Loading…
Loading…
Tender Value
₹19.0 L
EMD Value
₹19,500
Closing Date
9 Jun 2026, 6:00 pm3d left
The Superintending Engineer, Project Implementation Unit
Providing & Erecting New Stretcher Lift in New construction of CHC building at Hansot, Ta.:- Hansot, Dist.: Bharuch. [Reinvite 01-03
310477
30/01 of 2026/2027
Open
Electrical
Gandhinagar
8 documents required · 8 mandatory
₹900
PIU-General Fund A/c 11-114
₹19,500
2 Jun 2026
2 Jun 2026
2 Jun 2026
9 Jun 2026
2 Jun 2026
Providing & Erecting New Stretcher Lift in New construction of CHC building at Hansot, Ta.:- Hansot, Dist.: Bharuch. [Reinvite]
Qty ITEM DESCRIPTION Unit Rate Rate in words Amount
(A) GENERAL DESCRIPTION OF LIFTS.
[1] GEAR LESS LIFT DRIVE (MRL) comprising of High Starting torque Lift
3 phase 440 V A. C. Permanent Magnet Synchronous motor of proper rating
with high efficiency shall be used.[2] Micro processor based / PLC, ACVVVF,
vector control drive with encoder feedback closed loop system shall be used for
lift car and door operation which shall be full collective selective operation hall
call demand response, UP/DOWN hall stops, Main, Up/ Down Contactor with
overload and phase reversal relay and safety controls.
[3] Car with M S platform with bracings of adequate size and to sustain the
impact load cabin + passenger with safety factor of fire for steel and side panels
of Stainless steel of sheet of grade 304 duty. Car ceiling will be S.S. finishes
with aesthetic appearance with LED ceiling lights. Car flooring shall be of s/s
304 chaker plate design sugeested of engineer in charge. of engineer in
charge. Car doors shall be of stainless steel grade 304, hairline finish with
centre opening / telescopic automatic doors. Car panel will also be S.S.
finished with emergency stop device, mechanical door safety device,
facility of auto/ attended mode. All car panel buttons and all floor switches
must be with brail language as per lift act.
Qty ITEM DESCRIPTION Unit Rate Rate in words Amount
[4] All landing doors must be fire rated for 2 hour shall be fully automatic
centre opening/ telescopic opening made of hairline finish steel grade of
with key holes and infrared curtains with Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car along with alarm
switch shall be provided. Also, Emergency Light & Fan should start
immediately without any Time Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow along with floor
position indicator shall be provided inside the car and at all floors.
[7] Full height infra red curtain with multiple cross / crossing light beams shall
[8] Automatic Rescue Device (ARD) shall be provided accordingly of
passenger capacity with Manual Rescue Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over loading shall be
provided such that doors kept open till excess load is removed.
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic sleep timer shall be
[12] Voice annunciator with suitable music shall be provided in lift car.
[13] Self diagnostics system for operational and safety parameters shall be
provided in control panel.
[14] Mechanical over speed governor with governor calibration as per actual
site parameters and submission of calibration certificate submission, door key
holes in the floor doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine room and monkey
ladder for lift pit should be provided by the lift agency, along with the other
steel structure works, foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without any extra cost,
where ever required as / if directed by engineer in charge.
Qty ITEM DESCRIPTION Unit Rate Rate in words Amount
[17] Permanent wiring with necessary safety devices like RCCB in all circuit,
Over Voltage Under Voltage protection and THD eliminator in circuit for lift
machine room and lift well with proper numbers of light points, with fixtures,
exhaust fan and plug points shall be provided by the agency. Only 3 phase
Power Supply shall be made available by department in lift machine room.
Necessary Earthing as per Lift Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and alteration in lift shaft and
machine room related to erection of lift shall be made by lift agency without
any extra cost. (granite/marble fixing around all landing door openings are not
in lift agency’s scope.)
[19] Agency has to provide all working drawings and documents and liaison
services for obtaining all necessary permission from lift inspector and other
authorities. [20] acrylic transparent licence/display A4 size holder in lift
[20A] As per statutory requirement of Govt. Of Gujarat lift & escalator act
2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor. 4.carrying out third party lift
inspection during/after lift erection and provide report by third party authorized
by concern licensing authority 5.agency has to provide third party insurance
upto completion of free maintenance period and submit the document for the
Qty ITEM DESCRIPTION Unit Rate Rate in words Amount
[21] Car Panel Operating Buttons with floor position indicator/buttons must be
of Auto Glow type clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full Length Handrails of hairline
finish steel grade of 304 should be provided at appropriate height on the Rear
& Side Wall Panels in Lift Car. [23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your controller, drive and all equipments
[24] Necessary rating of DP Elcb and FP Elcb required for lift is in scope of
work which rating is sugested by CEICED Department (electrical
(B) SPECIAL FEATURES DESCRIPTION OF LIFTS for PREMIUM
1. Advanced control system dual 64 bit embedded microprocessor with
CANBUS Serial Communication mode including Regenerative power efficient
operation,on site programming facility, Anti nuisance, Pte-opening, BMS/RMS
with necessary online real time monitoring system having necessary
connectivity for remote monitoring & other suitable supporting hardware &
software devices to fulfil the purpose.
2. Floor Indication LCD Display with call registration & brail mark with arrival
gong and hall lantern & TFT Screen in the car with MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive SS Moonrock finish / Hair Line /
Honeycomb for car and all Doors, All landing doors must have fire rating up to
2 hours and car door must have multi-level crisscross beam door protection.
4. To & fro communication system & wiring (i.e. car , control room & guard
room ) and Each elevator are equipped with remote monitoring system.agency
has to provide mobile app and user id and password for monitoring
15/16 Passengers Stretcher Lifts, Ground plus 2 upper floor with Rated Speed Rupees Nineteen Lakh
13-1- Three thousand Three
1 1 of 1.0 m/sec., (C) With General PLUS ADDITIONAL SPECIAL FEATURES Ea. 1903349.04 hundred Forty Nine Paise
attached herewith. Prem. Cat. Four Only
Qty ITEM DESCRIPTION Unit Rate Rate in words Amount
In Words:- Rupees Nineteen Lakh Three thousand Three hundred Forty Nine Only
Dy.Executive Engineer (Elect.) Executive Engineer (Elect.)
P.I.U., Zone-6, Bharuch P.I.U., Zone-6, Vadodara
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
schedule b Lift hansot estimate (1).pdf
Standard Specification for Electrical Work (1) (1).pdf
Tender Notice No - 30.pdf
0.SBD Book lift.pdf
12. hansot lift PQ.pdf
6372 Make List (1)_compressed.pdf
Download all tender documents and submit your bid