GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT - 133001
MANNING AND OPERATION OF CENTRAL PACKAGE AC PLANT UNDER GE UTILITY AMBALA CANTT
2021_MES_453240_1
GE(U)/AMB-23/2021-22
Open Tender
Civil Works
Item Rate
330 days
AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹83,900
Yes
11 Aug 2021
23 Jun 2021
22 Jul 2021
23 Jun 2021
20 Jul 2021
7 Jul 2021
23 Jun 2021 - 6 Jul 2021
Amount
SECTION- I (M&O) Manning & operation and comprehensive maintenance of AC Plants (04 Nos) round the clock to maintain desire temperature and humidity including ensuring proper maintaining the desired condition viz W.B.T. RH etc.inside AC room including, maintaining hourly record thereof for round the clock in log sheets including proper upkeep of AC Plant room and surrounding area by adopting all the prevailing labour act IE Rules and MES standing orders by technically quallified/Experienced tradesmen (01 Skilled AC Plant operator/Refg Mechanic) for each shift of 08 hours, for 03 shifts for each plant including sunday and holidays etc for the following AC Plants :-
MH OT AC PLANT CONSISTING OF FOLLOWING :-
(a) Compressor make Voltas model WCDS-036DMN Cap 36 TRX3unit with condenser & chiller
(b)Mono block pump set 5HP for chiller-02 Nos Make -Crompton Greaves.
(c)Centrifugal pump set cap 7.5 HP for condenser 02 Nos Make-Crompton Greaves.
(d) Water softening plant for cooling tower and chiller -01 No Make -INIDON.
(e)Cooling tower with CT fan & motor -01 No
(f)LT control panel with MCCBs and starter complete-01 No.
(g)Pipe line with control valve and other controls such as LT and HT cutout thermostat humidity stat expansion valve etc-01 Lot.
(h)Ducting for supply of air with grills and return air grill.
(j)AHU unit - 2 Nos comprising of blower motor 15 HP each , thermostate, strip heater,HEPA/ Micro/ pre filters, cooling coils , Dampers and fire dampers etc complete .
MH MATERNITY WARD AND COLD STORAGE AC PLANT CONSISTING OF FOLLOWING:-
(a) Compressor of model SZ-185S4C of cap 12 TR X3 Units with condensor and Chillers
(b) Electric motor 3 phase 03 HP -06 Nos Make- Kirloskar for condensor and chiller.
(c) AHU unit comprising of cooling coils strip heaters blower motor 5HP-01 No , dampers , fire dampers and thermostat etc complete .
(d) Cooling tower with CT fan & motor 5 HP -01 No.
(e) Pipe line with control valve and other controls such as LT and HT cutout thermostat humidity stat expansion valve etc-01 Lot.
(f) Ducting for supply air with grills and return air grill.
(g) LT control panel with MCCBs and starter complete-01 Nos.
(h) Servo voltage stabilizer 50 KVA capacity -01 No.
MH MATERNITY WARD AC PLANT CONSISTING OF FOLLOWING:-
(a) Compressor Model 1202 of capacity 2x5 TR= 03 Nos-Make Blue Star.
(b) Electric motor 3 phase 2HP-03 Nos Make Hindustan.
(c) Mono block pumping sets 2x5 HP-02 Nos.
(d) Electric control panel comprising of MCCBs, starters ,single phase preventer,relays, power contactors interlocking system including cable .-01 Lot.
(e) Cooling tower with CT fan & motor -01 Nos.
(f) Pipe line with control valve and other controls such as LT and HT cutout thermostat humidity stat expansion valve etc-01 No
(g) Ducting for supply air with grills and return air grill. Includingstrip heaters, thermostat, wiring etc complete.
(h) Servo voltage stabilizer 50 KVA capacity -01 Nos.
AC PLANT SIGNAL CENTRE CONSISTING OF FOLLOWING:-
(a) Compressor Model 1202 of capacity 3x7.5 TR= 03 Nos-Make Blue Star.
(b) Electric motor 3 phase 2HP-03 Nos Make Hindustan.
(c) Mono block pumping sets 2x5 HP-02 Nos.
(d) Electric control panel comprising of starters single phase prenventer interlocking system including cable .-01 Lot.
(e) Cooling tower with CT fan & motor -01 Nos.
(f) Pipe line with control valve and other control such as LT and HT cutout thermostat humidity stat expansion valve etc-01 Lot.
(g) Ducting for supply air with grills and return air grill.
(h) Servo voltage stabilizer 50 KVA capacity -01 Nos.
Description all as per Item No 1.00 here in before but 01 Skilled (AC Plant operator/ Refg Mechanic) for each shift of 08 Hours for 2 Shifts daily including Sunday and Holidays etc. for Raina Auditorium consisting of following:-
(a) Electric control panel comprising of MCCBs, starters, single phase preventer, contactors, interlocking system including cable -01 Lot.
(b) Air cooled scroll type chilling machine operated on R-407, of capaicty 70 TR = 2 Sets of 03 compressors each.
(c) AHU unit- 02 Nos comprising of cooling coils 6 row deep. strip heaters , dampers , fire dampers & blowers motor 5HP-02
(d) Mono block pumping sets 7.5 HP-03 Nos.
(e) Fan coil unit 20 SWG with 03 row deep chilled water coil pre filter DIDW centrifugal fans ,of capacity 3 TR - 4 Nos.
(f) Rectangular duct for air with adjustable vains, dampers, grills with insulation with 16 mm thick nitrile rubber and thermocouple 22 gauge.
(g) Pipe line MS of class C , duly insulated with puf insulation sand , cement plaster including valves.
(h) PVC overhead tank of capacity 1000 ltr, GI pipe and PVC loose pipe 20/25 mm dia.
Note for contractor for Item No. 1.00 & 2.00 above: (a) Providing summer and winter uniform along with proper shoes to the operators.(b) Providing T&P and display board of the firm along with minimum fare wages written on it. (C) Maintaining log sheets, duty roster, attendance register along with photo of the individual operator must be displayed at pump house or at the installation. (d) Rates of all above notes deemed to be included by the contractor in quoted rates. (e) If all above documents are not found during inspection of AGE or GE, the penalty of Rs.100/-per day will be imposed from the first date of the each month.
The rates qouted by the contractor shall be inclusive all taxes like GST, EPF, ESI, LWC as applicable and also include contractor's profit etc. In this connection please refer Note No. 20 of Sch A/BoQ Notes mentioned in tender documents.
The cost of the following included in rate quoted by contractor and nothing extra shall be admissible:-
(i) Air filter of all the plants to be cleaned every week.
(ii) Penal recovery at the rate of Rs 500 per hour per plant shall be levied from the contractor in case of not attending the AC plants including non availablity of resources for concern AC plant.
(iii) Confirmation on completion of any nature of complaints regarding non functioning of AC plants will be intimated to JE concernd forthwith of the area or Engr-in-Charge immediately.
(iv) Arrangement for the resources detailed for maintaing the desired condItioning of the AC plant room shall be made by the contractor in such a way that every time resources shall be made available at AC plant to make the plant fully functional in case of non complaince, panality as mentioned in Para (ii) above will be imposed.
(v) The scope of work under the above contract will broadly include following :-
(vi) Maint and fault rectification of incoming & out going LT electrical system including LT panel of AC plant including tightening loose connection providing minor spare parts i.e. nuts, bolts, washers, thimbles , PVC tape, saddles, rawal plug, fasteners and any other spare etc.
(vii) Proper maintenance of all the inlets and outlet valves, coils, Gauges, Cut outs & relays all the connected items of AC plants.
(viii) Coordination will be made with the concern electric and water supply JE's to ensure proper electric & water supply to the plant.
(ix) Any complaint regarding AC plants, water supply & electric supply are mandatory to be rectified for smooth running of the AC plants as directed by Eng-in-Charge.
(x) Earth test shall be carried out periodically and earth result will be maintained within permissible limit by pouring water in earth pits.
(xi) Checking of water leakage of mono block pumbing set at each plant and replacement of gland /seal, greasing to pumping sets and motors shall be carried out.
(xii) Cold storage AC plant is part of Maternity Ward AC Plant and no separate payment shall be admisible for operation of cold storage AC Plant.
(xiii) Earth plate will be operated by separate operater
(xiv) The contractor shall provide one AC mechanic daily from 0900 hrs to 1700 hrs so that no complaint shall be remain un attended Rates quoted by the contractor shall deemed to be included for this privision.
(xv) The operator of AC plant at Sig centre and Raina auditorium will also operate the DG set of MES installed near AC plant whenever it is required by the user Rates for this effect shall deemed to be included in quoted rates. Disal will be collected from Alpha power house and pouring into the DG set shall be the contractor respossibility.
(xvi) Attendance register, Log sheet, duty register all documents has to provided and maintant by the contractor. Non maintaing of documents the panelty of Rs 200/day/document will be impesed of the contractor, if the documents checked an aney day of the month the panelty will be imposed from first day of month.
(xvii) Contractor has to provided the summer and winter uniform to the operater failing which Rs 1000 /- per month/operater will be imposed.
(xviii) The Contractor shall install the display board at each installations , the display board having the info as follows :- (a) Firm Name (b) Contractor Name (c) Contractor working Mob No (d) Minimum fare wages
(xix) Non installation of the display boards panelty of Rs 2000/- per month/Installation will be imposed.
SECTION II (MAINTENANCE WORKS) Supply and topping up of Refrigerant R-22. as directed by Engineer-in-Charge. Note : Labour charges for charging of gas to plants shall be included in the rate quoted.
Supply and topping up of Refrigerant R-407 as directed by Engineer-in-Charge. Note : Labour charges for charging of gas to plants shall be Included in the rate quoted.
Raman Electric Trading Co
kapil enterprises
M/S Trilok chand sharma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .