Loading…
Loading…
Tender Value
₹3.6 L
EMD Value
₹3,600
Closing Date
19 Aug 2026, 12:00 pmClosed
DEPUTY EXECUTIVE ENGINEER, NADIAD ELECTRICAL SUB DIVISION, NADIAD
All in Comprehensive maintenance of D.G.Set installed at various non residential building in Nadiad section under Nadiad Electrical Sub division,Nadiad. (Nadiad Section)
331503
15/08 OF 2026/2027
Open
Electrical and Maintenance Works
Works
Nadiad
11 documents required · 11 mandatory
₹600
Executive Engineer, Ahmedabad Electrical Dn No 2 Ahmedabad
₹3,600
5 Aug 2026
5 Aug 2026
5 Aug 2026
19 Aug 2026
5 Aug 2026
Name of work :- All in Comprehensive maintenance of D.G.Set installed at various non residential
building in Nadiad section under Nadiad Electrical Sub division,Nadiad. (Nadiad
Fund Head:- 2059 M & R SR
Item Quantity Particulars Issue Rate Amount
Signature of Contractor
Name of Work :- All in Comprehensive maintenance of D.G.Set installed at various non residential building in Nadiad section under
Nadiad Electrical Sub division,Nadiad. (Nadiad Section)
Item Qty. Unit Item of work Net Rate in Net Rate in words. Per Amount
1A 4.00 Jobs All in Comprehensive maintenance of Various 38418.28 Rupees ThirtyEight Job
Rating D.G. set for continuous trouble free Thousand Four Hundred
operation for one year. 1. Replacing the fuel filters Eighteen Paise
& Oil filters.2. Checking the alignment and tappet TwentyEight Only
setting.3. Checking the carbon brushes / AVE.
Checking the oil level and replace the oil.5.
Leakages IN/OUT Cylinder. 6. All Electrical wrings
including AMF panel if available.7. Dynamo
Setting. 8. RPM setting, Frequency & Voltage
Adjustment.9. Replacing material like fuel filters,
gasket, tappet covers, diode rectifiers, Bridge
rectifiers if found defective and in not working
condition.10. Kindly note that labour with spares is
included in the above. 11. Major Overhauling &
Top overhauling shall be included in scope of
Agency. 12. including Replacement of Battery if it
is not working.((1) The All inclusive
comprehensive maintenance cost covers the
yearly maintenance cost of the electrical
machineries with material & Labour cost including
preventive maintenance. The cost covers entire
installation from outlet of main switch to electrical
machine.)(H) Continuous Rating of 62.5 KVA .
1B 2.00 Jobs (L) Continuous Rating of 125 KVA 57228.37 Rupees FiftySeven Job
Thousand Two Hundred
TwentyEight Paise
ThirtySeven Only
1C 1.00 Jobs (P) Continuous Rating of 200 KVA 90159.06 Rupees Ninety Thousand Job
One Hundred FiftyNine
Amount Put to tender Rs.
Item Qty. Unit Item of work Net Rate in Net Rate in words. Per Amount
I/ We am/are willing to carry out the work at_________% above / below percent (should be written in figure & words) of the estimated mentioned above. Amount of my / our tender works out
Estimated amount put to Estimated amount put to
(a) I/we hereby declare that we have visited the site and fully exquisite myself/ourselves with the Local situation regarding materials labour and other factors pertaining to work before
submitting Tender.
(b) I/we hereby declare that we have carefully studies the conditions of contracts. Detailed Specification and other tender document of this work and agree to execute the same
1 The Rates are inclusive of all taxes, transport charges, storage charges and other taxes excluding GST as applicable from time to time.
2 All works shall be carried out as per public works Department hand book and other Specification.
3 Rates are inclusive of 1% Labour cess in tender amount so 1% of total amount of bill will be deducted from the bill.
3 Rates are inclusive of 1% Labour cess in tender amount so 1% of total amount of bill will be deducted from the bill.
4 The material to be used in this work must be as per instruction by under liason of Engg. In charge.The agency will have to agree to carried out the work as per brand/make demand
of concern deptt.
5 Contractor must have registration in "E2" & above class registered under elect. (R & B) division .
6 If required and found necessary material to be used for this work & brought at site will hae to sent to Govt. approved laboratory. Necessary testing cost to be beared by
agency/manufacturer of the particular product.
Deputy Executive Engineer
Nadiad R & B Electrical Sub Division
Signature of contractor Nadiad
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Concent Letter.pdf
CONDITIONS -AMC DG.pdf
G S T LTR.pdf
GR.pdf
online jaher nivida-15 of 2026-27.pdf
PQ DG Nadiad section.pdf
SCHEDULE A ADN B DG Nadiad section.pdf
STANDARD BIDDING DOCUMENTS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .