Loading…
Loading…
Tender Value
₹12.5 Cr
EMD Value
₹7.8 L
Closing Date
20 Feb 2026, 11:00 amClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. Meaning of Similar nature of work : "Any RRI/PI/EI/MACLS Supply, Installation Testing, Commissioning Signaling work OR Any RRI/PI/EI/MACLS Alterations Signaling work OR Any CTC/TMS Work"
39 conditions · 31 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The successful bidder shall submit an MoU from an RDSO approved EI OEM, before the supply of material, to confirm compliance with extant RDSO guidelines and meet contract specific requirements.
Provision of Double Distant signals in Jajiwal(JWL)-Nawa City (NAC) section of JU division of NW Railway.
SNT-JU-34-2025-26
SNT-JU-34-2025-26
Open
Works - General
12 Months
Jodhpur, Rajasthan
₹0
₹7.8 L
20 Feb 2026
27 Jan 2026
6 Feb 2026
63 items across 2 schedules · ₹11,95,06,138.34 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Preparation of SWR literature in english alongwith associated mid- section interlocked gate with all corrections as per approved SWRD & approved SIP. For this all technical corrections, editing, grammatical correction etc. are to be carried out and one rough print to be given to railways for approval before printing, as required for final processing of CRS sanction. This also includes preparation of maintenance cards in format provided by Rly. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | Station | 21.00 | 3,598.62 | 75,571.02 |
| 2 | Translation of Station Working Rules from english to hindi and framing out in DIGLOT form (or similar software )as per extant Rly practice. The required SWR in english will be provided by the contractor and has been covered separately in item no. 1.21 of Chapter 1 of this SOR. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | Station | 21.00 | 4,478.18 | 94,041.78 |
| 3 | Making photocopies & binding of the SWR literature in English/hindi/Diglot form as per Railway practice. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | Set | 147.00 | 178.52 | 26,242.44 |
| 4 | Designing and Plotting of Signaling Interlocking Plan(SIP) in AUTOCAD. Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. Inspection: Consignee Inspection charges: None Payment terms:100% after execution.(Per Unit should be read as Per SIP) | Per Unit | 21.00 | 28,062 | 5,89,302 |
| 5 | Design of circuits and plans to suit layout given in the signalling plan of IBS/ABS/LC GATE. All plans and wiring diagram shall be prepared on Auto cad Drawing and supplied with CD. This will include supply of Control cum Indication panel diagram, Route section plan, square sheet, wiring diagrams, Relay rack/Relay arrangements, Bus bar details, Fuse analysis, contact analysis, Relay room tag block analysis, panel tag block analysis, Power panel diagram, IPS wiring diagram, Auto change over diagram, Power equipment arrangement with program switch, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings. NOTE: The contactor shall initially supply 2 sets of documents (Paper Prints) for approval of Railways. Railway will return one set to the contactor duly approved with alterations/corrections, if any. The contactor shall incorporate Railways' alterations/ corrections/ comments, if any, in the tracing & CD without any deviation and submit all the tracings and Final CD complete with all respect for Approval of Railways. After Approval of Railways on the tracings, the contractor shall submit 3 sets of final approved diagrams to the Railways within 15 days. He shall ensure the each sheet has a block for signature of railway official as well as a block for signature of firm, duly signed by the authorized signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each IBS/ABS/LC Gate. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | Lot | 8.00 | 14,378.9 | 1,15,031.2 |
| 6 | Preparation and supply of laminated one set of all the completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75 micron polyester film for Mid Section Interlocked LC Gate (OSL) on Auto CAD. 6 (Six) sets xerox copies will be provided for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Contact Analysis, Fuse and Tag Block Analysis of Relay Rack and CT Rack, Control Cum Indication Panel/VDU Diagram, Power Panel Diagram, Track Circuit Plan, Rack Erection Plan and Junction Box details etc. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | LC Gate | 8.00 | 8,368.63 | 66,949.04 |
| 7 | Addition/alteration in existing relay room wiring. It includes supply of PVC insulated indoor Railway signalling cable @40<45@Core/40-Core) of (1/0.6) sqmm as per RDSO Spec.No.IRS/S-76/89 (Amnd.2 or latest) for wiring between relay room and SM's/Panel room & Relay room to DP in SM office for block working. This also includes supply of PVC insulated jumper wires of multi strand 16/.2 mm, tinned in all colours as per RDSO Specn.No.IRS-S-76/89(Amnd.2 or latest). This item will include bringing all the power supplies from power room to respective bus bars on relay racks by using 10/6 sqmm copper flexible wire as per instructions of engineer incharge. This will include wiring between control panel and relay room if required. All wiring will be done as per standard practice of North Western Railway with neat dressing & threading. The item includes supply & wiring of tag block, fuse with bases(G-Type and ND Type) and all other related material required for complete indoor wiring in relay room. Inspection: Consignee Inspection charges: None Payment terms:100% after commissioning. | Per Relay | 870.00 | 524.1 | 4,55,967 |
| 8 | Supply of Q-Series LED ECR (Universal Type i.e.QECX-61), 4F/4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09- 2002 ,Amdt.-1and RDSO Specn.No.IRS:S-34 & S-23 or latest.The interlocking code for this unit shall be ""ABDHK"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | Numbers | 232.00 | 4,983.53 | 11,56,178.96 |
| 9 | Supply of DC neutral line relay QNA1K , AC immune, DC neutral line 24V, 6F/6B contacts, complete with plug board, retaining clip and connectors. Conforming to BRS:931A & RDSO letter no STs/E/Relays/UEA/PI dated 30.05.97Annexure II and IRS:S34 & IRS:S23 or latest.The interlocking code for this unit shall be ""CDEKY"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | Numbers | 290.00 | 4,812.82 | 13,95,717.8 |
| 10 | Supply of Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@45"44@ S-23 and S- 60 or latest. The interlocking code for this unit shall be ""ABDGH"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | Numbers | 290.00 | 3,913.67 | 11,34,964.3 |
| 11 | Supply of Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@45"44@ S-23 and S- 60 or latest. The interlocking code for this unit shall be ""ABDFH"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | Numbers | 290.00 | 3,805.5 | 11,03,595 |
| 12 | Supply of Contactor Unit (QBCA1 Type), 24 V DC, 2HF/4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS- 943 and RDSO Specn.No.IRS:S- 34 & S-23 or latest.The interlocking code for this unit shall be ""BCEJK"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | Numbers | 400.00 | 7,080 | 28,32,000 |
| 13 | Supply of ARA Terminal Block (M-6) made of PBT/Poly Carbonate as per RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest and RDSO Drg.No. SA- 23741A(Alt. 4) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | Numbers | 5800.00 | 87.41 | 5,06,978 |
| 14 | Supply of Cartridge Fuse Block made of PBT and as per RDSO Drg. No. SA- 23748 (Alt. 4) or latest and RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | Numbers | 1000.00 | 152.98 | 1,52,980 |
| 15 | 0.6 A | Numbers | 1000.00 | 61.11 | 61,110 |
| 16 | 1.6 A | Numbers | 1000.00 | 64.41 | 64,410 |
| 17 | Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engg. incharge of the work. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution | Per Conductor | 5800.00 | 8.46 | 49,068 |
| 18 | 2V, 80 AH | Numbers | 1200.00 | 2,067.93 | 24,81,516 |
| 19 | 2V, 500AH | Numbers | 180.00 | 11,251.7 | 20,25,306 |
| 20 | 2V 80AH | Numbers | 1200.00 | 371.02 | 4,45,224 |
| 21 | 2V 300AH/ 500 AH | Numbers | 180.00 | 986.73 | 1,77,611.4 |
| 22 | Supply of Track Lead Junction Box(TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (verticall two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two bakellite terminal block fitted horizontally : each bakellite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long.Alongwith each TLJB , nickel chrome plated brass links(two nos.0f adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe of size 32/35mm , 380 mm long alongwith two nuts for fixing on the TLJB hole . (d) The FRP stump for mounting the TLJB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts.The TLJB and the agles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied alongwith TLJB drawing no. 11509. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers | 100.00 | 1,778.4 | 1,77,840 |
| 23 | Erection, Fitting and Rail connection of Track Lead Junction Box on two supports (FRP stumps ) with contractor's fixing material .This will include drilling of holes for track lead/side connections on rail. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution. | Numbers | 100.00 | 1,315.64 | 1,31,564 |
| 24 | Installation of LED signals lamps for auxiliary/subsidiary signals/main signals (i.e. route, shunt , calling on, Red , Yellow, Green) as per instructions given by engineer incharge. The contractor will supply all materials required for installation. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Commissioning. | Numbers | 240.00 | 178.89 | 42,933.6 |
| 25 | Supply of Colour Light Signal Complete. This includes: - ( 1 ) . Post Tubular 140 mm Dia, as per IRS: S- 6/81 or Latest & RDSO Drg. No. SA- 24625 (Advance). (2). CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M with latest assembly). (3). Number plate to Drawing No. S 23149 Alt.1 =1 No , Number plate clamps to Drawing No. S 23148 Alt.1 =2 no (4). Ladder Assembly, as per RDSO Drg. No. SA- 23156, with Base, Ladder Guard rail (complete) to Drawing No. SA 23138 Alt.1(1No), Platform to Drawing No. SA 23134 Alt.1(1 No), Front Maintenance Platform, MS Supporting bracket to Support Ladder.Ladder stay (small) to Drawing No. S 23159 Alt. 1 (2 Nos.) , Ladder stay (large) to Drawing No. S 23160 Alt. 1 (2 Nos.) , Ladder section to Drawing No. SA 23157 Alt. 1(1 Nos.)Stay clamp to Drawing No. SA 2062/M (2 no), Rail Clamp to Drawing No. S 2066/M (1 No.) (5). Signal Front Staging Complete Assembly for CLS Unit. (6). Signal back staging as per extent NWR Practice. Note: Note: Height of the Post shall be 5.5 Long. Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers | 70.00 | 10,791.46 | 7,55,402.2 |
| 26 | 2/3/4 aspect signal unit mounted mounted directly on signal post. | Numbers | 70.00 | 2,187.43 | 1,53,120.1 |
| 27 | Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or l a t e s t . Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers | 70.00 | 28,042.78 | 19,62,994.6 |
| 28 | Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signalling suitable for RE area FOUR Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or l a t e s t . Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers | 2.00 | 29,954.79 | 59,909.58 |
| 29 | Supply of Different warning Boards / Calling on Board used for Railway Signalling system as per RDSO Drg. No. SA2380 (Adv). This includes Painting and retro reflective arrangement should be as per SEM. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | Numbers | 5.00 | 4,637.76 | 23,188.8 |
| 30 | Fixing of Stop Board, Block section limit Board, Shunting Limit Board, goods warning board , Calling on Board with contractors own material. This excludes supply of Stop Board / Block section limit Board / Goods warning board/Calling on board. The work shall be done as per instruction of Rly Engineer at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | Numbers | 5.00 | 334.6 | 1,673 |
| 31 | Supply, Fabrication and fixing of Signal Number Plate( CSTE Drg No CSTE/6186) , 'A' Marker (Drg No. CSTE/6180), 'AG' Marker (Drg No. CSTE/6181), 'P' Marker (Drg No. CSTE/6182), Arrow Marker (Drg No. CSTE/6183), 'G' Marker (Drg No. CSTE/6184), 'C' Marker (Drg No. CSTE/6185). marker disk on signals as per standard practice All material required for this work shall be supplied by Contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | Numbers | 150.00 | 1,223.46 | 1,83,519 |
| 32 | Casting of CC Foundation for Signal Post in the ratio of 1:3:6 as per Drg.No.CSTE/NWR/SOR/21/A using standard size of foundation/galvanized holding down bolts required for erection of colour light signal post. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | Numbers | 70.00 | 9,361.5 | 6,55,305 |
| 33 | Cement concrete work for miscellaneous items in ratio 1:3:6. Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture (aggregate will not exceed beyond 3.8 cm). The aggregate cement and sand will be supplied by contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation.(Unit is per cubic meter) | cum | 20.00 | 4,323.85 | 86,477 |
| 34 | Supply of Domino units with cover plate as per approved panel diagram, each of size 54 x 34mm completely wired up similar to Siemens or similar make. Each domino units should have all the 15 contact terminals wired up. Inspection: Consignee Inspection Charges:None Payment Terms: 100% after Supply. | Numbers | 150.00 | 903.65 | 1,35,547.5 |
| 35 | Supply of Panel Indication LED of White/Red/ yellow colour suitable for Domino Type Control Panel for Railway Signaling. Inspection: Consignee Inspection Charges:None Payment Terms: 100% after Supply. | Numbers | 100.00 | 36.42 | 3,642 |
| 36 | S u p p l y of Apparatus Case half (Medium) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11507. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RECOMMENDED LIST OF FIRMS FOR MECHANICAL SIGNALLING ITEMS if value of whole item in work less than 5 lakhs or as per extant policy Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers | 200.00 | 9,439.4 | 18,87,880 |
| 37 | Installation of Apparatus Cases Half (Medium) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of Location lamp holder , switch and lamp etc. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | Numbers | 200.00 | 632.78 | 1,26,556 |
| 38 | Half (Medium) Case Apparatus case / SS location box as per Drg No CSTE/5074 | Numbers | 200.00 | 5,259.16 | 10,51,832 |
| 39 | Supply of Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 12 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers | 100.00 | 4,855.13 | 4,85,513 |
| 40 | Half Case (Medium Case) | Numbers | 200.00 | 684 | 1,36,800 |
| 41 | Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. (Supply of all above terminals have been covered separately in Chapter 4 of SOR) Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | Numbers | 5800.00 | 12.52 | 72,616 |
| 42 | Cable Size 12C x 1.5 Sq. mm. | Numbers | 100.00 | 4,879.03 | 4,87,903 |
| 43 | Supply of Medium class GI pipes 100 mm dia(4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 with coupling on culverts bridges as per Drg.No.CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | Metre | 2000.00 | 760.66 | 15,21,320 |
| 44 | Fixing of Medium class GI pipes 100 mm dia(4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 with coupling on culverts bridges as per Drg.No.CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | Metre | 2000.00 | 190.17 | 3,80,340 |
| 45 | widthwise ( more than 2 cables).(Unit is per RM Running Meter) | Metre | 150000.00 | 31.87 | 47,80,500 |
| 46 | Supply of Double Walled Corrugated (DWC) HDPE Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti- rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs or as per extant policy Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% after Supply | Numbers | 600.00 | 1,798.2 | 10,78,920 |
| 47 | Horizontal direction drilling/boring without damage of surface road /track using Auger Machine(HDD machine). The bore shall be upto 200 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This include insertion of different dia DWC-HDPE pipe/ GI pipes coupling etc. as per direction of Engineer In charge . Note:- Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | Metre | 3000.00 | 1,202.97 | 36,08,910 |
| 48 | Supply of RCC cable route marker engraved and painted on both side along the route at every 50 meter and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply | Numbers | 3000.00 | 328.68 | 9,86,040 |
| 49 | Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Western Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution( Unit is Cubic Meter) | cum | 45000.00 | 274.28 | 1,23,42,600 |
| 50 | Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.The sharp edges will be smoothened out in bottom of the chase and will be leveled properly. In hard rocky ground area , cables will be laid normally on layer of shifted earth of 0.05 mtrs thickness previously deposited at bottom of the trench and cables will be covered with layer of sand or shifted earth of 0.1 mtr thickness. In case sharp edges of rocky ground can not be protected from shifted earth then GI/ CI /PVC /DWC/ HDPE pipes will be used, if numbers of cables is small.In case number of cables are large RCC duct will be used. In isolated cases, it can be given smooth surface by using either masonry bricks or cement concrete. A row of bricks shall then be placed length wise on the top and jointed with cement mortar and layer of concrete with cement plaster shall be provided on top of the same. Note: This item in hard rocky area will be operated only where normal depth i.e.l.2 mtr is not possible and it will be decided by site engineer/unit officer incharge of work. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution( Unit is Cubic Meter) | cum | 1000.00 | 503.04 | 5,03,040 |
| 51 | Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% a f t e r Execution(unit is RM running meter) | Metre | 600000.00 | 9.1 | 54,60,000 |
| 52 | S u p p l y of earth electrode as per standard practice and as per Drg No.CSTE/NWR/SOR/14A & 14B. It includes supply o f GI pipe of 3m length. Inspection: Consignee Inspection Charges:None Payment Terms: 100% after Supply. | Numbers | 300.00 | 2,232.81 | 6,69,843 |
| 53 | Installation of earth electrode as per standard practice and connecting it to the equipments which are required to be earthed including digging of earth pit 3 mtr deep and fixing earth electrode pipe, casting of cement concrete enclosure with cover as per Drg No.CSTE/NWR/SOR/14A & 14B. It includes installation of 7 strand GI wires as earth lead wires and soldering one end of earth lead wire to earth electrode and other end to block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge. Inspection: Consignee Inspection Charges:None Payment Terms: 100% after execution and testing. | Numbers | 300.00 | 558.2 | 1,67,460 |
| 54 | Apparatus case Half Size. (Outside & inside) | Numbers | 200.00 | 229.9 | 45,980 |
| 55 | Main Signal Post with Signal Units, Surface base and complete fittings as per North Western Railways standard practice. | Numbers | 70.00 | 350.53 | 24,537.1 |
| 56 | Half Case | Numbers | 200.00 | 81.94 | 16,388 |
| 57 | Supply of Compact portable gasolin rail drill machine with belt cover ( HM- 36) drilling capacity 6 to 36 mm. Suitable for 52 Kg , 60 Kg. Tongue rail, point machine base plate .Weight :approx. 15Kg without attachment. Machine size(Max):HxLxW:480x350x260mm, Barrel dia:52+/-1 mm, drilling time 45 second, clamping 25 sec, declamping 15sec. Inspection:RITES Inspection Charges: None Payment Terms: 100% after Supply | Numbers | 2.00 | 8,21,700 | 16,43,400 |
| Schedule total | ₹5,68,61,258.42 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
AdvancecorrectionsliptoGCC2022.pdf
ATTACHMENT
2022_12_13RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril2022ACSNo_2.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_3ACS-311.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_4ACS-4.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_8ACS-8.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_9ACS-9.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_10ACS-10.pdf
ATTACHMENT
SNT-JU-TenderNo.-SNT-JU-34-2025-26.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .