Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 CrAccepted-AOC EBENEZER C C33 1185A CHALIKAVATTOM VENNALA P O KOCHI KERALA 682 028 | ERNAKULAM | KERALA | 682028 | ₹8.2 Cr Quoted ₹8.3 Cr | L1 | Accepted-AOC Accepted being lowest and quoted amount found reasonable. |
| 2 | L2₹8.4 Cr+₹11.4 L (1.38%)Rejected-Finance 602 6TH FLOOR BNG HOUSE D N ROAD FORT MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹8.4 Cr+₹11.4 L (1.38%) | L2 | Rejected-Finance Rejected being not lowest. |
| 3 | L3₹8.5 Cr+₹20.6 L (2.48%)Rejected-Finance | ₹8.5 Cr+₹20.6 L (2.48%) | L3 | Rejected-Finance Rejected being not lowest. |
| 4 | L4₹8.5 Cr+₹20.9 L (2.52%)Rejected-Finance BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | ₹8.5 Cr+₹20.9 L (2.52%) | L4 | Rejected-Finance Rejected being not lowest. |
Tender Value
₹8.7 Cr
EMD Value
₹7.6 L
Closing Date
29 Jun 2023, 6:00 pmClosed
CE NW Kochi
MILITARY ENGINEER SERVICE NAVAL BASE POST KATARIBAGH COCHIN 682004
SPECIAL REPAIRS INCLUDING STRUCTURAL REHABILITATION OF BLDG NO P 65 MAKAR AT SMA RAMESWARAM KOCHI
2023_MES_596116_1
891047
Open Tender
Civil Works
Item Rate
540 days
KOCHI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹3,000
Yes
GE FORT KOCHI
₹7.6 L
Yes
17 Jul 2023
17 May 2023
1 Jul 2023
18 May 2023
29 Jun 2023
15 Jun 2023
Amount
SPECIAL REPAIRS B/R
Demolition of cement concrete of any description and in any position not otherwise specifically provided for
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required superficial area e. exc 150 sqcm but n exc 400 sqcm
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required superficial area n. exc 150 sqcm.
Demolition of stone slabs and tiles of any description or thickness laid bedded & pointed in any mortar in floors, aprons etc.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises
Taking up or down 40/50 mm bore steel water tubing and connections
Taking up or down 20 mm bore steel water tubing and connections
Dismantling of cast iron drain pipes, of 100mm dia fixed to wall or laid under floors complete all as directed.
Dismantling of cast iron drain pipes, of 75mm dia fixed to wall or laid under floors complete all as directed.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level)
Dismantling single layer Mangalore pattern, or similar tiles, any size in roofing/ chajjas in small patches upto fourth floor
All as per item No 14 here-in-before but from 5th to 8th floor height.
All as per item No 14 here-in-before but from 9th to 12th floor height.
Mini MP tiles, of size 228x152mm, Mangalore pattern, interlocking at side joints, laid in 10mm tick CM 1:4 screed mixed with liquid water proofing compound upto 4th floor height. Note : WPC will be measured and paid seperately.
All as per item No 17 here-in-before but from 5th to 8th floor height.
All as per item No 17 here-in-before but from 9th to 12th floor height.
Dismantling single layer Mangalore pattern or similar tiles in roofing/ chajjas in small patches and refixing it after replacing the new tiles upto 4th floor height.
All as per item No 20 here-in-before but from 5th to 8th floor height.
All as per item No 20 here-in-before but from 9th to 12th floor height.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Taking down chowkhat with shutter (without taking off shutters from the frames) not exc 1.5 sqm each
Taking down chowkhat with shutter (without taking off shutters from the frames) exc 1.5 sqm each.
Taking down shutter of any description exc 1 sqm and n exc 2 sqm each
Taking down shutter of any description exc 1 sqm and n exc 2 sqm each and refixing in same opening after repair complete all as specified
Dismantling of PVC water tanks n exc. 250 ltrs capacity
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Removal of existing deteriorated decayed tarfelt or any other treatment, loose surface & removing the debris outside MoD land complete all as specified.
Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed with grey cement with no pigment, set, jointed and pointed in 3mm epoxy over and including cement screed bed in CM 1:4, 20mm thick complete all as specified and as directed by the Engineer-in-Charge.
Cement concrete, 1:5:10, type E2, using 40mm graded stone aggregate as in filling under sunken floors complete all as specified.
40 mm thick PCC 1:2:4, type B1, using 20 mm graded stone aggregate as padding concrete in Sunken floor finished even and smooth without using extra cement complete all as specified
Water proofing treatment in sunken floors with two coats of brush bond of FOSROC or equivalent. Mix the part A and part B of the polymer modified cementitious coating mechanically using an electrically operated drilling machine fitted with mix paddle. Apply the same in two coats over the prepared surface one after the other dries up with a minimum interval of 4 hours between the coats. Providing pressure grouting in suspected areas of vertical and horizontal joints . The rate shall include all materials, machinery, labour etc. complete. NOTE : Contractor shall submit 10 years guarantee certificate for the water proofing treatment carried out.
Cement concrete type B1 1:2:4 (using 20mm graded aggregate) as in parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified.
20mm thick black colour granite (of approved quality) work (table rubbed and polished) over cooking platform in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite and edges shall be rounded off including cutting for sink and making holes for gas pipes, over 15mm thick screed bed in CM 1:4;complete all as specified and as directed. Note : Screed bed shall be measured and paid separately.
Polished black granite stone slab 18-20mm thick over 10mm thick backing coat in CM 1:3 on entrance of lift wall with fasterners of stainless steel or adhesive, including rounding of edges complete all as specified and as directed. Note : Backing coat shall be measured and paid separately.
Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:4 complete all as specified.
Rendering/backing coat 10mm thick in CM 1:3 on fair faces of brick work or concrete surfaces to receive wall tiles complete all as specified.
Anti skid rectified ceramic coloured designer tiles 400x400x7 to 8 mm thick laid in floors keeping 3mm wide tile joint set in neat cement slurry and pointed in white or coloured epoxy joint filler to match the shade complete all as specified.
Glazed rectified ceramic tiles in vertical surface 600x300x 7 mm thick set and jointed in neat cement slurry keeping 3mm wide tile joint by providing suitable PVC spacer and pointed in white or colour epoxy joint filler to match complete all as specified.
Anti - skid rectified ceramic coloured designer tiles 600x600x7 to 8 mm thick laid in floors set & jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
All as per item No 42 here-in-before but as in skirting complete all as directed.
Machine cut kota stone slab flooring / treads, 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror/beeswax polishing in small patches to replace existing broken pieces complete all as specified.
All as per item No 44 here-in-before but as in riser of steps in single piece, skirting, dado and pillar.
Beeswax polishing to existing kota stone flooring including preparation of surfaces complete all as specified and directed.
40mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floors & pavings complete all as specified.
38mm wide glass dividing strips, 3 mm thick inserted in position conform to design complete all as specified.
Rendering 10mm thick in CM 1:6 finished even & smooth without using extra cement complete all as specified.
Rendering 8mm thick in CM 1:4 using liquid WPC over 12mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished even & fair without using extra cement upto 4th storey complete all as directed. Note: Water proofing compound shall be measured and paid separately.
All as per item No 50 here-in-before but from 5th floor to 8th floor
All as per item No 50 here-in-before but from 9th floor upto 12th floor complete as directed.
Rendering 5mm thick in CM 1:3 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement as on ceiling complete all as specified.
Preparing newly plastered surfaces of wall & applying two coats distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of alkali resitant primer after preparing the wall surface by using SikaLatex or equivalent with cement slurry as per the manufacturer instructions over two coat of wall care putty (minimum thickness 1mm) and complete all as directed by Engineer-in-Charge. Note : The rates are including cement slurry.
Preparing newly plastered surfaces of ceiling & applying two coats distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of alkali resitant primer after preparing the wall surface by using SikaLatex or equivalent with cement slurry as per the manufacturer instructions and complete all as directed by Engineer-in-Charge. Note : The rates are including cement slurry.
Preparation of new plastered surface of wall and applying two coats of Acrylic exterior emulsion paint over a coat of alkali resitant primer using rollers made from foam or synthetic fibres over two coats of external cement putty (minimum thickness 1 mm), to get a smooth and tint free surface, upto 4 storey height complete all as specified and directed by Engineer-in-Charge.
All as per item No 56 here-in-before but from 5th floor to 8th floor complete as directed.
All as per item No 56 here-in-before but from 9th floor upto 12th floor complete as directed.
Complete removal of existing treatment surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, filling the cracks properly and finally washing with water jet of wall and applying two coat of Acrylic exterior emulsion paint over a coat of alkali resitant primer using rollers made from foam or synthetic fibres over two coats of external cement putty (minimum thickness 1 mm), to get a smooth and tint free surface, upto 4 storey height complete all as specified and directed by Engineer-in-Charge.
All as per item No 59 here-in-before but from 5th floor to 8th floor complete as directed.
All as per item No 59 here-in-before but from 9th floor upto 12th floor complete as directed.
Preparation of new tiles and applying 2 coats of weather coat tile protektor by Berger paints or equivalant approved manufacturer to MP roof / chajjas tile surfaces over a coat of primer to a desired finish complete all as specified by manufacturer's instructions upto 4th floor.
All as per item No 62 here-in-before but from 5th floor to 8th floor complete as directed.
All as per item No 62 here-in-before but from 9th floor upto 12th floor complete as directed.
Preparation of surfaces of old mangalore pattern roof tiles and applying two coat of weather coat tile protektor by Berger paints or equivalant approved manufacturer to MP roof / chajjas tile surfaces complete all as directed.
All as per item No 65 here-in-before but from 5th floor to 8th floor complete as directed.
All as per item No 65 here-in-before but from 9th floor upto 12th floor complete as directed.
Supply only liquid water proofing compound all as specified and directed
110mm bore PVC (SWR) pipes single socketed in any length with Stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls/ laid in floors all as specified and directed.
75mm bore PVC (SWR) pipes single socketed in any length with Stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls / laid in floors all as specified and directed.
S&F in repairs Unplasticised PVC pipes 40mm of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe
CPVC pipes 20mm, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary fittings/ joints complete all as specified.
All as per item No 72 here-in-before but 50mm dia.
S&F in repairs Unplasticised PVC pipes 25mm of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe
75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified.
110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified
75mm bore PVC (SWR) bends any radius complete all as specified
110mm bore PVC (SWR) bends any radius complete all as specified
110mm bore PVC (SWR) vent cowl complete all as specified
75mm bore PVC (SWR) vent cowl complete all as specified
S & F in repairs Vitreous China wash down water closet pan (pedestal pattern), white including 'P' or 'S' trap 100mm dia plastic water closet seat, black or white, closed pattern with flat bottom, seat cover and mild steel chromium plated or aluminised hinging device.(including fixing bolts but excluding flushing cistern and flush pipe)
S&F in repair vitreous China wash basin, white, flat back, size 580x450 excluding taps, waste, chain and plug and porcelain stopper but including brackets and 32mm dia PTMT waste complete
Toilet paper holder of CP fixed to walls with chromium plated (CP) brass screws complete all as specified
S & F in repair 75mm PVC (SWR) floor trap, with CP grating including jointing with solvent cement
S & F in repair 75mm PVC (SWR) multi floor trap, with CP grating including jointing with solvent cement
S & F in repairs 10 litres capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets & flush pipe.
S&F in repairs 32mm bore bottle trap of PTMT having minimum water seal of 25mm (minimum weight 32mm-260 gms/40mm-270 gms)
S & F in repairs PVC connections 15mm size with PTMT nuts of length 450mm
15mm bore CP fancy type pillar tap, Cat Part No CON 021K of Make Jaquar or equivalent in other approved makes for wash hand basin complete all as specified
Supply and fix in repairs, Health faucet (ABS body) with 1mtr long easy flex tube in chrome finish & wall hook complete all as specified, Cat Part No ALD 573 of Make Jaquar or equivalent in other approved makes .
Supply and fix in repairs, Soap dish any type fixed to plug with chromium plated fitted to walls with CP/ Brass screws all as specified and as directed by the Engineer-in-Charge. Cat Part No CAN 1131N of Make Jaquar or equivalent in other approved makes.
Supply and fix in repirs, Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed by the Engineer-in-Charge. Cat Part No ACN 1173 of Make Jaquar or equivalent in other approved makes
Supply and fix in repair tubular towel rail, brass chromium plated, 20mm dia, D type, 60cm long between flanges all as specified and as directed by the Engineer-in-Charge. Cat Part No CAN 1111SM of Make Jaquar or equivalent in other approved makes.
S & F in repair brass chromium plated shower rose 125 mm dia with 190 mm long arms, swivel joints including fixing to steel/ CPVC pipe or union. Cat Part No 495 & 483 of Make Jaquar or equivalent in other approved makes
3 layer loft tank (white colour) of 250 ltrs capacity including PVC float valve and all necessary fittings as specified and directed
S&F in repairs chromium plated bib taps 15mm bore fancy type, screwed down, screwed for iron pipe/ cpvc pipe or for brass ferrule and fixed. Cat Part No CON 107KN of Make Jaquar or equivalent in other approved makes
Two way long body CP bib cock quarter turn,15mm with wall flange complete all as specified. Cat Part No CON 041KN of Make Jaquar or equivalent in other approved makes
S&F in repair 15 mm bore chromium plated fancy type stop cock with long shank and cup (concealed type). Cat Part No CON 069FTK & ALD 069FT of Make Jaquar or equivalent in other approved makes.
S&F in repairs 15mm bore chromium plated fancy type angle stop valve with wal flange complete. Cat Part No CON 053KN of Make Jaquar or equivalent in other approved makes
Chromium plated single lever wall mixture with provision for overhead shower with 115mm long bend pipe on upper side, connecting legs and wall flanges complete all as specifed. Cat Part No CON 273 KNUPR of Make Jaquar or equivalent in other approved makes
S&F in repair 50 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for cpvc pipe
S & F in repair ball brass valves, high pressure, with polyethene float and flynut complete screwed for cpvc pipe of 50mm dia all as specified
4 way PVC gully trap 200mm with PVC grating of approved make complete all as specified
Demolition of precast cement concrete articles and precast concrete block walling built in cement mortar
Auto claved aerated concrete block Masonry in not exc 10cm thick complete set in CM 1:4. The block density of AAC block should be as per IS-2185 (Part – III): 1984. The minimum density should be 550 -650 Kg/Cum. Compressive strength of 2 to 4 N/mm2.
75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) in plinth protection, finished even and smooth w/o using extra cement complete all as specified
Reinforced cement concrete 1;2;4 type B1 (using 20 mm graded stone aggregate) for slabs supported on walls , beams and columns, in floors , roofs, landings and in shelves and the like complete with all necessary formwork etc all as specified
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
Mild steel TMT bars 8 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified
Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. with fair finished flat surfaces complete all as specified
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter to flat surfaces including fair finished surfaces complete all as specified
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors hung as gates, including pintle hinges, stops, hand-made sliding bolts, handles etc.; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc complete all as specified
Mild steel, plain, black sheet 1.6mm thick in wall cladding, steel gates and similar work, cut to size, fixed to steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required mild steel gates complete all as specified
Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required & hold fasts confirming to Fe-290 Grade-E-165 complete all as specified
Expansion anchors bolts 130mm long of dia not less than 16mm to masonry/ concrete walls all as specified and as directed by the Engineer-in-Charge.
6mm dia expansion screws closed eye hook anchors bolts to masonry/ concrete walls all as specified and as directed by the Engineer-in-Charge.
4mm thick PVC coated GI wire as in balcony cloth dryer having 2.5mm thick GI wire coated with 1.5mm thick standard PVC coating complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs aluminium single ladder 16' long having capacity of carrying load of not less than 120 kg conforming to IS 3696 (Part 2) - 1991 complete.
Hand rails, stainless steel pipe as on parapet top, drilled and counter sunk for balusters incl embedding in concrete & screwing drilling bolting welding riveting etc confirming to 316 L Grade complete all as specified
Anodised aluminium casement windows / ventilators, side hung type shutters without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as suitable imax hinges SS 304 grade (2 no.) and suitable handle (1no.) per shutter complete all as specified
Anodised aluminium frame for cupboards and shutter including joining cleat for fixing & push button handle set with key locking arrangement for shutter as approved by GE etc. complete all as specified
Anodised aluminium Deco grill, DG 101, 7mm thick (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved F channel section and fixed to the window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
Standard door eye viewer brass / CP of size 30/16 complete all as directed.
Floor door stopper overall length of 140mm, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor including vulcanised rubber piece complete all as specified
S&F in repairs, floor door stopper overall length of 140mm, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor including vulcanised rubber piece.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete as specified. (Size of the frame is 105x60mm) complete all as specified
All as per item No 127 here-in-before but size of the frame is 125x60mm
Second class hard wood ,plain,solid,straight chowkats and frames wrought framed rebated on the solid ,rounded or chamffered put together with glue pinned at joints supplied and fixed complete all as specified. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation
Flush door shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides as directed by Eingieer-in-Charge. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation
Second class hard wood, 35mm thick glazed and skeleton shutters with 8 panels, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation
Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified
S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
4mm thick sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane n exc .5 sq. m in each pane complete all as specified
S & F in repairs 4mm thick sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane n exc .5 sq. m in each pane complete all as directed
S & F in repairs 4mm thick sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane exc .5 sq. m in each pane complete all as directed
4mm thick sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane exc .5 sq. m in each pane complete all as specified
4mm thick figured sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane n exc .5 sq. m in each pane complete all as specified
S&F in repairs 4mm thick figured sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane n exc .5 sq. m in each pane
Butt hinges 100mm , medium weight, cold rolled and mild steel and fixed complete all as specified
S & F in repairs butt hinges 100mm , medium weight, cold rolled and mild steel
S & F 150mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified
S & F in repairs 150mm aluminium anodised, barrel tower bolts of extruded section and fixed
S & F 300mm size aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified
S & F in repairs 300mm size aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy
S & F 150mm aluminium handles, cast type, anodised complete all as specified
S & F in repairs 150mm aluminium handles, cast type, anodised
Preparation of new or previously untreated wood or wood based surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified
Preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described applying with two coats of synthetic enamel paint over a coat of red oxide or zinc chrome primer complete all as specified
S & F in repair curtain rods fancy type powder coated conduit not less than 18mm dia complete.
S & F in repair fancy type powder coated bracket suitable for curtain rods fancy type powder coated conduit not less than 18mm dia complete.
Dismantling boarding, any description, fixed in any position with nails
17.5mm thick Solid plain PVC Sheet suitably fixed as in shelves & partitions in cupboards with stainless steel screws & glue complete all as specified
5mm thick plain colour PVC sheet in Solid PVC Wall Lining inclusive of Solvent Cement and fixing at site complete all as specified
Pre lalminated medium density fibre board,12mm thick, exterior grade, fixed to aluminium frame with necessary pvc lipping, etc. complete all as specified
100 mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified
S&F in repairs 100 mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws
S&F 100mm aluminium handles, cast type, anodised complete all as specified
S&F in repairs 100mm aluminium handles, cast type, anodised
Mild Steel continuous hinges (Piano hinges), 30mm wide, bright finish or electro galvanised complete all as specified
S&F in repairs MS continuous hinges (Piano hinges), 30mm wide, bright finish or electro galvanised
SS magnetic door catches of locally avaiable best quality with screws complete all as specified
S&F in repairs SS magnetic door catches of locally avaiable best quality with screws complete
Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as specified
Preparing surface and treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc., area n exc 0.1 sq. m each complete all as specified
Post construction anti termite treatment a points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified
Stainless steel Kitchen Plate Rack of size 600 mm x 600 mm x 250 mm of 0.5mm thick fixed with plugs screws, washers and waster, including necessary Chipping/drilling holes to fix on wall suitable size in wall as per IS specification complete all as specified
S&F in repairs sinks made of stainless steel 1 mm thick kitchen or laboratory withy plugs, washer and waste coupler embedded in cooking platform, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm complete all as specified
Complete removal of existing treatment surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, filling the cracks properly and finally washing with water jet of wall and applying two coat of acrylic distempert over a coat of alkali resitant primer using rollers made from foam or synthetic fibres to get a smooth and tint free surface complete all as specified and directed by Engineer-in-Charge.
Preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint all as specified and directed.
Preparation of old painted steel & iron surfaces of any description, over 10cm in width or girth,and applying two coat of synthetic enamel paint complete all as specified.
Preparing old decorated surfaces of ceiling & applying one coat of white wash complete as directed.
Post construction anti treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors etc in ground floor complete all as specified and as directed by Engineer-in-Charge.
STRUCTURAL REHABILITATION
Scaffolding : Providing, erecting and dismantling safe Pipe scaffolding and / or H frame including working platform for external and internal area of building to facilitate all works with proper arrangements etc. complete. Measurement for payment shall be made in square meter of Scaffolding carried out.
Surface Preparation: Labour charges for Chipping off the corrosion damaged areas on the structural members. Clean reinforcement using Reebaklens RR of Fosroc or equivalent and make sure that there are no traces of rust on the surface of existing rebars. Check for the depth of carbonation using the phenolphthalein indicator and make sure that the contaminated concrete is removed completely. Clean the surface and make sure that surface is clean and free from loose particle. The rate shall include all materials, machinery, labour etc. complete.
Surface Preparation for Protective Coating of Wallgaurd: Removal of concrete/mortar spatters or protrusions on the wall surface using power grinding, removal of laitance, curing compounds, oil, grease, wax, algae & fungal growth and dirt/ dust accumulation on the entire wall surface to be coated with protective coating by using high pressure water jetting to achieve a wall Surface Profile compatible with primer coat, making the surface completely dry to receive the coating etc. The rate shall include all materials, machinery, labour etc. complete.
Anchoring column Main Reinforcement: Mark the position of holes to be drilled for anchoring the rebar into the floor/slab and beam. Drill 20mm dia holes in the marked places using rotary hammer drilling machine of reputed make to a depth of 75mm into the floor/slab and beam. Clean the holes neatly and wash the same with jet of water. Allow it to dry and make sure that no fine dust particles are present in the holes. Mix the base and hardener of the polyster resin Make Lockfix-S of Make FOSROC or equivalent in other makes using a spatula and push the same in to the holes with a proper tool so that the bottom most point of the hole receives the material. The filling is to be done for a minimum portion of 1/3rd of the hole depth. Now insert the rebar to be anchored for the provision of main reinforcement, gently and finish the surface around the rebar area using the same material which comes out of the hole excessively. The rate shall include all materials, machinery, labour etc. complete
Anchoring beam Main Reinforcement: Mark the position of holes to be drilled for anchoring the rebar into the floor/slab and column. Drill 20mm dia holes in the marked places using rotary hammer drilling machine of reputed make to a depth of 75mm into the floor/slab and column. Clean the holes neatly and wash the same with jet of water. Allow it to dry and make sure that no fine dust particles are present in the holes. Mix the base and hardener of the polyster resin Make Lockfix-S of Make FOSROC or equivalent in other makes using a spatula and push the same in to the holes with a proper tool so that the bottom most point of the hole receives the material. The filling is to be done for a minimum portion of 1/3rd of the hole depth. Now insert the rebar to be anchored for the provision of main reinforcement, gently and finish the surface around the rebar area using the same material which comes out of the hole excessively. The rate shall include all materials, machinery, labour etc. complete
Additional Reinforcement: Check the diameter of the existing rebars and if the diameter is less than 30% of the original diameter, provide additional reinforcement. Cut 12mm dia bars as main reinforcement to the required length with proper development length. Tie them to the prefixed shear connectors so that the additional rebar acts monolithically with the existing ones and core concrete. In the case of the shear reinforcement also, if the diameter of the rebars is reduced, provide 8mm dia stirrups in the form of 2 "U" shaped bars. Tie them properly so that it has a tight contact with the main bars. The rate shall include all materials, machinery, labour etc. complete.
Shear Connectors: Drilling 12mm dia holes up to a depth of 75mm maximum and fixing 8mm dia L shaped anchor rods as shear connectors at every 300mm c/c on the surfaces of the columns/beams or any other structural member as the case may be. Clean the same using water and make sure that there are no fine particles present in the hole. Mix the base and hardener of the polyester resin with the spatula thoroughly. Fill the drilled and cleaned holes to a minimum depth of 1/3rd of the hole with the prepared polyster resin Make Lockfix-S of Make FOSROC or equivalent in other makes. Make sure that the resin has reached till the end of the hole. At this stage push the shear connector gently in to the hole and finish the excess resin which comes out of the hole and allow the shear connectors not to be disturbed for minimum 20 minutes - complete. The rate shall include all materials, machinery, labour etc. complete.
Anti-corrosive Coating: Clean the rebars using the rust remover if there exists any rust, otherwise clean the rebar free of foreign material. Mix the base and hardener of the anti-corrosive coating like Nitozinc Primer of Fosroc or equivalent mechanically using a slow speed heavy duty drilling machine fitted with mixing paddle. Apply the mixed materials to the cleaned rebar and allow it to dry complete. The rate shall include necessary scaffolding and platform and cost of all the operations and etc complete. The rate shall include all materials, machinery, labour etc. complete.
Epoxy Jointing Compound: Clean the concrete surface, remove the loose particle if any. Make sure that the form work is ready for positioning. Mix the base and hardener of the epoxy resin jointing compound and apply the same to the prepared surface. Care should be taken that the micro concrete needs to be done within 5 hours maximum from the time of application of epoxy jointing compound Nitobond EP of Fosroc or equivalent. The materials should have the fallowing properties: Specific gravity of which is 1.15 to 1.2 gm/cc, Compressive Strength (BS 6319 Pt 2) is 50MPa (@ 7day), Flexural Strength (BS 6319 Pt 3) is 35MPa (@ 7day), Shear Strength (BS 6319 Pt 4) is 10MPa (@ 7day). The rate shall include all materials, machinery, labour etc. complete.
High Strength Polymer Mortar (SP40) - 75mm thick. Renderoc SP40 of Fosroc or equivalent, ready to use blend of dry powders which is formulated for application, repair mortar suitable for most structural and load bearing repairs as per manufacture specification. The rate shall include all materials, machinery, labour etc. complete.
Polymer Modified Mortar 40mm thick Cement Mortar 1:3 Wet the surface with potable water and make sure that the surface is kept moist so that the water cement ratio in the polymer modified mortar is maintained. Supply and application of Nitobond SBR or equivalent as per manufacture specification. The rate shall include all materials, machinery, labour etc. complete.
Drilling and Fixing of Nozzle: Make groove at every 150-mm c/c in the brick masonry wall perpendicular to the direction of crack. Provide 20 mm dia nozzle for the grouting. Provide 8 mm dia reinforcement perpendicular to the direction of the crack. The rate shall include the cost of all the operations and etc complete.
Injection of Cement grout: Prepare AR mortar in the ratio of 1:3. Add 1 litre of Nitobond AR per bag of cement or any equivalent to the above mortar mix and apply to the primed concrete surface using a trowel. The dosage of AR shall be 1 lit per bag of cement. Grout the same using cement grout mixed with copolymer (SBR) of 1 lit per bag of cement and cut the nozzle after completing. Fill up the crack using the same and followed by a smooth finish. The rate shall include the cost of all the operations and etc complete.
Curing Compound: Immediately after striking the form work or after completion of the repair works, the surface should be sprayed water once and followed by application of membrane based curing compound like Concure WB of Fosroc or equivalent diluted with water in the ratio of 1: 1 as a curing membrane - Complete. The specific Gravity of which is 1.025 to 1.04 gm/cc and Slant Shear (BS 6319) is 20 MPa. The rate shall include all materials, machinery, labour etc. complete.
Water Proofing with Brushbond: All the surfaces which are to receive the waterproofing coating like Brushbond, must be free from dirt or any other form of foreign matter which might affect adhesion. Acid wash and water wash the surface and allow it to surface dry condition. Mix the part A and part B of the polymer modified cementitious coating mechanically using an electrically operated drilling machine fitted with mix paddle. Apply the same in two coats over the prepared surface one after the other dries up with a minimum interval of 4 hours between the coats. Providing pressure grouting in all the vertical and horizontal joint including the suspected areas. The rate shall include all materials, machinery, labour etc. complete. NOTE : Contractor shall give 10 years guarantee for the water proofing treatment carried out.
Protective Plastering: Prepare cement sand mortar in the ratio 1:4 with waterproofing liquid (Conplast X421 IC manufactured by M/s Fosroc Chemicals or equivalent) as per the dosage of the manufacturer and apply the same as protective screed to prevent mechanical damage while laying the weathering course, tiles etc.
Protective Coating Wall guard: Clean the surface with wire brush and remove all dirt and dust. The surface should also be completely dry. The contents of Nitocote Wallguard shall be thoroughly stirred for atleast 2 minutes using a slow speed (300 - 400 RPM) drilling machine attached with a mixing paddle. Apply Nitocote Wallguard with a nylon brush, or a felt roller, to the primed substrate. Allow Nitocote Wallguard first coat to dry for 5-6 hrs at 300 C and then apply the second coat. Nitocote Wallguard shall be applied at theoretical application rate 3 to 3.5 m2/ litres for 2 coats. The rate shall include all materials, machinery, labour etc. complete.
Debris Removing: Remove the debris from the spot followed by stacking at the ground floor and carting away the same from the site complete. The cost including the loading the debris to the vehicle.
INTERNAL ELECTRIC SUPPLY
Taking down copper/aluminium point wiring from(light,fan, socket or power) complete including fixture and fitting such as switches, ceiling roses,pendants, regulators, sockets etc. removing meterials to store for keeping in safe custody or for taking cerdit (credit for above items should be made as per conditions seperatly) and making good distrurbed surface of wall, floors etc.
Taking down old unserviceable single phase sub main wiring of any size including making good the disturbed surface of wall/ floors matching the existing surface of wall or floors.
Taking down old unserviceable MCB DB TPN/ SPN with MCBs including making good the disturbed surface of wall/ floors matching the existing surface of wall or floors.
Point wiring drawn in and including rigid non metallic PVC conduit on surface/wall with medium grade, ISI marked of suitable dia, with 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw, cup washer & including PVC insulated & unsheathed stranded copper condutor of 1.5 Sqmm as continuous earth wire complete for One light point/ point controlled by one switch complete all as specified.
All as per item No 200 here-in-before but for one Exhaust Fan controlled by one switch
All as per item No 200 here-in-before but for One fan point by one switch and regulator
All as per item No 200 here-in-before but for One bell point controlled by one switch
All as per item No 200 here-in-before but forOne 5 Amps socket outlet point on same board alongwith other switch.
All as per item No 200 here-in-before but forOne 5 Amps socket outlet point on independent board controlled by one switch.
All as per item No 200 here-in-before but for one light point controlled by two way switch
Point wiring in and including rigid non metallic PVC conduit on surface/wall, ISI marked of suitable dia, with 4 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw , cup washer & including PVC insulated & unsheathed stranded copper condutor of 4.0 Sqmm as continuous earth wire complete all as specified
Point wiring drawn in existing nonmetallic PVC conduitwith 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw, cup washer & including PVC insulated & unsheathed stranded copper condutor of 1.5 Sqmm as continuous earth wire complete for one light point/point controlled by one switch complete all as specified
All as per item No 208 here-in-before but for one Exhaust Fan controlled by one switch
All as per item No 208 here-in-before but for One fan point by one switch and regulator
All as per item No 208 here-in-before but for One bell point controlled by one switch
All as per item No 208 here-in-before but for One 5 Amps socket outlet point on same board alongwith other switch.
All as per item No 208 here-in-before but for One 5 Amps socket outlet point on independent board controlled by one switch.
All as per item No 208 here-in-before but for one light point controlled by two way switch
Point wiring in existing nonmetallic PVC conduitwith 4 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw , cup washer & including PVC insulated & unsheathed stranded copper condutor of 4.0 Sqmm as continuous earth wire complete 15 Amps Socket outlet point on independent board controlled by one switch all as specified as directed. all as specified as directed.
Point wiring in and including rigid non metallic PVC conduit on surface/wall, ISI marked of suitable dia, with 2.5Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw , cup washer & including PVC insulated & unsheathed stranded copper condutor of 2.5 Sqmm as continuous earth wire complete 15 Amps Socket outlet point on independent board controlled by one switch all as specified as directed.all as specified as directed.
Point wiring in existing nonmetallic PVC conduitwith 2.5 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw , cup washer & including PVC insulated & unsheathed stranded copper condutor of 2.5 Sqmm as continuous earth wire complete 15 Amps Socket outlet point on independent board controlled by one switch all as specified as directed.
Switch flush type single pole, one way, 6 Amps, ISI marked all as specified
Switch flush type single pole, two way, 6 Amps, ISI markedall as specified
Socket outlet, 3 pin, 5 Amps flush type, ISI marked all as specified
Switch socket combination 2in 1 , 5 pin 6 Amp flush type, ISI marked complete all as specified.
Switch socket combination 2 in 1 , 3 pin 15 Amps and 3 pin 5 Amps flush type, ISI marked complete all as specified.
Ceiling rose three terminals suitable for 240 Volts, ISI marked complete all as specified.
Lamp holder, PVC/Polycarbonate type with cord grip cap, ISI marked suitable for pendant fittings all as specified and directed.
Bell push, flush type, 5 amp, ISI marked all as specified and directed.
Buzzer, Ding Dong AC. 230 volts, single pole, ISI marked all as specified and directed.
LED lights fitting 1x 20W, 220V,AC decorative box type PVC body with driver, holder including LED tube light connecting up with three core flexible opper conductor cable of suitable size from ceiling rose complete all as specified.
LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified.
Decorative type wall light fixture made up of polycarbonate with 9 W retrofit LED lamp complete all as specified.
LED bulb of 9 Watts 6500 K suitable for fixing in lamp holder complete all as specified.
Electronic type fan regulator switch & step type, 240 V , AC double module, ISI marked complete all as specified.
Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete including making necessary provisions for mounting on existing walls incl taking down old unsv exhaust fans handover to MES store complete all as specified.. Note : Rate deemed to be inclusive of cutting of wall or any civil works required at site.
Rewinding of ceiling fan 1200/1400 MM sweep by dismantling of fan motor, cutting and removing of burnt windings, cleaning the motor slots, rewinding the motor with supper enameled copper wire of appropriate gauge, provision of insulation paper, applying of varnish, heating / baking the motor to acheive the proper insulation resistance and reassembling and refixing the fan in original location complete all as specified and directed
Supply and fix in repairs blades of suitable size to fit with body of existing ceiling fan of sweep 1200/1400mm all as specified and as directed by the Engineer-in-Charge
M&L for Cleaning of ceiling fan assembly of any type/size and carrying out two coat of spray painting with first quality synthetic enamelled paint of approved colour, including writing of MES number in black paint complete all as directed and specified.
Metal clad box suitable for 230 Volt 50 Hz AC supply three pin with MCB SP 20 Amps complete all as specified and as directed by the Engineer-in Charge
Preparation for old surface of LT panels applying two coats of Eppoxy painted siemens grey any size of panel all as specified and directed
SPN distribution board factory made Double door flush type all as per IS 8623 made from sheet metal duly powder coated 12 way to be fixed flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge.
SPN distribution board factory made Double door flush type all as per IS 8623 made from sheet metal duly powder coated 4 way to be fixed flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge.
S&F in repairs RCCB of current rating 25 A ,30 ma sensitivity , short circuit current rating 6 KA Double pole all as specified and directed by Engineer-in-Charge.
MCB SPN 32-40 Amp, 240 volts of 10 KA rupturing capacity, C-curve type as out going all as specified.
MCB SP 6 to 32 Amp, 240 volts of 10 KA rupturing capacity, B-curve type as out going including taking down of existing unserviceable all as specified.
MCCB, FP 100 Amps,25kA with rotary type handle and necessary arrangements for fixing in the bus bar trunking system including taking down existing all as specified and as directed
MCCB, FP 160 Amps,35kA with rotary type handle and necessary arrangements for fixing in the bus bar trunking system all as specified and as directed
Sub main wiring with 2 single core PVC insulated unsheathed 1100 Volt grade multistranded copper conductor of size 6 Sq mm drawn through incl provn of PVC conduit fixed on wall/ surface and accessories and 6 sq mm copper conductor cable as earth continuity conductor and connected to common earth dolly. Note : 03 Runs of 6 Sqmm multistranded copper conductor PVC insulated unsheathed and one run of PVC conduit medium grade shall be measured as one unit.
Sub main wiring with 2 single core PVC insulated unsheathed 1100 Volt grade multistranded copper conductor of size 4 Sq mm drawn through provn of PVC conduit fixed on wall/ surface and accessories and 4 sq mm copper conductor cable as earth continuity conductor and connected to common earth dolly. Note : 03 Runs of 4 Sqmm multistranded copper conductor PVC insulated unsheathed and one run of PVC conduit medium grade shall be measured as one unit.
Sub main wiring with 2 single core PVC insulated unsheathed 1100 Volt grade multistranded copper conductor of size 6 Sq mm drawn in through existing PVC conduit and 6 sq mm copper conductor cable as earth continuity conductor complete all as directed and specified. Note : 03 Runs of 6 Sqmm multistranded copper conductor PVC insulated unsheathed shall be measured as one unit.
Sub main wiring with 2 single core PVC insulated unsheathed 1100 Volt grade multistranded copper conductor of size 4Sq mm drawn in through existing PVC conduit and 4sq mm copper conductor cable as earth continuity conductor complete all as directed and specified. Note : 03 Runs of 4 Sqmm multistranded copper conductor PVC insulated unsheathed shall be measured as one unit.
Earthing complete with GI earth plate electrode 600 x 600 x 6mm size burried directly in ground earth pit not less than 2.25Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to GI wire 4 mm as earth lead by means of bolts ,nuts ,checknuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specfied or indicated including testing on completion with excavation earth pit, PCCcover watering pipe etc., including taking down of old earth plate complete all as specified.
M&L repair to unserviceable storage water heaters (Geyser) of 25 to 50 ltr capacity and taking down, replacing defective parts with new parts and refixing after clearing the defects and make it operational complete all as specified and directed. Note: (i) Replacement of parts will be measured and paid as supply only seperately. (ii) The cost of labour and consumables required for replacement of parts, arc or gas welding for tank leakages & painting shall deem to include in unit rate quoted by the contractor.
Supply only thermostat suitable for 25/50 ltr capacity Geyser complete all as specified
Supply only geyser inlet and outlet assembly for 25/50 liters capacity geyser compete incl all fixing accessories complete all as specified
Supply only pressure release valve suitable for 25/50 ltr capacity Geyser 8 bar complete all as specified
Supply only heating element 1.5KW/2KW suitable for 25/50 Itr capacity Geyser as per site requirements compatible with any brand of geyser complete all as specified
Supply only mounting bracket assy suitable for 25/50 ltr capacity Geyser complete all as specified
Supply only SS inner tank suitable for 25 ltr capacity Geyser complete all as specified
Supply only 3 core 2.5 sqmm PVC flexible multi stranded copper condutor cable suitable for Geyser complete all as specified
Supply only connection pipe 15mm dia 450mm long for hot/cold water both end connected with screwed brass nut complete all as specified
Supply only neon indicating lamp suitable for 25/50 ltr capacity complete all as specified
Building security light luminaries 35 W LED 6 K environment friendly long life versatile pressure die cast aluminium IP 65 luminaire with high power LEDs light source and electronic driver complete watts including suitable size GI brackets GI tube of length 1.2 m and mounting accessories all as specified and as directed by Engineer -in-charge.
FIRE FIGHTING
Supplying, fixing in repairs, testing and commissioning of Gunmetal Ball valve 25mm dia PN 1.6 withrubber insertion nuts, Steel Ball with hand lever operated screwed end conforming to IS 554
Supplying and fixing in repairs, testing of weather proof Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard and locking arrangements suitable to accommodate internal hydrant with 2 Nos 15 Mtrs long hose pipe, 2 No. branch pipe, fittings etc.The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of post office red externally and white internally and shall be suitably mounted on concrete bases. NOTE : Hose pipe, Branch pipe and fittings shall be measured and paid separately.
Supplying, fixing, in repair testing and commissioning 63mm dia 15 mtr long Hose Pipe (Hose Pipe shall be of synthetic fibre) confirming to IS 636 complete with male and female coupling confirming to IS 903 complete all as specified and directed
Supply, installation in repair gun metal 63mm dia short Branch Pipe with 15mm bore nozzle of gunmetal having screw threaded and hexagonal head conforming to IS903 with ISI mark
Supplying, fixing in repair First Aid Hose Reel wall mounting swinging type complete with drum, bracket, gate valve/ stop cock and 19mm dia 30mtr long high pressure hose reel tubing of Thermoplast Type II hose conforming to IS12585 with ISI mark with gunmetal shutt off nozzle with 5mm orifice
Supplying, fixing in repair Gun metal Fire Brigade Inlet 4 way connection for connecting to external fire hydrant ring main consisting of four nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories.
Supplying, fixing, in repair testing and commissioning of Industrial type Pressure Switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc complete as required
Supply only in repair Pressure Gauge 100mm dia with ball valve of pressure of 14Kg/Sqcm , 3/8" BSP bottom entry,weather proof with stainless steel internals,siphon tube and ball valve including fittings complete all as specified and directed.
Supply , laying, testing and commissioning of 'C' class heavy duty 100 mm dia MS pipe conforming to IS:1239 I/c fittings like elbows, tees, flanges, tapers, nuts, bolts,gaskets etc fixing the pipe on the wall/ ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete incl taking down old unserviceable pipe as required.
Supplying, fixing,in repair horizontal type Cast Iron Dual plate Non-return valve 100 bore of approved quality conforming to API-594 standards with nuts, Bolts, Washers etc complete as required.
Supply & fix yard hydrant post / stand post 80mm Dia GI / MS both flanged type 1.5mtr height incl taking down old unsv complete
Supply & fix air release valve 50mm dia suitable for fire fighting wet raiser system incl taking down old unsv complete
M&L for scrubbing of existing paint from all mettalic surfaces of existing fire fighting system per building and applying two coats of scarlett red synthetic enamelled paint over a coat of mettalic primer complete
Supplying, fixing, in repair Fire Hydrant Landing Valve type A (Single Head Outlet) type with SS female coupling valve conforming to IS:5290-1993 having 80mm dia inlet with PVC Cap and locking mechanism.
Supply and fix in repairs Fire Alarm sounders / Sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 meter with sound output variation of + 5 DB for 500 meter range
Supply and fix in repairs Addressable manual call point resettable type with relay module with hammer complete
Supply and fix in repairs 2 core 1.5 sqmm armoured FR LS copper condutor suitable for complete all as specified
Supply and fix in repair fire alarm control panel complying with BSEN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules per loop complete all as specified
M&L for Servicing of induction motor 10 HP coupled with pump complete including re-winding with same gauge of copper wire as per OEM recommendation inl greasing replacement of wornout rubber packing, bearing wornout nuts and washers etc and complete
LIGHTNING PROTECTION
Taking down old GI/Al strip any size with connecting accessories like insulator, air termination rod screws etc complete all as per direction of Engr - in - charge
Air termination, single pointed, aluminium rod 12 mm dia and 300 mm long complete all as specified
Galvanised iron strip 32 x 6 mm buried in ground /fixed on wall complete all as specified.
Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified.
Llight grade galvanised iron pipe 40mm bore with all fitting and fixed to walls/laid in floors/trench complete including taking down old material.
Light grade galvanised iron pipe 20mm bore with all fitting and fixed to walls/laid in floors/trench complete including taking down old material.
Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 03 Nos, 8 mm dia 25 mm long hex head screw in smc enclosure/junction box including taking down old material complete all as specified.
M&L for repair/ replacement of earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI strip 32x6mm mm by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I including taking down old materials of earthing.
AVIATION OBSTRUCTION LIGHT
Hot press moulded SMC enclosure/junction box, 200 mm x 140 mm x 95 mm size, door fixed with hinge on one side for fixing of test terminal block including taking down old junction box/ enclosure.
Integral LED aviation obstruction light comprising of aluminium housing with polycarbonate enclosure Make/ model- Bajaj BGAV 302 LED or equivalent in other approved makes, along with programmable lux base timer switch of make Nature TS/Kakatiya/ABB and one MCB SP 32A, incl one contactor of 04 pole 25 Amps AC, 240 volts of 06 Amps fixed in a wall bracket enclosure including taking down old U/S material.
Supply, laying testing cable XLPE insulated, screened, PVC RM bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6.0 sqmm 2 core including taking down old unserviceable material
EXTERNAL WATER SUPPLY
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 40 mm complete all as specified and directed.
CPVC pipes, SDR 11, 50 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets ,Threaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc
S&Fin repair 50 mm gun metal globe/gate valves, with CPVC body, screwed/pasted both ends for CPVC pipe, complete including taking out old valves all as specified.
Supplying, fixing and testing of Ductile Iron, heavy duty, Specials of any size, radius and length confirming to IS - 1538 Part - I to XXIII: 1976 such as bends [any type, radius and angle], tapers any type [straight, bend, increasing, decreasing or double socket etc], sockets, tail pieces, connecting pieces, tee pieces, single branch, "Y" junction, double branch, cross, [all sockets or socket and spigot or Flanged], collars, caps and plugs, ( required for shape as per site )adopters etc suitable for CI / DI Spigot and Socket or Flanged pressure pipes complete including taking down of existing item all as specified and as directed.
Supply and fix in repairs Ball brass valves,high pressure,50 mm bore with polythenefloat and flynut complete,screwed for iron pipe or brassferrule and fixed
Star Construction Co.
ROY CONSTRUCTION CO
FUTURE ONE FACILITY MANAGEMENT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .