| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAdmitted-Finance | ₹1.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.9 Cr+₹10.1 L (5.73%)Admitted-Finance | ₹1.9 Cr+₹10.1 L (5.73%) | L2 | Admitted-Finance |
| 3 | L3₹2.0 Cr+₹22.9 L (13.0%)Admitted-Finance | ₹2.0 Cr+₹22.9 L (13.0%) | L3 | Admitted-Finance |
| 4 | L4₹2.0 Cr+₹25.0 L (14.2%)Admitted-Finance 1ST FLOOR KRISHNA TOWERS OPP TO THRIKKAKARA TEMPLE THRIKKAKARA P O COCHIN 682 021 | ERNAKULAM | KERALA | 682021 | ₹2.0 Cr+₹25.0 L (14.2%) | L4 | Admitted-Finance |
| 5 | L5₹2.0 Cr+₹25.5 L (14.4%)Admitted-Finance | ₹2.0 Cr+₹25.5 L (14.4%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SHRADDHA ENGINEERING AND FACILITY SERVICES L1 | CHENNAI ENGINEERING SERVICES L2 | PAN POLAR ENGINEERS PVT. LTD. L3 | sterling and wilson private limited L4 | S. N ELECTRICALS L5 | ABHISHEK ASSOCIATES L6 | JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED L7 | DElite System Engineering (India) Pvt. Ltd. L8 | JAI ENTERPRISES L9 | VOLTAS LIMITED L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Operation and Maintenance of E & M Installations of New power house & Old power house, Internal & External electrification around the new power house and old power house, water supply system by carrying out preventive maintenance, attending to the complaints by providing qualified manpower, tools, cleaning materials etc., round the clock including sundays and holidays in three shifts as per enclosed Special conditions of contract and particular specifications and as per the instructions of the Engineer-in-Charge or his authorized representative from time to time complete as required. | 24 | Months | - | - | - | - | - | - | - | - | - | - |
| 2.00 | Testing of transformer oil sample with HT B.D.V kit including conducting acidity test and producing test certificate etc., as required. | 24 | Job | - | - | - | - | - | - | - | - | - | - |
| 3.00 | Filtration / Dehydration of transformer oil till attaining the required BDV i/c to and fro transportation of filtration machine to site, submission of test reports etc., as and when required. | 9,120 | Ltr | - | - | - | - | - | - | - | - | - | - |
| 4.00 | Supply of Silica gel crystals for transformer breathers etc as and when required. | 40 | Kg | - | - | - | - | - | - | - | - | - | - |
| 5.00 | Supply of transformer oil with test report for topping up the transformer i/c transportation as on when required. | 600 | Ltr | - | - | - | - | - | - | - | - | - | - |
| 6.00 | Testing, Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(a) Over current relay cum earth fault relay. | 10 | set | - | - | - | - | - | - | - | - | - | - |
| 7.00 | Testing, Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(b) 33 KV HT VCB panel master trip relay testing & calibration. | 10 | each | - | - | - | - | - | - | - | - | - | - |
| 8.00 | Testing, Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(c) 33 KV HT VCB panel master trip relay testing & calibration. | 10 | each | - | - | - | - | - | - | - | - | - | - |
| 9.00 | Testing, Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(d) 33 KV HT VCB panel timer relay testing & calibration for Incomer Panel | 2 | each | - | - | - | - | - | - | - | - | - | - |
| 10.00 | Testing, Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required.
(e) 33 KV HT VCB panel under voltage relay testing & calibration for Incomer Panel. | 2 | each | - | - | - | - | - | - | - | - | - | - |
Tender Value
₹2.1 Cr
EMD Value
₹4.2 L
Closing Date
11 Feb 2020, 6:00 pmClosed
Asst.G.M,ENGINEERING,ELECTRICAL,AAI,VIZAG
Asst.G.M, ENGINEERING, ELECTRICAL, AAI, VISAKHAPATNAM
OPERATION AND MAINTENANCE OF ELECTRICAL AND MECHANICAL INSTALLATIONS IN TERMINAL BUILDING,OPERATIONAL AREA AND 33KV SUBSTATION
2020_AAI_40715_1
AAI/VZ/ENGG(E)/RM/ENIT13
Open Tender
Electrical Works
Item Rate
730 days
VISAKHAPATNAM AIRPORT
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,180
Yes
AIRPORTS AUTHORITY OF INDIA
₹4.2 L
Yes
25 Feb 2020
28 Jan 2020
18 Feb 2020
29 Jan 2020
11 Feb 2020
29 Jan 2020
29 Jan 2020 - 11 Feb 2020
Amount
Operation and Maintenance of E & M Installations of New power house & Old power house, Internal & External electrification around the new power house and old power house, water supply system by carrying out preventive maintenance, attending to the complaints by providing qualified manpower, tools, cleaning materials etc., round the clock including sundays and holidays in three shifts as per enclosed Special conditions of contract and particular specifications and as per the instructions of the Engineer-in-Charge or his authorized representative from time to time complete as required.
Testing of transformer oil sample with HT B.D.V kit including conducting acidity test and producing test certificate etc., as required.
Filtration / Dehydration of transformer oil till attaining the required BDV i/c to and fro transportation of filtration machine to site, submission of test reports etc., as and when required.
Supply of Silica gel crystals for transformer breathers etc as and when required.
Supply of transformer oil with test report for topping up the transformer i/c transportation as on when required.
Testing, Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required. (a) Over current relay cum earth fault relay.
Testing, Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required. (b) 33 KV HT VCB panel master trip relay testing & calibration.
Testing, Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required. (c) 33 KV HT VCB panel master trip relay testing & calibration.
Testing, Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required. (d) 33 KV HT VCB panel timer relay testing & calibration for Incomer Panel
Testing, Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required. (e) 33 KV HT VCB panel under voltage relay testing & calibration for Incomer Panel.
Testing, Servicing and calibration of the following relays including and checking and rectifying the tripping circuit for HT 33KV VCB incoming / outgoing panels etc., complete as required. (f) 33 KV HT VCB panel Auxiliary relay for Trip & Alarm testing & calibration for Transformers (2 relays per Transformer VCB)
Half-yearly maintenance and Servicing of 33KV, 1250A VCB including complete servicing and cleaning of breaker mechanism parts, checking all electrical and mechanical components, checking and servicing of draw-out mechanism including relay testing etc, complete as required and six months service warranty, breakdown calls should be attend within 24 hours. (Maintenance shall be carried out through OEM / authorized dealer). (a) 33KV / 1250A Incomer - 1 No. (b) 33KV / 1250A Out-going - 3 Nos.
Half-yearly Maintenance and Servicing of 415V, 4 Pole ACB of following rating including complete servicing and cleaning of breaker mechanism parts, checking all electrical and mechanical components ,checking and servicing of draw-out mechanism including removal of worn-out electrical and mechanical parts, replacement works,relay testing etc, complete as required and six months service warranty and break down calls should be attended within 24 hours. (Maintenance shall be carried out through OEM / authorized dealer). spares will be provided by AAI. (a) 2500A / 4Pole ACB for Transformers out going & Bus Couplers-5 Nos
Half-yearly Maintenance and Servicing of 415V, 4 Pole ACB of following rating including complete servicing and cleaning of breaker mechanism parts, checking all electrical and mechanical components ,checking and servicing of draw-out mechanism including removal of worn-out electrical and mechanical parts, replacement works,relay testing etc, complete as required and six months service warranty and break down calls should be attended within 24 hours. (Maintenance shall be carried out through OEM / authorized dealer). spares will be provided by AAI. (b) 1250A / 4Pole ACB Out-going - 17 Nos.
Half-yearly Maintenance and Servicing of 415V, 4 Pole ACB of following rating including complete servicing and cleaning of breaker mechanism parts, checking all electrical and mechanical components ,checking and servicing of draw-out mechanism including removal of worn-out electrical and mechanical parts, replacement works,relay testing etc, complete as required and six months service warranty and break down calls should be attended within 24 hours. (Maintenance shall be carried out through OEM / authorized dealer). spares will be provided by AAI. (C) 1000A / 4Pole ACB Out-going - 02 Nos
Half-yearly Maintenance and Servicing of 415V, 4 Pole ACB of following rating including complete servicing and cleaning of breaker mechanism parts, checking all electrical and mechanical components ,checking and servicing of draw-out mechanism including removal of worn-out electrical and mechanical parts, replacement works,relay testing etc, complete as required and six months service warranty and break down calls should be attended within 24 hours. (Maintenance shall be carried out through OEM / authorized dealer). spares will be provided by AAI. (d) 800A / 4Pole ACB Out-going - 7 Nos.
Testing, Servicing and calibration of following safety relays for 33 KV / 433 V Transformers including submitting of test reports etc. complete as requied. (a) Buchholz's relay
Testing, Servicing and calibration of following safety relays for 33 KV / 433 V Transformers including submitting of test reports etc. complete as requied. (b) OTI relay
Testing, Servicing and calibration of following safety relays for 33 KV / 433 V Transformers including submitting of test reports etc. complete as requied. (c) WTI relay
Transportation of HSD oil from Petrol bunk to Airport power house. Approx. quantity of oil to be transported upto 1000 ltrs. Approx. distance from petrol bunk is 4 Km. Excluding loading and unloading.
Painting of LT panels / feeder pillars with one coat metal primer on rusted surface and two coats approved synthetic enamel paint , lettering etc., as required upto the satisfaction of the Engineer-in-charge as and when required.
Painting of street light poles with one coat of metal primer on rusted surface and two coats of approved aluminum paint i/c dismantling, re-fixing of fittings and scraping the surface as required to the satisfaction of the Engineer-in-charge as and when required. pole height 11mtrs approximately.
Supply of 3-phase Panel Digital Voltmeter of range 0 to 500V AC,AUX supply 240 VAC suitable for operation on three phase , 440 V , 50 HZ AC supply [Schneider Model No Conzerv DM 3210 or equivalent)
Supply of 3-phase Panel Digital Ammeter of range 0 -100-1600A AC,AUX supply 240 VAC suitable for operation on three phase , 440 V , 50 HZ AC supply (Schneider Model No Conzerv DM 3110 or equivalent).
Supply of 3-phase Intelligent panel digital Multi Function meter suitable for operation on three phase , 440 V , 50 HZ AC supply ( Make : L & T or equivalent )
Supply of 1-phase LED Indication lamps suitable for operation on Single phase, 240 V, 50 Hz, AC supply (Make : ESBEE, Model: E-Series or equivalent) (a) Red
Supply of 1-phase LED Indication lamps suitable for operation on Single phase, 240 V, 50 Hz, AC supply (Make : ESBEE, Model: E-Series or equivalent) (b)Yellow
Supply of 1-phase LED Indication lamps suitable for operation on Single phase, 240 V, 50 Hz, AC supply( Make : ESBEE, Model: E-Series or equivalent) (c) Blue
Supply of 1-phase LED Indication lamps suitable for operation on Single phase, 240 V, 50 Hz, AC supply( Make : ESBEE, Model: E-Series or equivalent) (d) Green
Pollution test /Stack monitoring and Noise level monitoring of 750KVA DG-Sets with suitable kit including Conducting SPM(Suspended particles matter), SO2 (Sulphur dioxide), NOx (Oxides of Nitrogen) tests and submision of test reports etc. as and when required.
Operation and Maintenance of Internal and External Electrical & Mechancial installations in Integrated Terminal Building, Cargo Building, Technical Block, Car parking, Garden areas, Internal Roads, CISF barracks (Viman Nagar), NAVAIDS (TDVOR, Glide Path and Localiser), Administrative offices, Engg. offices, taxi way edge lighting system including CCR at Old apron and new apron by carrying out Preventive maintenance Checks, attending complaints, maintaining all records by deploying qualified manpower, tools, cleaning materials etc., in three shifts per day including Sundays and Holidays as per the enclosed special conditions of contract, Particular specifications and as per the instructions of the Engineer-in-Charge or his authorized representative from time to time complete as required.
Operation and Maintenance of Internal and External Electrical & Mechancial installations in forth coming Linear Expansion of Integrated Terminal Building taxi way edge lighting system including CCR at Old apron and new apron by carrying out Preventive maintenance Checks, attending complaints, maintaining all records by deploying qualified manpower, tools, cleaning materials etc., in general shift per day including Sundays and Holidays as per the enclosed special conditions of contract, Particular specifications and as per the instructions of the Engineer-in-Charge or his authorized representative from time to time complete as required.
Supply, cutting, pasting and fixing of sign board sticker as and when required.
Rewinding & servicing of ceiling fan motors with complete overhauling and replacement of worn out bearings and transportation to the AAI site, etc as required.
Supply of 5 star rated, energy saving ceiling fan suitable to operate on 240V, 50Hz AC supply complete as required.
Re-winding of following rating sub-mersible pump motors including dismantling, cutting of burnt out wire, re-assembling, testing of motor, transportation of the submersible pump motor set to the site etc as and when required. (a) 3.0 HP
Re-winding of following rating sub-mersible pump motors including dismantling, cutting of burnt out wire, re-assembling, testing of motor, transportation of the submersible pump motor set to the site etc as and when required. (b) 5.0 HP
Repairing / servicing of following rating sub-mersible pumps i/c replacement of all worn out GM bushes, thrust bearings, impellers, studs sets and necessary spares and lathe work, transportation charges complete in all respect etc., as on when required. (a) 3.0 HP
Repairing / servicing of following rating sub-mersible pumps i/c replacement of all worn out GM bushes, thrust bearings, impellers, studs sets and necessary spares and lathe work, transportation charges complete in all respect etc., as on when required. (b) 5.0HP
Lifting of following submersible pumps upto 200 feet from the existing bore well / open well along with GI / MS pipe lines, cable and reinstallation of the same after repair / rectification of the defects as and when required. (Charges for repair / rectification of the pump or motor is not included). 5.0 HP/7.5 HP
Re-winding of following rating 3.0 Phase induction motors including dismantling, cutting of burnt out wire, re-assembling, testing of motor, transportation of the Induction motor set to the site etc as and when required.
Supply of TCCA-90 Chlorine for day to day maintenance of Garden fountain.
Supply of filter media sand for day to day maintenance of fountain.
Supply of fountain design underwater lights made of ABS body with 90 LED with provision of Geyser foam type jet nozzle with bush, complete as required.
Supply of Cascaded submersible nozzle and Geaser jet fountain nozzle., complete as required.
Supply of Cascaded submersible nozzle foam type jet fountain nozzle., complete as required.
Supply of 1'' brass Ball Valve (including 1'' nipple and union) for controling the pressure of fountain nozzles., as per site requirement, complete as required.
Supply of maintenance kit with 9 mtr Hose pipe, algae brush, Vaccum head, telescopic rod and leaf net complete as required.
DSR 2018 item for Rs. 5,00,000/- per year. [Note : The rate may be quoted in the following manner - (i) If quoted rate is Rs. 4,46,450/- (Against Rs. 5,00,000/-) then the percentage will considered as 0% above / below DSR 2018. (ii) If quoted rate is Rs. 4,01,805/- (Against Rs. 5,00,000/-) then the percentage will considered as 10% below DSR 2018. (iii) If quoted rate is Rs. 4,91,095/- (Against Rs. 5,00,000/-) then the percentage will considered as 10% above DSR 2018. (a) 1st Year
DSR 2018 item for Rs. 5,00,000/- per year. [Note : The rate may be quoted in the following manner - (i) If quoted rate is Rs. 4,46,450/- (Against Rs. 5,00,000/-) then the percentage will considered as 0% above / below DSR 2018. (ii) If quoted rate is Rs. 4,01,805/- (Against Rs. 5,00,000/-) then the percentage will considered as 10% below DSR 2018. (iii) If quoted rate is Rs. 4,91,095/- (Against Rs. 5,00,000/-) then the percentage will considered as 10% above DSR 2018. (b) 2nd Year
CHENNAI ENGINEERING SERVICES
PAN POLAR ENGINEERS PVT. LTD.
sterling and wilson private limited
S. N ELECTRICALS
ABHISHEK ASSOCIATES
JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED
DElite System Engineering (India) Pvt. Ltd.
JAI ENTERPRISES
VOLTAS LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 6.92 MB
TENDOCOANDM2020-22.pdf
Tender Documents • 6.91 MB
BOQ_44456.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .