Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹21.5 L+₹17,380 (0.81%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN L1 | |
| 3 | L3₹23.5 L+₹2.1 L (10.0%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN L1 | |
| 4 | L4₹23.6 L+₹2.2 L (10.5%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN L1 | |
| 5 | L5₹24.4 L+₹3.1 L (14.4%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN L1 |
Tender Value
₹22.2 L
EMD Value
₹44,400
Closing Date
30 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE YOL
HQ CWE YOL CANTT
PROVISION OF E/M ALLIED SERVICES UNDER GE PALAMPUR
2021_MES_487436_1
CWE/Y-63/2021-22
Open Tender
Civil Works
Item Rate
180 days
Palampur
As per tender doucments
8 documents required · 8 mandatory
₹500
GE Palampur
₹44,400
Yes
28 Dec 2021
10 Nov 2021
7 Dec 2021
10 Nov 2021
30 Nov 2021
25 Nov 2021
60 days
Amount
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick complete all as specified and directed.
GI pipe light grade of size 80 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
XLPE insulated, armoured heavy duty, LT under ground, electric cable with aluminium conductor, 1100 volts grade, cross sectional area 120 Sqmm, 3.5 core laid in trenches, passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified. Note:- Excavation & Earth work, cable cover and sand cushioning shall be measured and paid separetly.
XLPE insulated, armoured heavy duty, LT under ground, electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm, 3.5 core laid in trenches, passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified. Note:- Excavation & Earth work, cable cover and sand cushioning shall be measured and paid separetly.
XLPE insulated, armoured heavy duty, LT under ground, electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 2 core laid in trenches, passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified. Note:- Excavation & Earth work, cable cover and sand cushioning shall be measured and paid separetly.
Supply installation testing and commissioning of LT 415Volts junction box out door type (IP-55) made of 3mm thick CRCA sheet welded to angle iron 40x40x6mm on all sided, slanted top with 15 cm projection all sides, with openable sutter on both sided (front/rear) having locking arrangement, totally enclosed, weather proof spray painted internally and externally with two coats of synthetic enamel pain over a coat of red oxide primer suitable for 1100 volts, confirming to IP-54, 03 Nos aluminum bus bar of capacity 200 Amps, mounted on LT insulator, connected to two Nos independent earthing lead (width of the panel no less than 75 cm) including legs of panel of 90 cm height made of angle iron 50 x 50 x 6 mm grouted in PCC 1:2:4 upto 30 cm complete, suitable fencing around the panel as per IEC all as specified and directed.
Supply, Installing, testing and commissioning voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 100 KVA complete all as specified and as directed
Supply, Installing, testing and commissioning Outdoor type IP-43, plinth mounted transformer powder coated capacity 400 KVA step down copper wound, oil cooled with all standard fitting HT 11 KV 3 phase and LT 433 volts 3 phase 4 wire, 50 C/S oil immersed naturally cooled with externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V, having tapping at + 2.5% to + 5.0% & + 7.5% on HV side and to be changed by means of hand operated off load/tap changing gear including first filling of new transformer oil of dielectic strength not less than 40 KV with all fitting and accessories such as LT box at LT side, silica gel breather, oil level indicator conservator tank with oil level indicator, drain out valve (oil tank), exhaust vent, air release valve, temperature gauge and cast iron wheel etc all as IS-2026 & IS-1180 complete all as specified and directed. Note: Necessary manufacturer certificate to be obtained for 99% copper purity.
Supply, install, testing & commissioning of CPRI approval LT panel board, outdoor type IP-54, floor mounted, factory made suitable for 415 Volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bar chamber made out of size 60 cm x 60 cm x 30 cm with angle iron of size 40 x 40 x 5 mm with copper bus bars duly insulated by insulation of RYB colour 250 Amps rating mounted on porcelain insulators. The panels shall be factory made , double door, made out of 3.15 mm thick MS sheet (CRCA) totally enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of size 40x40x6 mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multi stranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable etc all as directed at site and comprising of the following:-
(a) MCCB 160 A, 4P, 415 Volts AC supply , thermal magnetic release type 36 KA-01 No (Incoming) (b) MCCB 125, 4P, 415 Volt 25 KA thermal magnetic relase type -02 Nos. (Outgoing) (c) Panel mounted multi function meter for measuring Voltage (0-500 Volts), Current (0- 100 Amps) and frequency-01 No (d) RYB neon indicating lamp panel mounting type (Set of three ) - 01 N0. (e ) Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses (f) Cable entry gland and two nos earthing terminal
Supply, install, testing & commissioning of CPRI approval LT panel board, outdoor type IP-54, floor mounted, factory made suitable for 415 Volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bar chamber made out of size 60 cm x 60 cm x 30 cm with angle iron of size 40 x 40 x 5 mm with copper bus bars duly insulated by insulation of RYB colour 1000 Amps rating mounted on porcelain insulators. The panels shall be factory made , double door, made out of 3.15 mm thick MS sheet (CRCA) totally enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of size 40x40x6 mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multi stranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable etc all as directed at site and comprising of the following:-
(a) MCCB 630 A, 4P, 415 Volts AC supply , thermal magnetic release type 50 KA-01 No (Incomer) (b) MCCB 250A, 4P, 415 Volt 36 KA thermal magnetic relase type -02 Nos. (Outgoing) (b) MCCB 160A, 4P, 415 Volt 36 KA thermal magnetic relase type -01 Nos. (Outgoing) (b) MCCB 125A, 4P, 415 Volt 36 KA thermal magnetic relase type -02 Nos. (Outgoing) (c) Panel mounted multi function meter for measuring Voltage (0-500 Volts), Current (0- 600 Amps) and frequency-01 No (d) RYB neon indicating lamp panel mounting type (Set of three ) - 01 N0. (e ) Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses (f) Cable entry gland and two no earthing terminal
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 32mm x 6mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
M/s Sheetal Associates
KISHAN CONTRACTOR
M/S RANA BUILDERS
M/S PUSHPINDER ENGINEERS
Krithvik Electricals
ABHAY ELECTRICAL
surinder kumar jindal & bros.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .