Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹15.2 L+₹2.3 L (17.6%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹15.5 L+₹2.6 L (19.9%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹22.2 L+₹9.3 L (72.2%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
3 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 969 EWS
GE 969 EWS C o 56 APO
MANNING AND OPERATION OF CHS HOT WATER PLANTS INCL REPAIR AND MAINT OF INSTALLATION AND ALLIED INFRA AT BARAMULLA UNDER GE 969 EWS
2020_MES_391500_2
CANO 969/WS- /2020-21
Open Tender
Civil Works
Item Rate
182 days
Baramulla
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹30,000
Yes
14 Jan 2021
31 Oct 2020
5 Dec 2020
31 Oct 2020
3 Dec 2020
16 Nov 2020
60 days
Amount
Manning and operation of 1 x CHS (Location Arty Bde) , comprising of 01 number each hot water generator of Rapid cool capacity 1,00,000 K Cal/Hr with all safety devices/ accessories and mountings etc (16 Hrs in two shifts i.e. in two shifts of eight hours each) including de-scaling/de-carbonising of generator fortnightly with, adjustment of burner assembly, safety devices, draining/operation of water control valves as shown at site to avoid freezing effect in lines, emergency light arrangement, access to valve with ladders etc. Complete all as specified and directed by Engr-In-Charge. Note: i The contractor has to employ 01 ( one) FGM per shift of 8 (eight) hours for 2 (two) shifts (i.e. total 2 FGMs per day for two shifts) for carrying out the duties, shift Hrs as decided by EIC and the contractor shall not have any claim what so ever on this account.
General Notes for Contracts (Sch 'A' item 1) :- (i) The rate quoted by the Contractor should be inclusive of minimum fair wages, applicable tax liabilities, expenses towards EPF, ESIC, uniform, overheads and profits. (ii) The contractor must pay minimum fair wages as per Govt of India Ministry of Labour and Employment latest notification to all employees/workers. (iii) The contractor shall deduct workers subscription towards provident fund and ESIC, as per rule and shall deposit the same alongwith his contribution into respective accounts of workers and shall submit details to GE for verification (iv) Contractor will make the payment of (FGM/Electrician/Helper) in their bank account through ECS/NEFT/Cheque. Bank statement in respect of payment made to all employed FGM/Electrician will be submitted before claiming RAR payment. (v) Contractor will present all the tradesmen to GE with their ITI and experience certificate for approval of their suitability for the job before employing them. (vi) ID proof and police verification of all labour/operator/supervisor be submitted in GE office immediately after acceptance of tender to issue security pass. (vii) Contractor will provide proper uniform as per PS Clause No 15 or as approved by GE to all their employed FGM/Electrician/Helper. (viii) Refer PS Clause 10.4 for minimum penal recovery for non operating and or non-maintaining installations. (ix) Weekly off to workers shall be given and cost of reliever is deemed to include in quoted rate.
M&L for topping up of glycol concentrate along with the necessary additives and inhabittor in cognition and supplied in barrels, the mixture freezing temperature should be -30 Deg. Complete all as specified and directed by Engr-In-Charge.
Material and labour for disconnecting the filter bed from the indoor unit of AC's of various sizes cleaning the filter beds & copper fins, removal of complete dirt deposited inside the cooling coil fins area by spary of scale removing agent and flushing out with fresh water till removal of complete dirt from the fins area and flushing out with air bolwer and refixing the same in existing position. Complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for chemical servicing of the out door unit of 1.5/2 TR capacities by dismantling the sheet metal parts, apply the organic compound of scale remover to the air cooled condenser fins & tube area, and flushing through forced method, till removal the complete scale deposit across the fins & tube and cleaning, fixing the sheet metal parts, fan blades, etc. Complete all as specified and directed by Engr-In-Charge.
Material and labour for taking down unserviceable burnt compressor, Supply and fixing scroll type new compressor of existing unit make suitable for 1.5/2 TR air cooled split type unit and rectify the control wiring defects if any, connecting back all controls and refrigerant piping after necessary modification as required for system, pressure testing with nitrogen gas under constant pressure of 300 PSI Kg/sq.cm for minimum 08 hours vacumising, gas charging, commissioning and checking the performance of the system. Complete all as specified and directed by Engr-In-Charge.
S&F in replacement of hard drawn copper pipe size suitable for existing one and connecting with indoor to outdoor unit of AC plant along insulating rubber sleeves and including brazing. Complete all as specified and directed by Engr-In-Charge.
Repair/ Maintenance of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. Complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. Complete all as specified and directed by Engr-In-Charge.
Supply and charging of refrigerant gas M -22/R-134 upto sufficient pressure for compressor of 1.5 ton capacity window type /split type ACs including connected works like pressure testing with nitrogen before filling of refrigeratn gas including cutting of copper tubing and brazing and refixing in position complete. Complete all as specified and directed by Engr-In-Charge.
Dismantling old and unsv air swing fan motor and replacing with new one suitable for 1.5/2 ton capacity split AC. Complete all as specified and directed by Engr-In-Charge.
Dismantling old unserviceable condenser fan motor suitable for 1.5/2 ton capacity window /split type AC and replacing by new one of existing make and model. Complete all as specified and directed by Engr-In-Charge.
S&F in replacement PCB card for indoor unit of same model amd make suitable for 1.5/2 TR capacity split type units. Complete all as specified and directed by Engr-In-Charge.
Attending complaints / servicing including trouble shooting /repair of geyser 25 to 50Ltrs capacity checking of serviceability of individual parts such as thermostat, heating element, pressure release valve, inlet/outlet connections etc, replacing worn-out fasteners and defective components and testing including taking down the geysers and refixing the same after repairs. Complete all as specified and directed by Engr-In-Charge. Note : Spare parts including replacement will be measured and paid separately under relevant item of Sch'A' and rate quoted shall include replacement of worn-out fasteners.
Supply only heating coil of geyser / Solar water heater all as per existing make / model / size conforming to relevant IS,cap 1.5 KW any type (round/tringle).
All as per item no. 14 above but cap. 2 KW any type (round/tringle).
Supply only thermostat for any type /make/capacity of geyser .
Supply only water inlet & outlet assembly complete of any type /make of geyser complete for capacity 50 Ltrs.
All as per item no 17 above but cap 25 Ltrs.
Supply only pressure release valve 15mm dia with new one for any type /make/capacity of geyser .
Supply only PVC flexible connection of 15 mm dia 600 mm long with check with new one suitable for cold/hot water connection of geysers.
Supply only Indicator Lamp of RED / GREEN Suitable for Water Heater.
S&F in repairs GI tubing 15mm dia medium grade in short length with all fittings complete to walls, or laid on roofs including taking down existing unserviceable pipes. Complete all as specified and directed by Engr-In-Charge.
S&F in repairs stop valves, fancy type chromioum plated,cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends with iron pipes of 15mm bore. Complete all as specified and directed by Engr-In-Charge.
S&F in repairs 20 mm Non return valves, cast copper alloy, for GI pipes. Complete all as specified and directed by Engr-In-Charge.
Cleaning the surface of geysers 25 / 50 Ltrs capacity to free from dust, grease and preparing surfaces for painting and spray painting with synthetic enamel paint of existing colour including writing MES No. Complete all as specified and directed by Engr-In-Charge.
Taking the copper or steel container carefully from the geyser, descaling, rectifying leakage by brazing, resetting the insulating (glass wool), testing for the required for pressure, replacing rubber gaskets, worn-out fasteners etc,. with new ones. Complete all as specified and directed by Engr-In-Charge.
S&F in repairs MCB Single pole, 240 volts 5 to 30 Amps 10 KA rupturing capacity for Acs and Geysers of various ratings. Complete all as specified and directed by Engr-In-Charge.
S&F in replacement of single pole and neutral Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps, 240 Volts, AC,50 HZ, Complete all as specified and directed by Engr-In-Charge.
All as per srl item No-29 above but for voltage stabilizer upto 63 KVA capacity.
All as per srl item No-29 above but for voltage stabilizer upto 160 KVA capacity.
Supply only control cards for output supply of voltage stabilizer of capacity upto 160 KVA.
Supply only control cards for input supply of voltage stabilizer of capacity upto 160 KVA.
Supply only control card for high voltage cut off protection reduction of voltage and automatic ON after 10 second time delay.
Supply only servo motor complete including pinion for voltage correction having speed of correction 8 volts per second of capacity upto 10 Kg torque.
Supply only dimmer for servo stabilizer of capacitie upto 160 KVA
Supply and fixing indicator lamps to show RYB phase of 3 phase 415 volt 50 Hz AC supply as replacement of defective indicator lamp in existing panel. Complete all as specified and directed by Engr-In-Charge.
Material and labour for complete rewiring for power and control circuit of voltage stabilizer using standard copper wire, replacement of thimbles, connectors numbering of wiring to all control and measuring instrument for capacity upto 160 KVA voltage stabilizer. Complete all as specified and directed by Engr-In-Charge.
M&L for filling /toping up of oil in servo voltage stabilizer having dielectric strength upto 35KVA at 2.5mm gap high voltage as per IS/IEC specification of low viscosity. Complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement of burnt defective LT copper coil of stabilizer with new one made out of suitable size/guage of copper super enamelled wire of high quality matching with the existing impendence and insulation including testing. Complete all as specified and directed by Engr-In-Charge.
M/S KULWANT SINGH RAINA AND CO
M/S GHULAM RASOOL LONE AND SONS
M/s SONA ULLAH LONE AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .