Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance SHOP NO 55 GROUND FLOOR ROHINI SECTOR 7 NAHARPUR FLOOR HARLAL MARKET NAHARPUR SECTOR 7 DELHI OPP GOYAL GARMENTS VILLAGE TOWN DELHI CITY DELHI | Admitted-Finance |
| 3 | Rejected-Technical 153 PKT 21 SECTOR 24 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Rejected-Technical FDR not submitted |
Tender Value
Refer Docs
EMD Value
₹20,600
Closing Date
9 Mar 2023, 11:30 amClosed
ADDL. CHIEF ENGINEER (M)-4
ADDL. CHIEF ENGINEER (M)-4
S/I/T/C of monobloc pump set with allied accessories for on line booster at Gulabi Bagh in AC-18.
2023_DJB_237488_1
NIT No. 25 Item No. 11 (22-23) EE (T)/ACE
Open Tender
Miscellaneous Works
Works
30 days
ADDL. CHIEF ENGINEER (M)-4
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Account No SB 50448339804
₹20,600
15 Mar 2023
2 Mar 2023
9 Mar 2023
2 Mar 2023
9 Mar 2023
2 Mar 2023
Horizontal 20 H.P. monobloc water pump set of discharge flow rate-2940 LPM to 1260 LPM at 14-to-30-meter head range with C.I. impeller gland packing, sealing C-40 shaft TEFC motor, IP-55 “F”-class insulation Sleeve coupled with 20 HP, 3000 rpm, 3 phase, 415-volts TEFC motor, size of suction & delivery-125x125 mm with MS base frame. Make of Pump set: KBL,Lubi,ABB and any approved make of DJB
Casting of RCC foundation of size 0.5 mtr x 1 mtr. x 0.5 mtrs. with the help of Iron Bars & C:C in the ratio 1:1.5:3. The work i/c fixing /grouting of MS foundation nut bolts of suitable size including welding of foundation bolts with the Iron Bars.
Supply of MS pipe of 125 mm dia. 08 mm thickness. MAKE: Any approved make of DJB
Supply of M.S. flange 125 mm dia. 08 mm thickness
Rubber insertions for 125 mm dia. pipe joints. D J B SOR Code1374
Supply of M.S Nut bolts washer. D.J.B. S.O.R: Item Code1034
Supply& fixing of anti-vibration mounting pads as required.
Supply of 125 mm dia. bends made out from 8 mm thick MS Sheet, dully welded and having flanges with holes on both sides
Supply & fixing of foundation bolts as required.
Supply of PVC insulated Flexible Copper Conductor 35 sq.mm three core cable for above pump set to connect motor to starter. Make: Havells, Polycab, Grandley and any approve make of DJB
Supply of PVC insulated Aluminum armored 50 sq.mm three core cable for main to panel Make: Havells, Polycab, Grandlay and any approve make of DJB
Supply of automatic star-delta starter in SS enclosure, output voltage: - 415 Volts, three phase for 20 H.P. pump set. Make: - L&T, C&S, Havells, BCH and any approved make of DJB
S/o MCCB 415V, three pole 3phase, high breaking capacity 50KA 50Hz, rating-250Amp. Make: L&T/Siemens/Havells/BCH and any approved make of DJB
Providing and fixing 25x5mm G.I. strip on surface or in recess for connections etc. as required.
Supply of 125 mm dia. NRV PN 1.0. Make: - Kirloskar / IVC / DJB Approved make
Supply Non rising Sluice valve of size 125 mm, PN 1.0 Make: - Kirloskar / IVC / DJB Approved make
Packing and transportation charges of the Pump set. This includes shifting of the complete pump set from shop to site and transportation and loading unloading cost done with the help of manual labor.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp). For 50 sq.mm
Making the required incoming power supply connections between main supply and new incomer panel by connecting the cable after relaying of cable and re -thimbling of cable ends as per requirement.
Fixing the pump set over the base frame with the help of tools & tackles with the help of heavy labour as per site. MS pipe including fixing of suction & delivery along with valve, NRV with the help of the gas cutter, welding m/c including welding rods and other tools & tackles etc. complete in all respect as per site requirement
Testing and commissioning of pump set as per required parameters with relevant IS testing of the starter prior to switching on as follows. Continuity and earth testing. Meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth. Checking for all tightness of nut and bolts.
The staff to be deployed of 03 Nos. operator (Semi-skilled) including contractor profit, ESIC & EPF per day for operation for pump set at on line booster DDA Flat Gulabi Bagh
Goodwill Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .