| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.2 LAccepted-AOC 10 SUBASH COLONY DEF LAB ROAD RATANADA JODHPUR 342006 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L1 | Accepted-AOC L1 | |
| 2 | L2₹99.6 L+₹24.4 L (32.4%)Rejected-Finance 1ST FLOOR SCO 35 CHAURA BAZAR ZIRAKPUR PUNJAB | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | Projenix Private Limited L2 | PANWAR ELECTRICALS L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling taking down old unserviceable Chiller plant 21TR of 3 Nos plants complete including motor, pump, pipe line, Valves , ducts , diffusers and dampers and depositing it in MES store and making good the disturbed portion complete all as specified and directed by Engr in Charge
Note: Rate quoted is for 3 nos of chiller plant. | 1 | Each Job | 33,925 ₹33,925 Lowest | 51,000 ₹51,000 |
| 2.00 | Design ,Supply , install , commissioning and testing of Water Cooled Scroll Chillers, with multi compressors, comprising of Semi - Hermetic/Hermetic/ Open Type Compress-ors, DX Evaporator, Shell and Tube Condenser,suitable expansion device,suitable for operation on R - 22 /R - 407 C/R 410a for existing rooms which were airconditioned at Site
of nominal capacity not less than 21 TR (each) with circulation rate of 610 LPM(160 GPM)(nominal) or as recommend by OEM each comprising of the following complete as per specification and as reqd.
Compressor automatic capacity control, safety switches, forced feed lubrication insulated chiller, ,water flow switch , vibration isolators, integral refrigerant piping and wiring , automatic and safety controls mounted in central console panel and all mounted on a steel frame (complete as per specifications). shall be suitable for 415volt 50Hz cycles. 3 phase AC supply. including all required accessories as per specifications.
Note :(i) Contractor has to submit ,get the design of Chiller plant approved from accepting officer before incorporating the same on ground.
(ii) The design condition of the plant should be able to meet the desired temeprature of 22°C+2 °C , with RH of 55% +5% as per the weather conditions of Halwara during Summer, Monsoon & Winter.
(iii)The plant is to be designed such that to meet the desired temperature with 2 units run at a time and 01 will be standby. ( 02 working & 01 Standby).
(iv) The Air changes is to be calculted for Hospital rooms as applicable per Indian Standards or as appliacble
Refrigerant - R-134A/ R - 407 C/R 410A
Evaporator fouling factor -0.0001 (British Units)
Condenser fouling factor-0.00025 (British Units) ( 2 units working & 01 standby) | 3 | Each Job | 7,39,972 ₹22,19,916 Lowest | 9,11,000 ₹27,33,000 |
| 3.00 | Design ,Supply, installation, testing and commissioning of electrical Hot water Generator of vertical construction equipped with sufficient number of flanges and electric emersion heaters. The pressure vessel shall be constructed as per ASME standards and insulated on all sides with 50 mm thick fiberglass with 0.6mm Aluminium cladding as per specifications.The hot water generator shall be equipped with all automatic and safety controls such as manual reset, high temperature water cutout, step controller, on/off switch, pilot light,low water cut off and other controls as per manufacturers recommendations.All basic controls and terminals shall be located in an integral control cabinet factory wired and tested. The hot water generator shall be suitable for 415 volts, 50 Hz, 3phase power supply.The entire hot water generator shall be factory assembled and tested including 02 Nos Hot water generator pump of suitable capacity.
Note :(i) Contractor has to submit ,get the design of Hot water generator approved from accepting officer before incorporating the same on ground.
(ii) The design condition of the plant should be able top meet the desired temeprature of 22°C+2 °C , with RH of 55% +5 % as per the weather conditions of Halwara during Summer, Monsoon & Winter. | 1 | Each Job | 1,67,251 ₹1,67,251 Lowest | 2,00,000 ₹2,00,000 |
| 4.00 | Design,Supply, installation,commissioning and testing of induced drafttop discharge counterflow type FRP Cooling Tower(Rectangular/Roundbottle shape) with FRP body and base, water spray headers, coolingtower fills, fan withmotor, supporting baseframes, as permanufacturer's standard instructions suitable for Chiller plant designed as mentioned in item ser No 2 with the cololoing tower capacity not less than 50 TR. The cooling tower should have the following features FRP Water basin, PVC Filling with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow type fan-direct driven or driven through reduction gear box with TEFC induction motor with high efficiency class , suction screen, make-up quick fill arrangement, overflow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling tower interior,
Range: 4.2 Deg. C/ 7.5 Deg. F
Condenser water inlet/outlet temp-90-97 Deg F
Wet Bulb Approach: 2.78 Deg. C/ 5 Deg. F | 1 | Each Job | 1,49,270 ₹1,49,270 Lowest | 3,00,000 ₹3,00,000 |
| 5.00 | Design ,Supplying, erection, testing and commissioning of chilled water pump set for chilled water suitable for plant as mentioned in Item ser No 2 above. The pump to be disigned with 2 working and 01 standby concept. The pumpset to have followiung specifications TEFC squirrel cage induction motor with class 'F' insulations & efficiency class EFF1 4pole synchronous speed , operating on 415 volts ,3 phase , 50 Hz A.C .suply.Min. pump efficiency at duty conditions shall not be less than 75% | 3 | Each Job | 71,921 ₹2,15,763 | 40,000 ₹1,20,000 Lowest |
| 6.00 | Design ,Supplying, erection, testing and commissioning of Condensor water pump set capable of delivering 360GPM /1360LPM of water against a head of 22 mtr or as recommended by OEM. Each pump shall comprise of following as required as per specifications. The scope of work shall positioning of pump at location shown on drawing. (1w+1s)
End suction Horizontal monoblock type
, TEFC squirrel cage induction motor with class 'F' insulations & efficiency class EFF1 , 4pole synchronous speed , operating on 415 volts ,3 phase , 50 Hz A.C .suply.Min. pump efficiency at duty conditions shall not be less than 75% | 2 | Each Job | 81,420 ₹1,62,840 | 45,000 ₹90,000 Lowest |
| 7.00 | Design Supply, install,commissioning and testing of Double Skin factor fabricated Air Handling Unit with Cooling Coil following sizes fabricated out of extruded aluminium section with 0.8 mm pre-plasticized/ pre-coated Galvanised steel sheet outside & 0.8 mm plain Galvanised steel sheet inside with blower sections and blower motors TEFC, B class insulation and IP 55 protection suitable for operation on 415 volts ± 10%, 50 Hz AC supply, pre-filter section with non wovensynthetic media of 10 micron particle size and MERV-13 fine filter section with non wovensynthetic media of 5 micron particle size with combined efficiency of filters to be 95%, Coil section with Cooling coil, Heating coil compitible with modulating cooling thermostate sandwitch type drain pan made out of 18 G stainless steel sheet inside and 22 G G.I sheet outside with 25mm thick insulation, Motor and belt drive package . The blowers should be AMCA Certified for air performance and sound rating and should be selected for maximum efficiency.
The Air Handling Unit panels shall be insulated with 25mm thick & 36 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 152 MPM maximum. The capacity of AHU unit shall as per specification.
Floor Mounted AHU not less than -16000 CFM at 50 mm static pressure with suitable row coil for Chilled water & Addl coil as reqd for Hot water complete all as specified and Directed | 1 | Each Job | 5,50,942 ₹5,50,942 Lowest | 8,50,000 ₹8,50,000 |
| 8.00Chilled Water Insulated Pipe | |||||
| 8.01Supply and lay M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings (with necessary clamps, vibration isolators and fittings). | |||||
| 8.02 | 100 mm dia | 6 | RM | 2,203 ₹13,218 | 1,700 ₹10,200 Lowest |
Tender Value
₹76.6 L
EMD Value
₹1.4 L
Closing Date
20 Apr 2026, 6:00 pmClosed
HQ CWE (AF) Bhisiana
HQ CWE (AF) Bhisiana
SPECIAL REPAIR TO BER AC PLANT OF OT AND COLD CABINETS IN MORTUARY AT AF STN HALWARA UNDER GE (AF) HALWARA
2026_MES_748167_2
CWE(BHI)/HAL-52/2025-26
Open Tender
Civil Works
Works
334 days
Halwara
As per tende documents
8 documents required · 8 mandatory
₹1,000
GE(AF) Halwara
₹1.4 L
Yes
1 Jun 2026
7 Apr 2026
22 Apr 2026
7 Apr 2026
20 Apr 2026
14 Apr 2026
7 Apr 2026 - 9 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Dismantling taking down old unserviceable Chiller plant 21TR of 3 Nos plants complete including motor, pump, pipe line, Valves , ducts , diffusers and dampers and depositing it in MES store and making good the disturbed portion complete all as specified and directed by Engr in Charge
Note: Rate quoted is for 3 nos of chiller plant. | 1 | Each Job | - | - |
| - | Design ,Supply , install , commissioning and testing of Water Cooled Scroll Chillers, with multi compressors, comprising of Semi - Hermetic/Hermetic/ Open Type Compress-ors, DX Evaporator, Shell and Tube Condenser,suitable expansion device,suitable for operation on R - 22 /R - 407 C/R 410a for existing rooms which were airconditioned at Site
of nominal capacity not less than 21 TR (each) with circulation rate of 610 LPM(160 GPM)(nominal) or as recommend by OEM each comprising of the following complete as per specification and as reqd.
Compressor automatic capacity control, safety switches, forced feed lubrication insulated chiller, ,water flow switch , vibration isolators, integral refrigerant piping and wiring , automatic and safety controls mounted in central console panel and all mounted on a steel frame (complete as per specifications). shall be suitable for 415volt 50Hz cycles. 3 phase AC supply. including all required accessories as per specifications.
Note :(i) Contractor has to submit ,get the design of Chiller plant approved from accepting officer before incorporating the same on ground.
(ii) The design condition of the plant should be able to meet the desired temeprature of 22°C+2 °C , with RH of 55% +5% as per the weather conditions of Halwara during Summer, Monsoon & Winter.
(iii)The plant is to be designed such that to meet the desired temperature with 2 units run at a time and 01 will be standby. ( 02 working & 01 Standby).
(iv) The Air changes is to be calculted for Hospital rooms as applicable per Indian Standards or as appliacble
Refrigerant - R-134A/ R - 407 C/R 410A
Evaporator fouling factor -0.0001 (British Units)
Condenser fouling factor-0.00025 (British Units) ( 2 units working & 01 standby) | - | Each Job | - | - |
| - | Design ,Supply, installation, testing and commissioning of electrical Hot water Generator of vertical construction equipped with sufficient number of flanges and electric emersion heaters. The pressure vessel shall be constructed as per ASME standards and insulated on all sides with 50 mm thick fiberglass with 0.6mm Aluminium cladding as per specifications.The hot water generator shall be equipped with all automatic and safety controls such as manual reset, high temperature water cutout, step controller, on/off switch, pilot light,low water cut off and other controls as per manufacturers recommendations.All basic controls and terminals shall be located in an integral control cabinet factory wired and tested. The hot water generator shall be suitable for 415 volts, 50 Hz, 3phase power supply.The entire hot water generator shall be factory assembled and tested including 02 Nos Hot water generator pump of suitable capacity.
Note :(i) Contractor has to submit ,get the design of Hot water generator approved from accepting officer before incorporating the same on ground.
(ii) The design condition of the plant should be able top meet the desired temeprature of 22°C+2 °C , with RH of 55% +5 % as per the weather conditions of Halwara during Summer, Monsoon & Winter. | - | Each Job | - | - |
| - | Design,Supply, installation,commissioning and testing of induced drafttop discharge counterflow type FRP Cooling Tower(Rectangular/Roundbottle shape) with FRP body and base, water spray headers, coolingtower fills, fan withmotor, supporting baseframes, as permanufacturer's standard instructions suitable for Chiller plant designed as mentioned in item ser No 2 with the cololoing tower capacity not less than 50 TR. The cooling tower should have the following features FRP Water basin, PVC Filling with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow type fan-direct driven or driven through reduction gear box with TEFC induction motor with high efficiency class , suction screen, make-up quick fill arrangement, overflow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling tower interior,
Range: 4.2 Deg. C/ 7.5 Deg. F
Condenser water inlet/outlet temp-90-97 Deg F
Wet Bulb Approach: 2.78 Deg. C/ 5 Deg. F | - | Each Job | - | - |
| - | Design ,Supplying, erection, testing and commissioning of chilled water pump set for chilled water suitable for plant as mentioned in Item ser No 2 above. The pump to be disigned with 2 working and 01 standby concept. The pumpset to have followiung specifications TEFC squirrel cage induction motor with class 'F' insulations & efficiency class EFF1 4pole synchronous speed , operating on 415 volts ,3 phase , 50 Hz A.C .suply.Min. pump efficiency at duty conditions shall not be less than 75% | - | Each Job | - | - |
| - | Design ,Supplying, erection, testing and commissioning of Condensor water pump set capable of delivering 360GPM /1360LPM of water against a head of 22 mtr or as recommended by OEM. Each pump shall comprise of following as required as per specifications. The scope of work shall positioning of pump at location shown on drawing. (1w+1s)
End suction Horizontal monoblock type
, TEFC squirrel cage induction motor with class 'F' insulations & efficiency class EFF1 , 4pole synchronous speed , operating on 415 volts ,3 phase , 50 Hz A.C .suply.Min. pump efficiency at duty conditions shall not be less than 75% | - | Each Job | - | - |
| - | Design Supply, install,commissioning and testing of Double Skin factor fabricated Air Handling Unit with Cooling Coil following sizes fabricated out of extruded aluminium section with 0.8 mm pre-plasticized/ pre-coated Galvanised steel sheet outside & 0.8 mm plain Galvanised steel sheet inside with blower sections and blower motors TEFC, B class insulation and IP 55 protection suitable for operation on 415 volts ± 10%, 50 Hz AC supply, pre-filter section with non wovensynthetic media of 10 micron particle size and MERV-13 fine filter section with non wovensynthetic media of 5 micron particle size with combined efficiency of filters to be 95%, Coil section with Cooling coil, Heating coil compitible with modulating cooling thermostate sandwitch type drain pan made out of 18 G stainless steel sheet inside and 22 G G.I sheet outside with 25mm thick insulation, Motor and belt drive package . The blowers should be AMCA Certified for air performance and sound rating and should be selected for maximum efficiency.
The Air Handling Unit panels shall be insulated with 25mm thick & 36 Kg/m³ density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 152 MPM maximum. The capacity of AHU unit shall as per specification.
Floor Mounted AHU not less than -16000 CFM at 50 mm static pressure with suitable row coil for Chilled water & Addl coil as reqd for Hot water complete all as specified and Directed | 1 | Each Job | - | - |
| - | Chilled Water Insulated Pipe | - | - | - | - |
| - | Supply and lay M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings (with necessary clamps, vibration isolators and fittings). | - | - | - | - |
| - | 100 mm dia | - | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
Tender52.pdf
Tender Documents • 1.43 MB
BOQ_850662.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .