Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 CrAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹13.4 Cr+₹1.1 Cr (9.09%)Admitted-Finance PLOT NO 28 1ST FLOOR ASHWINI LAYOUT JUBILEE HILLS HYDERABAD TELANGANA 500033 | HYDERABAD | TELANGANA | 500033 | L2 | Admitted-Finance | |
| 3 | L3₹14.6 Cr+₹2.3 Cr (19.1%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹15.1 Cr+₹2.9 Cr (23.4%)Admitted-Finance BONDADA HOUSE C 26 KUSHAIGUDA INDUSTRIAL AREA KUSHAIGUDA ECIL HYDERABAD TELANGANA 500062 INDIA | HYDERABAD | HYDERABAD | TELANGANA | 500062 | L4 | Admitted-Finance | |
| 5 | L5₹16.7 Cr+₹4.5 Cr (36.4%)Admitted-Finance A 43 PHASE II EXTENSION GAUTAM BUDDHA NAGAR NOIDA NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201305 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201305 | L5 | Admitted-Finance |
Tender Value
₹11.1 Cr
EMD Value
₹10 L
Closing Date
5 Sept 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SDGM/ WCC, HSE, SAFETY
, BHEL-SBD, Prof CNR Rao Circle, IISc Post, Malleswaram, Bangalore- 560 012
Technical Operation and Maintenance works of 100 MW Solar Photovoltaic Grid-connected Power plant at GSECL, Raghanesda Solar Park Phase-I, Gujrat for a period of 120 months
2022_BHEL_16328_1
WCC-ASR-202223-016
Open Tender
Miscellaneous Works
Works
3650 days
Raghanesda, Gujrat
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹10 L
Yes
31 Oct 2022
8 Aug 2022
5 Sept 2022
8 Aug 2022
5 Sept 2022
8 Aug 2022
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Technical O&M | |||||
| 1.01 | Management of complete O & M activities by O&M in charge.
• One engineer ( B.E/B.Tech in Electrical Engg.) with minimum 33 kV working experience (Min. 3 years experience after Graduation ) to be appointed who will be the overall O&M in charge of the plant.
• One 33kV Licence Holder.: Shall Possess 33 kV Electrical Systems Operations & Maintenance Licence issued by Gujarat State Electrical Authority. This apart Min 3 years’ experience in Operation and Maintenance of 33 kV Electrical installations
Major responsibilities of O&M in charge :
(i) Allotment of work to all the O&M staff and supervision of O&M works as per schedule approved by BHEL.
(ii) Sending Daily, weekly and Monthly report to BHEL by mail.
(iii) Interaction with customer / SLDC/ RLDC etc.
(iv) Coordinating with sub-station upon grid failures /cable faults and implementing the needful steps to restore the plant to normal operation.
(v) Weekly / Monthly downloading of data from ABT meter using CMRI / as instructed by BHEL/GSECL. Liasoning and facilitating Joint Meter Reading (JMR) with GETCO and GSECL along with necessary laptop etc.
(vi) Maintaining plant records and log books, stock register and reporting to BHEL.
(vii) Trouble-shooting and Updating of SCADA system if required as instructed by BHEL.
(viii) Theft incidents: immediate reporting to BHEL/GSECL, filing FIRs at police stations on BHEL behalf, coordination for site inspection by insurance companies and clearance of insurance claims, logging of events (date, time) and maintaining records.
(ix) Accidents: immediate reporting to BHEL/GSECL, coordinating with hospitals, logging of events (data, time) and maintaining records.
(x) Monitoring of all O&M works so as to maintain generation from plant as per commitment to end client.
(xi) Logging of service call requirement at site on telephone with OEM within 2 hours of identification of service requirement.
(xii) Service log Book shall be maintained at site.
(xiii) Co-ordination with other agencies working for the plant O&M during execution of the work, inspection by statutory authorities etc. and whenever required for the smooth working of the plant totally. If there is any conflict arises, same has to be brought to the notice of the BHEL incharge and BHEL decision in this aspect is final and binding. | 120 | Months | 63,548 | ₹76,25,760 |
| 1.02 | Plant Operation works such as
(i) Logging of DC, AC, grid parameters (current, voltage, power, energy) at PCUs, HT panels, transformer temperatures, equipment tripping/ breakdown, grid outage as per BHEL formats.
(ii) SCADA data station / HMI PC operations/ CCTV operation for daily monitoring of weather parameters, trend graphs and urgent reporting to BHEL in case of any problems / anomalies observed with any of the parameters, resolving communication issues between SCADA and other equipment, healthiness of all equipment
Minimum 10 technicians (Diploma / ITI) with working Experience of Min 1 Year to be allocated for this activity. The O&M works mentioned are indicative. All the activities required for O&M shall be carried out by technicians as instructed by BHEL. Monthly reports to be prepared and submitted by mail to BHEL for the various parameters including Earth resistance, String currents at SCBs, Energy exported etc. as per report formats finalized by BHEL.
At least two technicians out of 10, shall be qualified for operating installations of 33KV and above. Certificate / license copy to be submitted to BHEL before commencement of O&M works.
One technician to be posted in Night shift operation of the plant. | 120 | Months | 1,58,403.25 | ₹1,90,08,390 |
| 1.03 | Carrying out Preventive and Breakdown maintenance as per O&M schedule / OEM guidelines / maintenance manual such as
a) Cleaning, tightness checks, lubrication and other maintenance of equipment -PCUs, HT panels, Inverter transformers, Auxiliary transformers, ACDB, FCBC, UPS, Battery banks, SCBs, SCADA, WMS, CCTV, Fire Alarm, ESE Lightning arresters, earthing, light fitting -indoor and outdoor etc.
b) Replacement of Silica gel, gaskets, Rectification of Oil leakages in all transformers.
c) Repair/ replacement of failed 33KV cable and OFC inside plant and upto GETCO substation, replacement of failed 33 kV termination and OFC / jointing kits.
d) Trouble-shooting of solar array problems as DC earth fault, OFC/ communication cable faults, replacement of damaged PV modules, SCB components etc.
e) Checking tightness of MMS and PV Modules
(f) Monthly earth resistance measurement and recording value on the Earth chambers
(g) Watering of earth pits.
(i) Minimum 3 technicians (Diploma/ITI) with working Experience of Min 1 Year and minimum 6 labours to be allocated for this activity.
(ii) List of equipment mentioned is indicative. Maintenance of all the equipments installed in plant is in vendor's scope.
(iii) Periodic maintenance shall be preferably carried out during evening to avoid generation loss.
(iv) Whenever a fault has occurred, the contractor has to attend to rectify the fault & the fault must be rectified within 48 hours from the time of occurrence of fault.
(v) Major spares such as complete equipment failures of CT, PT, LA, Breaker, Isolator, SCB, PCU, transformer, cables, HT termination and jointing kits etc. if any will be supplied by BHEL.
(vi) Minor spares and consumables such as MCBs, all type of Fuses (for SMB, PCU and for all other equipments), Lights in PV area, switch yard & buildings , fans, indication lamps, gaskets, silica gel, transformer oil for top-up. Acid for battery, Fastners, termination kits, cable lugs, glands and heat shrinkable sleeves of all required sizes, MC4 connectors, PCU dust filter, sanitary fittings. if required shall be supplied by vendor.
vii) In case of Maintenance activity / failure / damage / accident / replacement / repair required for any of the plant equipment such as Solar modules, HT panels, all transformers etc. or for any other site related activities, unloading, erection, installation, charging, co-ordination with agencies involved, etc., shall be in O&M vendor’s scope. Arrangement of Crane / hydra / JCB/ additional labour hiring / Ladder, etc., for arranging replacement of failed equipment shall also be in the scope of O&M vendor.
(viii) All tools and tackles required for maintenance activities shall be arranged by O&M vendor. | 120 | Months | 1,65,729.23 | ₹1,98,87,507.6 |
| 1.04 | Annual maintenance of all transformers with respect to BDV measurement, Oil filtering as required or annually, tightness of cables, earthing and hardwares, tightening of MMS FAsteners replacement of gasket, silica gel breather, paint touch-up, arresting oil leakages and oil top-up of all transformers and other related electrical works.
Through OEM / competent testing agencies as approved by BHEL. All required tools, tackles, testing and measuring instruments, Oil filtration kit, DG set and transformer oil for top-up etc..All Consumables and Oil etc to be arranged by vendor. | 10 | AU | 6,73,295.45 | ₹67,32,954.5 |
| 1.05 | Annual testing and calibration of 33 kV HT panel equipment as VCBs, CTs, PTs, Numerical relays, electromechanical relays, MFMs etc. Periodic checking and Maintenance of Metering Panel CTs and PTs and Tightening of Terminations,
Through OEM / competent testing agencies as approved by BHEL. All required tools, tackles, testing and measuring instruments, DG set etc. to be arranged by vendor. | 10 | AU | 4,25,956.58 | ₹42,59,565.8 |
| 1.06 | Calibration of Weather Monitoring Station equipment
Weather monitoring station equipment to be calibrated at IMD or OEM recommended labs as per calibration period of individual equipment as recommended by OEM. | 10 | AU | 58,146.1 | ₹5,81,461 |
| 1.07 | Checking and re-filling of Fire extinguishers and sand buckets as required.
All the fire extinguishers to be checked for healthiness and re-filling to be carried out as and when required. | 10 | AU | 27,587.03 | ₹2,75,870.3 |
| 1.08 | Maintenance and Servicing of Air conditioners, Refrigerator, Furniture, Water purifier, fans etc.
Breakdown maintenance and servicing of equipment as and when required to be carried out by vendor. Periodic maintenance on annual basis. | 120 | Months | 11,996.5 | ₹14,39,580 |
| 1.09 | Painting of metal structures (non-galvanized as well as galvanized), rolling shutters, switchyard and transformer yards fencing and gates, all rusted components etc.
All civil structures shall be applied with Bitumen paint on annual basis to prevent corrosion / erosion of Concrete.
De-rusting and Painting of all metal structures and bitumen coating of all civil structures shall be carried out once in every year. Galvanized structures shall be touched up with Zinc rich Metallic paint wherevre found rusted after due cleaning and for this 20 litres of paint shall be supplied every year to the plant. For non galvanized structures Enamel paint as required for touch up shall be supplied. | 10 | Years | 1,03,849.57 | ₹10,38,495.7 |
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
PART-A-NIT.pdf
Tender Notice • 6.86 MB
BOQ_17276.xls
BOQ Document • 0.30 MB
103299714.pdf
Tender Document • 0.92 MB
103299716.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .