Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹10.0 L+₹31,825 (3.30%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹10.5 L+₹80,925 (8.39%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹11.3 L+₹1.6 L (16.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹11.3 L+₹1.7 L (17.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
25 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(KH) YOL
GE(KH) YOL, YOL CANTT, HP
Repair/Replacement of LT electric supply network and misc works at Lower Garrison at YOL CANTT
2022_MES_554715_1
GE/Y-40/2022-23
Open Tender
Civil Works
Item Rate
180 days
YOL CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(KH) YOL
₹20,000
Yes
30 Nov 2022
27 Sept 2022
27 Oct 2022
27 Sept 2022
25 Oct 2022
11 Oct 2022
Amount
Dismantling/ taking out old unserviceable cable of any size and removing from site, complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 240 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified. Note for Srl item Nos. 02 to 07:- (i) Excavation and earth work, sand cushioning, brick work, pipe, cable cover shall be measured and paid separately. (ii) All XLPE cable connected to any LT panel/bus bar should be proper size of cable gland and thimble including quoted rates.
Excavation in trenches n.exc 1.5 metres wide and n.exc 1.5 metres deep and getting out in any type of soil, all as specified.
Returning filling in including spreading leveling, watering and well ramming in layers n. exc 25cm, all as specified.
Removal of excavated material to be distance n.exc 50m and depositing where directed at a level n.exc 1.5m high from the starting point, all as specified.
Sand cushioning to under ground cables, 8cm thick layer before laying and testing the cable and 15cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I and directed by Engr-in-Charge.
Sub class 'B' bricks old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Laying only retrived bricks as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Mild steel galvanised light grade 50mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Mild steel galvanised light grade 80mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
MCCB 4 pole with fixed thermal and fixed magnectic release, 400 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with adjustable thermal and fixed magnectic release, 250 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with thermal and fixed magnectic release, 160 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with adjustable thermal and fixed magnectic release, 100 Amps having rupturing capacity 36 KA, including taking out old, complete all as specified and directed.
MCCB 4 pole with adjustable thermal and fixed magnectic release, 63 Amps having rupturing capacity 16 KA, including taking out old, complete all as specified and directed.
Re-stretching of ACSR conductor and earth wire of any size and type on HT/ LT poles including disconnecting and re-binding with insulators with suitable size of binding wire after re-stretching, connecting jumpers, adjusting line dividers etc complete all as specified and directed. (Each line to be measured)
Triming of tree branches after taking shut down from power house, 1.0 metre apart from HT/LT line carefully and considering the span from pole to pole, complete with cleaing the whole area grabbed by the trimed branches of tree, complete all as specified.
Cleaning of installation area from inside and outside by removing bushes, shurbs, grass and other vegetation materials by screaching out earth surface, cleaning the fungus formation and nearby growth of wild vegetation, bushes to a distance of 50 metres away all as specified and directed.
Supply, installation, testing and commissioning gang operated air break off load connecting switch HT, 11KV, tripple pole, each plate consisting galvanised steel base, verticle type mounted on 12 No's post insulators and steel frame, non ferrous knife and spring loaded contacts, arcing horns complete with dropout fuse element assembly, operating rod of GI pipe, medium grade, 20mm dia (without joint) of suitable size and locking arrangement, connections, mild steel frame with PG clamps and sleeves etc required for current rating 200 amps capacity including taking down unservicable air break gang operated switch complete, all as specified and directed.
Supply, installation, commissioning and testing bus chamber factory made Outdoor type, CPRI approved, size 0.45mx0.75mx0.4m deep, fabricated out of 3.15mm thick mild steel sheet and vermin proof with neoprene gasket having front opening and locking arrangement mounted on angle iron legs made of angle iron size 40mmx40mmx6mm, 0.40 mtrs above GL and 0.40 Mtrs embbeded in PCC block of size 0.30mtrsx.30mtrsx0.50mtrs 04 Nos with IP-54 protection as per IS-8623, duly powder coated (Internally and externally) having aluminium bus bars of 200 Amps rating duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and copper cable connection with all incoming and outgoing cable connection with suitable size of lugs and glands including one No MCCB with adjustable thermal and fixed magnetic release of capcity of 125 amps, 415 volt, 25 KA, 4 pole, as per makes mentioned in Appendix 'C'), including led phase indicator for three phase including taking down old unservicable chamber all as specified. Note Contractor shall submitt the drawings of bus bar champer showing arrangement of MCCB, cable gallery, Bus bar chambers over all dimensions and marked all items to be incorporated in to LT panel for approval of accepting officer. Engineer-in-charge shall ensure that LT busbar shall be made as per approved Drgs only.
Cable route indicator made out of 2mm thick mild steel of size 20cmx15cm duly coated with two coats of black paint over a coat of red oxide primer duly written the size of HT/LT cable in white paint and welded to equal angle of size 30mmX30mmX3mm, 45cm long and errected in ground in such a way that it is 15cm above ground level and 30Cm below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregate of size 15cmx20cmx45xcmm, complete all as specified. Note:- Cost pf PCC and earh work and excavation shall be deemed to be included in unit rate quoted by contractor.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 sqmm, including taking down old wire complete all as specified.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 16 sqmm, including taking down old wire complete all as specified.
Supply and fix in repair pole juction box sheet mouled compunded (SMC) type with hinged door and door locking arrangement of size 200x140x95mm internal comprising one No SP MCB 6 Apms capacity and one No bakelite based buetral link one No earthing terminal and four Nos aluminium bus bar of suitable capacity including nuts, bolts, MS Clamp etc. complete all as specified and directed.
Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded FRLS conductor of size 1.5 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 1.5 Sqmm and drawn into and including concealed PVC conduit/ PVC casing & capping of 20mm dia with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia and connected to common earth dolly, complete and as directed. Note :- Two run (each run of 1 RM) of 1.5 sqmm copper conductor and one RM of earth wire of 1.5 Sqmm, shall be measured as one RM).
Painting to existing steel tubular LT poles, 9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (Total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping complete and writing pole numbers of 2 inches bold letters with black paint after painting, complete all as specified & directed
Stay assembly complete with MS stay Plate 300X300X6mm thick galvanised stay rod 20mm dia 2.15 metre long with galvanised bow, galvanised thimble, stay clamp etc. complete all as shown on electrical Plate No.01 of SSR Part-I 2009, including taking down unservicable stay complete, all as specified and directed. Note:- (excavation, earthwork, PCC work, loop type insulators and stay wire shall be measured and paid separatly.)
Galvanised stay strand strand, 7/4mm dia complete all as specified.
Loop type insulator, porcelain, vitreous white, brown or green, large size with overall dimensions 50x140mm clearance of hole 25.5mm, including taking down existing unserviceable, complete all as specified.
Plain cement concrete M-7.5 nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundation of stays etc. as mass concrete, complete all as specified.
Supply and fixed in repair of single pointed air termination copper rod 12mm dia, 300mm long having one end flat with one 10mm dia hole fixing on roof top including fixing/fitting of termination rod at one end of GI pipe 25mm dia stand post with the help of nuts, bolts etc and making connection with roof/down conductors and making fixing arrangement of air termination rod over the GI pipe along with aluminium strip etc. all as specified and as directed.
Aluminium strip 25 x 3.15mm fixed on roof, pillars, wall etc, including porcelene isolater having not less than 50mm height with screws & saddles and placed at an interval not less than 50cm in such a manner that strip shoulde not touch the wall /roof/pillar surface etc,. for roof conductors and down conductors above ground above roof/wall/pole, complete fixed in repairs all as specified.
Aluminium thimble suitable for 240mm XLPE cable, fixed in repair, complet all as specified.
Aluminium thimble suitable for 150mm XLPE cable, fixed in repair, complet all as specified.
Aluminium thimble suitable for 120mm XLPE cable, fixed in repair, complet all as specified.
Aluminium thimble suitable for 95mm XLPE cable, fixed in repair, complet all as specified.
Aluminium thimble suitable for 70mm XLPE cable, fixed in repair, complet all as specified.
Aluminium thimble suitable for 35mm XLPE cable, fixed in repair, complet all as specified.
Aluminium thimble suitable for 25mm XLPE cable, fixed in repair, complet all as specified.
surinder kumar jindal & bros.
M/S JATINDERA ENTERPRISES
M/S VIG AND COMPANY
M/S MALHI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .