H1Z2Z2-k
with suitable sized of PVC pipe(ISI Mark) and
Clamps,Shadels,Lugs.
(A) 1 core 4 sqmm copper DC cable Colour Red 1 PER 85.00 3.00
(B) 1 core 4 sqmm copper DC cable Colour Black 1 PER 85.00 3.00
14.6. S,I,T.C of Distribution board from AC Side, ACDB 1-
1 Phase - 1 kW - 6 kW: AC MCB: 16-25A, 2POLE, C-
CURVE, 10KA, AC SPD: 40KA, 1P+N,
TERMINAL/END PLATE/END CLAMP: 6SQMM
(KUT6) FOR OUTPUT, AC Interconnection with
suitable size wire/cable, All switchgears and
connection are enclosed with IP66 Enclosure which
have transperant cover in frontside to view and
operate the MCB position.
14.6. S,I,T.C of Distribution board from AC Side ,ACDB 3- 1 Ea. 7500.00 500.00
2 Phase - 6 kW - 10 kW: AC MCB 20-32A, 4POLE, C
10KA, AC SPD 40KA, 3P+N, TERMINAL/END
PLATE/END CLAMP: 6SQMM (KUT10) FOR
OUTPUT,AC Interconnection with suitable size
wire/cable. All switchgears and connection are
enclosed with IP66 Enclosure which have transperant
cover in frontside to view and operate the MCB
14.6. S.I.T.C of Distribution board from AC Side, ACDB 3- 1 Ea. 9000.00 700.00
3 Phase - 11 kW - 20 kW: AC1 DUTY
CONTRACTOR‐40A 4P,
100A MCCB 4P(Cat III), 3 PHASE SPD, VOLTAGE
MONITORING RELAY,
ELR WITH CBCT, PHASE INDICATING LAMP,
OTHER ACCESSORIES, All switchgears and
connection are enclosed with IP66 Enclosure and
operate the MCB position.
14.6. S.I.T.C of Distribution board from AC Side ,ACDB 3- 1 Ea. 20500.00 700.00
4 Phase - 21 kW - 50 kW: AC1 DUTY
CONTRACTOR‐80A 4P,
100A MCCB 4P(Cat III), 3 PHASE SPD, VOLTAGE
MONITORING RELAY,
ELR WITH CBCT, PHASE INDICATING LAMP,
OTHER ACCESSORIES, All switchgears and
connection are enclosed with IP66 Enclosure and
operate the position.
14.6. S.I.T.C of Distribution board from AC Side , ACDB 3- 1 Ea. 48500.00 1000.00
5 Phase - 51 kW - 100 kW: which includes AC1 DUTY
CONTRACTOR‐200A
4P, 200A MCCB 4P(Cat III) WITH SPREADER &
SHUNT, 3 PHASE SPD,
VOLTAGE MONITORING RELAY, ELR WITH CBCT,
INDICATING LAMP, POWER CABLE & OTHER
ACCESSORIES. All switchgears and connection are
enclosed with IP66 Enclosure and operate the
14.6. S.I.T.C of Distribution board from AC Side , ACDB 3- 1 Ea. 65500.00 1000.00
6 Phase - 101 kW - 200 kW: AC1 DUTY
CONTRACTOR‐300A
4P, 200A MCCB 4P (Cat III)WITH SPREADER &
SHUNT, 3 PHASE SPD,
VOLTAGE MONITORING RELAY, ELR WITH CBCT,
INDICATING LAMP, POWER CABLE & OTHER
ACCESSORIES. All switchgears and connection are
enclosed with IP66 Enclosure and operate the
14.7. S.I.T.C of Distributiob System DC Side, DCDB 1- 1 Ea. 4000.00 500.00
1 Phase - 1 kW - 3.5 kW(1in:1out) : DC MCB 500V,
SPD 600V, TYPE 2, TERMINAL/END,PLATE/END
(KUT6) FOR OUTPUT, DC CABLE With suitable size
of interconnection.
14.7. S.I.T.C of Distributiob System DC Side, DCDB - 3.6 1 Ea. 6500.00 500.00
2 kW - 6 kW (2in:2out) : DC MCB 500V, 16A, DC SPD
TYPE 2, TERMINAL/END PLATE/END CLAMP
4SQMM (KUT6), GREEN (KUT6), DC CABLE With
suitable size of interconnection.
14.7. S.I.T.C of Distributiob System DC Side, DCDB - 6 kW 1 Ea. 8500.00 500.00
3 - 10 kW (3in:3out) : DC MCB 500V, 16A, DC SPD
1000V, TYPE 2, TERMINAL/END PLATE/END
4SQMM (KUT6), GREEN (KUT6), DC CABLE With
suitable size of interconnection.
14.7. S.I.T.C of Distributiob System DC Side, DCDB - 10 1 Ea. 11500.00 700.00
4 kW - 20 kW (4in:4out) : Input Mcb - 1000 V, 16 Amp,
1000 V DC SPD TYPE
TERMINAL/END,PLATE/END CLAMP:
4SQMM (KUT6) FOR OUTPUT, DC CABLE With
suitable size of interconnection.
14.7. S.I.T.C of Distributiob System DC Side, DCDB - 20 1 Ea. 16500.00 700.00
5 kW - 25 kW (5in:5out) : Input Mcb - 1000 V, 16 Amp,
1000 V DC SPD TYPE
TERMINAL/END,PLATE/END CLAMP:
4SQMM (KUT6) FOR OUTPUT, DC CABLE With
suitable size of interconnection.
14.7. S.I.T.C of Distributiob System DC Side, DCDB - 35 1 Ea. 23500.00 700.00
6 kW - 40 kW (8in:8out) : Input Mcb - 1000 V, 16 Amp,
1000 V DC SPD TYPE
TERMINAL/END,PLATE/END CLAMP:
4SQMM (KUT6) FOR OUTPUT, DC CABLE With
suitable size of interconnection.
14.7. S.I.T.C of Distributiob System DC Side, DCDB - 50 1 Ea. 28500.00 700.00
7 kW - 65 kW (12in:12out) : Input Mcb - 1000 V,
1000 V DC SPD TYPE
TERMINAL/END,PLATE/END CLAMP:
4SQMM (KUT6) FOR OUTPUT, DC CABLE With
suitable size of interconnection.
14.7. S.I.T.C of Distributiob System DC Side, DCDB - 60 1 Ea. 30500.00 1000.00
8 kW - 80 kW (16in:16out) : Input Mcb - 1000 V,
1000 V DC SPD TYPE
TERMINAL/END,PLATE/END CLAMP:
4SQMM (KUT6) FOR OUTPUT, DC CABLE With
suitable size of interconnection.
14.7. S.I.T.C of Distributiob System DC Side, DCDB - 80 1 Ea. 37500.00 1000.00
9 kW - 300 kW (18in:18out) : Input Mcb - 1000 V,
1000 V DC SPD TYPE
TERMINAL/END,PLATE/END CLAMP:
4SQMM (KUT6) FOR OUTPUT, DC CABLE With
suitable size of interconnection.
PART - 8 Installation Accessories
14.8. Supplying & Errecting MC4 Connector Male - Female 1 Ea. 58.00 2.00
1 Set for Solar DC Cable which is installed in Solar PV-
module/Inverter/DCDB etc.
PART - 9 Water Sprinkler System
14.9. Providing & erecting Automatic solar panel cleaning
1 system for solar power projects which includes
necessary plumbing work (UPVC pipes and
accessories) from source of water to project site
(upto 30 meters),Suitable size of sub mercible/ open
well motor, necessary wiring for motor and sprinkler
system with safety, timer circuit for automatically
on/off the sprinkler system, necessary size oand
number of nozzles/JET (minimum 1 Nozzle/Jet per
(A) 1KW-5KW Cleaning System 1 PER 4000.00 500.00
(B) 5KW-10KW Cleaning System 1 PER 4000.00 500.00
(C ) 11KW-20KW Cleaning System 1 PER 3800.00 500.00
(D) 21KW-50KW Cleaning System 1 PER 3800.00 500.00
(E) 51KW-100KW Cleaning System 1 PER 3650.00 500.00
(F) 101KW-200KW Cleaning System 1 PER 3650.00 500.00
14.1 The all inclusive comprehencive annual maintance
0.1 contract cost covers yearly maintanance of solar Pv
Modules, Inverter, wiring,earthing,switchgears, etc
with material and labour cost including preventive
maintanance.The cost covers entire installation. AMC
also includes monthly site visit and inspection of
project with submission of inspection and solar
generation report. All parts should be
replaced/repaired if found faulty within specified time.
Agency has to provide necessory licening work for
warranty,power,Bidirectional meter etc
(A) 1KW-10KW System 1 PER 0.00 6500.00
(B) 11KW-20KW System 1 PER 0.00 6000.00
(C ) 21KW-50KW System 1 PER 0.00 5000.00
(D) 51KW-100KW System 1 PER 0.00 4500.00
(E) 101KW-200KW System 1 PER 0.00 4000.00
1. The bid is percentage rate bid.
2. The percentage rates shall be submitted in the formats given in the online Price
3. Rates and prices received in any other formats will be rejected and the Bids will be
4. The quoted rates should be inclusive of all taxes and duties.
I / We am / are willing to carry out the above/ below work at ………….% (in Figures)
……………………………………………………..………% (in Words) above / below of the
estimated rates mentioned above
AMOUNT OF MY / OUR TENDER WORKS OUT AS UNDER :-
ESTIMATED AMOUNT PUT TO TENDER : (ABOVE)
ESTIMATED AMOUNT PUT TO TENDER : (BELOW)
Signature and seal of contractor
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Solar Roof Top RC e - Tender-2026.pdf
Schedule - B.pdf
Download all tender documents and submit your bid