Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.3 LAccepted-AOC 9 463 SANA MANZIL PUNNAPRA PO ALAPPUZHA 688004 | ALAPPUZHA | ALAPPUZHA | KERALA | 688004 | ₹21.3 L | 1 | Accepted-AOC lowest bidder |
| 2 | 2₹24.7 L+₹3.3 L (15.7%)Rejected-Finance | ₹24.7 L+₹3.3 L (15.7%) | 2 | Rejected-Finance QUOTED AMOUNT HIGHER THAN L1 |
| 3 | 3₹25.5 L+₹4.2 L (19.8%)Rejected-Finance KERALA INDIA 682030 | ERNAKULAM | KERALA | 682030 | ₹25.5 L+₹4.2 L (19.8%) | 3 | Rejected-Finance QUOTED AMOUNT HIGHER THAN L1 |
| 4 | 4₹26.5 L+₹5.1 L (24.1%)Rejected-Finance | ₹26.5 L+₹5.1 L (24.1%) | 4 | Rejected-Finance QUOTED AMOUNT HIGHER THAN L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical not submitted documents proving eligibility criteria |
| Sl No | Description | Qty | Unit | HARIFUDEEN L1 | R. Sajikumar L3 | ABDUL RAZIK L2 | HARIS KA L4 |
|---|---|---|---|---|---|---|---|
| 1.00CONSTRUCTION OF AUDITORIUM civil works | |||||||
| 1.01 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge. In cement mortar | 5.25 | Cu mtr | 10,500 ₹12,390 | 9,712.5 ₹11,460.75 Lowest | 11,025 ₹13,009.5 | 11,177.25 ₹13,189.15 |
| 1.02 | 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand) | 21.7 | Sq mtr | 7,595 ₹8,962.1 | 7,378 ₹8,706.04 Lowest | 8,029 ₹9,474.22 | 8,007.3 ₹9,448.51 |
| 1.03 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with matching epoxy filler materials etc., complete. Size of Tile 1200x600 mm (As per 11.41.4) | 214.61 | Sq mtr | 4,50,681 ₹5,31,803.58 | 3,30,499.4 ₹3,89,989.29 Lowest | 6,00,908 ₹7,09,071.44 | 6,86,752 ₹8,10,367.3 |
| 1.04 | Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm | 46.65 | Sq mtr | 93,300 ₹1,10,094 Lowest | 2,09,925 ₹2,47,711.5 | 1,49,280 ₹1,76,150.4 | 1,76,663.55 ₹2,08,462.99 |
| 1.05 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | 373.89 | Sq mtr | 78,516.9 ₹92,649.94 | 54,214.05 ₹63,972.58 Lowest | 82,255.8 ₹97,061.84 | 83,751.36 ₹98,826.6 |
| 1.06 | For shutters of doors, windows & ventilators including
providing and fixing hinges / pivots and making provision for fixing of
fittings wherever required including the cost of EPDM rubber/
neoprene gasket required (Fittings shall be paid for separately)
Polyester powder coated aluminium (minimum thickness of polyester
powder coating 50 micorn) | 12.68 | Kg | 8,876 ₹10,473.68 | 8,559 ₹10,099.62 Lowest | 8,876 ₹10,473.68 | 9,116.92 ₹10,757.97 |
| 1.07 | Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard tubular
sections/ appropriate Z sections and other sections of approved
make conforming to IS : 733 and IS: 1285, fixing with dash fasteners
of required dia and size, including necessary filling up the gaps at
junctions, i.e. at top, bottom and sides with required EPDM rubber/
neoprene gasket etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically wherever required
including cleat angle, Aluminnium snap beading for glazing
/paneling, C.P. brass/ stainless steel screws, all complete as per
architectural drawings and the directions of Engineer-in
charge.(Glazing, paneling and dash fasteners to be paid for
separately): For fixed portion Polyester powder coated aluminium (
minimum thickness of polyester powder coating 50 micron | 68.75 | Kg | 40,562.5 ₹47,863.75 | 39,531.25 ₹46,646.88 Lowest | 40,906.25 ₹48,269.37 | 40,906.25 ₹48,269.37 |
| 1.08 | Providing and fixing false ceiling with 7.5 mm thick PVC wooden
grains panel board ceiling of approved quality in aluminium frame
work with necessary screws etc complete. Including aluminium
frame work (As per 50.12.4.2) | 245.43 | Sq mtr | 2,94,516 ₹3,47,528.88 Lowest | 5,03,131.5 ₹5,93,695.17 | 3,04,333.2 ₹3,59,113.17 | 3,09,241.8 ₹3,64,905.32 |
| 1.09 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 6.00 mm thickness (As per 21.3.2) | 40.42 | Sq Mtr | 64,672 ₹76,312.96 Lowest | 1,19,239 ₹1,40,702.02 | 64,672 ₹76,312.96 Lowest | 67,178.04 ₹79,270.09 |
Tender Value
₹25.9 L
EMD Value
₹25,896
Closing Date
16 Sept 2025, 5:00 pmClosed
MANAGING DIRECTOR
FOAM MATTINGS INDIA LTD PB NO 4619 BEACH ROAD ALAPPUZHA
CONSTRUCTION OF AUDITORIUM AT FOAM MATTINGS (INDIA) LTD ALAPPUZHA
2025_FMIL_795055_1
FOMIL/PROJ/AUDITORIUM/2025
Open Tender
Civil Works - Buildings
Item Wise
90 days
ALAPPUZHA
AS PER TENDER DOCUEMENT
2 documents required · 2 mandatory
₹6,111
Yes
₹25,896
Yes
12 May 2026
9 Sept 2025
18 Sept 2025
9 Sept 2025
16 Sept 2025
9 Sept 2025
9 Sept 2025 - 16 Sept 2025
CONSTRUCTION OF AUDITORIUM civil works
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge. In cement mortar
12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with matching epoxy filler materials etc., complete. Size of Tile 1200x600 mm (As per 11.41.4)
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm
Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portion Polyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron
Providing and fixing false ceiling with 7.5 mm thick PVC wooden grains panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete. Including aluminium frame work (As per 50.12.4.2)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 6.00 mm thickness (As per 21.3.2)
Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Electrical works -Conduit laying and associated works
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Electrical works -wiring and acessories
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,1.5 sq.mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Electrical works -fittings and installations
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supply, installation, testing and commissioning of 24W down lighter, recess mount 18-Watt Round/square LED down lighter fitting, Voltage: 240 VAC, Shape:‎Round/square, 4000-6500 CCT, 100 lm/W, CRI<80
Supply Conveyance, installation, testing and commissioning of 100W LED Flood ight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Electrical works - cable and acessories
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 6 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
Supply and installation of 4 sq mm to 16 sq mm. 60 mm long x 12 mm wide x 1 mm thick Copper earthing clips for single compression glands and giving all connections.
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 35 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
Electrical works - earthing and associated works
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
Supply and fixing of copper bench including necessary hole drilling and provision to connect earthing conductors. 20mm x 3 mm Cu tape completing with all respects as required.
Supply and fixing of copper earthing test joint including necessary hole drilling and provision to connect earthing conductors. 20mm x 3 mm Cu tape completing with all respects as required.
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
Electrical works - DB and Acessories
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing Cable End Boxes (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with testing and commissioning etc. as required.For 10 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required
Electrical works - main panel connection works
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
ABDUL RAZIK (BID ID -2340061)
R. Sajikumar (BID ID -2341486)
HARIS KA (BID ID -2337835)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
retenderdocumentauditoriumwork.pdf
Tender Documents • 0.38 MB
BOQ_1314424.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .